MGate 5105-MB-EIP Quick Installation Guide

Similar documents
MGate 5111 Quick Installation Guide

MGate 5118 Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide

NPort 5100 Series Quick Installation Guide

Serial/Ethernet Converter

NPort 5400 Series Quick Installation Guide

NPort 6150/6250 Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide

NPort 5200 Series Quick Installation Guide

NPort 6600 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide

MGate 5105-MB-EIP Series

NPort W2150A/W2250A Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide

MGate 4101-MB-PBS Series

Modbus TCP/RTU Gateway

Features and Benefits. Certifications

ICF-1150 Series Quick Installation Guide

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

MGate 5102-PBM-PN Series

UC-8410A Quick Installation Guide

UPort 1200/1400/1600 Quick Installation Guide

MGate 5103 User s Manual

V2403 Quick Installation Guide

MGate 5109 User s Manual

Features and Benefits. User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors.

Features and Benefits. Certifications

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

MGate MB3000 Modbus Gateway User Manual

UPort 1200/1400/1600 Quick Installation Guide

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

MGate MB3000 Modbus Gateway User s Manual

MGate MB3000 Modbus Gateway User s Manual

UC-7101 Hardware User s Manual

NPort 5400 Series. 4-port RS-232/422/485 serial device servers. Network-Readiness for up to Four Serial Devices

iologik 2500 Series Quick Installation Guide

TCF-142-RM Series Hardware Installation Guide

SunSpec Reference Architecture SunSpec CEA 2045 Inverter Adaptor

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

Features and Benefits. Certifications

IMC-101 Series Quick Installation Guide

EDS-G205-1GTXSFP Quick Installation Guide

UC-2100 Series Hardware User s Manual

UC-7112-LX Plus/UC-7112/UC-7110 Hardware User s Manual

EDS-205A/208A Series Quick Installation Guide

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

MGate 4101-MB-PBS Modbus Serial-to-PROFIBUS Slave Gateway User s Manual

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

IA240/241 Hardware User s Manual

NPort Z2150/Z3150 Series

IMC-101G Series Quick Installation Guide

EDS-308/309 Series Quick Installation Guide

EDR-810 Series Quick Installation Guide

DT Desktop Series

TN-5308 Quick Installation Guide

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Features and Benefits. Compact design for easy installation. Certifications

MGate 5105-MB-EIP User s Manual

EDS-G308 Series Quick Installation Guide

ICF-1180I Series Quick Installation Guide

ABC-02-USB Quick Installation Guide

NPort 5200 Series. 2-port RS-232/422/485 serial device servers. Specifications. Serial-to-Ethernet Device Servers

Features and Benefits. Certifications

MGate 5105-MB-EIP User s Manual

NPort Z2150 User s Manual

UPort TM 1100 Series Quick Installation Guide

CP-114EL/CP-114EL-I Quick Installation Guide

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

MGate 5105-MB-EIP User s Manual

NPort 5100A Series. 1-port RS-232/422/485 serial device servers. Overview. A Greener Serial-to-Ethernet Solution

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

Features and Benefits. Certifications

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

UC-7400 Plus Hardware User s Manual

Features and Benefits. Fast 3-step web-based configuration. Certifications

DA-820 Series Quick Installation Guide

Moxa TCC-100 Series Hardware Installation Guide

MPC-2150 Series Quick Installation Guide

Moxa Industrial Media Converter

NPort 5000AI-M12 Series

Feature and Benefits. Certifications

TCF-142 Quick Installation Guide

EDR-G902/G903 Quick Installation Guide

EDS-405A/408A Series Quick Installation Guide

Features and Benefits. SNMP MIB-II for network management. Certifications

IKS-G6524A/G6824A Series Quick Installation Guide

EDS-308/309 Hardware Installation Guide

EDS-405A-PTP Series Hardware Installation Guide

Moxa ToughNet Switch

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

TRC-190 User s Manual

UPort TM 200/400 Series Quick Installation Guide

EDS-405A/408A Series Quick Installation Guide

Moxa TCC-100 Series User s Guide

EDS-505A/508A Hardware Installation Guide

Features and Benefits. Certifications

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

USB Connectivity. USB Connectivity

NPort 5600 Series. 8 and 16-port RS-232/422/485 rackmount serial device servers. Overview. Serial-to-Ethernet Device Servers

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Transcription:

MGate 5105-MB-EIP Quick Installation Guide Edition 2.2, March 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa India: Tel: +91-80-4172-9088 Fax: +91-80-4132-1045 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Asia-Pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 2019 Moxa Inc. All rights reserved. P/N: 1802051050011 *1802051050011*

Overview The MGate 5105-MB-EIP is an industrial Ethernet gateway for Modbus RTU/ASCII/TCP and EtherNet/IP network communications. Package Checklist Before installing the MGate 5105-MB-EIP, verify that the package contains the following items: 1 MGate 5105-MB-EIP gateway 1 serial cable: CBL-RJ45F9-150 Quick installation guide (printed) Warranty card Please notify your sales representative if any of the above items are missing or damaged. Optional Accessories (can be purchased separately) CBL-F9M9-150: DB9 female to DB9 male serial cable, 150 cm CBL-F9M9-20: DB9 female to DB9 male serial cable, 20 cm CBL-RJ45SF9-150: RJ45 to DB9 female serial shielded cable, 150 cm ADP-RJ458P-DB9F: DB9 female to RJ45 connector A-ADP-RJ458P-DB9F-ABC01: DB9 female to RJ45 connector Mini DB9F-to-TB: DB9 female to terminal block connector - 2 -

Hardware Introduction LED Indicators LED Color Description Off is off or a fault condition exists Ready Steady: is on, and the MGate is functioning normally Blinking: The MGate has been located by the MGate Manager s Location function Red Steady: is on, and the MGate is booting up Blinking slowly: Indicates an IP conflict, or the DHCP or BOOTP server is not responding properly Flashing quickly: microsd card failed Off No I/O data is exchanged EIP (Scanner) EIP (Adapter) MB Off Off Red Steady: I/O data is exchanged with all devices Blinking: I/O data is exchanged with at least one device (not all configured devices can communicate with gateway) No I/O data is exchanged Steady: I/O data is exchanged with all devices Blinking: I/O data is exchanged with at least one device (not all configured devices can communicate with gateway) No communication with Modbus device Modbus communication in progress Communication error When MGate 5105 acts as Master: 1. Slave device returned an error (exception) 2. Received frame error (parity error, checksum error) 3. Timeout (slave device no response) When MGate 5105 acts as Slave: 1. Received invalid function code 2. Master accessed invalid register address or coil addresses 3. Received frame error (parity error, checksum error) - 3 -

Dimensions Unit: mm (inch) Reset Button Restore the MGate to factory default settings by using a pointed object (such as a straightened paper clip) to hold the reset button down until the Ready LED stops blinking (approx. five seconds). Pull-high, Pull-low, and Terminator for RS-485 Remove the MGate 5105-MB-EIP s top cover and you will find DIP switches to adjust each serial port s pull-high resistor, pull-low resistor, and terminator. SW 1 2 3 Pull-high resistor Pull-low resistor Terminator ON 1 kω 1 kω 120 Ω OFF 150 kω* 150 kω* * *Default Hardware Installation Procedure 1. Connect the power adapter. Connect the 12-48 V power line or DIN-rail power supply to the MGate 5105-MB-EIP device s terminal block. 2. Use a Modbus serial cable to connect the MGate to a Modbus slave device. 3. Use an Ethernet cable to connect the MGate to the EtherNet/IP controller. 4. The MGate 5105-MB-EIP is designed to be attached to a DIN rail or mounted on a wall. For DIN-rail mounting, push down the spring and properly attach it to the DIN rail until it snaps into place. For wall mounting, install the wall-mount kit (optional) first and then screw the device onto the wall. - 4 -

The following figure illustrates the two mounting options: Software Installation Information Please download the user's manual and Device Search Utility (DSU) from Moxa s website: www.moxa.com Refer to the user s manual for additional details on using the DSU. The MGate 5105-MB-EIP also supports login via a web browser. Default IP address: 192.168.127.254 Default account: admin Default password: moxa Pin Assignments Modbus Serial Port (Male DB9) Pin RS-232 RS-422/ RS-485 (4W) RS-485 (2W) 1 D TxD-(A) 2 RXD TxD+(B) 3 TXD RxD+(B) Data+(B) 4 DTR RxD-(A) Data-(A) 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 Ethernet Port (RJ45) Pin Signal 1 Tx+ 2 Tx- 3 Rx+ 6 Rx- - 5 -

Input and Relay Output Pinouts V2+ V2- V1+ V1- Shielded Ground Input 2 Specifications Input 2 N.O. Common N.C. Input 1 Input 1 Requirements Input 12 to 48 V Consumption 455 ma max. Operating Temperature Standard models: 0 to 60 C (32 to 140 F) Wide temp. models: -40 to 75 C (-40 to 167 F) Ambient Relative Humidity 5 to 95% RH Dimensions 36 x 105 x 140 mm (1.42 x 4.13 x 5.51 in) Reliability Alert Tools Built-in buzzer and RTC MTBF 1,140,815 hrs. 1. DEMKO Certification number: 13 ATEX 1307610X IEC Certification Number: IECEx UL 13.0051X; 2. Ambient Temperature Range: 0 C to 60 C (for models without the suffix T) -40 C to 75 C (for models with suffix T only) 3. Certification String: Ex na nc IIC T3 Gc 4. Standards Covered: EN 60079-0:2013+A11/IEC 60079-0 6th Ed. AND EN 60079-15:2010/IEC 60079-15 4th Ed. 5. The conditions of safe usage: a. The Ethernet Communications Devices are intended for mounting in a tool-accessible IP54 enclosure and used in an area of not more than pollution degree 2 as defined by IEC/EN 60664-1. b. Conductors suitable for use in an ambient temperature greater than 86 C must be used for the power supply terminal. c. A 4mm 2 conductor must be used when a connection to the external grounding screw is utilized. d. Provisions shall be made, either in the equipment or external to the equipment, to prevent the peak-rated voltage being exceeded by transient disturbances of more than 140% of the peak-rated voltage. - 6 -

Terminal block (plug matched with socket): rated at 300 V, 15 A, 105 C, 12-28 AWG (0.0804 mm2 to 3.31 mm2) wire size, torque value 4.5 lb-in (0.509 N-m). The input terminal cable size: 14 AWG (2.1 mm²). ATTENTION For installations in hazardous locations (Class 1, Division 2): These devices are to be installed in an enclosure with a toolremovable cover or door, suitable for the environment. NOTE This equipment is suitable for use in Class 1, Division 2, Groups A, B, C, D or nonhazardous locations only. WARNING EXPLOSION HAZARD Do not disconnect the equipment unless the power has been switched off, or the area is known to be nonhazardous. WARNING EXPLOSION HAZARD The substitution of any components may impair suitability for Class 1, Division 2. WARNING EXPOSURE TO SOME CHEMICALS MAY DEGRADE THE SEALING PROPERTIES OF MATERIALS USED IN THE FOLLOWING DEVICE: Sealed Relay Device U21. Moxa Inc. Fl. 4, No. 135, Lane 235, Baoqiao Rd. Xindian Dist., New Taipei City, 23145 Taiwan, R.O.C. - 7 -