C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Similar documents
C B. Models. Operating up to 5000m altitude 5 year product warranty

TEP 75WI Series, 75 Watt

TEP 100WIR Series, 100 Watt

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Universal Power Supplies

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

PXC-M06xxW Dual Output Series: DC-DC Converter Module 9 ~ 36 VDC and 18~ 75 VDC input; ±5 to ±15 VDC Dual Output 6 Watts Output Power

Enclosed Power Supplies

FDC20-48 S 05 W - HC PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Features. Regulated Converters. RP10-AW 10 Watt 1 x1 Single & Dual Output RP10- _AW/_- DC/DC Converter

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Fixed Operating Frequency Six-Sided Continuous Shield

2:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 88% Ultraminiature Open Frame SMD No Minimum Load Required

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Package (4) Control Logic (3)

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 84% Fixed Operating Frequency Six-Sided Continuous Shield

Output Voltage* (nom.)(adjustable)

Packaging (5) Protection (3) Isolation Voltage (4)

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 89% Six-Sided Continuous Shield

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

Output Voltage* (nom.)(adjustable)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Packaging (4) Isolation Voltage (3) nom. Output Voltage

DC/DC Converters. TSM Series, 1 Watt. Features. Models

12-15VDC (12V±5%) 24-28VDC (24V±5%)

MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

IEC/EN/UL60950 & CE certified, EN55032 Class B

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Switching Power Supplies

Output Current Input Current Max. capacitive Load

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

ML100SRI. Series. Ultra-Miniature, 1W High Isolation, SMT DC/DC Con vert ers. Key Features:

Universal input VAC <150mW No load power consumption

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

20W DC-DC Converter P20J-Series

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

IG480RW. Series. High Isolation IGBT Driver DC/DC Con vert ers.

Series AM1M-NZ 1 Watt DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

VP ELECTRONIQUE MASSY - Tel

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM40-G)

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

R0.5S_D ECONOLINE. Features. 0.5 Watt SMD Isolated Single or Dual Output. Derating-Graph (Ambient Temperature) DC/DC-Converter with 3 year Warranty

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Industrial Power Supplies

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

RO- S/_ Protection (3) Isolation Option (4) Single

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Protection (3) alternative Pinning Option (4) Single or Dual

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

RM- S/_ Protection (3) Isolation Option (4) Single

Series AM1S-Z 1 Watt DC-DC Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Series AM20EW-NZ 20 Watt DC-DC Converter

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

20W DC-DC Converter P20H-Series

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Safety Standards. Model Number:

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Safety Standards. Model Number:

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Safety Standards. Model Number: Unit Weight:

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Vin= 24VDC Vout= full load with normal start-up time, no external components with <1 second start-up time + diode protection circuit

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Datasheet. ACF-10 Series AC/DC Power Module 10W

Safety Standards. Model Number:

Series AM4T-Z 4 Watt DC-DC Converter

Safety Standards. Model Number:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Safety Standards. Model Number:

Transcription:

DC/DC Converter Ultra wide 4:1 input voltage 20 W DC/DC converter in a 1.6 x 1 plastic case I/O isolation 5000 VACrms rated for 250 VACrms working voltage Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP Risk management process according to ISO 14971 including risk management file Acceptance criteria for electronic assemblies according to IPC-A-610 Level 3 Low leakage current < 2.5 µa Extended operating temperature range 40 C to 80 C. EMC compliance to IEC 60601-1-2 4th edition and EN55032 class A Operating up to 5000m altitude 5 year product warranty The THM-20WI series is a range of medical 20 Watt DC/DC converters in 1.6 x 1.0 plastic package and with ultra wide 4:1 input voltage range. They provide a reinforced isolation system for 5000 VACrms isolation and a very low leakage current of less than 2.5 µa. The units are approved to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP (Means Of Patient Protection) and come along with an ISO 14971 risk management file. Design and production conform to the quality management system ISO 13485. With a high efficiency of up to 89% and highest grade components the converters can reliably operate in an ambient temperature range of 40 C up to +80 C. They constitute a reliable solution not only for medical equipment but also for demanding ranges of application such as transportation, control & measurement or IGBT drivers. C B Scheme IEC 60601-1 ES 60601-1 Models Order code* Input voltage range Output voltage Output current max. Efficiency typ. THM 20-2411WI 5.0 VDC 4000 ma 88.5 % THM 20-2412WI 12 VDC 1670 ma 88.5 % THM 20-2413WI 9.0 36 VDC 15 VDC 1330 ma 89.0 % THM 20-2415WI (24 VDC nominal) 24 VDC 833 ma 88.5 % THM 20-2421WI ±5 VDC ±2000 ma 86.0 % THM 20-2422WI ±12 VDC ±833 ma 88.5 % THM 20-2423WI ±15 VDC ±667 ma 89.0 % THM 20-4811WI 5.0 VDC 4000 ma 89.5 % THM 20-4812WI 12 VDC 1670 ma 88.5 % THM 20-4813WI 18 75 VDC 15 VDC 1330 ma 89.0 % THM 20-4815WI (48 VDC nominal) 24 VDC 833 ma 88.5 % THM 20-4821WI ±5 VDC ±2000 ma 86.0 % THM 20-4822WI ±12 VDC ±833 ma 88.5 % THM 20-4823WI ±15 VDC ±667 ma 89.0 % * suffix -A1 for remote control option with positive logic suffix -A2 for remote control option with negative logic www.tracopower.com Page 1 of 4

Input Specifications Input current no load Surge voltage (3 sec. max.) Start-up voltage Startup time Under voltage shut down (lock-out circuit) Input filter 24 Vin models: 10 ma typ. 48 Vin models: 9 ma typ. 24 Vin models: 50 V max. 48 Vin models: 100 V max. 24 Vin models: 9 VDC (or lower) 48 Vin models: 18 VDC (or lower) 60 ms max. (30 ms typ.) 24 Vin models: 7.8-8.6 VDC 48 Vin models: 15.8-17.4 VDC Pi-type Conducted noise Conducted & Radiated input suppression EN 55011 limits to IEC 60601-1-2 4th editon EN55032 class A (internal filter) EN55032 class B with external components Filter proposal www.tracopower.com/overview/thm20wi EMC immunity Generic for Medical equipment IEC/EN 60601-1-2 4th edition ESD (electrostatic discharge) EN 61000-4-2, air ±15 kv, contact ±8 kv, perf. criteria A Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A Fast transient / surge EN 61000-4-4, ±2 kv, perf. criteria A (with external input capacitor / diode) EN 61000-4-5, ±2 kv perf. criteria A 24 Vin models: 2 pcs. Nippon chemi-con KY 220 µf / 100 V 1 pcs. TVS - SMDJ58A, 58V, 3000 W) 48 Vin models: 2 pcs. Nippon chemi-con KY 220 µf / 100 V 1 pcs. TVS - SMDJ120A, 120V, 3000 W) Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A Magnetic field immunity EN 61000-4-8 100 A/m, continuous, perf. criteria A 1000 A/m, 1 sec., perf. criteria A External input fuse required (recommended values, slow blow type) Output Specifications Voltage set accuracy 24 Vin models: 4 A 48 Vin models: 2 A ±1 % max. Output voltage adjustment range 5 & 12 VDC models: ±10 % (single output models only) 15 & 24 VDC models: 10 / +20 % Regulation Input variation single output: 0.2 % max. dual output: 0.5 % max. Load variation 0 100 % single output: 0.2 % max. dual output: 1.0 % max. Cross regulation dual output: 5.0 % max. (asymmetrical load 25/100 %) Temperature coefficient Minimum load ±0.02 %/K max. not required Ripple and noise (±)5.0 VDC models: 50 mvp-p typ. with cap. 10 µf/25 V X7R MLCC (20 MHz Bandwidth) (±)12 VDC models: 75 mvp-p typ. with cap. 10 µf/25 V X7R MLCC (±)15 VDC models: 75 mvp-p typ. with cap. 10 µf/25 V X7R MLCC 24 VDC models: 100 mvp-p typ. with cap. 4.7 µf/50 V X7R MLCC Transient response Recovery time (25% load step change) 250 µs typ. Over current limitation Short-circuit protection at 150 % typ. of Iout rated (hiccup mode) at 185 % max. of Iout rated (hiccup mode) Continuous, automatic recovery www.tracopower.com Page 2 of 4

Output Specifications (continued) Overvoltage protection (±)5.0 VDC models: 6.2 VDC typ. (±)12 VDC models: 15 VDC typ. (±)15 VDC models: 20 VDC typ. 24 VDC models: 30 VDC typ. Capacitive load Single output 5.0 VDC models: 5 000 µf max. 12 VDC models: 850 µf max. 15 VDC models: 700 µf max. 24 VDC models: 220 µf max. Dual output ±5 VDC models: 2 500 µf max. (each output) ±12 VDC models: 500 µf max. (each output) ±15 VDC models: 350 µf max. (each output) General Specifications Temperature ranges Operating 40 C to +80 C Case temperature +105 C max. Storage temperature 55 C to +125 C Derating nominal input 2 %/K above 55 C Vin min. / Vin max. 1.82 %/K above 50 C Overtemperature protection Thermal impedance Humidity (non condensing) Isolation voltage (50 Hz, 60 s) Clearance/creepage Leakage current ( at 240 VAC, 60 Hz) Isolation capacitance (input/output) Altitude during operation Reliability, calculated MTBF (MIL-HDBK-217F at +25 C, ground benign) Switching frequency Vibration and thermal shock resistance at 115 C typ. 14.4 K/W typ. 5 % to 95 % rel H max. 5000 VACrms, reinforced 8 mm min. 2.5 µa max. 20 pf typ. 5000 m 1 712 000 h 225-285 khz (pulse width modulation) according to MIL-STD-810F Remote On/Off (for THM 20 -A1 / -A2 option models only) Positive logic (-A1 models) Off: short circuit or 0 1.2 VDC (referred to -Vin pin) On: open circuit or 3.5 12 VDC (referred to -Vin pin) Negative logic (-A2 models) Off: open circuit or 3.5 12 VDC (referred to -Vin pin) On: short circuit or 0 1.2 VDC (referred to -Vin pin) Off idle current 2.5 ma typ. Remote pin input current 0.5 ma min. 1 ma max. Safety standards/approvals Medical equipment ANSI/AAMI ES 60601-1:2005/(R)2012, IEC/EN 60601-1 3rd edition Certification documents www.tracopower.com/overview/thm20wi Environmental compliance Reach www.tracopower.com/info/reach-declaration.pdf RoHS RoHS directive 2011/65/EU Physical Specifications Casing material Base material Potting material Package weight Soldering temperature non-conductive plastic non-conductive plastic silicone (UL94 V-0 rated) 24 g (0.85oz) max. 265 C / 10 s All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. www.tracopower.com Page 3 of 4

Outline Dimensions 25.4 (1.00) 6 5.08 5.08 (0.20) (0.20) 2 1 2.54 (0.10) 10.2 5.6 (0.22) Pinout Pin Single Dual 1 +Vin (Vcc) +Vin (Vcc) 2 Vin (GND) Vin (GND) 3 +Vout +Vout 4 Vout Common 5 Trim Vout 6 No pin* / Remote No pin* / Remote 35.56 (1.40) 40.6 (1.60) *If remote is not selected ther will be no pin 5 4 3 2.54 Dimensions in [mm], () = Inch Tolerances ±0.5 (±0.02) ±0.25 (±0.01) Pin pitch tolerances ±0.25 (±0.01) Pin ø 1.0 ±0.1 (0.04 ±0.004) (0.10) Copyright 2018 Traco Electronic AG Specifications can be changed without notice! www.tracopower.com Rev. August 20, 2018 Page 4 of 4

Sager Electronics and its specialized group Sager Power Systems is an authorized distributor of TRACO Power and the THM series. Visit the TRACO Power page on power.sager.com for more information on their offering, or contact a Sager Power Systems representative at 1.866.588.1750 or power.sager.com for price and availability.