Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Similar documents
1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

g GE Power Quality Digital Energy GT Series On-Line, Double Conversion Uninterruptible Power Supply 1000, 1500, 2200, 3000 VA UL-version

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

TME Modular Series UPS System kva/kw - 208/220 VAC

GAMATRONIC, A SolarEdge Division.

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SMARTONLINE E3 UPS SYSTEMS

SATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Uninterruptible Power Supplies

UPS Emergency Bed Power Unit

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

The quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Premium Online Series

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

MASTERELITE MULTITEC MRM/MRT MRM 10-20kVA single/single phase or three/single phase MRT 10-30kVA three/three phase

Product Specifications

Technical Specification Minipower Plus

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

LP 33 Series UPS. Digital Energy. GE Digital Energy

the Centric 300 An advanced modular UPS up to 1800kVA/kW

EP Series II UPS 230 V

Eaton 9EHD Industrial UPS

Sirius series. on-line

Eaton 9EHD Industrial UPS

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartOnline V 1kVA 700W On-Line Double-Conversion UPS, Tower, C14 inlet, DB9 Serial

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

DPA UPSCALE TM RI kw Technical Specifications

MAJOR VA Power Inverter

Intelligent On-Line UPS

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower, Extended Run, SNMPWEBCARD Option, USB, DB9 Serial

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

Sentinel Dual High Power

AIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

Socomec Netys PR RT U P S TOWER / RACK MOUNT

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

Conceptpower DPA TM S kva Technical Specifications

CPS kVA TRIFASE EN50171

SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

Smart-UPS APC Smart-UPS 750VA USB & Serial 120V

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

UPS EVO DSP TM ON LINE TM/TT. UPSman

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

Est ComPower Mini. Compact UPS kva

SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

Industrial Power Supplies

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

SR Plus series. on-line. SR20 Plus SR20T Plus. SR60 Plus LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS. Industrial PLCS

GE Critical Power. Single Phase UPS Overview. 1 Gabriele Andrighetti

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

Modular UPS S KVA

SLI 15 INVERTER SERIES, 1500 W

7011A Series Single-Phase

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

RT4F-110V/25A RECTIFIER

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

3 Uninterruptible Power Systems

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

Critical Power from GE. TLE Series UPS. TLE30-40 & TLE kva/kw Scalable three phase 400 Vac

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, V Hardwire output

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

Industrial Power Supplies

MODULAR UPS SYSTEM KVA

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Powerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial

Transcription:

GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com imagination at work

Model: Issued by: Approved by: LP11 Series 3 5 6 8 10 kva Product Document Department Riazzino - CH R & D Department Riazzino - CH Date of issue: 23.05.2017 File name: GE_UPS_TDS_LPE_11X_3K0_10K_1GB_V1705 Revision: 1705 Identification No.: Up-dating Revision Concern Date 0311 Initial release 14.11.2003 0511 Restyle 17.11.2005 0901 Branding, cooling, safety standards, backup table 01.04.2009 1010 Restyle 29.10.2010 1705 Restyle, branding, general revision 23.05.2017 COPYRIGHT 2017 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6

GENERAL DATA Topology VFI, double conversion Nominal output rating kva/kw 3/2.4 5/4 6/4.8 8/6.4 10/8 Overall efficiency at nominal load % 86 88 88 87 89 Heat dissipation at inverter nominal load, PF=0.8. and charged battery W 327 545 655 872 988 Cooling air (25 C - 30 C) m 3 /h 330 max. Audible noise level db(a) 40-50 (EN 27779) Operating temperature range -10 C - 40 C (15 C - 25 C recommended for battery) Storage temperature range -20 C - +45 C Relative humidity Max. 95% (non-condensing) Protection degree IP 20 (IEC 60529 and DIN 40050) Safety IEC/EN 62040-1/A1 EMC IEC/EN 62040-2 Surge capacity IEC 61000-4-5 (6kV 1.2/50 µsec 3kA 8/20µsec) Electrostatic discharge immunity 4kV contact / 8kV air discharge Transport On pallet / rollers for installation Colour Cubicle: RAL 9010 (white) Front panel: RAL 9006 (aluminum) Cable connections On terminals, bottom-rear Cooling Forced by regulated internal fans INPUT CONVERTER (rectifier + power factor correction) Nominal AC input voltage 220-240V L + N Input frequency range 40-70Hz Power factor >0.99 THDi <10% Nominal input current (no charging, Uin = nominal) A 12.1 19.8 23.7 31.6 39 Inrush current None DC output voltage 380 V BATTERY CHARGER Battery charging characteristic DC input voltage range DC output voltage IU (DIN 41773) constant current charging until floating voltage, then constant voltage charging + boost charge 350-450 V 162.5/177V (3kVA), 271/295.5V (5/6/8/10kVA) Output current limitation Adc 2.1 2.1 2.1 3.6 3.6 Recharge time 1.5-3 hours for 80% capacity BATTERY DATA Battery type Sealed and maintenance free (VRLA=Valve Regulated Lead Acid) Float voltage at 25 C 162.5 / 271 V Number of 12V batteries (in standard version) 12x7Ah (3kVA) 20x7Ah (5/6kVA) 20x12Ah (8/10kVA) Standard backup time at nominal load PF=0.8 min 8 9 7 10 7 Standard backup extensions See table on page 6 Modifications reserved Page 3/6

OUTPUT CONVERTER (inverter) Input voltage range 270-400 V Nominal output power at PF=0.8 kva 3 5 6 8 10 Nominal output power with resistive load kw 2.4 4 4.8 6.4 8 Nominal AC output voltage Output voltage waveform Output voltage tolerance: 220 / 230 / 240V (user selectable) Sine wave - static resistive load +/- 1% - dynamic mean deviation over half cycle (load step 0-100-0%) +/- 2% - with measured non-linear load 2.5:1 +/- 2% - recovery time to +/-1% 10ms Overload capability (battery operation) 110%: 20 min., 130%: 3.5 min., 150%: 2 min. Short circuit current capability (240ms) A 32 45 50 67 100 Output frequency Output frequency tolerance Frequency tracking range Max. phase shift difference input-output 7 Harmonic distortion with linear load 50/60Hz (selectable) +/- 0.1%, unless synchronised with the utility +/- 2, 4 or 6% of nominal, selectable 2% max Harmonic distortion with non-linear load (EN 50091) 10% max. with measured crest factor 2.5:1 Power factor range Any lagging or leading power factor is permitted within the specified rating to PF=0.5 Crest factor handling capability of a non-linear load 5:1 Up to 1000m no derating Output power derating altitude Till 2000m 12.5% per 1000m, max. 2000m Automatic shut down (or transfer to bypass if available) in case of: - low/high DC voltage Protection - overtemperature - overload / short circuit Output protected against connection to the mains Short-circuit clearance capability Inverter bridge 20% In within 10 ms with MCB class B PWM and IGBT technology BYPASS Primary components - Thyristor switch - Synchronisation circuit inverter/bypass mains Bypass voltage limits +/- 10% of nominal Frequency tracking range +/- 2, 4 or 6% of nominal, selectable Slew rate 1Hz/s or 5Hz/s, selectable Overload capability on bypass, 1 minute/10 minutes A 27/18 45/30 65/45 73/60 90/75 INTERFACING Potential free contacts ComConnect port (on Delta 9 pin connector) Input terminals for Four open-collector contacts signalling following alarms: - bypass active - mains failure - battery low - general alarm For serial communication - Emergency shutdown - Battery extension MCB alarm wiring Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6

CONTROLS, SIGNALS AND ALARMS Front Operation/Alarm : green/red LED LCD screen : 2 x 16 characters Push-buttons Buzzer (resettable) * = option Rear 3 option slots for : RS232 interface card (std installed) : Potentialfree contacts* : SNMP* : RPA* redundant parallel architecture On/off switch Manual bypass switch Input/Output terminals DC connector for external batteries (not for LP 3-11) Line circuit breaker Bypass circuit breaker The LCD screen shows UPS system data, status messages, alarm messages, settings. Front panel OPTIONAL FEATURES SNMP interface card An SNMP interface card can be placed in the rear panel of the UPS, and allows the data interface to be connected directly to an Ethernet network. When this option is installed the RS232 communication link (serial communication) is no longer available to the user. Relay card The relay plug-in card can be installed in the rear panel of the UPS. The card is provided with four potential free contacts representing: battery low, bypass active, utility failure and general alarm. Alarm boxes An interface box linked to the RS232 port, the VIC/RELAYBOX/01 translates the RS232 signals to five independent changeover contacts, with a maximum switching capacity of 230V/5A each. Wall mounted plastic alarm boxes are available for remote audible and visual alarm indication. Connectivity products A splitter box translates information from the RS232 to several computers. Interface kits (cables and/or software) are available for operating systems supporting JAVA and most commonly used network operating systems, including Novell, UNIX, VMS, Windows platforms, IBM OS/2, LINUX. Please contact your dealer for specific information. Battery extension packs Except for the 3-11 model, the LP 11 UPS can be equipped with additional batteries to increase the runtime of the unit. These additional batteries are housed in a separate battery pack. Additional batteries will increase the recharging time for the unit. All other operational information is the same. Battery packs can be connected in parallel to increase the runtime. DC connectors make installation of battery packs easy and simple. Modifications reserved Page 5/6

DIMENSIONS AND BATTERY UPS Model Backup time (min.) Total capacity (Ah) Nr. of extra battery cabinets Battery cabinet VSDA 1 LP3-11 8 7 n.a. n.a. LP5-11 LP6-11 LP8-11 LP10-11 9 * 7 * - 24 14 1 40 21 1 55 28 2 70 35 2 7 * 7 * - 19 14 * 1 32 21 1 Dimensions (hxwxd): 537x313x590mm Shipping dimensions (hxwxd): 800x460x750mm Dimensions Cabinet: "VSD1" Dimensions (hxwxd): 537x313x590mm (height with wheels) Shipping dimensions: 800x460x750mm 45 28 2 Battery: 240Vdc 58 35 2 7Ah or 14Ahr 10 * 12 * - Cabinet: "VSD2" 20 19 1 29 26 12 39 33 2 48 40 2 7 * 12 * - 15 19 1 23 26 1 31 33 2 40 40 2 (*): Standard backup time and capacity Weight with battery: 70kg or 120kg Shipping weight: 85kg or 135kg Dimensions (hxwxd): 680x313x720mm (height with wheels) Shipping dimensions: 915x460x810mm UPS cabinet UPS weight (*) 85kg 110kg 115kg 165kg 170kg Shipping weight (*) 100kg 125kg 130kg 185kg 190kg UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS INPUT: MAINS POWER WITH DISTURBANCES OUTPUT: PERFECT UPS POWER MANUAL BYPASS SWITCH BYPASS FILTER 1-PHASE MAINS INPUT RFI FILTER TO LOAD RFI FILTER INPUT CONVERTER/ BATTERY CHARGER OUTPUT CONVERTER AUTOMATIC BYPASS SWITCH OPTION SLOTS FOR: RPA CARD SNMP CARD OPTIONAL RELAY CARD BATTERY EXTENSION BATTERY SYSTEM ON/OFF FRONT PANEL STANDARD INSTALLED: RS232/ CONTACT INTERFACE MICROPROCESSOR CONTROL UPS Model Recommended external fusing of input wiring Fuses gl / gg or Automatic Breakers Cable sections input and output recommended by European standards / in ( ) SEV Alternatively, local standards to be respected CABLE SECTIONS Mains / Bypass input mm 2 AWG LP3-11 16A 4 12 LP5-11 25A 6 10 LP 6-11 25A 6 10 LP 8-11 50A 10 8 LP 10-11 50A 10 8 Modifications reserved Page 6/6