IBM TotalStorage DS4500 Fibre Channel Storage Subsystem Cabling Guide

Similar documents
IBM System Storage DS4700 Express Storage Subsystem Fibre Channel Cabling Guide

GB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.

System Storage DS3950 Quick Start Guide

IBM TotalStorage DS4000 Fibre Channel and Serial ATA Intermix Premium Feature. Installation Overview

Hard Drive and Storage Expansion Enclosure Installation and Migration Guide

Dell PowerVault MD3600f and MD3620f Storage Arrays. Deployment Guide

Rack Installation Instructions

Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions

E-Series Hardware Cabling Guide

Rack Installation Instructions

E-Series Hardware Cabling Guide

Rack Installation Instructions

IBM TotalStorage DS300 and DS400 Quick Installation Guide

EXN4000 Storage Expansion Unit Installation and Setup Instructions

IBM System Storage DCS3700 with Gen2 Controllers. Installation, User's, and Maintenance Guide IBM GA

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

Dell EMC PowerVault MD3860f Series Storage Arrays. Deployment Guide

IBM. Rack Installation Instructions

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DCS3860 Quick Start Guide

Dell PowerVault MD3860f Series Storage Arrays Deployment Guide

Power Systems and 5877 removal and replacement procedures

Installation, User s, and Maintenance Guide

IBM TotalStorage NAS Gateway 300 Model G27. Quick Start Instructions

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM TotalStorage DS4500 Fibre Channel Storage Server

N6000 Series Filer Installation and Setup Instructions

Installation and Support Guide for AIX, HP-UX, Solaris, and Linux on POWER

N3220 Installation and Setup Instructions

IBM TotalStorage NAS 200 Model 25T. Quick Start Instructions

N3240 Installation and Setup Instructions

Hardware Replacement Guide

Power Systems. System processor assembly

Quick Installation Guide

N3150 Installation and Setup Instructions

IBM System Storage DCS Series with Gen2 controllers. Hard Disk Drive and Storage Enclosure Installation and Migration Guide IBM GA

IBM Flex System EN Gb Scalable Switch. User s Guide

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

Installation and Support Guide for Microsoft Windows NT and Windows 2000

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Installation and Support Guide for AIX, HP-UX, Solaris, and Linux on POWER

IBM DS4000 Service Alert Setup Instructions

System i and System p. Service provider information Reference information

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6417, 6418, 6449, 6453

Power Systems. IBM Power 595 (9119-FHA) removal and replacement procedures

LSI CTS2600 Controller-Drive Tray

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

Installation, User s, and Maintenance Guide

H4 Series Hardware Replacement Guide

IBM. Setup Instructions. IBM RS/ Model 260 SA

Installing the Cisco SFS 3504 Server Switch

Installation and Support Guide for AIX, HP-UX and Solaris

ThinkCentre Hardware Installation and Replacement Guide

CSM200 Expansion Tray

Veritas Appliance Hardware Service Procedure

Installation and Support Guide for AIX, HP-UX, and Solaris

Completing Your System Installation

Connect Router to the Network

Netfinity FAStT500 RAID Controller Enclosure Unit. Installation Guide

IBM TotalStorage SAN Switch F08

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

IBM Shared Disk Clustering. Hardware Reference

IBM TotalStorage SAN Switch M12

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

StorageGRID Webscale 10.4 Appliance Installation and Maintenance Guide

Veritas Appliance Hardware Service Procedure

Installation and Support Guide for Windows 2000/Server 2003, NetWare, ESX Server, and Linux

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

Veritas Appliance Hardware Service Procedure

JanusRAID SA-6692J Hardware User Manual

DNS-2608 Enterprise JBOD Enclosure User Manual

6540 Controller Tray. Initial Setup Guide. EC E1, First Edition

EXN3000 Storage Expansion Unit Installation and Setup Instructions

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

ThinkCentre. Hardware Removal and Replacement Guide Types 8143, 8144, 8146 Types 8422, 8423, 8427

2002 Series FRU Installation and Replacement Guide

IBM. Setup Instructions. RS/ Model B50 SA

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303

Installing IBM System Storage Productivity Center

IBM FAStT Storage Manager Version 8.2 IBM. Installation and Support Guide for Novell NetWare

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

Tower to Rack and Rack to Tower System Conversion Guide

ERserver. Service provider information Service functions

3 Angled Connector Housing (MC) Installation

IBM ThinkPad USB Portable Diskette Drive. User s Guide

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

Lenovo 3000 Hardware Installation and Replacement Guide. Machine Types 7816, 7817, 7818, 7819, 9686, 9687, 9688, 9689, 9690, 9691

OCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI

The IBM Systems Storage SAN768B announces native Fibre Channel routing

IBM FlashSystem V Quick Start Guide IBM GI

IBM ThinkPad 380XD/385XD Setup Guide

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter

Installation and User's Guide

SGI InfiniteStorage 120

Installation, User s, and Maintenance Guide

Transcription:

IBM TotalStorage DS4500 Fibre Channel Storage Subsystem Cabling Guide stallation overview Table 1 summarizes the steps required to correctly install, cable, and power on your IBM TotalStorage DS4500 Storage Subsystem. Unless otherwise stated, all the following tasks are detailed in the sections referenced in the IBM TotalStorage DS4500 stallation, User s, and Maintenance Guide. Review the multilingual IBM Safety formation document and read all safety information in the DS4500 stallation, User s, and Maintenance Guide before you begin the installation. Attention: Before powering on the DS4500 Storage Subsystem, each attached storage expansion enclosure must be populated with at least two drives. If at least two drives are not installed in each attached storage, when you power on the DS4500 and its attached storage expansion enclosure(s), your standard storage partition key might be lost and must be regenerated using instructions on the IBM DS4000 Solutions and Premium Features Web site: https://www-912.ibm.com/premiumfeatures/ addition, the resulting insufficient load to the enclosure power supplies might cause them to intermittently appear as failed, falsely indicating the power supplies are bad. All drives in the connected storage (s) must contain no prior configuration data. Table 1. stallation Tasks Task Detailed Description 1 Review the DS4500 installation recommendations and requirements. Chapter 2, Handling static-sensitive devices 2 Fold down and open the sides of the shipping box. Without removing the DS4500 from box, you can remove the DS4500 rack mounting rails and hardware from the box. stall the support rails in the rack cabinet. 3 Before removing the DS4500 from the shipping box, remove the components to lighten the unit. 4 Record the serial number, machine type, model number, and RAID controller MAC addresses for your DS4500. Preparing for installation Chapter 2, stalling the support rails Chapter 2, Removing the CRUs Appendix A, Records, 5 stall and secure the DS4500 chassis in the rack cabinet. Chapter 2, stalling the DS4500 into a rack on the support rails 6 Replace the components in the installed DS4500 chassis. Chapter 2, Replacing the components 7 stall in the rack cabinet the DS4000 storage s that you plan to cable to the DS4500. 8 If there is any storage to be attached to the DS4500, use SFP modules and FC cables to cable the DS4500 to the DS4000 storage. stallation, User s, and Maintenance Guide for your DS4000 storage Chapter 3, Connecting storage s to the DS4500

Table 1. stallation Tasks (continued) Task Detailed Description 9 After you cable the DS4000 storage s, if there are EXP710 storage s in the DS4500 configuration, set their enclosure IDs. If there are EXP810 storage s in the DS4500 configuration, you do not need to set their enclosure IDs because they are set automatically by the controller. 10 For out-of-band management: Cable the DS4500 Ethernet ports to either the management workstation or to the hosts. For in-band management: Cable the DS4500 host channels to the FC HBAs in either the hosts or the FC switch that connects to the host FC HBAs. 11 Connect the power cables for the DS4500 and the storage expansion enclosures if needed. 12 Power on the attached storage s and the DS4500 storage subsystem. 13 Review the controller firmware and NVSRAM, drive enclosure firmware, ESM firmware, and Storage Manager software requirements and obtain upgrades if necessary. 14 stall the DS4000 Storage Manager 9.16 host software on the management workstation (for out-of-band management) or on the host (for in-band management). Use the DS4000 Storage Manager software to verify the configuration. Chapter 3, Storage expansion enclosure settings Chapter 3, Connecting secondary interface cables Chapter 3, Connecting hosts to the DS4500 Chapter 3, Cabling the power supply Chapter 4, Turning on the storage subsystem Chapter 1, DS4500 hardware and software compatibility IBM DS4000 Storage Manager 9.16 stallation and Support Guide for your operating system 15 Review and perform the DS4000 Health Check process. Chapter 4, Performing the DS4000 Health Check process 2

stalling an SFP module and fibre channel cable Statement 3: DANGER: Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following: Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. All host and drive cabling connections require you to use Small Form-Factor Pluggable (SFP) modules in the DS4500 host and drive channels used by the cabling connections. The SFP module housing and fibre channel cable have integrated guide keys that prevent you from inserting these devices incorrectly. You must insert SFP modules into ports with minimal pressure so that you do not damage either the SFP module or the port. You can insert an SFP module into an active port without affecting the operational loop performance. You must connect the fibre channel cable to the SFP module after you insert the SFP module into the port. Attention: Remove SFP modules from any unused mini hub ports (both host-side and drive-side) on the DS4500 Storage Subsystem. To avoid damage to your fibre-optic cables: v Do not route the cable along a folding cable-management arm. v Route the cable away from places where it can be damaged by other devices in the rack cabinet. v For devices on slide rails, leave enough slack in the cable so that it does not bend to a diameter of less than 76 mm (3 in.) or a radius less than 38 mm (1.5 in.) when extended or become pinched when retracted. v Do not use plastic cable ties in place of the provided cable straps. v Do not put excess weight on the cable at the connection point. Be sure that the cable is well supported. 1. Remove the protective caps from the SFP module and from the fibre channel cable. Do not touch the exposed fibre-optic cable. Protective cap Wire tab Protective cap Plastic tab Fibre Channel cable Protective caps 10 o 90 o SFP module SFP module Figure 1. SFP modules and fibre channel cables 2. sert the SFP module into an SFP module port on an IBM DS4500 mini hub. 3. Connect the fibre channel cable to the SFP module. 3

To remove an SFP module and fibre channel cable: 1. Remove the fibre-optic cable from the SFP module; then, replace the protective caps on the cable connector. Attention: Do not grasp the plastic tab that is part of the SFP module while disconnecting the fibre-optic cable. Pulling the SFP module plastic tab while disconnecting the fibre-optic cable might damage the SFP module. 2. For SFPs with plastic tabs, pull the SFP module plastic tab outward at a 10 angle while you remove the SFP module. The plastic tab releases the SFP module latch. 3. For SFPs with wire tabs, pull the SFP module wire tab outward at a 90 angle and remove the SFP module. The wire tab releases the SFP module latch. 4. Replace the protective cap on the SFP module. Direct-attached host-side fibre channel cabling Attention: stall the DS4500 Storage Subsystem and all storage s in the rack cabinet before cabling the configuration. Host mini hubs Drive mini hubs Controller A 1 2 3 4 4 3 2 1 Mini hub Out ports Mini hub ports Controller B Figure 2. DS4500 Storage Subsystem ports and controllers 1. Connect a host adapter to the Host 1 (top) port on host-side mini hub 1. For redundancy, connect a second host adapter to the Host 1 (top) port on the host-side mini hub 2. Note: To connect devices to each other, follow the procedure on the other side of this document for installing SFP modules and fibre channel cables. 2. For a second redundant host, connect two host adapters to the Host 2 (bottom) ports on host-side mini hubs 1 and 2. 3. For a third redundant host, connect two host adapters to the Host 3 (bottom) ports on host-side mini hubs 3 and 4. 4. For a fourth redundant host, connect two host adapters to the Host 4 (top) ports on host-side mini hubs 3 and 4. 4

Host 1, Host Adapter 1 and 2 Host 4, Host Adapter 1 and 2 Host 1 Host 4 Host 2 Host 3 Host 2, Host Adapter 1 and 2 Host 3, Host Adapter 1 and 2 Figure 3. DS4500 Storage Subsystem host adapter connections (direct-attached) For additional information about host-side cabling, refer to the IBM TotalStorage DS4500 Fibre Channel Storage Subsystem stallation, User's, and Maintenance Guide. Drive-side fibre-channel cabling The DS4500 Storage Subsystem supports up to two redundant drive loops. A redundant drive loop consists of one or more storage s connected to a controller using two sets of fibre channel cables. If one data path fails, the controller uses the other data path to maintain the connection to the drive group. 5

Drive interface ports DS4500 Storage Subsystems use only redundant drive-loop configurations. Each drive mini hub connects to Controller A and Controller B and represents a single drive loop. The drive loops must be set up in pairs to support redundant drive loop configurations (two data paths per storage ). See Figure 4 for an illustration of the drive-side mini-hub interface ports. Drive loop C and D for redundant drive loop pair 2 Drive loop A and B for redundant drive loop pair 1 4 3 2 1 Drive mini-hub ports Use one port on each mini hub to connect a drive loop cable Leave one port unoccupied for future upgrades GS000043 Figure 4. Drive mini-hub ports The maximum number of storage s that can be connected per pair of redundant drive loops depends on the IBM DS4000 storage models used. The following DS4000 storage types are supported by the DS4500 Storage Subsystem: v FAStT EXP500 v DS4000 EXP700 v DS4000 EXP710 v DS4000 EXP100 v DS4000 EXP810 If the drives are configured using only DS4000 EXP700, EXP710, EXP810, or EXP100 storage expansion enclosures, the DS4500 Storage Subsystem supports a maximum of 224 hard drives. If the drives are configured using only FAStT EXP500 storage s, the DS4500 Storage Subsystem supports a maximum of 220 hard drives. Important: Ensure that the single digit (x1) of the enclosure ID for every enclosure in a redundant drive loop pair is unique. Refer to the IBM TotalStorage DS4500 stallation, User's, and Maintenance Guide for more information on the storage IDs settings. To cable two DS4000 10- or 14- drive storage s (EXP500, EXP700, EXP710, or EXP100) to the DS4500, see Connecting to EXP500/EXP100/EXP700/EXP710 storage s on page 7. To cable two DS4000 16-drive storage s (EXP810) to the DS4500, see Connecting to EXP810 storage s on page 8. 6

Attention: If you need more information about storage cabling, including how to cable different storage s types and the latest updates, please see the IBM TotalStorage DS4500 stallation, User s and Maintenance Guide and the IBM TotalStorage DS4000 Hard Drive and Storage Expansion Enclosure stallation and Migration Guide. addition, you must purchase the FC/SATA Enclosure termix premium option to combine DS4000 EXP100s or DS4000 EXP810s with SATA enhanced disk drive modules (E-DDMs) with DS4000 EXP700s, DS4000 EXP710s, or DS4000 EXP810s with fibre channel drives in the same DS4500 Storage Subsystem configuration. Connecting to EXP500/EXP100/EXP700/EXP710 storage expansion enclosures 1. If you are cabling two EXP500/EXP100/EXP700/EXP710 storage s to the DS4500, use a fibre channel cable to connect the port on the left ESM board of the first enclosure to the Out port on the left ESM board of the second enclosure. Connect the port on the right ESM board of the first enclosure to the Out port on the right ESM board of the second enclosure. If you want to connect additional storage s into drive loops A and B, then by starting with the second storage, connect each additional storage expansion enclosure into drive loops A and B in the same manner. Leave the port on the right ESM board on the last storage in the loop unoccupied. 2. Ensure that each storage has a unique enclosure ID (switch setting). 3. From the second (or last) enclosure, connect the port on the left ESM board to the Out (upper) port on drive-side mini hub 4 on the DS4500. Leave the Out port on the left ESM board on the first enclosure and the (lower) port on the drive-side mini hub 4 unoccupied. 4. From the first enclosure, connect the Out port on the right ESM board to the (lower) port on drive-side mini hub 2 on the DS4500. Leave the port on the right ESM board on the second (or last) enclosure and the Out (upper) port on the drive-side mini hub 2 unoccupied. 7

Fourth (last) storage LeftESM RightESM EXP500/100/7x0 Third storage LeftESM RightESM EXP500/100/7x0 Second storage LeftESM RightESM Loop A EXP500/100/7x0 Loop B First storage LeftESM RightESM EXP500/100/7x0 Drive-side mini hub 4 d3nu4043d Figure 5. EXP100/700/710 storage enclosure Connecting to EXP810 storage s 1. Make sure that each EXP810 storage has the enclosure speed set to 2 Gbps fibre channel speed. 2. If you are cabling two EXP810 storage s to the DS4500, use a fibre channel cable to connect port 1B on the ESM A board of the first enclosure to port 1A on the ESM A board of the second enclosure. Connect port 1A on the ESM B board of the first enclosure to port 1B on the ESM B board of the second enclosure. If you want to connect additional storage s into drive loops A and B, then by starting with the second storage, connect each additional storage expansion enclosure into drive loops A and B in the same manner. Leave port 1A on the ESM B board on the last storage in the loop unoccupied. 3. From the second (or last) enclosure, connect port 1B on the ESM A board to the Out (upper) port on drive-side mini hub 4 on the DS4500. 8

Leave port 1A on the ESM A board on the first enclosure and the (lower) port on the drive-side mini hub 4 unoccupied. 4. From the first enclosure, connect port 1B on the ESM B board to the (lower) port on drive-side mini hub 2 on the DS4500. Leave port 1A on the ESM B board on the second (or last) enclosure and the Out (upper) port on the drive-side mini hub 2 unoccupied. The EXP810 enclosure IDs will automatically set to give each enclosure in the drive loop a unique enclosure ID. Fourth storage ESM A ESM B EXP810 Third storage ESM A ESM B EXP810 Second storage ESM A EXP810 ESM B Loop A First storage ESM A EXP810 ESM B Loop B Drive-side mini hub 4 Drive-side mini hub 2 ds4500_8107 Figure 6. EXP 810 storage 9

Trademarks The following terms are trademarks of ternational Business Machines Corporation in the United States, other countries, or both: IBM TotalStorage Other company, product, or service names may be trademarks or service marks of others. Second edition (October 2006) Copyright ternational Business Machines Corporation 2006. All rights reserved. US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. GC26-7813-01 (1P) P/N: 42D3303