Operating instructions Optical distance sensor. OID25x / / 2015

Similar documents
Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor O1D / / 2008

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Photoelectric distance sensor OGD592 OGD593

Operating instructions IO-Link INLINE DISPLAY 1.44" E30430

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Standstill monitor A / / 2011

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Operating instructions. Speed monitor D / / 2014

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

Operating instructions Binary level sensor LMC / / 2014

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions RFID evaluation unit DTE / / 2016

Installation instructions Inclination sensor EC2019 EC / / 2013

Operating instructions Electronic pressure sensor PN7xxx

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating instructions Electronic temperature sensor TN7511

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions Control monitor for temperature sensors TR7439

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Operating instructions Electronic temperature sensor TN /00 04/2011

Operating instructions. Monitor FD / / 2013

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating instructions Flow sensors SAxx04 SAxx14

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Pressure sensor. PN70xx / / 2012

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Optical distance sensors. Dimensioned drawing

System manual AS-i safety monitor AC041S /00 05/2013

Installation instructions Ethernet switch EC / / 2011

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating instructions Electronic pressure sensor. PN2xxx / / 2015

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

Operating instructions Memory plug E /02 11/2011

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Quick reference guide 3D sensor O3D3xx

Operating instructions Electronic digital pressure sensor EPS25-XXXX-1001

Dimensions. Model Number. Indicators/operating means. Features. Electrical connection. Product information OQT150-R100-2EP-IO-V31-L

Optical laser distance sensors. Dimensioned drawing

Operating instructions Pressure sensor. PN70xx / / 2010

Operating instructions. Monitor FS-1 / FS-1N / / 2013

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31

Operating instructions Pressure sensor. PE30xx / / 2010

Instruction manual. Electronic pressure gauge (EPG) IM-TE91K033-EN5. Original manual

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

Technical Data. Dimensions

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Operating instructions Monitor FD-2 DR2005 DR / / 2007

PHOTOSWITCH Distance Measurement Sensor

Operating instructions RFID read/write head with IO-Link DTIxxx

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Operating instructions. ProcessLine analogue module AC / / 2012

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Brief instructions Illumination unit O3M /00 09/2014

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

Brief instructions Illumination unit O3M950 O3M /00 03/2016

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Installation Guide. O2Vxxx / / 2015

Continuous Wave Single Frequency Lasers. Concerto Series. 442nm 25, 50, 75 & 100mW

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Assembly and Operating Instructions. M2 module for BDC-i440 control units

D11 Expert Series 5V dc Models

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

Operation and Installation Manual

QUICK START GUIDE ODT-MAC40*-*-RD

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Kvaser Linx J1587 User's Guide

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

Line Laser Module LLM01. User Manual. JENOPTIK Group.

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1

Diffuse reflection light scanner with background suppression. Dimensioned drawing

HOME VENTILATION WITH HEAT RECOVERY. Ventilation units M-WRG-S/Z-S M-WRG-S/Z-24 M-WRG-S/Z-EIB M-WRG-S/Z-KNX (-F, -FC)

QUICK START GUIDE ODT-HH-MAH300 Handheld

Device manual Inclination sensor 2 axes JN /00 04/2015

CSM200 Expansion Tray

Operating instructions RFID evaluation unit DTE / / 2011

Operating Instructions

Transcription:

Operating instructions Optical distance sensor OID25x 80228366 / 00 03 / 2015

Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4 4 Installation...5 4.1 Installation conditions...5 5 Electrical connection...5 6 Operating and display elements...6 7 Settings / operation...6 7.1 Switch off the laser...6 8 IO-Link...7 8.1 General information...7 8.2 Device-specific information...7 8.3 Parameter setting tools...7 9 Maintenance, repair, disposal...7 2

1 Preliminary note 1.1 Symbols used Instructions > Reaction, result [ ] Designation of keys, buttons or indications Cross-reference Important note Non-compliance may result in malfunction or interference. Information Supplementary note 2 Safety instructions Read this document prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. That is why installation, electrical connection, set-up, operation and maintenance of the unit must be carried out by qualified personnel authorised by the machine operator. In case of malfunction of the unit please contact the manufacturer. If the unit is tampered with and/or modified, any liability and warranty is excluded. The unit complies with the standard EN 61000-6-4. The unit may cause radio interference in domestic areas. If interference occurs, the user must take appropriate remedial actions. 3

According to culus Caution - Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure. Visible laser light; CLASS 1 LASER PRODUCT. IEC 60825-1:2007 Complies with 21 CFR 1040.10 except for deviations according to Laser Notice No. 50, dated June 2007 Position of the product label Warning sign OID2xx LASER KLASSE 1 CLASS 1 LASER PRODUCT APPAREIL A LASER CLASSE 1 3 Functions and features The unit is used as an optical distance sensor. 3.1 Applications The optical distance sensor measures distances between 0.03 and 2 m. It has a background suppression of up to 20 m. The switching outputs are complementary. The distance between the sensor and the background must be limited to max. 20 m by the customer. Otherwise measured values can be ambiguous 4.1 Installation conditions. 4

4 Installation 4.1 Installation conditions Install the unit so that the object to be detected is within a measuring range of 0.03...2 m. Any object between the set switch point and a distance of 20 m from the sensor is suppressed. Reflecting surfaces in the direct beam path of the sensor also in the range > 20 m are to be avoided by the customer. Otherwise the measured values can be ambiguous. 5 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Ensure voltage supply to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: DC PNP 5 2 1 3 4 4: 2: 1 5 2 4 3 L+ IN L 5: IN = Laser on / off 4: OUT1 = normally open / IO-Link 2: OUT2 = normally closed Core colours of ifm sockets: 1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black), 5 = GR (grey) 5

6 Operating and display elements 1 1: LED yellow: Set value reached, output OUT1 = High (if OUT1 is configured as NO) 7 Settings / operation The unit is set via the IO-Link interface. ( 8 IO-Link) On delivery the unit can also be used without IO-Link. Preset switch point: 2 m After installation, electrical connection and programming, check whether the unit operates correctly. Lifetime of a laser diode: 50,000 hours 7.1 Switch off the laser For safety and maintenance purposes the laser of the unit can be temporarily switched off via the input on pin 5. Input signal at pin 5 Low / not connected High Laser On Off 6

8 IO-Link 8.1 General information This unit has an IO-Link communication interface which requires an IO-Link-capable module (IO-Link master) for operation. The IO-Link interface enables direct access to the sensor values and parameters and provides the possibility to set the parameters of the unit during operation. In addition communication is possible via a point-to-point connection with a USB adapter cable. You will find more detailed information about IO-Link at www.ifm.com/uk/io-link. 8.2 Device-specific information You will find the IODDs necessary for the configuration of the IO-Link device and detailed information about sensor values, diagnostic information and parameters in the overview table at www.ifm.com/uk/io-link. 8.3 Parameter setting tools You will find all necessary information about the required IO-Link hardware and software (e.g. ifm LINERECORDER SENSOR ZGS210) at www.ifm.com/uk/io-link. 9 Maintenance, repair, disposal Faulty sensors must only be repaired by the manufacturer. Keep the front lens of the sensor clean. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. Do not open the module housing. There are no user-serviceable components inside. Technical data and further information at www.ifm.com 7