SECURITY MODULE CG3 User Manual Security system can be managed with Paradox K636, K10 LED, K32 LED and Protegus SK130 LED
Control by the keypad Paradox 1. Full arming the security system (when the security system is not partitioned). Note: If zones are damaged, security system will not arm! [4321] Enter a User code with a keypad. After entering the time countdown for leaving the premises (Exit Delay) will start. The key [ARM] will start flashing. During this time zone Delay must be disturbed. It means during this time you must open the door, leave the premises and close the door. When the security system arms, the key [ARM] will turn shining. If Bell squawk function is enabled, siren will make a short signal. 2. Arming in the mode STAY (when staying inside). ( 1st method). Note: If zones are damaged, security system will not arm! Note. At least one input must be defined to operate as zone either Instant STAY or Interior STAY. [STAY] + [4321] + [1] + [ENTER] Press the key [STAY] and then enter the User code. Enter the serial number of Partition you need to arm. If security system is not partitioned, enter the number [1]. Press the key [ENTER]. When security system arms, the key [ARM] will turn shining and [STAY] flashing. When the security system is being on state armed, disturbances in zones Interior STAY and Instant STAY will be allowed. But the zone Delay will turn operating as an instant operating zone Instant. It means when door opens Entry delay time countdown will not turn but security system will turn alarming instantly. 3. Arming in the mode STAY (when staying inside). ( 2nd method). Note: If zones are damaged, security system will not arm! Note. At least one input must be defined to operate as zone either Instant STAY or Interior STAY. [4321] Enter the User code and do not disturb the zone Delay. It means don t open the door. If during the Exit delay time the zone Delay will not be disturbed (exit door won t be opened), protection mode STAY will turn on. The key [ARM] will start shining and [STAY] flashing. When the security system being on state armed, disturbances in zones Interior STAY and Instant STAY will be allowed and if the zone Delay be disturbed, the Entry delay time countdown will turn. It means when door opens, you must disarm the security system during the Entry delay time countdown. 4. Disarming the security system. [1234] Enter the User code. You must enter your code during Entry delay time. When the security system disarms (turns off), the key [OFF] will start shining. If Bell squawk function is enabled, siren will make two short signals. 5. BYPASSING a zone. [BYP] + [4321] + [12] + [ENTER] Before the arming the security system, press the key [BYP] and then enter the User code. The key [BYP] will start flashing. Enter a two-digit serial number of the zone which control you want to disable. Press the key [ENTER]. The key [BYP] will start shining. If you need to disable one more zone, press the key [BYP], enter User code, enter serial number of second zone you want to disable and then press the key [ENTER]. Now security system is ready to be armed while a zone is being disturbed. Follow the instructions above to arm the security system in mode you need. Zone control can be disabled for one period of arming the security system. To cancel a zone bypassing repeat the same key entering as the zone has been bypassed ([BYP] + [4321] + [12] + [ENTER]).
6. Changing the administrator (Master) code. Note: Master code can be edited but cannot be deleted. + [1234] + [01] + [XXXX] +[XXXX] + [1] + [ENTER] + [CLEAR] + [CLEAR] Press the key and then enter the Master code (default is 1234). The key will start flashing and the key [1] - shining. Enter the two-digit serial number of Master code [01] and then enter the new four-digit Master code. Enter the new four-digit Master code one more time. One after another enter the numbers of Partitions which can be managed with this code (e.g. [1]+[2]+ +[8]). If security system is not partitioned, just enter the number [1]. Press the key [ENTER] and then two times enter the key [CLEAR]. 7. Entering of new User code. + [1234] + [02] + [XXXX] +[XXXX] + [1] + [ENTER] + [CLEAR] + [CLEAR] Press the key and then enter the Master code. If the code is correct, the key will start flashing and key [1] shining. Other flashing keypad keys show serial numbers of users, which User codes have already been entered. Enter the two-digit serial number of User code and then enter new four-digit User code. Enter the new User code one more time. One after another enter the numbers of Partitions which can be managed with this code (e.g. [1]+[2]+ +[8]). If security system is not partitioned, just enter the number [1]. Press the key [ENTER] and then two times enter the key [CLEAR]. Other User codes can be entered in the same way. 8. Deleting of User code. + [1234] + [02] + [SLEEP] + [CLEAR] + [CLEAR] Press the key and then enter the Master code. If the code is correct, the key will start flashing. Other flashing keypad keys show serial numbers of users, which User codes have been entered. Enter the two-digit serial number of user whose code you want to delete. Press the key [SLEEP]. A sound signal will be heard and key lighting, indicating the serial number of the code being deleted, will turn off. The code has been deleted. Two times press the key [CLEAR]. 9. When the system is partitioned, the way to see arming status of Partitions. Simultaneously press and hold for 2-3 seconds the keys [1] and [2]. If number keys flash, it means that these Partitions are armed in STAY. If number keys shine, it means that these Partitions are armed in Full ARM mode. If number keys stay off, it means all Partitions are disarmed. To cancel the programming, two times press the key [CLEAR]. 10. Arming of a particular Partition. Note: If zones of the particular Partition are damaged, security system will not arm! [ARM] + [4321] + [2] + [ENTER] Press the key [ARM] and then enter the User code. Enter the serial number of Partition you need to arm and press the key [Enter]. The Exit delay time countdown for leaving the premises will turn on. Delay zone of the partition must be disturbed. It means during this time you must open the door, leave the premises and close the door. The key [ARM] will start flashing and when the security system arms shining.
11. Arming in STAY of the Partition ( 1st method) (when several Partitions can be managed with a User code). Note: If zones of the particular Partition are damaged, security system will not arm! Note. At least one input must be defined to operate as zone either Instant STAY or Interior STAY. [STAY] + [4321] + [2] + [ENTER] Press the key [STAY] and then enter the User code. Enter the serial number of Partition you need to arm (e.g. [2]) and press the key [ENTER]. If during the for exit zone Delay will not be disturbed, area protection mode STAY will turn on. When the Partition arms, the key [ARM] will turn shining and [STAY] flashing. When the Partition is being on state armed, disturbances in zones Interior STAY and Instant STAY will be allowed. But the zone Delay will turn operating as an instant operating zone Instant. It means when door opens Entry delay time countdown will not turn but security system will turn alarming instantly. To see which one Partition is armed in STAY, simultaneously press and hold for 2-3 seconds the keys [1] and [2]. 12. Arming in STAY of the Partition ( 2nd method) (when several Partitions can be managed with a User code). Note: If zones of the particular Partition are damaged, security system will not arm! Note. At least one input must be defined to operate as zone either Instant STAY or Interior STAY. [ARM] + [4321] + [2] + [ENTER] Press the key [ARM] and then enter the User code. Enter the serial number of Partition you need to arm (e.g. [2]) and press the key [ENTER]. Do not disturb the zone Delay. It means don t open the door. If during the time for exit zone Delay will not be disturbed, protection mode STAY will turn on. The key [ARM] will start shining and [STAY] flashing. When the Partition is being on state armed, disturbances in zones Interior STAY and Instant STAY will be allowed. If the zone Delay be disturbed, the Entry delay time countdown will turn. It means when door opens, you must disarm the Partition during the Entry delay time countdown. To see which one Partition is armed in STAY, simultaneously press and hold for 2-3 seconds the keys [1] and [2]. 13. Disarming of the Partition. [OFF] + [4321] + [2] + [ENTER] Open the door and during the Entry delay time press the key [OFF], enter a User code, the serial number of Partition you need to disarm (e.g. [2]) and press the key [ENTER]. 14. Reviewing security system alarm memory. After the security system has been disturbed, the key [MEM] will start shining and keys describing serial numbers of disturbed zones will start flashing rapidly. The same indication stays after the disarming the system. [MEM] + [CLEAR] + [CLEAR] To clear memory, press the key [MEM] and then two times press the key [CLEAR]. 15. To cancel the programming mode, erase or edit incorrectly entered command, always use pressing the key [CLEAR].
Control by the keypad Protegus 1. ARM. Note. If there is zone alarm, security system cannot be armed. [1234] Enter a User code with a keypad. After entering a User code the time countdown Exit Delay for leaving the premises and closing the door will start. The keypad indicator [ARM] will start flashing until ARM mode turns on, after that indicator [ARM] will be constantly on until DISARM. If there is a Bell Squawk function enabled, the short bell signal will be formed then security system arms. 2. ARM in STAY mode. Note. If there is zone alarm, other than Interior STAY or Instant STAY zone, security system cannot be armed in STAY mode. Note. At least one zone has to be set to Interior STAY or Instant STAY mode. [ ]+[1234] Touch the key [ ] and enter the user code. After entering a User code the time countdown Exit Delay for leaving the premises and closing the door will start. When security system will arm the keypad indicators [ARM] and [STAY] will light up. In STAY mode, violations of Interior STAY and Instant STAY zones will be allowed. If there is a violation of Delay zone a time (Entry Delay) count will start for entering premises and User code. 3. ARM in SLEEP mode. Note. If there is zone alarm, other than Interior STAY or Instant STAY zone, security system cannot be armed in SLEEP mode. Note. At least one zone has to be set to Interior STAY or Instant STAY mode. [ ]+[1234] Touch the key [ ]. Enter the user code and do not violate Delay zone during Exit Delay time, for example, do not open the door. The security system will arm in SLEEP mode. When security system will arm the keypad indicator [ARM]
will light up and [STAY] will start to blink. In SLEEP mode, violations of Interior STAY and Instant STAY zones will be allowed. In this mode Delay zone becomes Instant type zone, there is no time delay (Entry Delay) if zone is violated. The security system will be alarmed immediately and event messages will be sent. 4. DISARM. [1234] In any ARM or STAY mode you must enter your User code during set time Entry Delay to DISARM the security system. If security system is armed in STAY or SLEEP mode and you are inside of premises, in order to disarm it you must enter your User code. If there is a Bell Squawk function enabled, the two short bell signals will be formed then security system disarms Bypass function. It will be possible to ARM the security system, though the bypassed zone will be violated. Zone bypass can be done only for one arm/disarm period. [ ]+[1234]+[12]+[ ] Before arming the security system touch the key [ ] on the keypad and enter the User code. The indicator [BYP] will start flashing. Enter the 2-digit zone number and touch [ ]. The indicator [BYP] will light up. If there is a need to bypass another zone, repeat the previously described actions. Then finished, ARM the security system in usual way by entering user code. The security system will ARM, though there will be a violated zone. 5. Bypass turn off. If there is needed to turn off the bypass for selected zone, please repeat the same actions as noted in BYPASS function. 6. Master code. Master code can be edited, but cannot be deleted. [ ]+[1234]+[01]+[XXXX]+[XXXX]+[ ]+[ ]+[ ] Touch the key [ ] and enter the Master code (default - 1234). The zone indicators will be illuminated on a
keypad according to serial numbers of already entered user codes. Enter a 2-digit serial number of User code [01] and then enter the new 4-digit User code twice. Touch the key [ ] and then the key [ ] twice. 7. New User codes. [ ]+[1234]+[02]+[XXXX]+[XXXX] +[ ]+[ ]+[ ] Touch the key [ ] and enter the Master code (default - 1234). The zone indicators will be illuminated on a keypad according to serial numbers of already entered user codes. Enter a 2-digit serial number of User code, for example [02], and then enter the new 4-digit User code twice. Touch the key [ ] and then the key [ ] twice. 8. Delete of User code. [ ]+[1234]+[02]+ [ ] + [ ]+[ ] Touch the key [ ] and enter the Master code (default - 1234). The zone indicators will be illuminated on a keypad according to serial numbers of already entered user codes. Enter a 2-digit serial number of User code you want to delete, for example [02]. Touch the key [ ]. A sound signal will be heard and zone key lighting, indicating the serial number of the code being deleted, will turn off. Touch the key [ ] twice. 9. Security system alarm memory clear. [ ] 3 seconds, [ ] After the security system has been disturbed, the indicator [MEM] will be illuminated on the keypad and keys describing serial numbers of violated zones will start flashing rapidly. The indication of violated zones on the keypad will be the same even after disarm. In order to clear the memory, hold down the key [ ] for 3 seconds and then touch key [ ]] one more time. 10. Reset of 2-wire detectors. [ ] 3 seconds 2-wire detectors connected to the IN8/2Wire terminal can be reset by holding down the key [ ] for 3 seconds. 11. To exit programming mode, erase or edit incorrectly entered values, always use touching the key [ ]. 12. Emergency Keys. Panic hold down the [1] key for 3 seconds. Auxiliary hold down the [4] key for 3 seconds Fire hold down the [7] key for 3 seconds.
Remote module control with a mobile phone Some of module parameters can be changed with a mobile phone (all module CG3 parameters can be changed only with program CGconfig). An SMS message with structure presented below should be sent to change module parameters remotely: PSW[Password]space[Command code]space[command content] Attention!: Change the default password (123456) to new one known only by you. SMS text for changing the password: PSW123456 98 000000 98 command to change the password; 000000 new password (6 digits); space between values. Command and request examples: SMS text PSW000000 97 3 PSW000000 97 4 PSW000000 97 5 PSW000000 50 N PSW000000 5N 0 PSW000000 5N 1 PSW000000 10 xxx.xxx.xxx.xxx_yyyy# PSW000000 11 xxx.xxx.xxx.xxx_yyyy# PSW000000 96 yy/mm/dd#hh:mm# PSW000000 99 Description Module will send an SMS message about the status of inputs; Module will send an SMS message about the status of the security system, inputs and power supply; Module will send an SMS message about GSM network strength and module IMEI number; N th output status will be changed to opposite; N values: 1, 2, 3, 4, 5, 6 N th output status will be changed to [0]; N values: 1, 2, 3, 4, 5, 6 N th output status will be changed to [1]; N values: 1, 2, 3, 4, 5, 6 To set the first IP address and port number. xxx.xxx.xxx.xxx IP address yyyy Port number To set the second IP address and port number. xxx.xxx.xxx.xxx IP address yyyy Port number To set the date and time of the control panel. yy year, mm month, dd day, hh hour, mm minutes. Command: Restart the module SMS messages have to be started with a capital letter combination PSW and a six-digit password entered in the module. The symbol indicates a space in SMS message text. The module will send the SMS message a response to request to the phone, from which the request was received.