Orbital smart Tunable Downlight

Similar documents
RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

time2 WiFi LED Smart Bulb User Manual

SOLARIMMERSION IV Advanced Installation Manual v1.9

Weathersafe Vision. Installation & Operating Instructions

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

Phoebe LED Spectrum 10W RGB/Tuneable White downlight INSTALLATION AND APP INSTRUCTIONS

Technical Data. Wi-Fi Socket Range Extender. Features: 922WR

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

B60 Domestic Voltage Optimisation Unit. Installation Manual

WIRED REMOTE INSTALLATION GUIDE

INSTALL & SET-UP GUIDE

Quick Installation Guide

Flexoled FTP3HP RGB LED DMX Driver

FCC/CE Certification Information

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

RECTANGULAR LED 3060-L L L-8060

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Installation Instructions

X-3 LED. Owner s Manual ROBOHEAD

LED Gooseneck light FEATURES AND BENEFITS: ORDERING MATRIX: LED GOOSENECK LIGHT:

LIGHT BRICK - 12 X 3W TRI-COLOUR

Please read this safety information carefully and keep this user manual for later reference.

Gobo Projector XP 80W

xbrick Full-Colour 16 3W LED floodlight user manual

MULTI-MONITOR CONTROLLER USER MANUAL

FTP1 Single Channel LED DMX Driver

Smart Touch Thermostat Colour Touchscreen Thermostat

Slimline CW & WW Series

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

TPC25 active crossover. user manual

MX3 BT LED Party Tube

Product and functional description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

NE400 - LED MOTION LIGHT WITH VIDEO CAMERA

Cockpit Main Gateway Ordering Code: CKNOAD1

Blitzer Strobe. User Manual. Order code: EQLED366

PHOS 20/40 downlight OWNER'S MANUAL

Saturn Mini CT (SS9000/SS9007) Product and Driver Installation Guide. Revision: 3.0 Date: Monday, July 10, 2017 Authors: Gareth Sanders, Alan Chow

Technical Manual Sensor / Switch actuator 1/1gang; 2/1gang; 2/2gang

Lucid arena pro LED luminaire

Smartwares. User Manual for C723IP, C724IP, C923IP, C924IP

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

iq DIGITAL PICTURE FRAME iq Digital Picture Frame DPF701SB USER GUIDE

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

DUAL MONO POWER AMPLIFIER INSTRUCTIONS FOR USE

THE SMART WAY TO ANSWER YOUR DOOR USER MANUAL

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

LED SPIDER MOVING HEAD LIGHT

Home Automation Gateway HA102

Product Features. LED Light. LED Indicator light. Camera Lens. Microphone. IR LEDs. PIR Sensor. Reset button. Micro-SD card slot. Speaker.

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

HX1 Bluetooth Stereo Headset

Product and functional description

Quick Start Installation and User Manual

TA18 active subwoofer. user manual

ERT50T Triac Noiseless Digital Room Thermostat for Underfloor Heating Applications

Installation Instructions

DALI Professional Controller-4. Control unit Operating instructions

UP-1-1 Channel Dimmer. User manual. dimmer pack

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Swing-Arm Reading Lamp

CPA 40 Two Channel Amplifier

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

UP-1-1 Channel Dimmer dimmer pack. user manual

FengMi Wemax One Laser Projection TV

RGB Power Batten. User Manual. Order code: EQLED032

Crossfire. User Manual. Order code: EQLED061

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

DMX LED Starcloth Systems

User Guide for Feit Electric App. Set up instructions for Alexa & Google Home.

PF LED Profile. User Manual

ARC ACTIVATED HEADSHIELD

Digital Room Thermostat for Underfloor Heating Applications

U-Bell. Quick Start Guide. Two-way Audio. 180 Field of View. Motion Activated. 1080p Full HD. Night Vision. Wireless Video Doorbell DB1

Standalone Night Sensor

Technical Manual Room temperature controller

ShadowLESS lighting systems for microscopy

DLB1248 single channel EASY-BLE

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

OT EASY 60 II. LED control unit Operating instructions

Mini Digital Multimeter

CX1 Outdoor Color-Changing Wireless Bluetooth Speaker Please fully charge the speaker prior to first use!

FIBARO SINGLE SWITCH

LED SMD FLOODLIGHT with knuckle

Digital Room Thermostat

LED Driver Compact fixed output

LED PAR56 Order Code: P56-151

TourPro RGBAW Stagebar USER MANUAL

MICRON DJ Booth System with Overhead Kit & CW Starcloth

LED Pixel Rail Drive 640 controller. user manual

LED Profile 150W 3200K. User manual. LED spotlight

Slimline LED Floodlight

AW12 IN WALL APPLIANCE MODULE

DS-2 RF DMX dimmer. user manual

Linear Luminaire with LED Series 6012/5

Worldwide Energy and Manufacturing USA, Co., LIMITED Add: RM 1708 C1, NAN FUNG TOWER, 173 DES VOEUX RD CENTRAL, HK. Installation Manual

Transcription:

Commissioning The ceiling surface must be flat and smooth to ensure a good fit. Push the spring clips upwards and fit into the ceiling hole. See Fig 1. Push the unit up until firmly in position, ensuring that no cables are trapped. See Fig 2. Ensure that the product is sitting properly in the hole. Replace fuse or circuit breaker and switch on. Your light is now ready for use. This product is suitable for dimming. Just Dimmable with SaxbySamrt App". Please refer to the SaxbySmart manual for specific operations. 1. 2. Instruction leaflet Orbital smart Tunable Downlight 79305 Fitting/replacing bulbs This product contains non replaceable parts and cannot be serviced. We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. Recycling advice Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. Safety information For your safety, always switch off the supply before cleaning. Iss.1 10/01/2019 WWW.saxbylighting.com Saxby lighting. BH23 3PE

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference. Warning This product is suitable for use in Zone 2 and outside Zones of a bathroom. See diagram. If this unit is being fitted in a room containing a bath or shower, a 30mA RCD must be used, in accordance with IEE regulations. This light fitting is Double Insulated and does not require connection to an Earth circuit. Please read these instructions carefully before commencing any work. This unit must be fitted by a competent and qualified electrician. Install in accordance with IEE Wiring regulations and current Building Regulations. This system operates at Safety Extra Low Voltage, via the supplied LED driver. Never connect the light fittings directly to the mains without using the supplied LED driver. Always disconnect the LED driver from the mains when installing or maintaining this system. Luminaires not suitable for covering with thermally insulating material. To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. This light fitting should be connected to a fused circuit. If replacing an existing fitting, make a careful note of the connections. This fitting must always be fitted to a plasterboard ceiling. This must not be fitted to a plaster and lathe ceiling This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped. This product meets the electrical installation requirements for fire-rated ceiling lamps (BS476 Part 21) and can withstand fire up to 30, 60 and 90 minutes. The fire protection is provided by a glass lens. This has been tested and has passed the relevant standards. Installation Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires. Position the LED Driver next to the mains outlet that the system will connect to. Do not connect at this stage. Cut a 97mm diameter hole using an appropriate tool. Ensure that the void depth is a minimum of 75mm. It is recommended to cut the hole slightly smaller than needed, then file the hole until the recessed unit fits snugly. Wiring Specification Voltage: 240V 50Hz Lamp: 9W LED Module (CCT) 3000K-6000K IP rating: 65 Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the connection block inside the LED driver in the following way: This unit is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property. SUPPLY CLOSED LIGHT FITTING N L Layout Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between the transformer and each light fitting. Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged. The distance between units must be 0.5m minimum. The unit must be located 0.2m away from a joist. This product must be mounted out of arms reach. The luminaire/fitting can be installed with insulation. Driver can be covered with insulation no ventilation required. Check that... Ensure outer cable insulation is clamped inside LED driver as shown here to ensure product is double insulated. SUPPLY NEUTRAL LIVE N L OPEN LIGHT FITTING PRE-FITTED The mains supply cable must have a minimum cross sectional area of 1.0mm². You have correctly identified the wires. The connections are tight. No loose strands have been left out of the connection block.

SAXBYSMART USER MANUAL

STEP 1 Log in to Google Play or the App Store on your mobile phone. Search SaxbySmart and click Download. You will need an active internet connection. Once downloaded, click on the app to open and proceed to log in or register. STEP 3 After clicking register you can choose to set up your account by phone or email. Enter your email address or mobile phone number into the dedicated fields and proceed to accept the service agreement and privacy policy by ticking the box. Click Obtain verification code. A text message or email will be with you shortly to confirm your verification code. IMPORTANT: Make sure you register with the same email you used to set up your Amazon Alexa or Google Assistant devices so you can link these devices to the SaxbySmart app later. STEP 2 STEP 4 Please read carefully through the Privacy Policy. You may click Agree to proceed with set up. Or click Disagree if you wish to cancel registration. Enter the verification code that was sent to you via email or text message in the dedicated field. Please note, the field automatically spaces your code into six easy to read sections. You can also resend the code here if you haven t received it yet. Please allow up to five minutes for your code to be received.

STEP 5 STEP 7 Nearly there. All you need to do now is set a password for registration. Please note that your password needs to be a combination of letters and at least one number and between 6-20 characters long. You may click the eye icon to view your password to verify it is correct before clicking Completed. Enter an easy to remember name for your family/household like Smiths family. You can tick or untick rooms depending on your property. Any rooms to add that are not in the list? Click Add another room to set up as many additional rooms as you wish, e.g. conservatory. STEP 6 STEP 8 Welcome to SaxbySmart. Please click Create family to turn on your smart life. It is now time to add your smart light fittings. Click Add device.

STEP 9 Turn the light on, leave it on for 10 seconds. Turn it off and on repeatedly, three times. When the light starts to blink, click Confirm Light Blinks Rapidly. Please install one light at a time. STEP 11 The app will now connect your fitting. Once the process is 100% completed, the Added successfully page will show your device. You can keep the default product name (e.g. Orbital Smart) or rename the device. Finally, click Completed. STEP 10 Enter your Wi-Fi details and click Confirm. STEP 12 You re good to go and ready to control your fitting through your smartphone. Click White mode to adjust the colour temperature and brightness or click Schedule to set up a day by day planner for your lights. Click the triple dot icon at the top right corner to display extra options, such as pairing your fitting with Amazon Alexa or Google Assistant.