Strip Chart Recorders Specification Sheet

Similar documents
Paperless Graphic Recorder Specification Sheet

Temperature/Process Controllers Manual

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

LBVR1718. Description. Features channel paperless recorder

/8 DIN Universal Process Indicator

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

DPR 100 A/B Analog Scales

SX90 Process Controller

100mm Process Indicator Recorder

DIGITAL INDICATING CONTROLLER

C160 Wall-/Pipe Mounted Universal Process Indicator

Networked or Standalone Graphic Data Acquisition Unit Specification Sheet

Inform IT Single Pen Circular Chart Recorder

ABB Instrumentation. Multipoint Chart Recorder COMMANDER SR250B. Specification DataFile

Eycon 10 and Eycon 20 Visual Supervisors Specification Sheet

DATAWATCH IX Installation Guide

Wall-/Pipe Mounted Universal Process Indicator

Inform IT 250mm Multipoint Strip Chart Recorder

/8 DIN Motorized Valve Controller

MIC-2 MKII, Multi-instrument DATA SHEET

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

DINALOG A 144 x 36 A1400 Light-Strip Indicator

FICHA TÉCNICA DE PRODUTO

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

UNIVERSAL TEMPERATURE TRANSMITTER

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

4100G EUROTHERM CHESSELL. Model 4100G Video recorder. Technical manual

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Indicomp 4 Bargraph Indicator

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

Contents. Temperature & Process Measurement Indicators Setup Guide

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

CJ1W-PTS/PDC/PH41U/AD04U

RT4F-120V/20A-WAC RECTIFIER

AMC8 and IOC8T Analog monitoring card and input / output card

Paperless recorder Ecograph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

HART UNIVERSAL TEMPERATURE TRANSMITTER

HART UNIVERSAL TEMPERATURE TRANSMITTER

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

02/11/2015

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Operating Manual. Dynisco /8 DIN Indicator Concise Product Manual

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Easy to Use and Versatile Data Recording Solutions

Universal Process Controller

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Printing recorder with text printing and 24-character LED dot-matrix display. Brief description. Overview of functions. Features

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

Mini Digital Multimeter

MIC-2 Multi-instrument DATA SHEET

Mini Digital Multimeter

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

Detailed Specifications 6 1/2 Digits High-Performance DMM

RT4B-110V/12A RECTIFIER

RT4F-48V/50A-WAC RECTIFIER

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Voltage Transducer UMT516 / MT516

Color hybrid recorder alpha-log

TM3TI4 module TM3-4 inputs temperature

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

TM3TM3 module TM3-2 temperature inputs and 1 analog output

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder

MODCELL 2050R Single Loop Controllers

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT

Autoranging True RMS Multimeter User Manual

-10 to 10V to User range setting. 4 to 20mA 0 to to 20mA 500.0nA

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

JUMO Quantum PID100/PID200/PID300

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

RT4F-110V/25A RECTIFIER

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

TM3TI4 module TM3-4 inputs temperature

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Transcription:

4101C, 4101M 4102C, 4102M MODELS Continuous Pen Recording 1, 2, 3 or 4 Pens Multi-point Recording Providing 6 Colour traces High Visibility Display 4101C, 4101M Clear Analogue Scale 4102C, 4102M Large 7 Segment numeric Display Strip Chart Recorders Specification Sheet The 4101/2 are low cost, 100mm strip chart recorders, providing recording for up to 4 (continuous pen) or 6 (multi-point) process variables. Designed to fit a DIN cut out (138 x 138 mm) the recorders feature an exceptionally small back panel dimension of 236mm with the cover fitted. Display An analogue scale, specified at the time of order is supplied with all 4101 recorders. The 4102 is supplied with a high visibility seven segment display, providing clear numeric indication of the process variables, and alarm status. The display will cycle through each PV, but can be paused on a particular channel if required. Configuration The 4101 is supplied pre-configured and ready for use. The addition of a keypad to the 4102 allows for configuration to be carried out on site. In order to prevent unauthorised access to the 4102, the configuration is password protected. Entry of the password provides access to the instrument configuration pages. It is possible to provide the operator access to certain parameters, for example you may require the operator to be able to change the chart speed Modular Design All The modular design of the 4100 Series allows for upgrades to be carried out in situ thus reducing downtime. Isolated Universal Inputs Select from ma, mv, V, Thermocouples and RTD Power supply unit (PSU) On/Off switch (Not all models) Annotation Clear text printing of time/date and messages Option board slot 2 Option board slot 1 Option board slot 4 Option board slot 3 Main (input) board Exploded view DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

TECHNICAL SPECIFICATION Input Board General Input types Input type mix Max no of inputs 4101C, 4102C 4 4101M, 4102M 6 Input ranges Termination Noise rejection (48 to 62 Hz) Maximum common mode voltage Maximum series mode voltage dc Volts, dc millivolts,dc milliamps (with shunt), Thermocouple, 2 / 3-wire RTD (Channel 1 can be RTD only if no other channels are thermocouple) User configutrable 30 to +150mV; 0.2 to +1 Volt; 2 to +10 Volts Edge connector / terminal block Common mode: >140dB (channel to channel and channel to ground). Series mode: >60dB. 250 Volts continuous 180 mv at lowest range; 12 Volts peak at highest range. Isolation (dc to 65 Hz; EN61010) Installation cat. II; Pollution deg. 2 Channel to channel: 300V RMS or dc (double insulation) Channel to common electronics: 300V RMS or dc (double insulation) Channel to ground: 300V RMS or dc (basic insulation) Dielectric strength (BS EN61010) (1 minute type tests.) Channel to channel: 2300 Vac Channel to ground: 1350 Vac Insulation resistance >10MΩ at 500V dc Input impedance 150mV and 1V ranges: >10MΩ; 10V range: 68.8kΩ Over voltage protection 50 Volts peak (150V with attenuator) Open circuit detection ±57nA max. Recognition time 4101C, 4102C 250 msec 4101M, 4102M 500 msec Minimum break resistance 10MΩ DC Input ranges Shunt/attenuator Externally mounted resistor modules Additional error due to shunt 0.1% of input Additional error due to attenuator 0.2% of input Performance See table 1 Low High Resolution Maximum error Worst case temperature Range Range (Instrument at 20 C) performance 30mV 150mV 5.5µV 0.084% input + 0.053% range 80ppm of input per C 0.2V 1V 37µV 0.084% input + 0.037% range 80ppm of input per C 2V 10V 370µV 0.275% input + 0.040% range 272ppm of input per C Table 1 DC performance Thermocouple data Temperature scale ITS 90 Bias current 0.05 na Cold junction types Off, internal, external CJ error 1 C; instrument at 25 C CJ rejection ratio 50:1 minimum Upscale / downscale drive High, low or none Types and ranges See table 2 T/C Overall range Standard Max linearisation error Type ( C) (4102C, 4102M only) B 0 to +1820 IEC 584.1 0 to 400 C: 1.7 C 400 to 1820 C:0.03 C C 0 to +2300 Hoskins 0.12 C D 0 to +2495 Hoskins 0.08 C E 270 to +1000 IEC 584.1 0.03 C G2 0 to +2315 Hoskins 0.07 C J 210 to +1200 IEC 584.1 0.02 C K 270 to +1372 IEC 584.1 0.04 C L 200 to +900 DIN43700:1985 0.20 C (To IPTS68) N 270 to +1300 IEC 584.1 0.04 C R 50 to +1768 IEC 584.1 0.04 C S 50 to +1768 IEC 584.1 0.04 C T 270 to +400 IEC 584.1 0.02 C U 200 to +600 DIN43700:1985 0.08 C Ni/NiMo 0 to +1406 Ipsen 0.14 C Platinel 0 to +1370 Englehard 0.02 C Table 2 Thermocouple types and ranges Resistance inputs Ranges (including lead resistance) 0 to 600Ω, 0 to 6kΩ Influence of lead resistance Error: negligible; Mismatch: 1 Ω/Ω Temperature scale ITS90 Resolution and performance See Table 3 RTD types and ranges See Table 4 Low High Resolution Maximum error Worst case temperature Range Range (Instrument at 20 C) performance 0Ω 600Ω 22mΩ 0.045% input + 0.065% range 35ppm of input per C 0Ω 6000Ω 148mΩ 0.049% input + 0.035% range 35ppm of input per C Table 3 Resolution and performance for resistance inputs RTD Overall range Standard Max linearisation error Type ( C) (4102C, 4102M only) JPT100 220 to +630 JIS C 1604:1989 0 01 C Ni1000 60 to +250 DIN43760:1987 0.01 C Ni120 50 to +170 DIN43760:1987 0.01 C Pt100 200 to +850 IEC 751 0.01 C Pt100A 200 to +600 Eurotherm 0.09 C Recorders SA Pt1000 200 to +850 IEC 751 0.01 C Table 4 RTD types and ranges INSTALLATION CATEGORY II The rate impulse voltage for equipment on nominal 230V mains is 2500V. POLLUTION DEGREE 2 Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation shall be expected Recorder Board types Standard: Universal input / control board Options: 3- Change-over relay output board Transmitter power supply Event input board, Annotator board Environmental Performance Temperature limits Operation: 0 to 50 C. Storage: 20 to + 70 C Humidity limits Operation: 5% to 80% RH (non-condensing) Storage: 5% to 90% RH Protection Door and Bezel: IP54 Sleeve: IP20 Transmitter PSU cover: IP10 Shock BS EN61010 Vibration 2g peak at 10 Hz to 150Hz Altitude (max.) 2000 metres Power requirements Line voltage Standard: 90 to 264V at 45 to 65 Hz Enhanced interrupt protection: 90 to 132V at 45 to 65 Hz Low voltage: 20 to 54V dc or 20 to 35V ac (45 to 400 Hz) Power (Max) 100 VA Fuse type Not user accessible Interrupt protection Standard: 40ms at 75% max. instrument load Enhanced: 120ms at 75% max. instrument load Electromagnetic compatibility (EMC) Emissions BS EN50081-2 Immunity BS EN50082-2 Electrical safety To EN61010: Installation category II; Pollution degree 2 Physical Panel mounting Bezel size Panel cutout dimensions Depth behind bezel rear face Weight Panel mounting DIN43700 144 x 144 mm. 138 x 138 (both - 0 + 1 mm) 220 mm (No terminal cover); 236 mm (standard terminal cover) 275 mm (long terminal cover closed) 390mm (long terminal cover open) < 3.5kg Vertical ±30 C

TECHNICAL SPECIFICATION (continued) Recorder (continued) Printing System 4101C, 4102C Pen type Disposable fibre-tipped pens Pen resolution 0.15 mm Trace colours See Table 5 Pen life 1.2km (channel); 7.5 x 10 5 dots (annotator) Update rate 4 Hz Response time (max) 2 seconds Characters per line 38 Channel 1 (top) 2 3 4 (bottom) Annotator Colour blue red green violet black Table 5 4101C, 4102C Trace colours Printing System 4101M, 4102M Pen type Six nib cartridge Pen resolution 0.2 mm Trace colours See Table 6 Pen life 1.5 x 10 6 dots per colour Update rate 2 Hz Response time (max) 1 pass every 5 seconds Characters per line 42 Channel 1 2 3 4 5 6 Colour violet red black green blue brown Table 6 4101M, 4102M Trace colours Paper transport Type Stepper motor driving sprocket tube Chart speeds 4101C, 4102C with annotation Off 5, 10, 10, 20, 30, 60, 120, 300 mm/hr 4101C, 4102C annotation inhibited 600, 1200, 3600, 18000, 36000 mm/hr Chart type 4101M, 4102M Off, 5, 10, 20, 30, 60, 120 mm/hr Standard 16 metre z-fold Option 32 metre roll Vacuum flurescent display (4102C, 4102M) Process value Four, blue 15mm high characters with minus sign as required Channel number Single, green 8mm high character Alarm indication Pair of red arrows for high and low alarms Channel hold indication Red H below channel number when channel hold inoperation Keypad 5-key keypad for operator/ configuration access Options All isolation figures are Installation category II and Polution degree 2 Relay outputs Maximum switching power 500VA Maximum breaking current 2 Amps within above power ratings Maximum contact voltage 250V within above power ratings Maximum dc ratings See Graph 2 Contact-contact 300V RMS or dc (double insulation) Contact to ground 300V RMS or dc (basic insulation) Estimated life* 30,000,000 operations * With resistive loads. With inductive loads, derate according to Graph 1, in which: Contact life = resistive life x F1 or F2 where F1 = measured on representative examples and F2 = typical values according to experience Reduction Factor F 0.9 1F 0.8 0.7 0.6 0.5 0.4 F1 Graph 1 Derating curves F2 0.3 1 0.8 0.60.4 0.2 Power factor (cos φ) Graph 2 DC ratings Event inputs Event input to ground: 100V RMS or dc (double insulation) Event input to Event input: 0V Recognition levels Low: 30V to +0.8V High: 2 to 30V Transmitter Power Supply Output voltage 3 or 6 x 25V dc (nom) outputs Channel to channel: 100V RMS or dc (double insulation) Channel to ground: 100V RMS or dc (basic insulation) Cover rating IP10 DC Voltage (Volts) Max. DC load breaking capacity 300 200 resistive load 100 50 40 30 20 inductive load (L/R = 20msec) 10 0.1 0.2 0.5 1 2 5 20 DC current (Amps) MECHANICAL INSTALLATION SUPPLY VOLTAGE AND INPUT BOARD TERMINATION 144mm 144mm Front view 27mm 30mm 4102 only 390mm (LTC open) 275mm (LTC closed) 236mm (STC) 220mm 200mm Case clamp Maximum panel thickness 25mm View on right hand side 137mm 1.75mm 4101C, 4102C Line input: 90 to 264V (45 to 65 Hz) OR, if low voltage option fitted: 20 to 54V dc or 4101M, 4102M 20 to 53V ac (45 to 400 Hz) Line input: 90 to 264V (45 to 65 Hz) Safety cover not OR, if low voltage option fitted: shown for clarity 20 to 54V dc or Earth Line Neutral (dc+) (dc ) 20 to 53V ac (45 to 400 Hz) DC polarity not important, but + terminal fused Safety cover not shown for clarity Earth Line Neutral (dc+) (dc ) DC polarity not important, but + terminal fused 138mm x 138mm ( 0.0 + 1.0mm) 137mm Panel cutout Min. inter-recorder distance: 35mm Note STC = Short terminal cover (standard fit) LTC = Long terminal cover (option) View on under side (STC shown) Alternative location for case clamp 4101 only Input board 1 2 3 4 5 6 7 8 9 10111213141516171819202122 V+ V- I Int. Ch 1 CJ Ch 2 Ch Input 3 board Ch 4 1 2 3 4 5 6 7 8 9 10111213141516171819202122 Int. Ch 1 Ch 2 Ch 3 CJ Ch 4 Ch 5 Ch 6 If ch1 = RTD, both legs of the internal CJ sensor are wired to terminal 11

INPUT BOARD SIGNAL WIRING V+ V I V+ V I V+ V I V+ V I V+ V I V+ V I Shunt assembly Attenuator assembly DC V ( 2V to +10V) DC mv Thermocouples DC ma DC V ( 20 to +100V ) 3-wire resistance thermometer 2-wire resistance thermometer Potentiometer Shunt assembly 100Ω = LA246779UK10 250Ω = LA246779UK25 Attenuator assembly LA244180 Steriliser Option 4101/2 This option offers four inputs to control chart on/off and annotation of events. Configuration Editor An offline configuration package that allows a recorder configuration to be set up on a PC and transferred by the 3.5mm jack plug. Contact 1, when closed the chart runs normally. When open the pens are parked at Zero and the chart winds on 80mm. Contact 2, applies to annotating recorders only. When closed the current time and date is printed, and as long as the contact remains closed the chart will run at its selected speed, with annotation inhibited. Once the contact goes open the pens are zeroed; the time date, scales and chart speed are printed and the chart is advanced by 80mm and stopped. Contact 3, applies to annotating recorders only. On closure the message "EVENT START HH:MM:SS" is printed, where HH:MM:SS show the time of closure in hours, minutes and seconds. On the contact opening, the message "DURATION HH:MM:SS" is printed, where HH:MM:SS shows how long the contact was closed, therefore providing Sterilisation time. Contact 4, If either contact 1 or 2 is closed then pen 4 (continuous) or pen 6 (multipoint ) is used to show the status of Contact 4. Whilst contact 4 is open the trace is at 100%, whilst closed the trace is at 96%.

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.