Saved Data playback Saved data in Memory card can be easily called out and played back on display

Similar documents
Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver

PAPERLESS RECORDER SPECIFICATIONS PHF DATA SHEET. Input system. EDS10-77d

PAPERLESS RECORDER. Specifications Sheet No.SPEC-1137E (1st Edition)

PAPERLESS RECORDER OUTLINE FEATURES SPECIFICATIONS. Easy operation with touch panel providing an intuitive user interface

Paperless Recorder VGR-B100. Series

Type : PHF INP-TN1PHFQR-E

Type : PHF. INP-TN1PHFQRc-E

Instruction Manual PAPERLESS RECORDER TYPE: PHF. INP-TN1PHFc-E

ARF100 Paperless Recorder

ARF200. Paperless Recorder Advanced Recorder

SX 6000 Paperless Recorder

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

Compact data logger offering best-in-class noise resistance and communication function

Technical Information

Instruction Manual PAPERLESS RECORDER TYPE: PHU INP-TN1PHU-E

PARAMETER LOADER FOR PAPERLESS RECORDER

BACnet Controller for General-purpose Building Applications

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

XL112, XL114 ポータブルデータロガ

DISCONTINUED MODEL Replaced with Model MSRPAC-2006

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

DATA VIEWER FOR PAPERLESS RECORDER

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

User s Manual RD-MV1000/RD-MV2000 M st Edition

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

PR Series Paperless Recorders

Color Printer Microjet Recorder Series

Web-enabled DAQ System

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

8420/8421/ MEMORY HiLOGGER

PCPR01 Paperless Recorder

DATA VIEWER FOR PAPERLESS RECORDER

RD2000, 5.6" display. All models shown smaller than actual size.

midi LOGGER GL840 Quick Start Guide GL840-UM-850

midi LOGGER GL240 Quick Start Guide GL240-UM-852

Datum-Y Portable Data Station (XL100)

DATA LOGGER Series SELECTION GUIDE

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

PXR Series Advanced Self-Tuning Temperature and Process Controllers

KEHAO INSTRUMENT. Xiamen Kehao Automation Co., Ltd KH102 INTELLIGENT PROCESS INDICATOR KEHAO INSTRUMENT

DATA VIEWER FOR PAPERLESS RECORDER

SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System

VR18 FAQs - Frequently Asked Questions

General Specifications

horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized measured values

Compact Controller M CC-M

SV100 Video Recorder

midi LOGGER GL240 Quick Start Guide GL240-UM-850

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

MW100. Data Acquisition Unit. Data Acquisition Unit MW100.

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

DATA LOGGER Series SELECTION GUIDE

, , MEMORY HiLOGGER

Programmable Display. Feel the difference in power of expression, speed and networking capability. 9027NE1

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

/8 DIN Universal Process Indicator

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

NF760 Batch Controller

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Advanced Test Equipment Rentals ATEC (2832)

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

DATA VIEWER FOR PAPERLESS RECORDER

MEMORY HiLOGGER LR Featuring USB flash drive support and improved accuracy

Paperless Recorder. User s Manual KT200R IMA22-CP01

Operation Guide MX100 Data Acquisition Unit

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851

SmartView 100 (SV100) 100mm Paperless Data Acquisition System

Portable Paperless Recorder MV1000/MV2000

EDX-10 Series. Compact Recording System

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

Expanding the Basic GL7000 Configuration

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

/8 DIN Motorized Valve Controller

INPUT Input point Measuring cycle Input type Disconnection detection Input filter

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder

C160 Wall-/Pipe Mounted Universal Process Indicator

GRAPHIC RECORDER KR2S SERIES PSE-801

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

TDS-630. High Performance Easy Handling

Trident and Trident X2 Digital Process and Temperature Panel Meter

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014

Your Personal 10-channel Logger. MEMORY HiLOGGER LR8431. Featuring USB flash drive support and improved accuracy

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Precision thermometer Model CTR5000

Wall-/Pipe Mounted Universal Process Indicator

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

LBVR1718. Description. Features channel paperless recorder

Transcription:

Paperless Recorder Type:PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display (10Base-T) is available. (option) Screen saver Period of non-operation exceeds the setting value of parameter, recorder turns off the backlight of LCD. PC support softwares (Data Viewer/Parameter Loader) Supplied in a CD-ROM as a part of standard accessory Compact size 160 (W) X 144 (H) X 185 (D) mm (Panel mount) 1.5 kg compact size 3-point recording and 6-point max. recording 12 types of thermocouples, 5 types of resistance bulbs and voltage/current input are available Type: PHF A.P.O. - ELMOS v.o.s., Pražská 90, 509 01 Nová Paka, Tel.: +420 493 504 261, Fax: +420 493 504 257, E-mail: apo@apoelmos.cz, Internet: www.apoelmos.cz 21B1-E-0005

Provides flexibility and variety in the handling of record data. Status Display Allows you to display screen name, calendar, alarm information, recording status, writing status of measured data in Compact Flash, and fitting status of the card into the recorder slot. Time display Indicates the time and time scale of recorded data. Trend Display Allows you to view measured result in waveforms. Digital Display Allows you to view measured values in a digital form. Key panel Allows you to perform the recording start/stop, selection of display, setting, data display/change. Power indicator During power on, LED turns on. While screen saver is working, it flickers. About 4 years' worth of data can be recorded in Compact Flash (512 MB). (10Base-T) is available. It has FTP, HTTP (Web server), SMTP and MODBUS-TCP protocols. Hub IE display (Digital value display) Calculation function offered as standard Subtraction Difference between the values of each channel can be calculated. Square root extraction Square root extraction of the input value of each channel can be performed. 2

Wide variety of display mode Trend recording (horizontal) Measured result is horizontally displayed in real time. Trend recording (vertical) Measured result is vertically displayed in real time. Bar graph Measured values are displayed in bar graph. Digital display Channel No., Tag No. engineering unit, and alarm information are displayed in digital form, in addition to measured values. Historical trend display Past data saved to Compact Flash can be viewed. Scroll function is usable. Event summary display Alarm status and external control input status for each channel are displayed. Easy operation without the help of the instruction manual The onscreen guidance enables you to set/change various parameter data easily. Setting Menu screen Setting screen 3

Feature communication connects PHF recorder to industrial network and/or Internet. (Option) Web FTP E-mail MODBUS-TCP Web function You can display process values and/or event summary using Internet Explorer. (Netscape is not supported) and more features such as Easy setup, with no need for communication converters Standard Loader software enables reading/writing of the PHF s parameter settings IE display (Digital value display) Hub FTP function The record files in Compact Flash can be listed, downloaded to PC and deleted from Internet Explorer. Recorder configuration can also be uploaded/downloaded. E-mail function PHF recorder can send E-mails to maximum 8 addresses at up to 10 trigger timings through a mail server on the same LAN. Internet [Items sent] Subject Contents (32 characters per set 2) Process values Name of sender and time Hard disk, etc Compact Flash Mail server [Timing of sending] E-mail can be sent when either of the following events occurs. Corporate LAN network Alarm ON / Alarm OFF DI ON / DI OFF Specified intervals (every 1, 2, 3, 4, 6, 12, 24 hours) Failure of PHF (No battery, run out of memory, etc.) MODBUS-TCP function You can link the recorder with all network, supervisor or SCADA system by MODBUS TCP/IP protocol. Easy connection communication need no communication software. RS485 Wiring Hub LAN cable (connector) RS232C converter Twisted pair line (screwed on) Software No communication software. Internet Explorer and Fuji standard software (Parameter loader and Data Viewer) are all you need. Dedicated communication software is necessary to be created. specification : Internet Explorer can be used as a browser (Netscape is not supported). Windows 2000 or XP / 7 is required. Http (server) You can browse the following screens by setting PHF's IP address on Internet Explorer (ver.6). (Change of setting value is not possible) [Measured value display screen] PV value for each channel (instantaneous value) Recording condition Memory usage of Compact Flash Alarm Status [Event summary screen] The information on the event summary screen of the recorder. FTP (server: read only) FTP server function allows you the followings by setting PHF's IP address on Internet Explorer. Browse of file names in the Compact Flash Files can be downloaded to PCs, deleted or changed their names. It's also available to access by using command prompt. User ID and password are needed to access to recorder. (simultaneous access by multiple users is inhibited) SMTP (client) E-mail can be sent when the mail server is available in the same LAN network. E-mail cannot be received from an external network. The items sent and timing of sending are as follows. [Timing of sending] DI ON, DI OFF Alarm ON, Alarm OFF Failure occurred in main unit (no battery, memory card is full, etc.) Periodic [Items sent] Subject of E-mail (32 characters) Message (32 characters 2) PV value (instantaneous value) Sent time Name of sender [Number of registered recipient addresses] 8 (the items and timing can be set for each recipient) MODBUS-TCP with MODBUS-TCP protocol through is available. Reading from each parameter, and writing/reading is enabled (for details, refer to the separate communication manual). Loader software Loader software installed as standard enables parameter settings to be read and written, but writing is not allowed during recording. medium (10BASE-T) 4

General specifications Mounting method Material External dimensions and mass Power supply voltage Power consumption External terminals Operate temperature Input unit No. of inputs Measuring cycles Recording cycle Input signal Input types Burn-out function Calculation function Display unit Display Life of backlight Display contents Recording function Recording medium Memory capacity Recording method Data save cycles Data format Trend data Event data Storage capacity Panel flush mounted Molding resin (case, bezel) <Panel mount> 160 x 144 x 185 mm, about 1.5 kg (6-point input) 100V to 240V AC, 50/60 Hz About 42VA (at 240VAC) Screw terminals (M3 thread) 0 to 50 C (in case the 12th digits of code symbols is Y.) 0 to 40 C (in case the 12th digits of code symbol is E.) Note: In case of 30 degree C or more for ambient temperature.this display might be fogged little bit. (This is not out of order.) 3 or 6 points 100ms 1sec to 12hours Thermocouple: 12 types (B, R, S, K, E, J, T, N, W, L, U, PN) Resistance bulb: 5 types (Pt100, JPt100, Ni100, Pt50, Cu50) DC voltage: (0 to 50mV, 0 to 500mV, 0 to 5V or 1 to 5V) DC current: (connecting optional shunt resistor to input terminal) Selected from the key panel (the same type should be set for every 2 channels) Equipped with thermocouple and resistance bulb inputs as standard. Primary delay filter, scaling, calculation of difference between channels, and square root extraction 5.7" STN color LCD (320 X 240 dots) (The LCD may have some pixels that do not stay on or off. Due to the characteristics of liquid crystal, the brightness may not be uniform, which is not a failure.) 50,000 hours Trend display (in vertical and horizontal direction) selected in the refreshment cycles of 1 sec to 12 hours. Scale display/non-display selectable Bar graph display (refresh cycle: 1 second) Digital display (in refreshment cycle of 1 sec) Event summary display (alarm and message summary) Historical trend display (Compact Flash memory data.) Compact Flash card (Format as FAT16 or FAT, or recorder can t read and write.) 2GB, max. Writing starts in fixed cycles by turning ON the REC key on the front panel. Data is recorded in a new file every time the recording starts. Links to refreshment cycle of the trend display ASCII About 118 bytes per sampling (at 6 channel inputs) Binary (Data cannot be read directly into Excel, etc.) About 28 bytes per 1 sampling (6-channel input) Maximum value and minimum value are saved from the data that are sampled in measuring cycles. Alarm data and message data are saved. About 4 years at display refresh cycle of 30 seconds (ASCII) About 16 years (Binary) (6-channel recording, 512MB compact flash used) Specifications Amount of memory used Alarm function No. of settings Type of alarm Indication Output Reference performance Indication accuracy Indication resolution Reference junction Compensation accuracy Input resistance Others Clock Memory backup Memory full alarm Low battery alarm Optional specification Alarm (relay) output/di () PC support software (standard-supplied CD-ROM) O/S PC/AT-compatible machine Required memory capacity Contents The display unit displays how much the memory card has been used via bar graphs. The recording will stop if the amount of recorded data exceeds the capacity. Up to 4 alarms are settable for each channel. High/Low limits Alarm status is displayed on digital display unit when an alarm occurs. Histories are displayed in the alarm summary. 10 points as relay output (option) ±(0.15%+1 digit) of input range Accuracy of the next range is ±(0.3%+1 digit). Thermocouple B: 400 C to 600 C, thermocouples R and S: 0 C to 300 C, thermocouples K, E, J, T, L, and U: -200 C to -100 C 0.1 C ±0.5 C Thermocouples R, S, B and W: ±1.0 C About 1MΩ With calendar function Parameter settings are saved to the internal nonvolatile memory. The clock is backed up by a built-in lithium battery. Trend data is back up only 400 samplings. When the amount of recorded data exceeds the capacity of memory card, recorder can energize the alarm output. When the battery for backup of clock and SRAM becomes low, recorder can energize the alarm output. 10 relay outputs and 5 DI are added. Alarm output: SPST Output for each channel or common channel is possible. DI input: 5 no-voltage contact input points, Recording start/stop, or LCD turning on functions can be performed. 10Base-T FTP server * (Internet Explorer 6. FFFTP or Comand Prompt are available) HTTP server * (Web server. Internet Explorer 6 is available) SMTP (e-mail client) MODBUS-TCP * Netscape and Mozilla Firefox are not available Windows XP/2000/7 Operation on PC98-series machines by NEC is not guaranteed. Operation on self-made or shop-brand PCs is not guaranteed. 64 MB or more The following types are included as standard. 1) Data viewer software It allows you to view the past trend recorded data from the data saved to the Compact Flash on PC. Historical trend and event display functions are provided. 2) Parameter loader software It allows you to perform setting/change of various parameters on PC. 5

A convenient PC support software package is included as standard Past data saved to Compact Flash can be viewed on personal computer. Parameters for the recorder can be easily set and changed from personal computer. Historical trend data screen Parameter setting screen Before use, install PC support software supplied as standard. O/S: Windows XP/2000/7 Required storage capacity: 64 MB Provide PC card adapter separately. Recomended type: SDAD-38 PC/AT-compatible machine Operation on PC98-series machines by NEC is not guaranteed. Operation on self-made or shop-brand PCs is not guaranteed. Before use, install PC support software supplied as standard. O/S: Windows XP/2000/7 Required capacity of memory: 64 MB A communication cable between recorder and pc is optional. Type: PHZP1801 PC/AT-compatible machine Operation on PC98-series machines by NEC is not guaranteed. Operation on self-made or shop-brand PCs is not guaranteed. 6

Outline Diagram and Panel Cut (Unit: mm) Panel mount type 3 or 6-points input 2 T 26 PANEL T MTG.BRACKET INPUT TERMINAL ETHERNET SOURCE TERMINAL(OPTION) TERMINAL L N For mounting one unit For mounting multiple unit 137 +1.5 0 (160Xn 22) +2 0 137 +1.5 0 137 +1.5 0 144 136.5 161 100~240VAC R-MODULE Rcj Fuji Electric REC DISP SEL ENT 160 140 21.6 185 136.5 IN CASE OF 3,6-POINT INPUT DIGITAL INPUT & ALARM OUTPUT (OPTION) Note: When placing the main unit on another instrument or on the floor, allow a space of 100mm or more between the unit and instrument or the floor. Panel cutout External connection diagram 3 or or 6-points 6-points input input ALARM OUTPUT DIGITAL INPUT TERMINAL ALARM OUTPUT / DIGITAL INPUT TERMINAL INPUT TERMINAL INPUT TERMINAL SOURCE TERMINAL SOURCE TERMINAL 231 231 232 232 233 233 234 234 235 235 236 236 237 237 238 238 239 239 240 240 241 241 242 242 243 243 244 244 245 245 211 DI1 211 212 DI2 DI1 212 213 DI3 DI2 213 214 DI4 DI3 214 215 DI5 DI4 215 216 DO1 DI5 216 217 DO2 DO1 217 218 DO3 DO2 218 219 DO4 DO3 219 220 DO5 DO4 220 221 DO6 DO5 221 222 DO7 DO6 222 223 DO8 DO7 223 224 DO9 DO8 224 225 DO10 DO9 225 DO10 CH4 CH4 CH5 CH5 CH6 CH6 R.T.D T.C. DC DC T.C. R.T.D R.T.D T.C. DC DC T.C. R.T.D 11 + + 11 12 CH1 12 13 CH1 13 + + 41 41 42 42 43 21 43 21 + + 22 CH2 RCJ 22 CH2 RCJ 23 23 + + 51 51 52 52 53 53 + + 61 31 + + 61 CH3 62 32 31 63 33 CH3 62 32 63 33 AC100~240V 50/60Hz AC100~240V 50/60Hz Note 1: For current input, connect an optional shunt resistance to a voltage input terminal. Note Note 2: 1: Please For current do not input, use connect any input an terminal optional which shunt is resistance not needed. to a voltage input terminal. Note 2: Please do not use any input terminal which is not needed. 7

Code Symbols PHF 4 5 6 7 8 9 10 11 12 13 1 B 1 1 - E 1 V Digit 4 11 12 Specifications <Number of input points> 3 6 <Alarm (relay) output/di input> Without With <> Without With Note 5 6 0 1 Y E Note 1: Input signals are classified into the following 4 groups. Make the setting so that channel 4 and 5 are assigned the input signal categorized in the same group. Group 1: Thermocouple (12 kinds), 50mV Group 2: Pt100. JPt100, Ni100, Cu50, Pt50 Group 3: 500mV Group 4: 1-5V, 0-5V Item Option Scope of supply Quantity Main unit 1 Panel mounting bracket 1 CD-ROM (PC software and Instruction manual) 1 Noise filter for power cable 1 Item Type Specifications Shunt resistor for DC current input PHZP0101 10Ω±0.1% PC loader communication cable PHZP1801 With USB A and USB minib Connector (3m) CD-ROM PHZP2101 Instruction manuals and softwares PC card adapter for Compact flash SDAD-38 Maker : Sandisk Compact flash (512MB) Compact flash (1GB) PHZP1301-512 PHZP1301-01G Note 1: Windows, Excel and Internet Explorer are registered trademarks of Microsoft Corporation. Note 2: SanDisk compact flash is a trademark of SanDisk. Note 3: PC98 series are registered trademarks of NEC Corp. Note 4: MODBUS is the registered trademark of AEG Schneider Autmation International. Note 5: Netscape is the registered trademark of Netscape Corp. Note 6: Mozilla Firefox is the registered trademark of Mozilla Foundation. Information in this catalog is subject to change without notice. Printed in Japan 2013-12/20FOLS A.P.O. - ELMOS v.o.s., Pražská 90, 509 01 Nová Paka, Tel.: +420 493 504 261, Fax: +420 493 504 257, E-mail: apo@apoelmos.cz, Internet: www.apoelmos.cz