Endoscopes Inspection Report Sale: 1406 Date: 13 / 05 / 2014 (Condition Reports for other items at the end of the Scopes Report)

Similar documents
Condition Report. Sale /10/ :00:00 - Medical Equipment Auction - PART :00. Sale Date

Condition Report. Olympus CYF-4A Fiber Cystoscope SN

Condition Report /09/ :00 - Endoscopy and General Medical Equipment - PART :00

Condition Report /09/ :00 - Medical Equipment Auction :00

Professional Health Solutions

Sheath E-Line 8,5 Fr, With Obturator For 1 Urethrotome

a. Arthroscopes Stryker, Storz, Dyonics many in stock - Call b. Arthroscopy Instruments many in stock, please inquire

ACCESSORY GUIDE REV D

HLL Lifecare Ltd. Amendment No.1. Ref: (i) Tender Enquiry No.: HLL/PCD/PMSSY/AIIMS-II/27/18-19 dated

FLORIDA LIFE SYSTEMS, INC. PH

Your Eye Inside. VIDEO BORESCOPES Made in USA. The next generation of fully-portable, articulating videoscopes!

Professional Health Solutions

ipad SP2 Automatic External Defibrillator

Rigel SIM Range Accessory List. Innovating Together

Fiberoptic Bronchoscopy Redefined, Once Again

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

Vision of the Next Generation

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100

LIFEPAK 15 Test Calibration Procedure ( TCP)

ENT /2018-E TELE PACK X LED. New Dimensions in LED Stroboscopy

Amendment No. 02. Ref: (i) Tender No: HITES/PCD/AIIMS-BBSR/04/18-19 dated Section I Notice Inviting Tenders(NIT)

Original Manufacturer

BF-UC180F. Endoscopic Ultrasonography Setting a New Standard in Mediastinal Diagnostics.

User Manual DUO BEAM/RG

RAD system. C- arm. Price 337,500 SDG. Mobile C-arm: Model OPESCOPE Activo. 2 monitors. Easy to use. Quick c-arm positioning. Simple operation.

OMM200 and OMM200T. Metallurgical Microscope

Propaq LT Monitors. Propaq LT Base Model. Propaq LT with Wireless Option/ Legendary quality and durability Heart rate, 3-or 5-lead ECG, SpO 2

Endoscopes of highest standards for ENT-specialists

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

Catalogue POLYDIAGNOST Version: 2.7 With publication of this catalogue older versions loose their validation

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

Your Eye Inside VIDEO BORESCOPES. The next generation of fully-portable, articulating videoscopes!

Equine Dental Scope VET /2017-E

Resusci Anne Simulator

Ansur Index 2XL. Users Manual. Plug-In

Rigel Medical. Leaders in biomedical test solutions. Performance Analyzers. Vital Signs Simulators. Electrical Safety Analyzers

LASER SLIT LAMP. Optimized for Retina

Brighten The World With

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

700TSU INSTALLATION MANUAL

LIFEPAK CR PLUS/EXPRESS Defibrillator TABLE OF CONTENTS

Dräger UCF 9000 NFPA Certified Thermal Imaging Camera

Contents. - i - Ver.:2

Cardiostart. Biphasic Defibrillator Monitor

High Definition VideoScope

Removal and Installation8

Operating Microscope OM-18. A i m i n g a t n e w l e v e l s i n q u a l i t y

Mindray North America. Patient Monitoring FAQ s

Insignia - Icon SPARE PARTS CATALOG LASER MARKING SYSTEMS

MOBILE SAFETY DVR1543K. CLIP ON REARVIEW MIRROR KIT with 4.3-INCH LCD MONITOR FRONT & REAR CAR CAMCORDER with DUAL MOUNTING REVERSING CAMERA

Neonatal Care System. Infant Incubator Infant Warmer Phototherapy

PMI Borescope Lizard 100 Series User Guide

April 30, Dear Health Care Professional:

Unpacking and Installing the Flora 2512 UV Printer. Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place.

A TOPCON EXAM SOLUTION. Topcon Slit Lamp Series.» Quality» Precision» Durability

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components...

Hardware and Components: Philips Monitors in Critical Care

Non-Contact Depth Measuring Microscope System DH2/IMH

Resusci Anne Advanced SkillTrainer

HIPP Endoskop Service GmbH >> your requirements are our aims. HIPP Video Borescope Series VB. Technical Product Information

Global Service. Product Catalog Cardiac Assist

Borescopes. Endoscopy with highest image quality

INSPECTION TOOL. Wireless Inspection Camera with Recordable Monitor. EU Environmental Protection. Model: 8802AL, 8803AL. Model: 8802AL, 8803AL

TRANQUILITY VS VERSATILITY IN VITAL SIGNS A M E R I C A S TRANQUILITY VS A M E R I C A S

VX85 Slit Lamps. Precision at high level. Electric height adjustment VX85

is your system The System Unique features to meet the individual needs of surgical specialties. The System Approach to Electrosurgical Excellence

FengMi Wemax One Laser Projection TV

Contents LARYNGOSCOPES. HD Laryngoscope Rigid Laryngoscopes...ENR-105 ENR-110. Telescopes for Larynx Surgery...ENR-125 SINUSCOPES

AOC MONITOR USER`S GUIDE V22+ SAFETY INTRODUCTION.2 SETUP.4 ADJUSTING...7 DRIVER INSTALLATION GUIDE.. 10 PRODUCT INFORMATION.16 TROUBLESHOOT...

User Manual. Trinocular Stereo Microscope

Rigid Endoscopy. Jenny Rayne Buyer

User's Guide. Video Borescope. Models BR200 and BR250

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE

Thin, compact and lightweight just 20mm thin High-Speed Start-Up in approx. 0.9 sec 3x optical flat zoom mm Zoom 3.2 Megapixel Stylish design

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Amendment No: 2 Date: 13/09/2013

Propaq Vital Signs Monitors

Product Specifications

User Manual. SSA-20 - CO 2 Incubator Analyser

VX70. Slit Lamps. Stereo Microscope

V-MUX CONNECTOR and ACCESSORY SPEC

British Medical Auctions

Tesla M3 MRI Patient Monitor

5.6" Multi-function Monitor

FastCam Outdoor Speed Dome Camera

USER GUIDE. Waterproof Borescope. Models BR300 and BR350

User Guide. Video Borescope. Models BR200 and BR250

Symbols Glossary Rev. 1 1 / 16

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

Aspera R7. User Manual

Standard Operating Procedure For The Kaye Validator 2000 Thermal Mapping System

EV3.0 CAMERA CONTROL UNIT

Rigid endoscopes. Endoscopy with the highest image quality

LED Accu Penta 9x12W RGBWAU

MONITOR VITAL SIGNS W/SPO²,W/CAPNO TOC

User Manual. Trinocular Stereo Microscope

QUICK START GUIDE LENS CHANGING GUIDE

Linkam Scientific Instruments

The perfect combination

Transcription:

Endoscopes Inspection Report Sale: 1406 Date: 13 / 05 / 2014 (Condition Reports for other items at the end of the Scopes Report) These reports are compiled by our Medical Engineering Team & are for guidance only; all lots are sold as seen, as per our Conditions of Sale. We recommend that wherever possible you inspect lots prior to purchase. Lot Description Condition 110 OLYMPUS CF-1T200L Video Scope 1600x15mm 111 OLYMPUS CYF-4A Direct View 350x5.54mm 112 FUJINON UG1-FP2 Direct View 1000x10.30mm 113 OLYMPUS BF TYPE P30 Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition and image quality are good Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition and image quality are good Insertion tube Fair condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Average condition as some physical damage is present Image Quality Fair image Working Channel (s) Clear Leak test Leaking Over all condition Overall physical condition and image quality are in fair condition but scope is leaking Insertion tube Fair condition but has kinks on the insertion tube near the control box Bending mechanism & Angulation control Good movements Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition

Direct View 540x5.58mm 114 OLYMPUS CYF-4A Direct View 350x5.65mm 115 OLYMPUS CYF-4 Direct View 350x5.78mm 116 OLYMPUS BF TYPE 240 Video Scope 500x6.20mm 117 OLYMPUS CYF TYPE 240 Image Quality Poor image with 50+ fibres missing and water damage Working Channel (s) Clear Leak test Fail - Leaking Over all condition Overall physical condition is fair but the image is poor, water damage is visible and has 50+ fibres missing Insertion tube Fair condition but has a kink on the insertion tube near the control box and there is a dent near the distal end Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair but the image is good Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is good and the image quality is good Insertion tube Fair condition but dent along the insertion tube Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good condition Image Quality Image is average but the light does not focus and therefore shows bright regions on the output image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair but the image quality is poor as the light is not focused and shows bright patches Insertion tube Fair condition but has a kink near the control box Bending mechanism & Angulation control Movements and locks are functional but is stiff Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Not functional Distal end Good condition

Video Scope 350x5.75mm 118 OLYMPUS CYF TYPE 240 Video Scope 350x5.65mm 119 OLYMPUS CYF TYPE 240 Video Scope 350x5.48mm 120 OLYMPUS CF-200S Videoscope 600x14.80mm 121 OLYMPUS CF-240AL Videoscope 1600x12.90mm Image Quality Image is poor as the image is blurred Working Channel (s) Clear Leak test Fail- Leaking Over all condition Overall physical condition is fair but the image quality is poor as the image is blurred and the scope is leaking Insertion tube Fair condition but has a kink near the control box Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair and the image quality is good. Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches Functional Distal end Good condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Overall physical condition is fair and the image quality is good. Insertion tube Satisfactory condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Satisfactory overall condition Insertion tube Good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Pass

122 OLYMPUS BF-P30 Direct view 500x5.30mm 123 OLYMPUS SIF-230 Videoscope 2000x12.00mm 124 OLYMPUS CF-240AL Videoscope 1600x13.0mm 125 OLYMPUS CF-H260AZL Videoscope Over all condition Good overall condition Insertion tube Good condition Bending mechanism & Angulation control Good movement Light guide cable & Light transmission Good Objective lens and focusing Satisfactory Remote control switches N/A Distal end Good condition Image Quality Below satisfactory, bad water damage to whole image and 25+ fibres missing Working Channel (s) Clear Leak test Leaking Over all condition Below satisfactory overall condition as scope has water damage and 25+ fibres missing to image, also the scope is leaking Insertion tube Satisfactory condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Leaking when movement controls are moved to maximum Over all condition Good overall condition, however there is a leak when movement controls are moved to maximum Insertion tube Very good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Pass Over all condition Very good overall condition Insertion tube Very good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Unable to test as do not have the correct pigtail to test with Remote control switches Unable to test as do not have the correct pigtail to test with Distal end Satisfactory condition Image Quality Unable to test as do not have the correct pigtail to test with Working Channel (s) Clear Leak test Leaking

1600x14.10mm Over all condition Good physical condition, unable to test scopes working condition as do not have the correct pigtail to test with. The scope however is leaking 126 OLYMPUS GIF-PQ20 Insertion tube Satisfactory physical condition slightly stained in colour and slight dent near bottom of insertion tube Bending mechanism & Angulation control Good movement and locks Direct view Light guide cable & Light transmission One of the light outputs is not functional Objective lens and focusing Good optics, however there are 15 fibres missing from image Remote control switches N//A Distal end Satisfactory physical condition Image Quality Satisfactory image as there are 15 fibres missing from image Working Channel (s) Clear 1000x9.90mm 127 OLYMPUS PCF-230 Videoscope 1300x12.0mm 176 VISION SCOPE - Direct View 280x3.22mm 177 VISION SCIENCES ENT 2000 Leak test Leaking Over all condition Below satisfactory physical condition, 15 fibres missing from image, one of the light outputs is not functional and scope is leaking Insertion tube Good condition Bending mechanism & Angulation control Good movement and locks Light guide cable & Light transmission Good Objective lens and focusing Good optics Remote control switches Fully functional Distal end Satisfactory condition Image Quality Good image Working Channel (s) Clear Leak test Leaking Over all condition Good condition, scope is leaking Insertion tube Poor condition where there is a dent along the tube, kinks near the control box and the outer insulating sheath near the distal end is missing Bending mechanism & Angulation control Good movements Light guide cable & Light transmission Both light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Fair condition Image Quality Fair image but there is slight water damage visible on the image near the edge Leak test Unable to test as there is no connector at time of testing Over all condition Overall physical condition is poor due to the condition as the insertion tube but the image is fair but slight water damage is visible Insertion tube Poor condition where there is a dent along the tube and kinks near the control box Bending mechanism & Angulation control Good movements Light guide cable & Light transmission Light channels are functional

Direct View 300x3.49mm 181 OLYMPUS CYF-4A Direct View 350x5.56mm Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Leak test Pass Over all condition Overall physical condition is poor but the image quality is good Insertion tube Good condition Bending mechanism & Angulation control Good movements and locks Light guide cable & Light transmission Both the light channels are functional Objective lens and focusing Functional Remote control switches N/A Distal end Good condition Image Quality Good image Working Channel - Clear Leak test Pass Over all condition Overall physical condition is good and the image quality is good

Condition Report Sale: 1406 Date: 13 / 05 / 2014 These reports are compiled by our Medical Engineering Team & are for guidance only; all lots are sold as seen, as per our Conditions of Sale. We recommend that wherever possible you inspect lots prior to purchase. Lot Description Number 1 Datascope System 98XT Balloon Pump with 1x Box of Acessories 2 Zeiss Operating Microscope 3 Haag-Streit 900 Slit Lamp with Table and Accessories Case 4 Drager Fabius Anaesthetic Machine Report Powers up display screen and control panel are in good working order and the printer is also functional. Doppler is included and the gas cylinder and adult condensate removal/safety disk are in place. Overall the unit is in good physical condition. Not fully tested. Includes manual, ECG lead set and a spare gas cylinder. Operating hours: 2198. The operating microscope powers up, with unit able to produce a good light output. The mechanical movements and locks are in working order. The operating microscopes optical system shows to produce a clear image, with unit showing to have good focusing with the magnification functional. The unit is in fair physical condition. The slit lamp is able to power up, with it able to produce a light output. The fixation light is in place and shows to function. Units joystick movements shows to be freely movable, with its lock functional. Units chin rest is in place and its chin adjustment is in working order. The slit lamps tables mechanical height adjustment is in working order. The slit lamp is missing its eyepieces, however a set of eyepieces were used for tested purposes and showed the rest of the optical system to be able to produce a clear image. Overall the slit lamp is in satisfactory physical condition, with the side compartment on the table missing its door. The anaesthetic machine was tested using a medical compressor and the anaesthetic machine showed to have its gauges and flow meters in working order. The anti-hypoxic safety feature is in working order and the O2 flush is functional. The gas cut off alarm is functional. The anaesthetic machine includes O2, air and N2O hoses. The unit is in good physical condition. Manufacture date: 2001 6 Zeiss OPMI-1 Operating Microscope The power supply comes on and all the selected outputs power is working. The lamp is working fine. The optical system needs cleaning up but still with fair magnification and focus. All mechanical movements and locks are functional. Magnification range 0.4 to 2,5 and eye pieces 12,5x. Objective lens f=200. System is in fair overall physical condition.

7 Medtronic Lifepak 20 Defib With ECG Leads x1 8 Aloka Echo Camera SSD-500 Ultrasound with Probe Aloka 7.5MHz 10 Pfizer Valleylab Force 30 Diathermy (No Foot Switch) 16 Zoll M Series Defibs x 2 24 Wolf Stack Trolley With Panasonic M2080 Monitor, Wolf 5512 Processor, Wolf 5124 Light Source, Wolf Camera Head and Wolf 2232 Laparo CO2 Insufflator The defibrillator powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The defibrillator is testes using a defibrillator analyser and the output energies are within the limits. The AED and manual mode are in good working order. The ECG signal is tested using an ECG simulator and, the defibrillator appears to give good strong traces of ECG signals. Pacer option is included, which has not been fully tested but appears to be functional. Printer is functional. The service indicator stays on. Includes III lead ECG, AED therapy cable and two defibrillator pads (expire 03/2014 and 04/2014). The overall physical condition is reasonable. The defibrillator is a Biphasic unit and its Y.OM is 2004. The ultrasound powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The ultrasound is tested using a phantom and set measurements taken are within the limits. The resolution is average. Ultrasound includes modes B and M, which are in good working order. The probe (model: UST- 5512U-7.5MHz) is in good physical condition and is intact. Overall physical condition is fair. The diathermy powers up well and passed its initial self-test. The display and function buttons are in good working order. Some of the function buttons has some wear and tear. The diathermy has not been fully tested but the patient monitoring system is in good working order. No footswitches are included. Overall physical condition is reasonable. Both the defibrillators powers up well, its display, functions and function buttons are in good working order. The defibrillators have been tested using a defibrillator analyser and the output energies are within the limits. The ECG is tested using an ECG simulator and the defibrillators give good strong traces of ECG signals. The pacer option is included, which has not been fully tested but appear to be functional. The printer is functional. The defibrillators include two batteries which appear to be flat and are in need of charge. Two AED therapy cables are included but no ECG leads are included. Overall physical condition is reasonable. All units power up. The processor and camera head are able to produce a satisfactory image on the Panasonic monitor, with the camera head also showing to have satisfactory focusing. The light source is able to produce a good light output, with its brightness adjustment in working order. The insufflator has not been tested but is able to power up ok. Overall lot is in satisfactory physical condition.

25 Smith and Nephew Stack System Sony Trinitron Monitor PVM-20L2MD, 640 Image System 300 XL Xenon Light Source, 350 3-CCD Camera Operator and Camera Head, Sony Colour Video Printer UP-21 MD (037097) 28 Philips Intellivue MP70 Patient Monitors x2 29 Datex Capnomac Ultima Patient Monitors x2 30 Penlon AV900 Ventilator 31 Penlon AV900 Ventilator 34 Graseby 3400 Syringe Pump, 3200 Syringe Pump and Ivac P6000 Syringe Pump x2, Dinamap Pro 100V2 Patient Monitor and Nellcor NBP-4000 Patient All units are able to power up. The camera head and processor are able to produce a satisfactory image on the Sony monitor, with the camera head also showing to have satisfactory focusing. The light source is able to produce a good light output with its brightness control functional. The 640 image management system is able to power up and works on the National Display Systems flat screen, but in the boot up unit displays message CMOS checksum error which is able to be passed. Unit is able to power up successfully and shows to be functional. The color video printer is functional. Overall lot is in satisfactory physical condition. Image management system Version: 2.3 The two patient monitor s powers up well and passed its initial selftest. Its display and LCD touchscreen are in good working order. The monitors do no detect the multi-parameter and recorder modules. Therefore unable to carry out any further checks. No leads are included. Overall physical condition is reasonable. Y.O.M is 2004 and 2005. Software Versions are: REV B.05.67 and REV F.01.42 Both monitors power up ok and the display screens and control panels are in good working order. CO2 functions appear to working but gas monitoring functions have not been tested. Overall the units are in reasonable physical condition. The alarm silence buttons on both monitors have been worn out. The ventilator powers up well and passed its initial self-test. The display, LCD touchscreen and function buttons are in good working order. The unit has not been fully tested but appears to be functional. Oxygen hose is included. Overall physical condition is as there are scratches on the top cover. S/W is V3.11 The ventilator powers up well and passed its initial self-test. The display, LCD touchscreen and function buttons are in good working order. The unit has not been fully tested but appears to be functional. No hoses are included. Overall physical condition is reasonable. S/W is V3.30 One of the IVAC syringe drivers is not powering up neither is the Dinamap. The Nellcor power s up but the display is not displaying anything. The rest of the units included in lot are powering up with their function buttons and displays looking to be in working order. None of the units have been tested. The lot is in fair physical condition, with the Dinamap s printer door missing, and part of the Nellocrs handle missing. No accessories included with lot.

Monitor 41 Huntleigh Flowtron Pumps x5 43 Storz Stack Trolley with Storz 20090231 Monitor. NDS Radiance Monitor, Storz Xenon Nova 20131520 Light Source, Storz Image 22200020 Camera Control Unit, Storz CD Re-Writer and Keeler Headset 44 Valley Lab Force 2 Diathermy - No Pedals 45 ATL HDI 5000 Ultrasound with Mitsubishi CP200,C5-2,L12-5 and C8-4V Probes 50 GE Dash 4000 Patient Monitor, Datex Ohmeda S/5 Patient Monitors x2 (Damage to One) Unable to check to units as their plugs are missing, the other three units power up, with pumps looking to function however they have not been fully test. Overall the lot is in reasonable physical condition. All units are able to power up. Unit does not include a camera head so unable to test the processor. The light source is missing its interchangeable light guide adaptor; however the light source is able to produce a good light output. The imaging unit is able to power up, and then is able to open the AIDA compact programme but it fails to fully load as message No dongle found is displayed which is unable to be passed. The head gear is able to power up and is able to produce a light output with its brightness adjustment functional. Overall lot is in satisfactory physical condition. The diathermy has its switch missing, therefore unable to power up and carry out any further checks. No footswitches are included. Overall physical condition is fair. The ultrasound powers up but does not go into its main menu screen, therefore unable to carry out any further checks. The lot includes four probes (models: L7-4, C5-2, L12-5 and C8-4v), which are physically intact but have not been tested. Printer is included, which powers up but has not been tested. Overall physical condition is reasonable. The three patient monitors power up well, and passed its initial selftest. The Dash 4000 powers on for a few minutes but turns itself off; also its display monitor has lines running through the LCD screen. The Datex Ohmeda (S/N: 4293223) has many pixels missing and therefore unable to clearly read the display monitor. The monitor appears to be functional, where it s ECG and NIBP are tested but has not been verified, unable to test the SPO2 as display set up is needed to be accessed but difficult to read the display monitor. This monitor has a number of cracks along the casing and its rotary knob is missing. Recorder is missing but parameters IBP, ECG, SPO2, Temp and NiBP are included. The other monitor (S/N: 4749116) is in good working order where its ECG is fully tested using an ECG simulator and is functional. The NiBP and SPO2 appear to be functional but have not been fully tested. The printer is included and functional. Included parameters NiBP, ECG, SPO2, IBP, CO2 and Temp. Two batteries are included but are flat and in need of a charge. Lot includes x1 AC adaptor but no leads are included. Overall physical condition is average due to usage.

65 Datex Ohmeda Aestiva 3000 Anaesthetic Trolley with Ventilator The anaesthetic machine powers up ok and the pressure gauges, flow meters, O2 flush; Basel flow and anti-hypoxic safety feature are all in good working order. The 7900 Smart Vent powers up ok and completes the system self-test successfully. The function buttons are working fine but the display has several pixels out, however the displayed values are not affected. The ventilator was tested with test lung and medical air and the set parameters and alarm limits were working fine. The flow and oxygen sensors are working fine. The absorber, bellows and rebreathing assembly are in good condition with no leak detected during test run. The backup battery for the Smart Vent is functional. Overall, the system is in good physical condition. O2, Air, N2O hoses and AGSS receiver are included 66 SLE 2000 Infant Ventilator with SLE 2100 Respiration Monitor 68 Eschmann TD850 Diathermy with Yellow and Blue Foot Switch on ST80 Suction Trolley and Lina Smoke Evacuator 69 Olympus CLE-4U Light Source and Atlantech Xenon Fibre-Optic Light Smart Vent Software Version: 3.2 The ventilator powers up, with its function buttons and numerical displays in working order. Unit is missing its expiratory block, but one was used for test purposes. The ventilator showed to be functional, when it was tested using a medical compressor. The ventilator showed to be functional in all ventilation modes. Units output has not been verified to see if it is within set limits. Unit oxygen is able to calibrate to 21%. Unit includes O2 and air hoses. The SLE 2100 is able to power up, with it then passing through its initial self-test successfully. Units display is functional and the function buttons look to be responding. The SLE2100 has not been tested. The humidifier is also powering up but again has not been test. The lot is in satisfactory physical condition. Vent modes: SIMV, PTV, CMV and CPAP Operation hours: 12835.53h The diathermy powers up well, its display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) output results are out of limits. Bipolar is not tested as there are no footswitches. Includes monopolar footswitches (cut and coag). The ST 80 suction has its mains cable cut off and therefore unable to fully test. The Lina suction powers up and appears to be functional but has not been fully tested. Overall physical condition is reasonable. Both units are able to power up, however neither unit was able to produce a light output. The Olympus CLE-4U has its air feeding pump functional. Units are in below satisfactory physical condition.

Source 70 Medtronic Lifepak 20 x1, Physio Control Lifepak 9 with Shock Advisory Adapter x1 Lifepak 20 The defibrillator is able to power up and is able to pass through its initial self-test successfully. Units function buttons, rotary knob and display are in working order. Unit does not include any paddles but does include (1x) AED cable. Units output was tested using a defibrillator analyser and all readings taken showed to be within set limits. Unit was functional in both manual and AED modes. Unit was able to charge to 360J in manual mode. The defibrillator is biphasic. The audio voice prompts are functional. Unit includes 3 wire ECG leads and units ECG was verified as functional. Units printer is functional but the battery is not. Unit is in good physical condition. Lifepak 9 The defibrillator is able to power up, with its function buttons and display in working order. Unit does not include any paddles but includes a shock advisory adaptor and AED cable. Unit has not been fully tested. Unit was able to give a test output of 360J, but the output has not been verified. Only manual mode has been checked. The shock advisory adaptor has not been checked. Unit includes (1x) 3 wire ECG and units ECG has been verified as functional. Units printer is functional and the battery is low. Unit is in fair physical condition. 74 Drager Oxylog 2000 Portable ventilator 76 Graseby 3200 Syringe Pumps x5, Graseby 3100 Syringe Pumps x3 and Alaris GH Syringe Pump and Abbot Flexiflow Lifepak 9 manufacture date: 1999 Lifepak 12 manufacture date: 2006 Unit power up and system self-test completed successfully. The lithium battery and mains charger is in good working order. LCD and controls are functional. Airways pressure indicator and alarm setting are working fine. The ventilator modes include: IPPV, SIMV, CPAP and SIPPV and they all appears to be functional. Test run with medical air compressor and test lung, indicates that all parameter and alarm settings were in good working order. The minute Volume (MV) was verified with the set valve of Tidal volume and Frequency (BPM) and found to be within limit. The system is in good physical and cosmetic condition. Oxygen hose with schrader connector is included. The Alaris Plus syringe driver is not power up and one of the Graseby 3100 displays fault 86 which is not able to be passed. The rest of the units are able to power up, with their function buttons and displays in working order. Units have not been tested. The lot is in fair physical condition.

Enteral Pump 88 Olympus PSD 20 Diathermy with Foot Switch 92 Cardiac Science AED Trainer x2, Lifepak CRT Trainer x1 103 Omega Excel Laser System with 1 x Probe, Manual and Key 142 Smith and Nephew 30º Autoclavable Rigid Scopes x 4 143 Smith and Nephew 30º Autoclavable Rigid Scopes x 4 144 Smith and Nephew 30º Autoclavable Rigid Scopes x 4 145 Smith and Nephew 30º Autoclavable Rigid Scopes x 4 175 Olympus MAJ-554 Camera Head Unit is able to power up, with it numerical displays in working order and its function buttons looking to respond. Unit has not been tested with its output not checked. Units patient plate alarm is functional. Unit includes (1x) footswitch for monopolar cut/coag, which looks to be responding. Unit is in good physical condition. The lifepak CR-T does not include a battery so unable to determine if the unit is able to power up. Both the Cardiac trainers are able to power up, however only one of the units includes batteries. Both units displays are functional. Both units voice prompts are functional. Both units were tested on a defibrillator analyser, one unit was unable to find a signal the other unit was able to find a signal but then no actual output (0J) was recorded when a shock was delivered. Overall lot is in satisfactory physical condition. The laser unit powers up well and passed its initialization phase. The display, functions and function buttons are in good working order. The beam test was conducted and appears to be in good working order. Includes probe which is in good working order (200mW and lambda 820nm). Key is included. Overall physical condition is fair. Y.O.M 2001 The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. The four rigid scopes appear to be physically intact and are inclined at 30 degrees. Four of the rigid scopes do not produce a good output image. Overall physical condition is reasonable. Unable to test the camera head as there is no processor to test with. The Camera head looks to be intact and in satisfactory physical condition.

178 Downs 0 Rigid Scope with Light Lead 183 GE 4C-RS Curved Array Convex Probe 184 GE RNAS-9-RS 3D Micro-Convex Probe 185 GE 11L-D Linear Probe 187 Philips C5-1 Ultrasound Probe - BOFN912 188 Qty of Urology Instruments to Inc. Storz Resectoscopes with Obturator, Comeg Cystoscope, Ellick Connectors 195 Aloka UST-9123 Convex Ultrasound Probe 196 Storz Hopkins 7200 30º Rigid Scope 200 Olympus OTV-S6 Camera Head 235 Pentax LH 150FP Light Source The rigid scope is physically intact and gives a good output image. The light source cable is included which appears to be intact. Overall physical condition is fair. GE Curved Array Convex Probe, 4C-RS (year 2007) -The probe connection, cable and head are intact and in good physical condition; but not tested due to unavailability of suitable unit. The probe is compatible with model GE Logiq e, Vivid e & Vivid i ultrasound system. GE 4D Micro-convex Probe, RNA5-9-RS (year 2009), Frequency range: 3.3 to 9.1 MHz. The probe connection, cable and head are intact and in good physical condition; but not tested due to unavailability of suitable unit. The probe is compatible with model GE Voluson I ultrasound system. Unable to test the probe as there is no ultrasound to test with. The probe looks to be intact and in satisfactory physical condition The probe has not been tested on a compatible ultrasound. Therefore unable to carry out any further tests. Overall physical condition is reasonable but near the scan head it has been taped previously. (Note the probe has been tested on iu22 and HD11XE and was not detected) Lot is in satisfactory physical condition, lot is incomplete consisting of various pieces. The probe is in good physical and cosmetic condition and the scanhead is physically intact. A compatible ultrasound is not available therefore the probe cannot be tested. The rigid scope is physically intact but does not give a good output image. The rigid scope is inclined at 30 degrees. Overall physical condition is fair. Unable to test camera head. The camera head is missing its lens adaptor. The camera head is missing its rubber grommet at the bottom of the camera head causing a large section of the inner insulation to be exposed. The camera head is in below satisfactory physical condition. The light source powers up, with its function knobs in working order. The light source is able to produce a light output with its brightness

239 Bayer Clinitek 50 Analysers x2 (1 Spare only) 246 Blease Frontline 690 Anaesthetic Machine with 8200s Ventilator 248 Smith and Nephew Stack Trolley with Sony LCD Monitor, Smith and Nephew 660 HD Image Management System, Dyonics 300XL Xenon Light Source, Smith and Nephew 460P 3-CCD Digital Camera Control Unit, HP Printer and Camera 252 Olympus TK-E1 Trolley with Olympus CV240 Control Unit with Pigtail and Olympus CLV-U20 Light Source 259 Sensor Medics 3100A Oscillatory Ventilator with Fisher and Paykel MR700 Humidifier adjustment functioning. The air pump appears to be functioning. The light source is in fair physical condition for unit s age. Unable to power up units as lot does not include correct power cables. Units are in reasonable physical condition with one unit missing its printer cover. The anaesthetic machine has not been tested but shows to have its flow meters and gauges intact. The ventilator also has not been tested but showed to be able to power up with its numerical displays functioning. Unit s bellows and absorber are in place. Unit includes an AGSS receiving system and hose and a high flow high vacuum regulator and hose. The unit is also complete with O2, air and N2O hoses. Overall the unit is in fair physical condition. All units power up, with the function buttons functional. The camera head and processor produce a satisfactory image on the Sony flat screen monitor, with the camera head also showing to have satisfactory focusing. The light source is able to produce a good light output with its brightness adjustment functional. The image management system showed to have its touch screen display functional with the unit showing to be in working order. The printer powers up. Overall lot is in good physical condition. Image management system version: 1.5 All units on the Olympus trolley power up ok. The light source xenon lamp is working fine and light output model selector (OES, EVIS 100 & EVIS 200) are fully functional. Brightness control in auto and manual mode are working fine. The video processor with the video cable MH977 are in good working order when tested with a videoscope. All the function keys and video controls are working. Good quality image was displayed when connected to a colour monitor. The system is in good overall physical condition. The ventilator is able to power up, with its function buttons/dials and the numerical displays showing to function. The ventilator has not been tested. The oxygen blender monitor is in place but unable to verify if it is powering up. The humidifier is powering up with its function buttons/dial and numerical display functioning, however again unit has not been tested. The ventilator includes O2 and air hoses. Overall the lot is in fair physical condition. Operation hours: 11278.7

260 Sensor Medics 3100A Oscillatory Ventilator with Fisher and Paykel MR700 Humidifier 261 Blease Frontline 440 Anaesthetic Machine with 8200s Ventilator and Marquette Solar 8000 Patient Monitor 265 Nihon Kohden Cardiofax Q ECG Recorder with ECG Lead 266 Nihon Kohden Cardiofax GEM ECG Recorder with ECG Lead 278 Smith and Nephew Stack Trolley with Sony LCD Monitor, Smith and Nephew 660 HD Image Management System, Dyonics Xenon XL Light Source, Smith and Nephew 460P 3-CCD Digital Camera The ventilator is able to power up, with its numerical displays in working order. The silencing alarm function button is not functioning unable to determine if the rest of the function buttons are responding. The ventilator has not been tested. The Air-oxygen blender is in place. The humidifier is powering up but does not appear to be functioning with unit not responding and only displaying EOo on the numerical display. The ventilator includes O2 and air hoses. Overall the lot is in fair physical condition. Operation hours: 10897.3 The anaesthetic machine has not been tested but shows to have its flow meters and gauges intact. The oxygen monitor shows to be powering up with its function buttons and display in working order. The ventilator is also powering up with its numerical displays functioning. Again the ventilator has not been tested. The units bellows and absorber are in place. Unit includes an AGSS receiving system and hose and a high vacuum regulator and hose. The unit is also complete with O2, air and N2O hoses. The patient monitor is able to power up but however does not include any modules, unable to test unit. Overall the lot is in reasonable physical condition. The ECG machine powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The ECG machine has not been fully tested but appears to be functional. The printer and battery is in good working order. Includes 12 lead ECG wire. Overall physical condition is fair. The ECG machine powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The ECG machine has not been fully tested but appears to be functional. The printer and battery is in good working order. Includes 12 lead ECG wire. Overall physical condition is fair. All units power up, with function buttons functional. The camera head and the processor are able to produce a good image on the Sony flat screen monitor, with the camera head also showing to have good focusing. The light source is able to produce a good light output with its brightness adjustment functional. However the light sources power switch is loose. The image management system showed to have its touchscreen display in working order with the unit showing to be in working order. The printer powers up. Overall the lot is in satisfactory physical condition. Image management system version: 1.5

Control Unit, Camera Head and HP Printer 279 Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches 280 Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches 286 Kodak Dryview 8150 Laser Imager 287 Fisher and Paykel Cosy Cot Resusitator 288 Fisher and Paykel Cosy Cot Resuscitator 294 Stryker Resus Trolley -30109 The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. However the pure cut mode on the higher output appear to be out of range otherwise all the other modes are within the range. Includes monopolar (cut and coag) and bipolar footswitches. The suction unit powers up but the suction is not functional, therefore unable to carry out any further tests. The overall physical condition is reasonable. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The suction is in good working order but output has not been verified. The overall physical condition is reasonable. The unit powers up however the display panel is not functional, so unable to do anything with unit. Unit is in satisfactory physical condition. Unit powers up, with its indication lights and display in working order. Units function buttons are functional however the manual mode function button is missing its button cover. Unit showed to heat up well in Prewarm and manual modes. unit does not include a skin temperature probe. Units overhead light and timer both showed to be functional. The neopuff section of the unit has not been tested. Units electrical height adjustment is in working order. Unit includes O2 and air hoses and a mattress. Overall unit is in satisfactory physical condition. Manufacture date: 2007-01 Unit powers up but immediately alarms and gives an error message Er 017. The error message is unable to be passed. No further checks are able to be carried out on the unit. The neopuff section of the unit has not been tested. Unit include O2 and air hoses and a mattress. Unit is in satisfactory physical condition Manufacture date: 2004-01 The patient trolley is physically intact; its upholstery is in good condition. All articulating movements are in good working order. Its

302 Fresenius 4008s Hemofiltration Machine 303 Welch Allyn Patient Monitors on Stands with SPO2 Leads 308 Medelac Saphire 2M and DP Medical Light Source 311 Braun Dialog Dialysis Machine x 2 312 Braun Dialog Dialysis Machine x 2 315 Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches 316 Conmed Excalibur Plus Diathermy on Suction Trolley with Blue, Yellow and Black Foot Switches height adjustment is functional. The side rails are intact. The brakes are in good working order. Overall physical condition is reasonable. Unit is not powering up with unit only able to give a constant alarm. Unit includes modules, double blood pumps, heparin pump, air detector and BiBag. The Bibag module panel cover is completely missing. Unit includes water and drainage hoses. Overall the unit is in fair physical condition. Manufacture date: 2010 Operation hours: 8972.03 The three vital signs monitor power up well, its display, functions and function buttons are in good working order. The NiBP pump and SPO2 is functional but has not been fully tested. Lot includes two NiBP cuffs. Battery is in good working order. Overall physical condition is fair. Medelec Sapphire II. Powers up ok - display screen and controls are in good working order and the printer is also functional. No further checks carried out. Lot includes a DP Medical 202032 light source which is in good working order. Overall the unit is in reasonable physical condition. Unable to power up units as both of the mains cables has been removed. Both of the units include (1x) single blood pump, (1x) heparin pump and (1x) air detector. Both of the units have their water and drainage hoses cut off from the bottom. Overall lot is in reasonable physical condition. Unable to power up units as both of the mains cables have been removed. Both of the units include (1x) single blood pump, (1x) heparin pump and (1x) air detector. One of the units includes water and drainage hoses the other unit has its water and drainage hoses missing. Overall lot is in reasonable physical. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The suction and its regulator are functional but the output has not been verified. The overall physical condition is reasonable. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The suction is

317 Drager 5400 Transport Incubator 322 Marquette Mac8 ECG Recorder with ECG Lead 325 Conmed Excalibur Plus Diathermy on Trolley with Yellow, Blue and Black Foot Switches 326 Drager D-Vapour Desflurane Vapouriser functional but the regulator is not functional an unable to change the suction output. The overall physical condition is reasonable. The Transport incubator 5400 power up ok on mains; battery power has not been tested. The incubator set temperature is maintained accordingly. The BabyMix 2 ventilator is in good physical condition but not fully tested. The Oxygen monitor Oxydig has no battery, not tested. The lot is in fair overall ohysical condition. Unit is able to power up after a long period of time. Then the unit shows to have its function buttons in working order. Units display functions however the display flickers which makes it hard to read in places, with some lines of pixels missing. Unit makes a loud constant humming noise. Unit has not been tested. Unit includes 12 wire ECG however all of the leads are missing their end connection pins. Unit is in reasonable physical condition. The diathermy powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The diathermy is tested using an ESU analyser and the monopolar (cut and coag) and bipolar output readings are within the limits. Includes monopolar (cut and coag) and bipolar footswitches. The overall physical condition is reasonable. The vaporiser is in good physical condition, with its volume control dial and lock intact. There are some minor marks to paintwork. 328 Drager Oxylog Portable Ventilator Unit power up when connected to medical gas. Airways pressure indicator working fine. Test run with medical air compressor and test lung, indicates that all parameter and alarm settings were in good working order. The minute Volume (MV) was verified with the set valve of Tidal volume and Frequency (BPM) and found to be within limit. The system is in fair physical condition. Oxygen hose with schrader connector is included. 361 The ultrasound is unable to power up. Unable to test the unit. Units (1x) probe appears to be physically intact. Unit is in reasonable physical condition, with its covers colour being worn away in large patches. 369 Drager 8000SC Incubator Unit is able to power up, with units function buttons and displays in working order. In Air mode unit showed to be functional, with unit able to reach and maintain the set temperature. Temperature output has not been verified. Unit does not include a skin temperature probe so unable to test skin mode. Humidifier mode has not been checked. Units electrical height adjustment and mechanical cot tilt are in working order. Unit includes a mattress. Unit is in satisfactory physical

condition. 374 Edwards Lifescience Aquarius Hemofiltration Machine 379 Sonosite 180 Plus with Probe 382 Zeiss IOL Master with Printer and Table 387 Haag-Streit Slit Lamp with Table 395 Quantel Medical Virdis Twin Laser with Key and Foot Switch, BMBQ Slit Lamp Adaptor Unit is able to power up, units function buttons, rotary knob and display show to be functioning. Unit has not been tested. The blood pump and filtrate cover panel is missing, also the prefillter sensor is bent and unable to close. Overall unit is in fair physical condition. Manufacture date: 2009 Software version: 6 The ultrasound powers on, but is not functional as the display gives a badly flickering display with no actual picture showing. Unable to check unit. Units (1x) probe appears to be physically intact. The ultrasound is in satisfactory physical condition. Manufacture date: 2004-08 The IOL Master powers up well and passed its initial self-test. The display, functions and function buttons are in good working order. The IOL Master is tested using a test eye and test results taken where within the limits. The functions included are Axial Length Measurement, Corneal Curvature Measurement and Anterior Chamber Depth Measurement, which are in good working order. Printer is functional. The height adjustment is in good working order. Overall physical condition is reasonable. IOL Master Version: 3.02.0304 The slit lamp is able to power up, with it able to produce a light output, the reflector mirror for the light output is in place but has a large chip at one corner. The fixation light is in place but however it is not functional and has its outer cover missing. The joystick movements show to be functioning but however is slightly stiff, the movement lock is functional. The chin rest is in place and its chin adjustment is functional. The slit lamps tables mechanical height adjustment is in working order. The slit lamps optical system is able to produce a clear image, with it also showing to have good focusing. Overall the slit lamp is in satisfactory physical condition, with the side compartment on the table missing its bottom panel. (1x) set of eyepieces (10x) Quantel Medical Viridis Twin, software version: M:10.02 B:10.00. Unit power up ok, the LCD screen and function keys are working fine. The aiming beam is working and the 532 nm laser function screen comes when the key is turned on. The parameters were adjustable for power, pulse etc. Test firing of the laser indicate green laser at the out but the power was not verified. When the key is turned to select 810

nm laser an error message is displayed E100A:0 fibre disconnected. Only one fibre cable with laser aperture is included with slit lamp adapter model: BMBQ. One YAG safety goggle is included. System is in fair physical condition. 396 Hill-Rom Air Shields Resusitaire - 001297 399 Stryker Endoscopy Trolley with Trinitron Monitor Q5000 Light Source, X6000 Light Source, 2 x Sony Colour Video Printer, 2 x 988i 3 Chip Camera Controller and 3 x 988i Camera Heads 400 Alcon Surgical Ultrasonic Imaging System with Monitor and Probe 10MHz and Foot Switch on Trolley 402 Eschmann TD411-S Diathermy with Foot Switches on ST80 Suction Trolley Unit powers up, with its function buttons, indication lights and numeric displays in working order. Unit showed to function with unit able to heat up in pre-warm and manual modes. In manual mode the heat adjustment is functional. Unable to test baby mode as unit does not include a skin temperature probe. Units exam light and timer are both functional. Units electrical height adjustment is functional as is the mechanical cot tilt. Units Suction and patient supply were checked using a medical compressor, and the suction and patient supply showed to be functioning with their gauges in working order. Unit includes O2, air and N2O hoses, unit also includes a mattress and suction jar. Overall unit is in satisfactory physical condition. All units are able to power up, with the function buttons functional. Both of the processors and two of the camera heads are able to produce a good image on the Sony monitor, with both camera heads showing to have good focusing. However one of the two camera heads does show some slight interference from the connection end if moved. The third camera head is able to produce a reasonable image however it is constantly affected with bad interference when the camera head is moved, the camera heads focusing is functional. Both of the light sources are able to produce a good light output with their brightness adjustments functional. Both of the color video printers are powering up. Overall the lot is in satisfactory physical condition. Bulb hours for Q5000: 205.2 Bulb hours for x6000: 183 Alcon Ultra Scan imaging System, software version: 3.00. Unit power up ok and the CRT display and keyboard are working fine. The ultrasound probe 10MHz is appears to be working with a scan image display on the screen. Unit is not fully tested. In fair physical condition. The diathermy powers up well and passed its initial self-test. The display, rotary knobs and functions are in good working order. The diathermy is tested using an ESU analyser and cut outputs are out of range whereas the coagulation modes are within the range. The bipolar mode has not been tested as there are no footswitches. Monopolar cut and coagulation footswitches are included. Overall physical condition