DATRAN XL4 PLUS RTU Quick Start Guide

Similar documents
QTech 3G Cellular Modem CM910. Quick Start Guide

DATRAN XL4 PLUS RTU USER GUIDE. Version 02

DATRAN XL4 RTU Modbus Interface

Q22 DATRAN II excel Owners Manual

QTech SMS Lite Quick Start Guide

QTech Workbench User Manual

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Upgrading Q04 firmware to Q04 Plus on XL4 RTU

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

QTech Workbench USER GUIDE QTech Workbench

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

4.6 PT8AIIS ISOLATED ANALOG CURRENT INPUTS Description

DATRAN Hardware & Telemetry Training Course

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

TS001 Sonnen eco 8 Trouble Shooting Guide. Issue Reason Solution

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

MOTION COORDINATOR MC405 Quick Connection Guide

icex-cmtm General specs and Installation guide

HRM-0800 Instruction Manual

Installation Manual for D244X Series 24-volt Power Supplies

8600 RTU Serial Port Status Cable Assembly for PCM v1.8 25x86 LP Drawings

XL4Plus as a Modbus Master

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

Datscan EP3 Data Manager Installation / Configuration Guide

ATK3 I/O Module (Modbus Slave)

Copyright Extract from Conditions of Sale Safety Warning

PM4 INSTRUCTIONS. PM4 WIRING (See Tables 1 & 2 and Wiring Examples)

DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for TPSD/A36D Chargers with S2A-205T Option 21P or 57T or 57U. Setup Instructions

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

NX21 USER MANUAL. Telemetry Unit. Version 1.5

CPU ONE PLC PLC USER S MANUAL

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

RTU560 Connections and Settings DIN Rail RTU 560CIG10

P3-SCM. General Specifications

A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE

A12B DNP 3.0 SERIAL & ETHERNET (TCP/IP) SCADA INTERFACE

ezeio Controller and the 2400-A16 input expansion.

USER GUIDE. to the CP130. Thermal Printer

FEATURES DESCRIPTION FEATURES

Basic Express, BasicX, BX-01, BX-24 and BX-35 are trademarks of NetMedia, Inc.

P USB 2.0 (Type B) Port - Programming - Online monitoring

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

Revolutionizing control wiring

Version 1.0c May 6, 2010 ATK3

G303 RIO (REMOTE I/O) AND LOW END RTU

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

PLA User. WARNING: read connection information(p5) before connecting PL controllers to the PLA

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

General Specifications. P2-SCM Serial Communications

USER MANUAL FOR GS100/GS1003G

Installing Sentor. Hardware Installation

Troubleshooting the NAE/NIE

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

Canlan INSTALLATION MANUAL

RTU560 Remote Terminal Unit Connections and Settings

CORTEX Microcontroller and Joystick User Guide

RS485 MODBUS Module 8AO

RM6000 GPRS Modem / Router

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

TinyTrak4 v7 Hardware Manual

FULMATIC 7 SILVER SERIES PLC PLC USER S MANUAL

Keep all manuals as a product component during the life span of the product. Pass all manuals to future users / owners of the product.

ADDENDUM FOR 20, 27, & 28 OPTIONS

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

With a digital input we can read two states, a high or low. A switch can be open or closed.

Butterfly Laser Diode Mount

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

VersaMax Micro and Nano Technical Product Presentation

Table of Contents. Chapter 1: Getting Started. Chapter 2: Specifications

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

INSTALLATION GUIDE Maxiflex P3e CPU M1262F

Installation & Operation Guide

PS-4100 POWER SUPPLY MANUAL

Owner s Hardware Service Manual Frank Control Computer System

AX1500. Dual Channel Digital Motor Controller. Quick Start Manual. v1.9b, June 1, 2007

Helios PD Large Display Meter Quick Start Guide

GE Fanuc IC694ALG221. Rx3i PacSystem

Ponto Series CPUs. Product Description. Ordering Information

DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS FOR 205T BASED SYSTEMS

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

IC693PWR331 High Capacity Power Supply, 24 VDC Input

Z-2400-RB/TCP TURBO Wireless Data Links Using ZIGBEE For MicroScan Protocols.

SBR The Chameleon Converter II

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

iopro Mirrored IO System

TM241CE40R controller M IO relay Ethernet

Product Data Sheet. BMS/Graphics Interface. Features

Sensacell Troubleshooting Guide

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

MC CO MODBUS ADDRESSABLE SENSOR

User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

EGW1-IA3-MB User s Manual

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

IMIO100 IMIO105. DDC controllers. Summary

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

Transcription:

DOC-QSG-XL4-PLUS-RTU DATRAN XL4 PLUS RTU Quick Start Guide

Configuring the XL4 Plus RTU The XL4 Plus RTU is configured using software called QTech Workbench. Connection to your PC is via a USB cable (Type A to Type B). The configuration software is available for download from the QTech Website. For technical support contact QTech at techsupport@qtech.co.nz. RTU Address Every RTU has a unique site address so that a DATRAN base station can communicate with it. When an RTU is installed at site, its address must be configured. Unlike older model DATRAN RTUs, the address for the XL4 Plus is configured using QTech Workbench. The module address can be any number between 1 and 239, when configuring the device to connect to a DATRAN Base Station (serial or ethernet) in Workbench. Factory Defaults From time to time it may be necessary for you to reset the XL4 Plus back to factory defaults. There are two ways of doing this: The factory default settings can be loaded back into the RTU using the Factory Default button in QTech Workbench screen. There is a jumper on the RTU main processor board labelled INIT. It is normally open, but if the RTU is started up while the jumper is installed it will cause the RTU to restore the factory default settings. Use this method only if instructed to do so by QTech Staff. Status LEDs ON: OK : IP : MU : RX : KY : TX : ER : Important: The i/o connectors for the RTU must be disconnected prior to setting factory defaults. It is very important to remove the INIT jumper before reconnecting the connectors. This LED is always on when the XL4 RTU is powered. This LED fades slowly on and off to show the CPU has not locked up. If it is on solidly or stays off, then the RTU needs attention. Note. The XL4 RTU and XL4 Plus RTU look similar. The XL4 RTU uses a 1 second flash to indicate OK status, The XL4 Plus RTU uses a slow fade of the same LED to give the operator a quick visual indication that the RTU is running OK on XL4 Plus firmware. This LED indicates that the RTU is currently sending comms out its IPB port to communicate with I/O expansion modules. The MUTE signal from the Radio. This indicates the radio is currently receiving an RF signal. The RTU modem is receiving and decoding data from the radio. This LED will usually appear to flicker This indicates the RTU is attempting to key on the radio transmitter. The RTU is transmitting data through the radio. This LED will usually appear to flicker This is the Error Indication LED. The LED will flash a certain number of times to indicate any error messages the RTU has been configured to display. Error Flash Message Error Flash Message Error Flash Message 1 Main Battery Low 5 Dig Output Fail Continuous Flash Licence Issue* 2 Clock Battery Low 6 Analog Input Fail 10 Modbus Client (TCP) Error 3 Datran Comms Fail 7 DLP Error 11 Qcomms Master (serial) Error 4 IPB comms Fail 8 Modbus Master (Serial) Error * The RTU may require a licence key to operate contact QTech for assistance. 12 Qcomms Server (TCP) Error www.qtech.co.nz Ph: +64 3 366 3713 Page 2 of 6

Supply Voltage: 12 Volts or 24 Volts The RTU can be supplied from 12-30V DC. The RTU is factory configured for a nominal 12V DC supply, unless otherwise requested. When configured for 12V, the RTU will automatically shut itself down when the supply voltage drops to 10.5V. If the RTU is to be supplied from 24V it is necessary to change J27, located on the Q22 (bottom board) in the RTU. This changes the low voltage shutdown voltage to 21V. The power option is marked on the case label. Low Voltage Drop Out Threshold J27 12V supply Installed 24V supply Open Power Supply Connections RS485 Port The power connector has three connections: -V = Power Supply Negative +V = Power Supply Positive, 12 30 V DC O/P = Control Signal Output. This allows the RTU to turn on devices when it is powered up. This was previously labelled C on older excel RTUs The O/P terminal is an OUTPUT. Do not connect it to the supply. The XL4 Plus and associated peripherals should all share a common earth point. The XL4 Plus RS485 port is an RJ12 connector, identified by having 6 contacts, as shown. The previous Q03 RS485 connectors were an RJ10 connector with 4 contacts. Ensure that the 6 contact RJ12 is plugged into the XL4 RTU. Do not attempt to insert the 4 contact RJ10 into the RTU, this must be inserted in the expansion module (Q23/Q26 etc). Digital Inputs The connector used for the XL4 Plus RS485 port is not compatible with the Q03. Care must be taken as forcing a Q03 RJ10 plug into a Q04 can damage the socket. The XL4 Plus RTU digital inputs are designed to interface easily with physical switching devices. They have an internal pull-up resistor that will pull the input terminal to the power supply + when the input is open circuit (the OFF state). To turn a digital input ON, connect it (via a set of contacts if necessary) to the common G terminal on the Digital Input terminal block. All G terminals on the RTU are tied internally to the G terminal on the power supply connector. The LED associated with each digital input will light up when the input is Active/On/Closed. The pull up / pull down convention is different from some PLCs. If required, the active state of I/O can be inverted in the RTU DLP control program or PLC. www.qtech.co.nz Ph: +64 3 366 3713 Page 3 of 6

Digital Outputs The XL4 Plus RTU Digital Outputs are designed to be easily interfaced with relays and contactors. The RTU has 8 Digital Outputs in total. Digital Outputs 1 to 4 are located on the front panel adjacent to the Digital Inputs and have LED indicators to show if the output is active or not. Digital Outputs 5 to 8 are located on the underside of the RTU next to the power connector. The Digital Outputs work as Current Sinks. This means that when they are turned on, they will be connected to power supply ground, allowing current to flow into the output terminal to ground. In the OFF state, they have a high impedance to ground and will float up to + Supply. To use a digital output with a relay, wire as shown in the diagram opposite: Analog Inputs The XL4 Plus RTU has 6 analog channels. All analog channels are independently capable of operation as either 0-20mA, 4-20mA, 0-5V or 0-10V. In addition to this, channels 5 and 6 are independently able to be configured as either inputs or outputs. The RTU is factory shipped with all analog channels configured as 4-20 ma inputs. For details on how to reconfigure them, refer to the Owners Manual. For all analog inputs, the current return path is via the ground of the RTU power supply. It is important to understand the implications of this when wiring certain analog devices to the RTU, as detailed below. The LEDs adjacent to each Analog Input show the status of the signal the RTU is receiving. If the LED is off, it means the input signal is zero, or under-range. When the LED is on, it indicates the signal is within the measuring range that the input has been configured for. If the LED is flashing, it shows the signal is overrange. Loop Powered Devices Loop-Powered, or 2-Wire devices derive their power supply from the current flowing in the loop itself. It is important to make sure that any device is rated to operate at the voltage that will be available to it taking into account that the RTU Analog Input will drop 5V across it at 20mA loop current. For example: If the system is being powered from 13.7V DC, the analog transducer will only have a maximum of 8.7V available to it for its power supply. To wire a 2-Wire device, refer to the diagram opposite: Separately Supplied Devices Separately Supplied, or 4-Wire devices are analog transmitters that have a separate power supply from the analog signal loop. If suitable, these devices can be powered from the RTU power supply and wired as shown. If the RTU power supply is not suitable, the analog sensor can be powered from a separate power supply as long as the grounds of both the RTU and the other power supply are connected together. www.qtech.co.nz Ph: +64 3 366 3713 Page 4 of 6

User Notes and Installation Details www.qtech.co.nz Ph: +64 3 366 3713 Page 5 of 6

QTech Data Systems Ltd 12 Midas Place, Middleton, Christchurch 8024 PO Box 9087, Tower Junction, Christchurch 8149 Ph: +64 3 366 3713 Fx: +64 3 365 2815 admin@qtech.co.nz techsupport@qtech.co.nz www.qtech.co.nz www.qtech.co.nz Ph: +64 3 366 3713 Page 6 of 6