IBM Flex System FC port 8Gb FC Adapter IBM Redbooks Product Guide

Similar documents
Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide

IBM Flex System FC5024D 4-port 16Gb FC Adapter IBM Redbooks Product Guide

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide

IBM Flex System EN port 10Gb Ethernet Adapter IBM Redbooks Product Guide

Flex System FC port and FC port 16Gb FC Adapters Lenovo Press Product Guide

IBM Flex System FC port 16Gb FC Adapter Lenovo Product Guide

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

Flex System EN port 1Gb Ethernet Adapter Product Guide

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

Flex System EN port 10Gb Ethernet Adapter Product Guide

Flex System IB port FDR InfiniBand Adapter Lenovo Press Product Guide

Brocade 16Gb FC Single-port and Dual-port HBAs for System x IBM Redbooks Product Guide

Brocade 16Gb FC Single-port and Dual-port HBAs for System x IBM Redbooks Product Guide

Broadcom NetXtreme Gigabit Ethernet Adapters IBM Redbooks Product Guide

IBM 6 Gb Performance Optimized HBA IBM Redbooks Product Guide

Broadcom NetXtreme 10 GbE SFP+ Network Adapter Family for System x IBM Redbooks Product Guide

IBM Flex System EN Gb Ethernet Pass-thru Module IBM Redbooks Product Guide

N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide

IBM Flex System CN4054/CN4054R 10Gb Virtual Fabric Adapters and EN port 10GbE Adapter IBM Redbooks Product Guide

IBM High IOPS MLC Adapters IBM Redbooks Product Guide

2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide

Broadcom NetXtreme 10 GbE SFP+ Network Adapter Family for System x IBM Redbooks Product Guide

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

IBM Half-High LTO Generation 5 SAS Tape Drive IBM System x at-a-glance guide

IBM High IOPS SSD PCIe Adapters IBM System x at-a-glance guide

Broadcom NetXtreme II Dual Port 10GBase-T Adapter for IBM System x IBM System x at-a-glance guide

Emulex 10GbE Virtual Fabric Adapter II for IBM BladeCenter IBM Redbooks Product Guide

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

ServeRAID M5115 SAS/SATA Controller for IBM Flex System IBM Redbooks Product Guide

Emulex 16Gb Gen 5 Fibre Channel Adapters for IBM System x IBM Redbooks Product Guide

ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

S3700 SATA MLC Enterprise SSDs for IBM System x IBM Redbooks Product Guide

Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide

Intel I350 Gigabit Ethernet Adapter for IBM System x IBM Redbooks Product Guide

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide

Integrated Management Module (IMM) Support on IBM System x and BladeCenter Servers

QLogic 10Gb Virtual Fabric Adapter and CNA for IBM BladeCenter IBM Redbooks Product Guide

Best practices. Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster. IBM Platform Symphony

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide

Broadcom 10Gb 2-Port and 4-Port Ethernet Expansion Cards (CFFh) for IBM BladeCenter (Withdrawn) Product Guide

IBM Half-high LTO Generation 4 SAS Tape Drive IBM System x at-a-glance guide

IBM Flex System FC3171 8Gb SAN Switch and Pass-thru IBM Redbooks Product Guide

IBM High IOPS MLC Adapters Product Guide

iscsi Configuration Manager Version 2.0

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter Product Guide

Brocade 10Gb CNA for IBM System x (Withdrawn) Product Guide

Implementing IBM CICS JSON Web Services for Mobile Applications IBM Redbooks Solution Guide

Lenovo Flex System EN Gb Ethernet Pass-thru Product Guide

IBM Flex System Storage Expansion Node IBM Redbooks Product Guide

IBM PowerKVM available with the Linux only scale-out servers IBM Redbooks Solution Guide

Enterprise Caching in a Mobile Environment IBM Redbooks Solution Guide

ServeRAID H1110 SAS/SATA Controller Product Guide

Best practices. Reducing concurrent SIM connection requests to SSM for Windows IBM Platform Symphony

ServeRAID M5016 SAS/SATA Controller IBM System x at-a-glance guide

QLogic BS21, , and InfiniBand Switches IBM Power at-a-glance guide

IBM z/os Management Facility V2R1 Solution Guide IBM Redbooks Solution Guide

IMM and IMM2 Support on IBM System x and BladeCenter Servers

ServeRAID M5016 SAS/SATA Controller IBM Redbooks Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

Utility Capacity on Demand: What Utility CoD Is and How to Use It

Best practices. Linux system tuning for heavilyloaded. IBM Platform Symphony

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

Platform LSF Version 9 Release 1.1. Migrating on Windows SC

Optimizing Data Integration Solutions by Customizing the IBM InfoSphere Information Server Deployment Architecture IBM Redbooks Solution Guide

Elastic Caching with IBM WebSphere extreme Scale IBM Redbooks Solution Guide

IBM Ethernet Switch J48E

IBM License Metric Tool Enablement Guide

Flex System Storage Expansion Node Product Guide

CONFIGURING SSO FOR FILENET P8 DOCUMENTS

Intel X520 and X540-T2 Dual Port 10 GbE Adapters for IBM System x IBM Redbooks Product Guide

IBM Storage Device Driver for VMware VAAI. Installation Guide. Version 1.1.0

IBM XIV Provider for Microsoft Windows Volume Shadow Copy Service. Version 2.3.x. Installation Guide. Publication: GC (August 2011)

Broadcom NetXtreme Gigabit Ethernet Adapters Product Guide

Intel X520 and X540-T2 Dual Port 10 GbE Adapters for IBM System x IBM Redbooks Product Guide

IBM BigInsights Security Implementation: Part 1 Introduction to Security Architecture

Platform LSF Version 9 Release 1.3. Migrating on Windows SC

Application and Database Protection in a VMware vsphere Environment

Installing the Microsoft Hyper-V Failover Cluster on N series

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI

IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version Release Notes

IBM FlashSystem V Quick Start Guide IBM GI

Getting Started with InfoSphere Streams Quick Start Edition (VMware)

IBM Flex System FC Gb SAN Scalable Switches IBM Redbooks Product Guide

IBM Security QRadar Version Customizing the Right-Click Menu Technical Note

IBM Storage Driver for OpenStack Version Release Notes

DS8880 High Performance Flash Enclosure Gen2

Tivoli Access Manager for Enterprise Single Sign-On

IBM Flex System EN Gb Ethernet Switch IBM Redbooks Product Guide

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter

IBM emessage Version 8.x and higher. Account Startup Overview

Migrating Classifications with Migration Manager

Flex System PCIe Expansion Node Product Guide

IBM High IOPS Modular Adapters (Withdrawn) Product Guide

Contents. Configuring AD SSO for Platform Symphony API Page 2 of 8

Transcription:

IBM Flex System FC3172 2-port 8Gb FC Adapter IBM Redbooks Product Guide The IBM Flex System FC3172 2-port 8Gb FC Adapter enables high-speed access for IBM Flex System compute nodes to connect to a Fibre Channel storage area network (SAN). This adapter is based on the proven QLogic 2532 8Gb ASIC design and works with the 8 Gb and 16 Gb IBM Flex System Fibre Channel switches and pass-thru modules. Figure 1 shows the IBM Flex System FC3172 2-port 8Gb FC Adapter. Figure 1. IBM Flex System FC3172 2-port 8Gb FC Adapter Did you know? The performance bottleneck with Fibre Channel storage typically exists in the switching. By moving to 8 Gb adapters and switches, you can optimize the bottleneck to the storage controller, where it can be managed by expanding the disks attached to storage. When compared to the previous-generation 4 Gb adapters, the new-generation 8 Gb adapters double the throughput speeds for Fibre Channel traffic. As a result, you can manage increased amounts of data and possibly benefit from a reduced hardware expense. The adapter connects to the midplane directly, without having to use cables or small form-factor pluggable (SFP) modules. By eliminating these components for up to 14 servers, the resulting savings alone can cover the investment in the chassis. IBM Flex System FC3172 2-port 8Gb FC Adapter 1

Part number information Table 1 shows the part number to order this card. Table 1. Part number and feature code for ordering Description Part number Feature code (x86 servers) Feature ocde (Power Systems) IBM Flex System FC3172 2-port 8Gb FC Adapter 69Y1938 A1BM 1764 The part number includes the following items: One IBM Flex System FC3172 2-port 8Gb FC Adapter A documentation CD containing the adapter user s guide The IBM Important Notices document Features The IBM Flex System FC3172 2-port 8Gb FC Adapter has the following features and specifications: QLogic ISP2532 controller PCI Express 2.0 x4 host interface Bandwidth: 8 Gb per second maximum at half-duplex and 16 Gb per second maximum at full-duplex per port 8/4/2 Gbps auto-negotiation Support for FCP SCSI initiator and target operation Support for NPIV Support for full-duplex operation Support for Fibre Channel protocol SCSI (FCP-SCSI) and Fibre Channel Internet protocol (FCP-IP) Support for point-to-point fabric connection (F-port fabric login) Support for Fibre Channel Arbitrated Loop (FCAL) public loop profile: Fibre Loop-(FL-Port)-Port Login Support for Fibre Channel services class 2 and 3 Configuration and boot support in UEFI APIs supported: SNIA HBA API V2, SMI-S, FDMI Support for IBM Fabric Manager Power usage: 3.7 W typical RoHS 6 compliant IBM Flex System FC3172 2-port 8Gb FC Adapter 2

Supported servers The following table lists the IBM Flex System compute nodes that support the FC3172 2-port 8Gb FC Adapter. Table 2. Supported servers Description IBM Flex System FC3172 2-port 8Gb FC Adapter Part number 69Y1938 Y N Y Y Y Y Y Y Y Y Y See IBM ServerProven at the following web address for the latest information about the expansion cards that are supported by each blade server type: http://ibm.com/servers/eserver/serverproven/compat/us/ I/O adapter cards are installed in the slot in supported servers, such as the x240, as highlighted in the following figure. Figure 2. Location of the I/O adapter slots in the IBM Flex System x240 Compute Node IBM Flex System FC3172 2-port 8Gb FC Adapter 3

Supported I/O modules The FC3172 2-port 8Gb FC Adapter supports the I/O module listed in the following table. One or two compatible switches must be installed in the corresponding I/O bays in the chassis. Installing two switches means that both ports of the adapter are enabled. When the adapter paired with a 16Gb switch, those switch ports will operate at 8 Gbps. Table 3. I/O modules supported with the FC3172 2-port 8Gb FC Adapter Description Part number Support the FC3172 adapter IBM Flex System FC3171 8Gb SAN Switch 69Y1930 Yes IBM Flex System FC3171 8Gb SAN Pass-thru 69Y1934 Yes IBM Flex System FC5022 16Gb SAN Scalable Switch 88Y6374 Yes IBM Flex System FC5022 24-port 16Gb SAN Scalable Switch 00Y3324 Yes IBM Flex System FC5022 24-port 16Gb ESB SAN Scalable Switch 90Y9356 Yes The following table shows the connections between adapters installed in the compute nodes to the switch bays in the chassis. Table 4. Adapter to I/O bay correspondence I/O adapter slot in the server Port on the adapter Corresponding I/O module bay in the chassis Slot 1 Slot 2 Slot 3 (full-wide compute nodes only) Slot 4 (full-wide compute nodes only) Port 1 Module bay 1 Port 2 Module bay 2 Port 1 Module bay 3 Port 2 Module bay 4 Port 1 Module bay 1 Port 2 Module bay 2 Port 1 Module bay 3 Port 2 Module bay 4 IBM Flex System FC3172 2-port 8Gb FC Adapter 4

The connections between the adapters installed in the compute nodes to the switch bays in the chassis is shown diagrammatically in the following figure. Figure 3. Logical layout of the interconnects between I/O adapters and I/O modules Supported operating systems The FC3172 2-port 8Gb FC Adapter supports the following operating systems on the x86 compute nodes: Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008, Datacenter x64 Edition Microsoft Windows Server 2008, Enterprise x64 Edition Microsoft Windows Server 2008, Standard x64 Edition Microsoft Windows Server 2008, Web x64 Edition Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 Red Hat Enterprise Linux 5 Server with Xen x64 Edition Red Hat Enterprise Linux 5 Server x64 Edition Red Hat Enterprise Linux 6 Server x64 Edition Red Hat Enterprise Linux 7 SUSE LINUX Enterprise Server 10 for AMD64/EM64T SUSE LINUX Enterprise Server 11 for AMD64/EM64T VMware ESX 4.1 VMware ESXi 4.1 VMware vsphere 5.0 (ESXi) VMware vsphere 5.1 (ESXi) VMware vsphere 5.5 (ESXi) IBM Flex System FC3172 2-port 8Gb FC Adapter 5

The FC3172 2-port 8Gb FC Adapter supports the following operating systems on the Power Systems compute nodes: AIX 5L for POWER Version 5.3 AIX Version 6.1 AIX Version 7.1 IBM i 6.1 IBM i 7.1 IBM Virtual I/O Server Red Hat Enterprise Linux 5 for IBM POWER Red Hat Enterprise Linux 6 for IBM POWER SUSE LINUX Enterprise Server 11 for IBM POWER See IBM ServerProven website for the latest information about the specific versions and service packs that are supported: http://ibm.com/servers/eserver/serverproven/compat/us/ Regulatory compliance The adapter conforms to the following standards: United States FCC 47 CFR Part 15, Subpart B, ANSI C63.4 (2003), Class A United States UL 60950-1, Second Edition IEC/EN 60950-1, Second Edition FCC - Verified to comply with Part 15 of the FCC Rules, Class A Canada ICES-003, issue 4, Class A UL/IEC 60950-1 CSA C22.2 No. 60950-1-03 Japan VCCI, Class A Australia/New Zealand AS/NZS CISPR 22:2006, Class A IEC 60950-1(CB Certificate and CB Test Report) Taiwan BSMI CNS13438, Class A Korea KN22, Class A; KN24 Russia/GOST ME01, IEC-60950-1, GOST R 51318.22-99, GOST R 51318.24-99, GOST R 51317.3.2-2006, GOST R 51317.3.3-99 IEC 60950-1 (CB Certificate and CB Test Report) CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3) CISPR 22, Class A Physical specifications The dimensions and weight of the adapter are as follows: Width: 100 mm (3.9 inches) Depth: 80 mm (3.1 inches) Weight: 13 g (0.3 lb) Shipping dimensions and weight (approximate): Height: 58 mm (2.3 in) Width: 229 mm (9.0 in) Depth: 208 mm (8.2 in) Weight: 0.4 kg (0.89 lb) IBM Flex System FC3172 2-port 8Gb FC Adapter 6

Popular configurations The FC3172 2-port 8Gb FC Adapter can be used in various configurations. The following figure shows the I/O installed in an I/O adapter slot 2 of the x240, which in turn is installed in the chassis. The chassis is connected to an IBM System Storage V7000. The RAID functionality is provided by the external storage system. Figure 4. Example configuration The following table lists the parts that are used in the configuration. Table 5. Components used when connecting the FC3172 2-port 8Gb FC Adapter to external disk storage Part number/ machine type Description Quantity 8737 IBM Flex System x240 Compute Node or other supported server 1 to 14 69Y1938 FC3172 2-port 8Gb FC Adapter 1 per server 8721-A1x IBM Flex System Enterprise Chassis 1 69Y1930 IBM Flex System FC3171 8Gb SAN Switch 1 or 2 44X1964 IBM 8Gb SFP+ SW Optical Transceiver 1 per FC cable 39M5698 IBM 1m LC-LC Fiber Channel Cable 1 for each V7000 connection 2076-124 IBM System Storage V7000 1 This configuration also requires additional V7000 features, such as drives and software licenses. These are not listed in the table. IBM Flex System FC3172 2-port 8Gb FC Adapter 7

Related publications For more information, see the following resources: IBM Flex System FC3171 8Gb SAN Switch and Pass-thru Product Guide http://www.redbooks.ibm.com/abstracts/tips0866.html IBM Flex System FC5022 16Gb SAN Scalable Switch Product Guide http://www.redbooks.ibm.com/abstracts/tips0870.html IBM Flex System Information Center (User's Guides for servers and options) http://publib.boulder.ibm.com/infocenter/flexsys/information IBM Flex System Interoperability Guide http://www.redbooks.ibm.com/fsig IBM Redbooks publication IBM Flex System Products and Technology, SG24-7984 http://www.redbooks.ibm.com/abstracts/sg247984.html IBM Redbooks Product Guides for IBM Flex System servers and options http://www.redbooks.ibm.com/redbooks.nsf/portals/puresystems?open&page=pgbycat IBM Configurator for e-business (e-config) http://ibm.com/services/econfig/ IBM System x and Cluster Solutions configurator (x-config) http://ibm.com/products/hardware/configurator/americas/bhui/asit/ IBM Flex System FC3172 2-port 8Gb FC Adapter 8

Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-ibm product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-ibm Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.ibm may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-ibm products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-ibm products. Questions on the capabilities of non-ibm products should be addressed to the suppliers of those products. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrate programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. Copyright International Business Machines Corporation 2012. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. IBM Flex System FC3172 2-port 8Gb FC Adapter 9

This document was created or updated on October 22, 2014. Send us your comments in one of the following ways: Use the online Contact us review form found at: ibm.com/redbooks Send your comments in an e-mail to: redbooks@us.ibm.com Mail your comments to: IBM Corporation, International Technical Support Organization Dept. HYTD Mail Station P099 2455 South Road Poughkeepsie, NY 12601-5400 U.S.A. This document is available online at http://www.ibm.com/redbooks/abstracts/tips0867.html. Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are marked on their first occurrence in this information with the appropriate symbol ( or ), indicating US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: IBM IBM Flex System Power Systems Redbooks Redbooks (logo) ServerProven System Storage System x The following terms are trademarks of other companies: Microsoft, Windows, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. IBM Flex System FC3172 2-port 8Gb FC Adapter 10