General introduction Part 2, chapter 11

Similar documents
Delomatic 4, DM-4 Land DATA SHEET

MULTI-LINE 2 APPLICATION NOTES

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

APPLICATION NOTES H-coupling

PPM Protection and Power Management DATA SHEET

Option H3 Serial communication Profibus DP

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

M-Logic Internal Logic Controller Description of M-Logic Functional description List of possible selections for logics

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION

TYPE APPROVAL CERTIFICATE

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

PPU Power Management (PPM)

Genset control and protection with safety system

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

AGC 200 Advanced Gen-set Controller DATA SHEET

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

NOT RECOMMENDED FOR NEW DESIGNS

Automatic Gen-set Controller Multi-line D

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Engine & Genset Controls Z, page 1 of 12

paralleling SOLUTIONS

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Installation Manual. Multi Power Controller MPC-1 multi-line D

GC2000 Generator Controller Power Management and Protection

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

Basic Gen-set Controller multi-line F SW version 2.31.X or later

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Comprehensive Modular Genset Controller

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

Si-TEC Xtend CGC ET DATA SHEET. Digital control range for extraction steam turbines. Key features. Models. Description

Comprehensive Modular Genset Controller

Si-TEC Xtend CGC DATA SHEET. Digital control range for steam turbine generators. Key features. Models. Description

Generator Protection Unit, GPU-3 DATA SHEET

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

EMS-GC10 Genset Controller. Modbus Communication Mapping Manual Section 75

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

DATA SHEET Automatic Genset Controller, AGC-3

Generator Protection Unit, GPU-3 DATA SHEET

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

c InteliGen NTC general purpose HIGH-END gen set controller

INSTALLATION INSTRUCTIONS

Features. Application range. Si-TEC Xtend Recip interface. Accumulated data recording of engine running hours, kwatt hours, kvar hours, etc.

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

DATA SHEET Paralleling and Protection Unit, PPU-3

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET

Control Systems Product Overview

Synchronizing Systems

Si-TEC Xtend GSM DATA SHEET. Digital control range for grid parallel/bus tie. Key features. Description

Generator Paralleling Controller, GPC-3 DATA SHEET

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

ALL-IN-ONE Generator & CHP Control System ALL-IN-ONE MOTORTECH GENERATOR & CHP CONTROL SYSTEM

PARAMETER LIST DELOMATIC 4, DM-4 GAS CHP CONTROLLER

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

Power, efficiency and safety on the water That s smart control. Marine and offshore solutions

Power System Network Simulator (PSNsim)

DATA SHEET Automatic Genset Controller, AGC-4

Multiple Generator Automatic Synchronising System

Generator Controller GC-1F

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

QUICK START GUIDE Generator Protection Unit GPU 300

ATL20 ATL30 Automatic transfer switch controller

1. Project Description

GW-7228 J1939/Modbus RTU Slave Gateway

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

Option P1 Event and alarm printer Description of option Functional description Parameter list

Engines & Gen-sets N, page 1 of 6

Manual# Manual. LSU 408 Load Share and Synchronizer Unit

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

SIGMA S6610 PM Module

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

GENSYS CORE. Technical Documentation. Core unit for all-in-one. Genset control and paralleling unit. with integrated plc. Chapter : Overview

Modbus MS Card User manual

Electrical Integration with Smart Communication

DATA SHEET Genset Controller, GC-1F

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Genset Controller Unit Model EMS - GC10. Installation Manual Section

What is new in the easygen3000xt

1SDH001103R0001. Settings conversion from ATS010 to ATS022. User Manual. Technical guide ABB. Power and productivity for a better world TM

CHP GAS MONITOR GDR 1404

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

easygen-series easygen-series Overview Gen-Set Controls for Your Power Generation Systems

easygen- 3100XT/3200XT(-LT) Introduction Presentation

TT /12b INSTALLATION INSTRUCTIONS. Introduction

INSTALLATION INSTRUCTIONS

CHP GAS MONITOR GDR 1404

1. General Information. 2. Application. 3. System configuration

Transcription:

Delomatic 4 DM-4 Land/DM-4 Marine General introduction Part 2, chapter 11 DEIF A/S Page 1 of 8 Document no.: 4189232111C

Table of contents 11. THE DELOMATIC SYSTEM IN GENERAL... 3 GENERAL INTRODUCTION... 4 DEIF A/S Page 2 of 8

11. The Delomatic system in general The documentation for the Delomatic 4 system consists of two separate parts called Part 1 and Part 2. Part 1 is unique for each Delomatic 4 system. This part contains specified data and documentation about the single system. Part 1 refers to a project number which is unique for each project. The project number is a 6-digit number, for example 430000. The project number does always start with 43xxxx. Part 2 is a general description of the Delomatic 4 system. There are no specified data or documentation about the single system in this part. For more specified data and documentation about each project, please see part 1. If there are any differences between the data and documentation in the two parts, it is always the data and documentation in part 1 which is valid. Below is listed some of the different abbreviations that are used in part 1 and part 2. AC Alternating current GOV Governor ACK Acknowledged HC Heavy consumer AOP Additional operator panel IOM Input/output module AVR Automatic voltage regulator Main DGU Master DEIF generator unit BB Busbar MAVR Mechanical AVR CB Circuit breaker MSG Mechanical speed governor CC Closed contact NEL Non essential load CT Current transformer OC Open contact DEIF Danish electronic instrument factory PMS Power management system DG Diesel generator SC Shore connection DGB Diesel generator breaker SCB Shore connection breaker DGU DEIF generator unit SCM Syncronisation, control and measuring module DM-4 Delomatic 4 SG Shaft generator DM-4 LAN Delomatic 4 Local Area Network SGB Shaft generator breaker DU Display unit SWBD Switchboard EAVR Electronic AVR TB Tie breaker ESG Electronic speed governor U-ACK Un-acknowledged GB Generator breaker VT Voltage transformer DEIF A/S Page 3 of 8

General introduction The Delomatic system has been designed for control and protection of generators and can also carry out engine control and protection. The Delomatic system can perform a wide variety of the functions needed on board a ship or in power stations. Power management system (PMS) functions Control of generator set(s) Control of shaft generator(s) Supervision of tie breaker(s) An extensive number of integrated protective functions Measurement of all relevant AC values System logic Serial communication interface The Delomatic system basically consists of a DEIF Generator Unit (called DGU) and a number of Display Units called DU. Basically, there is 1 display unit per DGU, but up to 3 DUs can be connected per DGU. This enables the user interface to be placed separately for each generator (e.g. in the engine room and on the bridge). An Additional Operator Panel (AOP) for plant mode selection, plant status information or local control functions can be used as well. Delomatic-4 PCM 4.1 Delomatic-4 PCM 4.5 The internal communication between the DGUs is based on ARC net (twisted pair). By using a network for communication between the DGUs, a very high transmission rate and a maximum flexibility regarding placement of the DGUs is achieved with PCM 4.1. For redundancy issues, an additional cable connection can be placed between the DGUs to perform a redundant ARC-net connection by use of PCM 4.5. This extra connection secures a continuous communication in case DEIF A/S Page 4 of 8

delomatic 4 of short circuit or open connection in the ordinary communication network. The application software consists of two main software units: Generator control software unit Power management system (PMS) software unit Busbar DM-4 LAN SCB1 B DGB1 B Modbus G G PMS Interface Genset control s oftware DM-4 LAN SHORE DG1 The PMS DGU contains the power management system (PMS) software unit. All DGUs (incl. PMS DGU) in the Delomatic system contain the generator control software unit and a PMS interface. Generator control software unit The generator set control software unit controls and supervises all local operations of the generator set. The received PMS commands may initiate e.g. start and stop of the generator set, but the generator set control software unit carries out the actual control, protection and supervision of the generator set. PMS software unit The PMS software unit controls and supervises all common PMS functions in the Delomatic system according to the functionalism of the selected plant mode, e.g. the SEMI-AUTO or the AUTOMATIC plant modes. Common PMS functions may be functions such as the load-dependent start/stop function and selection of start/stop priority. The PMS interface forms a bi-directional communication link between the PMS software unit and the generator set control software units. The PMS software unit transmits e.g. PMS start/stop commands and selected plant mode via the PMS interface. The generator set control software units transmit signals such as the operational status of the generator sets (e.g. running or standby), relevant measured and calculated values and status of the selected control mode (PMS control or SWBD control) for the generator set. DEIF A/S Page 5 of 8

The programmable Delomatic set points and timers The Delomatic system is controlled according to a number of programmable set-points and timers called the system setup. The operator may programme the set points and timers by means of the Delomatic menu system, which is accessible through the display units or the Delomatic 4 utility software. The Delomatic menu system offers: Access to set-points and timers used for control of the integrated PMS Access to set-points and timers used for local operation of the generator sets Access to set-points and timers used for the supervision and protective functions Read-out of measured and calculated values System selections Alarm handling The above-mentioned data are furthermore accessible via the PCM (Power Control Module) serial communication interface. This enables the Delomatic system to interact directly with other systems or operate as a front-end system. The PCM supports the following serial communication standards: 2 pcs. RS485 standard Modbus RTU as 2-wire (twisted pair) 2 pcs. CANbus ports. Protocol to be defined in the project. DEIF A/S Page 6 of 8

The Display Unit (DU) The DU is a slave unit, which receives information from its corresponding DGU. Measured values and programmed system setups are all stored in the corresponding DGU. DIESEL GEN X Prio. X G G 0.00Hz 0kW 0V 0KVAR SETUP V0 V1 V2 V3 V4 The DU offers: Display and control of the Delomatic menu structure Access to set-points and timers Access to system selections Read-out of measured and calculated values System status Operator alarm-handling interface Display of alarm messages Status indication with LEDs DEIF A/S Page 7 of 8

DEIF Generator Unit (DGU) The DGU is configured with a different number of hardware modules, depending on functions in the Delomatic system. The following hardware modules are available: Power supply and control module with communication RS485 (PCM 4-1 and PCM 4-5) Input/Output Module (IOM 4.1) Synchronising, control and measuring module (incl. genset control) (SCM 4-2) Synchronising, control and measuring module (SCM 4-1) DEIF A/S reserves the right to change any of the above. DEIF A/S Page 8 of 8