Product manual plug, sockets and coupler 16 A.- Z0251

Similar documents
SolConeX extra-low voltage flange socket

SolConeX Wall-Mounted Socket, 16 A

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6412/5

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Safety Instructions Cerabar S PMP71, PMP75

Conveyor Belt Alignment Switches from IDEM

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

GRP Flameproof Visual Signal Xenon or Steady LED

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Metal Position Switch

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

INSTALLATION TECHNOLOGY MADE EASY

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Operating instructions. Speed monitor D / / 2014

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PI-EX-ME-2NAM/COC-120VAC

Inductive sensor BI1.5-EG08-Y1-H1341

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-24VDC

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341

Instruction Manual. T3110 T3110L T3110Ex

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Inductive sensor BI5-EM18-Y1X-H1141

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Terminal Boxes Series 8118

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Position Switches Series 8070

Inductive sensor with analog output BI15-M30-LI-EXI

Operating Manual. icam100

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Electrical Actuators

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

IECEx Certificate of Conformity

Electrical Actuators

PHOENIX CONTACT - 05/2007

Installation Instruction. HART Add-On Module

MANUAL LML-P, LML-S, LML-Ex

M E M O R A N D U M I.S.

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

MANUAL Surge Protectors

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

RТTH DUAL ROOM SWITCH

FLEX Ex Spring Clamp Terminal Base

Series Panel Mounted Control Devices

Power supply unit NG3-16ib

Page 1 of 5. Increased Safety, Encapsulation and Dust

Throughwiring. single-ended. twin-ended

Technical data sheet. Technical data

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

5 Fieldbus Technology

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Safety switches with manual mechanical delay and separate actuator

Operating Instructions

Operating Instructions

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Technical data sheets

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

The Solid-State Decoupler (SSD)

Intrinsically safe batch controller Batching Master 110i

MC 11 EB-2 Power supply cabinet with external bus, AC version

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Emergency power supply NV2.1-12iaE

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Operating instructions

NXCEX-6000 November 2, Series NXC20EX, and NXC40EX Servos for Class 1 Division 2. Hazardous Locations

* * Agilent Power Distribution Unit (PDU) Installation Guide

Transcription:

Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl

Purpose of these instructions Working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. Assembly and maintenance staff working on installations therefore have a particular responsibility. They require precise knowledge of the applicable standards and regulations. These instructions give a brief summary of the most important safety measures. It supplements the corresponding regulations which the staff must study. SAFETY INSTRUCTIONS - Use the explosion-proof plug and socket only for its intended purpose - Incorrect or impermissible use or non-compliance with these instructions invalidates our warranty provision. - No changes to the device impairing its explosion protection are permitted. - Use the indicating unit only if they are clean and undamaged. - Any damage can invalidate the Ex-protection. - Observe the following during installation and operation: * National safety regulations * National accident prevention regulations; * National installation regulations(e.g. IEC 60079-14); * Generally recognized technical regulations; * Safety guidelines in these operating instructions; * Characteristic values given on the explosion-proof plug and sockets. Conformity to standards The explosion-proof indicating unit is designed and manufactured according to standard of ISO 9001. The indicating unit is conformity to the directive 94/9/EC, ATEX and the following standards: IEC60079-0 : 2011 IEC60079-1 : 2014 IEC60079-7 : 2006 IEC60079-31 : 2013 EN60079-0 : 2012 EN60079-1 : 2014 EN60079-7 : 2015 EN60079-13 : 2014 Model and implication Z 0251 Voltage Number of poles 024 = 20 ~ 24 V AC/DC 050 = 40 ~ 50 V AC/DC 130 = 115 ~ 130 VAC / 50Hz 250 = 200 ~ 250 VAC / 50Hz 2 = 2P 3 = 1P + N + PE 4 = 3P + PE 5 = 3P + N + PE Classification code 1 = Wall socket 2 = Flange socket 3 = Coupler 4 = Plug Code of rated current: 16A Code of product type: Series of plug and socket Year number of design and development of product Type code of manufacturer -1- Z0251-18-07-18

Technical data Socket, Plug and Coupler II 2GD Ex db eb IIC T6 Gb Ex td A21 T80 Ta<45 C II 2GD Ex db eb IIC T5 Gb Ex td A21 T95 Ta<55 C Test certificate Wall type socket, Plug and Coupler - Presafe16ATEX 9155X - Protection degree IP66/IP65 Test certificate Flance socket - Presafe16ATEX 8120U Ambient temperature -40 C < Ta <55 C Material of enclosure: Polyamide and Glass fibre reinforced polyester Rated current16a Rated voltage: 2-pole 50VDC - 50VAC 50/60Hz 3-pole-415V 50/60Hz 4-pole-690V 50/60Hz 5-pole-415V 50/60Hz Rated switch capacity: AC3 2-pole 250V/16A DC1 2-pole 50V/16A AC3 3-pole 250V/16A AC3 4-pole 690V/16A AC3 5-pole 415V/16A Cable entry: Wall type socket 1 pcs cable gland M25 + 1 plug M25 Plug/Coupler type socket: - 3 pole 6.5-10.5mm/10-15.5mm/15-18.5mm - 4-5 pole 6.5-10.5mm /10-15.5mm/15-20mm Suggested moment of screw down M25 Stopping plug M25 Cable gland M4 Cover bolt Terminal bolt Size 4 Self tapping screw Size 5 Self tapping screw Airproof nut 2.0 Nm 3.0 Nm Comparison table of poles, clock position, colour and service voltage see table 1. Contact arrangement see figure 1. Operation / installation - Transport and storage in original packaging only. National safety and installations regulations and the generally accepted rules of engineering practice must be observed when mounting and using this equipment. - Explosion-proof pug and sockets are suitable for use in hazardous areas, zone 1,2, 21 and 22. - The eplug and sockets should be used under the following atmospheric conditions: * The pressure is 80kPa(0.8bar)~110kPa(1.1bar) * The volume ratio of standard oxygen content is 21% air; * The Ambient air relative humidity is less than: 95%; * There is no obvious shake and impact vibration place; - All screws on the connection terminals, including unused ones, must be fully tightened. - To prevent accumulation of electrostatic charge, only damp cloth can be used during the cleaning! -2- Z0251-18-07-18

Poles Clock position Colour Service voltage Table1 L Dimentions plug ØD / Purple < 24V AC/DC 2 pole 12h White 40-50VAC 3 pole 10h 4h 6h White Yellow Blue 20-50VDC 110-130V 200-250V 2P/2P+ / 1P+N+ N+ ØD 73 77 84 L 163 187 187 9h Blue 200-250V 4 pole 6h 7h Red Black 380-415V 480-500V L2 Dimensions coupler type socket L1 5h Black 600-690V 5 pole W1 W2 6h Red 200-250V 380-415V Dimentions wall type socket H 2P/2P+ / 1N+P+ N+ L1 L2 L3 247 69 72 279 279 90 90 93 93 Installation dimensions of panel type socket 2P/2P+ / 1P+N+ W1 W2 L1 L2 L3 H 103 86 223 156 142 122 123 106 241 176 163 147 3-pole 4-pole and 5-pole N+ 123 106 241 176 163 147 Electrical diagram 2-Pole 3-Pole 4-Pole 5-Pole L/+ N/ - L1 N L1 L2 L3 L1 L2 L3 N 2P 2P+ 1N+P+ 3P + N + -3- Z0251-18-07-18

Opening the device / electrical connection of plug and coupler The electrical connection of the full plastic plug and socket may only be carried out by skilled electrician. * 1 remove screws (2) * 2 take down the plug (1) form the cover * 3 remove the clamp (3) and turn loose the rotery seal (4) * 4 Penetrate the cable and connect the wiring * 5 put the plug back in the cover and tighten the screws (1-2) * 6 clamp the rotety seal and fix the clamp (3-4) 3 2 1 4 Opening the device / electrical connection of wall socket The electrical connection of the full plastic plug and socket may only be carried out by skilled electrician. * 1 remove the cover * 2 Penetrate the cable to the gland and connect the wiring Check before the devices go into service: - All screws must be fully tightened - The devices shall not be damaged - Make sure the gland is properly tightened Taking into operation before taking into operation test if its function is in accordance with the requirement and installation rules. - Check the plug for any damages before putting it in the socket. - The voltage of socket shall be checked if it is in accordance with the voltage of the plug of electric appliance equipment - Check if the earthing is well connected before use. T -4- Z0251-18-07-18

Use of plug and socket type Z0251 and Z0252 1 4 The protective cover of the socket may be secured with a padlock. Plug must be fully inserted. 2 The protective cover ensures IP66 protection. Turn the cover anti clock wise, so the cover can be opened and the plug can be inserted. 5 2 1 3 The plug must be in line with the socket. 1. First the plug must be turned clockwise until a clicking sound is heard. This means the power is connected and the plug cannot be removed from the socket. 2. After this, turn the ring on the top of the plug clockwise to obtain IP66 protection and lock the plug together with the socket. -5- Z0251-18-07-18

Spare parts / Accessparts - Use only original spare parts as well as original accessories made by INDEX ELEKTRO BV. Repairs / Maintenance - Observe the relevant national regulations for your country! - Only parts from our company that can be used to replace or maintain, and the operation should be carried out by professional electrician! - The following points must be checked during maintenance: * Compliance with permitted temperatures; * Check if the product has been fixed reliably. * Check the wiring. Recycling / Disposal - The respective valid national regulations for waste disposal shall be observed when disposing of apparatus! - We are pleased to answer any questions. In this case you can contact INDEX ELEKTRO BV. -6- Z0251-18.07.18