INCA-FLOW V4.6 - What s new? Guided Calibration for INCA

Similar documents
Release Notes INCA-FLOW V4.6. Release Notes. Page 1 of 12

Release Notes INCA-FLOW V4.4. Release Notes. Page 1 of 13

INCA-EIP V7.2 User s Guide

INCA-EIP (Experimental Target Integration Package) V7.0.2 User s Guide

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

Virtualizing the TCU of BMW's 8 speed transmission

IPEaddon_INCA_V07_02_00

Product Information ES582.1 Compact USB Device

ETAS ASCMO 5.2 Release Notes. Release Notes. Page 1 of 12

Simulation-based development of automotive control software with Modelica


GUIDE TO USE DYNOHELL SOFTWARE

ETAS ASCMO MOCA V5.1 User's Guide

INCA V7.2 Getting Started

RaySafe X2 View USER MANUAL

Product Information ES582.1 Compact USB Device

Set-up programming Toyota Parking Aid 800

INCA-FLEXRAY V6.2. User Manual

INCA-FLEXRAY V7.2 User Manual

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

iobd2 MFi BT VAG Adapter User Manual

Draft Amendments to the Fuel Economy Test Method for Motorcycles

Measuring Everything. White Paper

vcdmstudio Product Information

EHOOKS V4.0 PRE-RELEASE

EHOOKS V4.3 User Guide

Ready, Set, Go! Measuring, Mapping and Managing with XIL API 2.0

This Support Note describes how to configure the trace window to analyse CCP or XCP communication in CANape.

RoboAGVSim AGV Simulator User Manual

Using Vector CANape with Raptor New Eagle Products, Inc.

Thank you for Purchasing a OVTune EcuTek Calibration four your 2016 Mazda MX5 ND

INCA-MIP V16.1 for INCA V7.2 User s Guide

INCA-SIP User s Guide

A MATLAB Toolbox For ASAM MCD-3MC And ASAM MCD3 Measurement & Calibration Automation

IMS Messsysteme GmbH Heiligenhaus

CANape ASAM-MCD3 Interface Version Application Note AN-AMC-1-103

INCA-ES9xx V7.0.2 Release Notes

MDA V8.2.x What s New Functional Enhancements & Usability Improvements (V8.2.0 V8.2.2)

Modas Sport. Quick Start English V

ES6xx Add-On & Hardware Configuration Tool V1.4.0

Model Based Development of a Light Function for a Rapid Prototyping System. Prof. Dr. Dieter Nazareth

Included in this GSB is information on the following GSM topics:

IPEmotion_PlugIn_WAGO_V01_03_01

INCA-FLOW Getting Started

INCA ASAM ASAP3 Interface. User's Guide November 2010

Quick Reference Card. Setting up the FmX Integrated Display with the Autopilot System

Automated test of the AMG Speedshift DCT control software

Real and Virtual Development with SystemDesk

INCA-MIP V16.0 for INCA V7.1 User s Guide

DIGITRONIC MULTIPOINT AUTOCALIBRATION MANUAL

Cluster Simulation with Integrated Workflow and Test Management. Chandu Puliroju dspace Inc.

Diesel Particulate Filter DPF Service Regeneration Table 1: Service Regeneration Successful Table 2: Service Regeneration Unsuccessful

MultiHandy Operating Instructions. Version 1.0 EN Firmware-Version 1.0 TKZ L EN

LABCAR-OPERATOR V5.4.2 Getting Started

Research Article. ISSN (Print) *Corresponding author Chen Hao

Design Verification and Calibration Based on Physical Measurements for Electrical Vehicles

K-IMS. for Office. (Kawasaki-Integrated Maritime Solutions) Advanced Technology Group

IPEmotion_PlugIn_PROFIBUS_V01_01_00

Technical Information

Hardware-In-Loop Test Setup Automation

Automation functions and their licensing

ADVANCED MODELING AND OPTIMIZATION FOR VIRTUAL CALIBRATION OF INTERNAL COMBUSTION ENGINES

ASAM ASAP3 Interface User s Guide

The Mobile Combustion Analyzer from Kistler. KiBox T o Go -Präsentation hoe March 09 1

INCA-LIN V6.2. User Manual

ASCET Rapid Prototyping V6.4 User s Guide

MDA v7.2.3 Release Notes. MDA v Release Notes. Release: December Page 1 of 13

AiM User Manual. ECU Bridge. Release 1.09

ASAM ASAP3 Interface User s Guide

Anticipatory Shifting Optimization of a Transmission Control Unit for an Automatic Transmission through Advanced Driver Assistance Systems

ODX-LINK V1.5 ODX-FLASH V1.5 User s Guide

Index. v1.02

Needless Torque Calibrations

Chris Frey May 3, 2013 ECET - CPET 491 Senior Design Project Phase II Project Advisor and Instructor: Professor Paul I. Lin

Extensive Test of Heavy-Machinery ECU on a NI VeriStand HiL using TestWeaver

INCA-VLINK V1.3 Getting Started

Virtualization of Heterogeneous Electronic Control Units Testing and Validating Car2X Communication

vsignalyzer Product Information

ES Arbitrary Signal Generator PCIe Board User s Guide

News about ECU-TEST 7.0

the bridge between Vehicle Component and ECU Development

Race Studio 2. Race Studio 2 Configuration User s manual. Race Studio Configuration: user s manual 1

Release Notes INCA-RDE V1.0. Release Notes. Page 1 of 11

Block number: 00 Interface version: 4A Date: Checksum: 7500 Deployment Non-Deployment

ARES. User s Guide. Aprilia Racing Engine Setup. English version

MDA V8.2 User's Guide

Current shipped hardware state: B012/01 Current released firmware version: HSP Department NE/EHE3. Date Released:

Decoupling Test Cases from Real and Virtual Test Systems with ASAM HIL API

LCU-ONE CAN connected to MXL QM and EVO3 QM User Manual

Ideation for Telematics, Highly Automated Driving Armin Rupalla

ASCET-SE V6.3. EHOOKS Target User Guide

What s new in ASAM AE HIL API V1.0.0?

Getting Started Guide. New Eagle Products, Inc. May 13, 2013

Soft-Engine - Data store software: Version 8

Version 2.031, Firmware doesn't contain all listed features and fixes is the proper one

Design and Analysis of a Controller from System Design Idea to AUTOSAR Architecture with Basic Software Modules

Maxi-K. Installation and user manual 1.16 English

Using LCS Help. In This Section

Tutorial 1 Getting Started

06 YZF-R6. The Performance Edge. FI MATCHING SYSTEM INSTRUCTION MANUAL Ver1.11. for excellent riders

Transcription:

INCA-FLOW V4.6 - What s new? Guided Calibration for INCA

INCA-FLOW V4.6 New Features New Features 1 New base methods for ASCMO remote control 2 Get software and dataset name 3 Online TDT Analysis 4 WLTC cycle generation with gearshift calculation 5 Possibility to use global reference names for signals 6 Improvement in TDT measurement analysis functions and EDT viewer 2 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

New base methods for ASCMO remote control ASCMO close: closes the ASCMO interface ASCMO Load ExpeDes: loads a defined ASCMO ExpeDes project With this method, one can load and configure an existing ExpeDes project. Allows the mapping of INCA-FLOW elements to DoE-inputs and outputs and the definition of the operating point values for the DoE plan ASCMO can run optionally in silent mode without window. One can also define to stop the DoE after a number of blocks have been executed 3 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

New base methods for ASCMO remote control ASCMO Next experiment: This method reads the next experiment values from the DoE plan, assigns them to the respective calibration elements and exits to the True exit until there are no more experiments. Block Id: returns the current block id Experiment No.: returns the current experiment number Execute ASCMO command: With this method, one can directly execute an ASCMO command. See the ASCMO API documentation for further command descriptions. Command: the ASCMO command string 4 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

New base methods for ASCMO remote control ASCMO Train model: With this method, the ASCMO model training will be executed and the loo error values are reported back for each model output. This may be done in silent mode without a window. The training can also run in background, so the INCA-FLOW process can continue while the model is calculated. A notification variable can then be used to detect if the calculation is finished. Further documentation about model training can be found in the ASCMO manual. 5 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

New base methods for ASCMO remote control ASCMO Write matrix: Writes an INCA-FLOW element into an ASCMO variable ASCMO variable: the name of the ASCMO variable Element: the source INCA-FLOW element ASCMO Read matrix: Reads an ASCMO variable into an INCA-FLOW element ASCMO variable: the name of the ASCMO variable Target element: the target INCA-FLOW element 6 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

Get software and dataset name Device: defines the name of the INCA device Software name: defines the name of the software (e. g. A2L, S19 File) Dataset name (RP): defines the name of the dataset (e. g. Hex file) for the reference page Dataset name (WP): defines the name of the dataset for the working page Get full path: defines the full path in INCA, e. g. \RooDir\A2l\Master\SW.hex instead of SW.hex. 7 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

Online TDT Analysis The online TDT Analysis allows an online mode signal evaluation from the vehicle s sensors and additional external sensors, while in the offline mode saved measurement files are analysed. Filters or logical operations are used to extract certain signal characteristics or trigger events. File -> Load settings: loads a defined setting of this method File -> Save settings: saves a defined setting of this method File -> Load signals from MDF: Opens a defined MDF signal to read the respective measurement data for offline evaluation File -> Export A2L & HEX: exports the A2L and Hexfile with the respective inand output parameter for the online evaluation; has to be imported in the respective INCA project setting 8 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

Online TDT Analysis Signal assignment: The user defines which input parameter (e. g. from a measurement file or the measurement parameter from an A2L file) will be assigned to the respective input parameter for the TDT online/offline evaluation. This is necessary to perform the evaluation calculation. The user can map the respective ECU parameter e. g. for pedal position with the input of the TDT online analysis which would be in this case INPUT_Sig_AccPed. Online: defines if this method is used online or offline Output file: defines the name of the recorded measurement file (*.mdf) after data evaluation XCP port: Allows the definition of the XCP port communication during online evaluation 9 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

Online TDT Analysis Defines which criteria should be evaluated and recorded Defines certain predefinition for the evaluation analysis of the TDT algorithm like transmission type, front, rear or all wheel drive 10 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

WLTC cycle generation with gearshift calculation Defines the use of WLTC drive cycle Defines the vehicle class (depends on the vehicle weight and size) Test mass (kg): defines the vehicle mass Rated engine power (kw): maximum engine power of the vehicle Rated engine speed (rpm): maximum engine speed of the vehicle Idle engine speed (rpm): idle speed of the vehicle (warm engine) Defines the n (rpm) to v (km/h) ratio of the vehicle for different gears Downscale cycle: defines the possibility to downscale the cycle values, if the maximum vehicle speed or power is not sufficient for driving the normal drive cycle Use extra high part: allows the possibility to drive NOT the 2. high speed phase Calculate gear shifts: defines if gear shift calculation should be performed f0, f1 and f2: defines the road load coefficient of the vehicle (usually used at roller test benches) Defines the full load power curve of the vehicle; ASM: Correction factor for the power calculation of the full load power curve 11 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

Possibility to use global reference names for signals with MDF Read Allows the use of Global References for the evaluation of measurement data. The assignment of Global References will be performed in the hierarchy Assign project elements as known when defining measurement parameter to be read online via INCA 12 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

Improvement in Improvements in EDT viewer and TDT measurement analysis functions TDT Analysis function New event Load Change General improvements o MDF4 support o Im- and export functionality Mapping: o Signal selection with Wildcards o Signal-/Parameter description o Renaming of Defaults in Expert Settings Improvement in manual documentation Tool-Bar for Zoom and Pan EDT viewer Showing data point values as tool-tip 13 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,

INCA-FLOW: Guided calibration with INCA Thank you for your attention Please visit: http://www.etas.com/de/products/inca_software_products.php for more information Contact: Dipl.-Ing Rajesh Reddy Rajesh.Reddy@etas.com Product Manager Measurement, Calibration & Diagnostics 14 Public ETAS GmbH December 2018 ETAS GmbH 2018. All rights reserved, also regarding any disposal, exploitation, reproduction,