Measurement Accuracy of Vector Network Analysis. Thilo Bednorz

Similar documents
laboratories and production environments.

Lecture 10. Vector Network Analyzers and Signal Flow Graphs

TTR500 Series Vector Network Analyzers Demonstration Guide

New Features in Firmware V2.02 (Compared to V2.01) New Features in Firmware V2.01 (Compared to V2.00)

Practical hints: splitter characterization. J. Ruefenacht, M. Wollensack, J. Hoffmann, M. Zeier

Adapter characterization up to 110 GHz

HP 8714B Calibration

3.5mm VNA Calibration Kits

2.92mm VNA Calibration Kits

Techniques for Precise Measurement Calibrations in the Field

Multiport Testing with CMT VNAs and Off-the-shelf RF Switches

VNA0440 VNA0440e VNA0460 VNA0460e User Manual Version 3.0

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Crosstalk Measurements for Signal Integrity Applications. Chris Scholz, Ph.D. VNA Product Manager R&S North America

TN Vector Network Analyzer Calibrations and Their Effect on Measurement Results. Bernie McDermott. May 2010

SAS-2 Zero-Length Test Load Characterization (07-013r7) Barry Olawsky Hewlett Packard (8/2/2007)

R&S ZN-Z15x Calibration Units User Manual

Agilent PNA Series Microwave Network Analyzers

Field Calibration Software

Keysight Technologies PNA Series Microwave Network Analyzers

R&S ZN-Z5x Calibration Units User Manual

*Note: Operation beyond this range is possible, but has not been characterized. PART. Maxim Integrated Products 1

White Paper. Abstract

RF Probing With Rohde & Schwarz ZNB VNA. PacketMicro, Inc Wyatt Drive, Suite 9, Santa Clara, CA

GT Micro D High Speed Characterization Report For Differential Data Applications. Micro-D High Speed Characterization Report

Agilent RF Network Analyzers PNA Series

Advanced Test Equipment Rentals ATEC (2832) Manual Supplement. Agilent E5070B/E5071B ENA Series RF Network Analyzers

Copyright ANRITSU. All rights reserved.

Agilent PNA Series Microwave Network Analyzers

TNC VNA Calibration Kits

What We Do. Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces. Fully automate for: Speed, Accuracy, Ease of Use

Copyright ANRITSU. All rights reserved.

Calibration kit coefficients -the saga continues

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

AKELA Vector Network Analyzer (VNA) Quick Start Guide

100BASE-T1 EMC Test Specification for ESD suppression devices

RF Characterization Report

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

ISL MMIC Silicon Bipolar Broadband Amplifier. Features. Ordering Information. Applications. Typical Application Circuit

A simple method to characterize and accurately remove the effects of push-on connectors. O.J. Danzy Application Engineer

ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B

Agilent Technologies Advanced Signal Integrity

LeCroy SPARQ S-Parameter Measurement Methodology

Agilent Technologies S-Parameter and TDR Impedance Measurement Solution Summary

CGH W, RF Power GaN HEMT APPLICATIONS FEATURES

PXI Vector Network Analyzer

CGH40006S. 6 W, RF Power GaN HEMT, Plastic APPLICATIONS FEATURES

DATASHEET ISL Features. Applications. Ordering Information. Typical Application Circuit. MMIC Silicon Bipolar Broadband Amplifier.

Agilent ENA RF Network Analyzer

FieldFox N9923A RF Vector Network Analyzer

Keysight M937xA PXIe Vector Network Analyzer Modules

Connector Repeatability of Type-N Coaxial Adapters

DATASHEET ISL Features. Applications. Ordering Information. Typical Application Circuit. MMIC Silicon Bipolar Broadband Amplifier

The compiled VNAView application for Macintosh requires: The NI-VISA driver. LabVIEW 2014 runtime engine. VNAView application.

Dimensions (inch) 3.74 x 1.45 x.95. PMA1-08S 70 MHz -10 GHz Inline Power Monitor with SMA Connectors 1

Keysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests

Characterizing Your PLL-based Designs To Manage System Jitter. Agilent Technologies

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

Dimensions (inch) 3.74 x 1.45 x.95. PMA1-03S 70 MHz - 3 GHz Inline Power Monitor with SMA Connectors 1

= 25 C) of Demonstration Amplifier. Parameter 500 MHz 1.0 GHz 1.5 GHz 2.0 GHz 2.5 GHz Units. Small Signal Gain

Software Release Notes

PNA Family Microwave Network Analyzers

POL-001 Fiber-Optic In-Line Polarizer. Operation Manual

Lab Introduction & Network Analyser Basics

MAX2009/MAX2010 Evaluation Kits

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

ABSORBER FOAM CHARACTERIZATION FOR PREDICTING OVERALL ANECHOIC CHAMBER PERFORMANCE

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements

RClamp0521PA. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

RF Characterization Report

AT-31011, AT Low Current, High Performance NPN Silicon Bipolar Transistor. Data Sheet. Description

Low Current, High Performance NPN Silicon Bipolar Transistor. Technical Data AT AT-32033

GainMaker Amplifier Accessories

DisplayPort Testing Challenges

Limiters Detectors Switches, Switch Matrices Attenuators Phase Shifters Directional Couplers Power Dividers Integrated Assemblies.

PVA-PTS PHY Performance Test Suite

User s and Service Guide

RClamp0501T. Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics.

Keysight Technologies E5080A ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

spinner Measurement & Calibration equipment for network analyzers

Lightning 37xxxE Series Vector Network Analyzer

Tektronix Innovation Forum

InfiniBand Trade Association

RClamp0502B. Ultra-Low Capacitance TVS for ESD and CDE Protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

March 15-18, 2015 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive Session 8

GC4701-6LP Datasheet RoHS-Compliant Control Devices DC 15 GHz Surface Mount Limiter PIN Diode

AOZ8102. Ultra-Low Capacitance TVS Diode Array. Features. General Description. Applications. Typical Application

S3101 Cable & Antenna Tester Datasheet

CARSON, CA

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

RClamp1502B. Ultra-Low Capacitance TVS for ESD and CDE Protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

CHAPTER 7 Copper Cable Testing

Program Title: Telecommunication Engineering Technology Postsecondary Number: (AS) (AAS

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

Agilent 86121A WDM Channel Analyzer

S2 Family Reversing 2-port VNAs of Planar, S, and Cobalt Series

Quality Control of Headphones

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

Transcription:

Measurement Accuracy of Vector Network Analysis Thilo Bednorz EDICON 2019

VNA Measurement and Accuracy Error sources occuring with VNA measurement measurement errors stochastic errors systematic errors l l Unpredictable No correction l Errors due to limited performance of the VNA and test setup l Mismatch of the test ports l l l l Signal to noise Compression of the receiver Stability of instrument Stability and repeatability of test setup l l Transmission errors due to losses of the testset Can be reduced by system error correction ( user calibration ) 2

Stochastic Errors Setup: ı Repetability of the connectors ı Phase and magnitude stability of the cables Instrument ı Compression ı Thermal drift ı Noise ı Repeatability ı Stochastic errors are not predictable and cannot be reduced by error correction methods ı They can only be reduced by improved hardware for steup and instrumentation 3

What indicates Accuracy in the Data Sheet ı Measurement Accuracy Conditional guidance based upon specific criteria ı Effective System Data RF instrument parameters (such as directivity, port matching, tracking), after applying the system error calibration and correction. Depends on the instrument, setup parameters and calibration kit ı Factory calibrated system data Default effective system data using a calibration stored in the factory ı Raw Performance of the test ports Directivity Source Match Reflection Tracking Transmission Tracking Load Match The uncorrected HW properties, which take effect to the physical power waves It is the physical match the DUT sees during the measurement 4

Data Sheet Measurement Accuracy: Transmission measurement accuracy after Calibration Curve gives typical value: better than specified from table above 5

What Accuracy in the Data Sheet means ı Well matched DUT, no errors due to port mismatch ı Main error sources are Compression Linearity, A/D converter errors Noise linear region compression noise 6

Data Sheet effective System Data Effective system data depend on ı Quality of calibration ı Used calibration technique ı Instrument settings of ZNA calibration kit 7

Data Sheet Factory calibrated System Data 8

Data Sheet raw Test Port performance: ı Has low impact on the accuracy after full error calibration ı Impacts parameters that are not effected by error model Harmonics Spurios (e.g. mixer) 9

Sytematic Errors for Reflection Measurements Error due to Directivity Error due to Test Port Match ZVx receiver ZVx source ZVx receiver ZVx source Directivity D Measurement signal r Measurement signal r Test port match DUT ideal Termination DUT Short or Open 0,01 0,056 r D 0,046 0,066 Reflection Measurement 3 error terms: D := Directivity :=Port Match T := Transmission loss 10

Error Estimation for Reflection Measurements ZVx receiver ZVx source Directivity D - 23,6 db Measurement signal r - 25 db -26.7 db f 3.1dB 0,01 0,056 r D 0,046 DUT 0,066 DUT return loss: -25 db (= 0,056) Directivity of bridge: 40 db (=0,01) Min. value: 0.056-0.01 = 0.046 (-26.7 db) Max. value: 0.056 + 0.01 = 0.066 (-23.6 db) Measurement uncertainty: -1.7 db to 1.4 db 11

Error Estimation Example ı Directivity 40 db ı Match DUT 20 db ı Error 0.9 db pk-pk ı Error estimation via graph ı General error estimation using the table Error signal 20 db below the measurement signal results in an error of 1 db pk-pk Error signal 40 db below the measurement signal results in an error of 0.1 db pk-pk (not on the table) 12

Systematic Errors of a Measurement in forward Direction ı Typical error terms: Directivity D Transmission tracking T Reflection tracking T Source match Load match b`1 Cross talk X F ı Error terms are described by error matrices (VNA assumed to be ideal ) ı Task of System Error Correction: Evaluation of error terms for correction of measurement data Error signals for a transmission measurement 13

Example: Calibration for Reflection measurements NWA ideal reflectometer a 1 error two port of the SWR bridge TD 1 S b 2 DUT r R : value of the DUT r : measured value b r' a 3 1 T D 1 r S r b T D a T b r 3 b 3 2 1 2 1 2 b a b S r T a 2 Applying 3 known calibration standards generates 3 equations with 3 unknown (error) parameters T, D, S, e.g. Open, Short and Match 14

Types of Calibration Techniques 15

Types of Calibration Techniques ı Normalization Transmission and reflection normalization ı One Path Two Port (OSM + Normalization) For unidirectional test setups (e.g. pre-amplifier in the test set) ı Full One Port Calibration (OSM) Allows corrected reflection measurements (S11, S22) ı Full Two Port Calibration Bidirectional, corrects for all error terms Allows corrected measurement of all S-parameters Highest accuracy 16

TOSM - Classical Full Two-Port Calibration Forward measurement error two-port A 1 a 1 a 1 F S 11A S 22A b 1 S F 12A b 1 X F DUT S 21 S 11 S 22 S 12 ideal two-port network analyzer error two-port B b 2 S F 12B F b 2 S 22B a 2 ı Extension of the one port error model by 3 additional error terms for transmission measurement => 6 error terms ı Similar model for forward and reverse direction. 12-term error model (TOSM) Reverse measurement b 1 error two-port A R S 22A S R 12A a 1 b 1 DUT S 21 S 11 S 22 S 12 b 2 a 2 error two-port B S R 12B R R S 22B S 11B 1 b 2 a 2 ı Disregarding crosstalk: Reduction to 10-term model ı Frequently used due to historical reasons X R ideal two-port network analyzer 17

TOSM - The classical Calibration Technique T ı T = Through (50, el. length) ı O = Open (el. length, capacities, loss) ı M = Match (50 ) O S ı 10 Error terms 10 known Parameters 2 by Open P1; P2 2 by Short P1;P2 2 by MatchP1;P2 4 by Through P1-P2 M 50 Characteristics of all standards required Through standard assumed ideally matched Effective Load match limited to match of the Through 18

Calibration Techniques with 3 Standards a 1 a 1 b 2 b 2 S 21A S 21 S 12B S 11A S 22A S 11 S 22 S 22B S 11B error two-port A DUT error two-port B b 1 1 b 1 S 12 a 2 S 21B a 2 ideal two-port network analyzer Error model with only 7 error terms Provided by all ZVA, ZVB, ZVT 19

TOM Calibration T ı T = Through (50, el. length) ı O = Open (el. length, capacities, loss) ı M = Match (50 ) O M 50 ı 7 Error terms 7 known Parameters 2 by Open P1; P2 2 by MatchP1;P2 4 by Through P1-P2 => more parameters applied than needed Characteristics of all standards necessary 20

TRM - Calibration Technique reduced Number of Standards & Parameters T R M 50 ı T = Through (50, el. length) R = Reflect M = Match (50 ) ı Calibration with unknown calibration standard R ı Standard R may be unknown, but must be identical for both ports ı especially suitable for test fixtures 21

TRL - Calibration Technique for highest Directivity T ı T = Through R = Reflect L = Line (50 ) R L 50 ı Calibration with unknown calibration standard R. ı Standard R may be unknown, but must be identical for both ports ( reflection symmetry ) ı Impedance of the line defined by mechanical parameters, typically very accurate 22

UOSM: New Cal-Technique & Adapter Removal ı Effort similar to TOSM ı Unknown (but reciprocal) THROUGH means S21 = S12 ı Loss, repeatability and mismatch of Through do not effect the accuracy ı Provides better effective load match than TOSM ı Purpose & Advantages No data of THROUGH required Any passive and cheap adapter can be used Ideal for DUTs with different adapter types Used as Adapter Removal 23

Differences of the Calibration Techniques ı Full two-port calibration has highest accuracy UOSM and TRL provide highest accuracy Corrects for all systematic errors Measures the DUT in forward and reverse direction Recommended for measurements in the small signal (linear) range ı One-path two-port considerably accurate Corrects for mismatches between VNA output and DUT input and the transmission tracking Measures DUT in forward direction only (S11 and S21) => twice as fast as full two-port calibration Recommended for high power applications e.g. with attenuator at port 2 ı Normalization Corrects for loss only( Ripple due to mismatch errors) 24

Models of Calibration Standards Equivalent circuit model for Open Short Match ı Typically used especially for mid range and low budget kits S-parameter model ı Definition by *.s1p or *.s2p file ı Provides most accurate description of the standards ı Accuracy does not depend on quality of standard (e.g. match) but on the accuracy used for the characterization ı TOSM and UOSM as accurate as TRL 25

Application & Examples TRM vs TSM and TOM ı Ripples with TSM, TOM ı Reason: Limited validity of the model description for Open and Short ı TRM requires only symmetry of the Short at Port 1 and Port 2 Use same Short standard at both ports 0.05 db/ ı Better effective load match with TRM ı Flat frequency response with TRM TSM TOM TRM 26

Comparison 1-path two port - full two-port Small signal Large Signal (1 db compression) Trc1 S21 db Mag Trc2 S21 db Mag S21 13.686 0.1 db / Ref 13.286 db Ch1 Cal int 0.1 db / Ref 13.286 db Ch2 Ca? M1 M1 4.216000 GHz 13.292 db 4.500000 GHz 13.070 db 1 Trc1 Trc2 S21 12.852 S21 db Mag 0.1 db / Ref 12.452 db Ch1 Cal int S21 db Mag 0.1 db / Ref 12.452 db Ch2 Ca? M1 M1 4.216000 GHz 12.646 db 4.500000 GHz 12.449 db 1 13.586 13.486 13.386 13.286 13.186 M1 Red full 2-port Blue 1-path 2-port 12.752 12.652 12.552 12.452 12.352 M1 M1 13.086 M1 12.252 12.986 12.152 12.886 12.052 Ch1 fb Start 4 GHz Ch2 fb Start 4 GHz 5/18/2015, 11:53 AM Pb -20 dbm Pb -20 dbm Stop 5 GHz Stop 5 GHz Ch1 fb Start 4 GHz Ch2 fb Start 4 GHz 5/18/2015, 11:53 AM Pb -5 dbm Pb -5 dbm Stop 5 GHz Stop 5 GHz S12 and S22 differ between forward (large signal) and reverse (small signal) measurement of the DUT => forward and reverse error models are not valif for full-two port calibration 27

Comparison 1-path two port - full two-port ı Attenuator at port 2 of VNA ı Improved test port match ı Minimized error terms in reverse direction ı Same accuracy a full two port calibrated measurement Trc1 S21 db Mag 0.1 db / Ref 13.286 db Trc2 S21 db Mag 0.1 db / Ref 13.286 db S21 13.686 13.586 13.486 13.386 13.286 13.186 M1 M1 Ch1 Cal Math Smo Ch2 Cal Smo M1 M1 4.216000 GHz 4.216000 GHz 1-path 2-port with attenuator Full 2-port w/o attenuator 1 13.373 db 13.395 db 13.086 12.986 12.886 Ch1 fb Start Ch2 fb Start 5/18/2015, 12:12 PM 4 GHz 4 GHz Pb Pb -20 dbm -20 dbm Stop 5 GHz Stop 5 GHz 28

What is the best way to calibrate ı Use calibration kit based on S-parameters Directivity is not limited to physical return loss of Match standard Defined by the accuracy of the *.s1p file of the Match Source port match does not depend onvalidity of the equivalent circuit model of Open and Short Defined by the accuracy of the *.s1p file of Open and Short ı Use UOSM Load port match is not limited to the return loss of the Through but defined by the reciprocity and the quality of the 1-port standards UOSM calibration reaches the quality of a TRL calibration 29

END 30