ACTpro 1500 Single Door IP Controller

ACCESS CONTROL SYSTEM

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

TDSi MICROgarde type door controllers offer a fully featured door controller with up to 25,000 card memory.

Quick Start Installation Guide

ACR120 Contactless Reader/Writer. 1.0 Introduction. 2.0 Features. 3.0 Supported Card Types. 6.4cm. 9.9cm

U-FLASH Setup Guide U-FLASH.

RFT1000 reader in RACS 5. User Manual

Two Door Controller GEN-045

ACTpro Single Door IP Controller. Operating & Installation Instructions

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

ImproX IXP20 Controller INSTALLATION MANUAL

Click Save to return to the main Setup screen.

EL-ST100 KEYPAD CONTROLLER

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

UC-2000 Installation Manual Unicorn Computers Technology Limited

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

ACR120 Technical Specifications Version 4.00

Technical Datasheet. XMP-TMC28xx-xxx

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

ABOUT CIVINTEC PLATFORM PRODUCT RANGE CIVINTEC GLOBAL. World Leading OEM/ODM Designer & Manufacturer

CPS kVA TRIFASE EN50171

RXTH DUAL ROOM SENSOR / SWITCH

USER MANUAL. Longo programmable controller LPC-2.CR1 Card Reader module. Version 5

ACR128U Dual- Interface Reader

_ Access control SISTEMAS DE SEGURIDAD

Every now and again, things come along that completely transform our

USER MANUAL. Longo programmable controller LPC-2.CH1M Card Holder module. Version 3

REV6 Multi Sector MIFARE Reader/Writer Data Sheet

It features compatibility for most controllers on the market, and it has unique multi-format interface.

iloq S10 Online Configuration Guide

installation quick guide integrated access control & environmental monitoring

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

ACX Series. Access Controller for Ethernet

SALLIS. Installation & Maintenance Guide. Issue: /07/03. Author: Jon Mendizabal

ACR120 Contactless Reader/Writer

TAC I/NETTM 1284, 1280, Security Control Unit

CV5XX0A-X-XX Access Control Door Reader supports Mifare DESFire EV1 and Mifare Plus The family members are: Security Features for Mifare DESFire

Aperio Programming Application Manual

ACR122S NFC Reader. Datenblatt / Specifications. Technical Specifications

TL100C Features: Real-time 1-touch data export 3rd party hosted & non-hosted applications

Pegasus Equipments Export Limited. Local Contact:

MCT82M-IO-CH Operating Manual

Technical Instructions MT15000/2 MT15000/2-M

Technical Data sheet

PROCONTROL Proxer7. Datasheet. RFID Proximity card reader. Procontrol Proxer7. November, PROCONTROL ELECTRONICS LTD

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Digital Keypad Introduction

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

USER MANUAL. Longo programmable controller LPC-2.CA1M Card Reader module. Version 2

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Network Video Recorder Quick Operation Guide

Specifications: Features:

GV-Card Reader. User s Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

ACTPRO ACCESS CONTROL. Specification Guide

Amano Nexus Lite Controller INSTALLATION MANUAL

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

FACIAL RECOGNITION TERMINAL SYSTEM

User Manual. cmt-svr Startup Guide

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

NetAXS-123: One door, compact (plastic) enclosure. NetAXS-123: One door, standard (metal) enclosure with tamper switch and terminal block

RXTP ROOM TEMPERATURE

mark150s mark150/485s DDC controllers Summary

User Manual. PCKeypad Wireless Keypad

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Access Terminal IF-800

Operation manual For NG BIOSINGLE Version 1.1

ACR880 GPRS Portable Smart Card Terminal

Multi Card Technology

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

V-9939C MICROPHONE ADAPTER

BioEnable Iris Recognition Solutions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

AR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting. Siemens AB. Version 5.0 A Security Products

Operating instructions

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

W3-H Waterproof Keypad/Reader/Controller

Technical Manual - Part 2

NS1 Connection Unit Guide

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

CS1716i. 1-Local/Remote Share Access 16-Port PS/2-USB VGA KVM over IP Switch

Please take serious note of the following warnings:

Gas Controller System DGC-06

MaCaPS International Ltd

ACR120 Technical Specifications version 3.1 January 2007

Mifare ID Reader. with selectable outputs

TM221CE24R controller M IO relay Ethernet

Rugged Industrial Media Converter

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

REX F-0-9 Standalone or Access Controller

Transcription:

General is the entry level system of, designed to meet the demands on access control systems to be installed and managed easily, with the maximum possible flexibility on tags (cards) and readers to use, also to be capable of controlling a wide variety of electronically controllable access blocking devices. To make it really simple to manage, there is no need to install software on PCs as it has a built-in WEB server manageable via WEB. Capabilities SC-1000 Webstar is capable of controlling up to 16 access points with 2 readers of each, 32 access points equipped with one reader of each, and a combination in between. To build-up larger access control systems, offers its SIS systems, where there is no limit for the size of the systems. All hardware components of can be used when upgrading the system for SiS. This concept opens the possibility for a low cost upgrading. Applicable ID tag types compatible readers Practically, all commonly available ID tag readers can be managed by the system. e.g.: MIFARE, HID, Indala, EM, UHF, Hyper-X, etc. Applicable electronically controllable access blocking devices e.g.: magnetic strikes, turnstiles, speed gates, barriers, etc. Operation The access control modules communicate the events immediately to the controller on the CAN bus. Events are processed by the controller and it responds on them according to the rules stored in it. After processing the event, the controller sends commands to the modules via the CAN bus requesting them for the adequate reaction. Continuous connections between the controller and the modules are required for the correct operation. Time-stamps, provided by the controller, are added to the events and they also stored in its memory for further processing, creating reports. Setup is done via the WEB server utilizing a standard internet browser. 2

-the ideal solution to create an entry-level access control system Advantages when installing: Quick and simple installation Just follow the wiring instructions when installing the system No IT knowledge required No software installation required as the system is WEB-server based with high level services Simple configuring, automatic module recognition Following the hardware installation, it provides the possibility of full operation Loading or saving master data can also be made in an Excel file format Advantages in everyday use: WEB-browser only required for the system management and supervision (Explorer, Firefox, Opera, etc) Bilingual operator platform (English Hungarian as default) Built-in translator for to make the operator platform speak in different languages Language setting options for the operator platform by operators -2 languages simultaneously 4 levels of system management can be set with password protection Capable of managing 5 different FCs (facility code) to manage common access points of office buildings with different tenants Optional access right distribution by access points with different time-zones 16 different time-zones with 90 time slots Setting possibilities for to manages special calendar days with altering rules for access 3 different ways for to enter ID cards into the system: by reading them, defining an interval or importing them from an Excel file Granting and deleting access rights can be made individually, by user groups or entirely Copy-paste for to create simple access profiles Built-in Quick Guide and User Manuel with instant access Effective service support with built-in self-checking diagnostics modules Additional high level services: The system manages 500 cards (tags) as a default In full configurations, it can take 16 access points with bidirectional identification or 32 access points with single directional identification or any combination in between. It has an events memory capable of storing 100 000 events at a time Remote management according to entitlement levels Various event tracking functions (by time-intervals, users, access-points, event types, etc) On-line event monitoring Report generation, exporting reports Map management with icons representing the type and status of the access points. 3

System charts Adding access control modules The limits of the is: 1x SC-1000-01 group controller 16x active SC-1000-02 access control,module 4

Packages of components SC-1000 Basic Kit + 7Ah battery SC-1000-D large metal box SC-1000-01 group controller SC-1000-02 x2 access control module PWS-12-20 12V/2A linear power supply Akku-7 12V 7Ah battery SC-1000-02-D middle-size sheet metal box SC-1000-D middle-size metal box SC-1000-01 group controller SC-1000-02 x1 access control module PWS-12-20 12V/2A linear power supply Akku-7 12V 7Ah battery SC-1000-02 access control module in a sheet metal box SC-1000-D small-size metal box SC-1000-02 x1 access control module PWS-12 Power supplies in a sheet metal box PWS-12-10 12V 1A PWS-12-20 12V 2 A Akku-7 7Ah battery 5

WEB Management t is designed to have an on board WEB server to run the application software. It provides the required software tools and services to set up and operate the system via an internet browser. Operator platform (samples) Assigning access authorisations application software services have an elegant graphics platform. When in operation, can practically be accessed from any kind of IT networks. To do so, you need the appropriate network settings and access path. Interconnection between the and the PC can be made by connecting them to the same IT network or by using an Ethernet cross cable. Setting up time zones can be started from any Internet browser. (Flash Player is required.) Type in the followings into the search line of your Internet browser: http://ip address For the first occasion: http://10.100.100.1 Communications language of the WEB server has memory space for two languages to choose from for its operator platform. One of them is English, as standard, and the other one is optional. A language manager to translate the operator platform to different languages is also available for (translator software, users guide and the assembly of phrase definitions applied). With the help of these, the operator platform can be prepared for to take a new language beside the English. For to help the translation, each window of the operator platform has a unique identifier displayed at the upper left-hand corner. Events report Firmware upgrade Additional services of the WEB server Following chart provides a summary of the WEB server services available by user authentications (guard, administrator, supervisor, and installer). 6

WEB Management - Menu System User Authorisations Guard Administrator Supervisor Installer Reports x x x x Event monitor x x x x Event report - x x x User - x x x Operations x x x x Terminal status - - x x Grid view - - x x Map view x x x x Change password x x x x Logout - x x x Editor - x x x System manager - - x x Module - - - x Terminal - - - x Time zone - x x x FC - - - x Identifier (ID) - x x x Authorisation - x x x Map - - - x Backup and restore - x x x Create backup - x x x Restoring - - x x System - - x x Restart - - x x Date and time settings - - x x IP settings - - - x Module status - x x x Module connections test - - - x Configurations file - x x x Preview - - x x Restore factory default - - - x Restore last correct configurations - - x x Terminal configurations - x x x ID database - - - x IDs in memory - - - x Delete - - - x Events log status - - x x Options - - - x Firmware - - x x File operations - - - x Firmware upgrade - - - x Log files - - - x Configurations error log - - - x Test log - - - x 7

SC-1000-01 Group Controller SC-1000-01 group controller operates the access control modules and logs the events. CAN bus is used for the communications between the controller and the access control modules. SC-1000-01 has an Ethernet connecting capability for to make it accessible from LAN. For, a built-in WEB server is also added with on boar application software to setup the access control systemand analyse the events. Technical specifications Type SC-1000-01 Group Controller Metal box Box A Box B Installation environment Metal box Indoor use Sheet metal box, powder coated finish Outside dimensions 335 x 455 x 95 mm 240 x 380 x 95 mm Weight Power Current requirement Maximum current requirements Accuracy Maximum number of events stored Maximum number of IDs Maximum number of connecting modules Number of tag readers Number of inputs Number of outputs Communications lines Tamper protection Operating temperature Relative humidity 5,9kg (without battery) 12 V DC 45 ma 135 ma (without USB device) 1 sec 100000 20000 (100000 with limitations) 32 4,2kg (with battery) Applies for the modules only (2x / module tipycal) 2 + inputs available on the modules 2x relay dry contacts + outputs on the modules RJ45 Ethernet 100Mbit CAN 62,5 kbps USB (Full speed) RS-485, RS-232 Tamper switch + loop -5 +50C º Storage temperature -20 +60C º 10% 95% non-condensing Main features 400 MHz processor LINUX operating system Watch dog Built-in WEB server Tamper sensor Ethernet port 2x CAN bus RS-485 bus 2x serial port 6x input 2x relay outputs Power supply supervision 2x USB port Indications of the controller, default settings TYPE LED displays: SC-1000-01 LD1 / POWER: Red power LED1 / Status: Green operating status of the system LR2 / TX CAN bus communications LG3 / RX Jumpers: JP1 / Battery: Connecting back-up battery JP3 / CAN1 Connecting CAN TERMINATOR: bus terminating JP5 / MFG DEFAULT: Push button: RESET: resistor Operating mode Restarting the controller 8

SC-1000-02 Access Control Module SC-1000-02 access control module can manage one two way or two one way access points. Practically all kinds of available tag (card) readers and electronically controllable access blocking devices (magnetic strikes, turnstiles, speed-gats, barriers, e.t.c.) can be connected to it. Technical specifications Type SC-1000-02 Access Control Module Installation / operation Power connections Power Current requirement Tag readers Inputs Outputs Communications Operating temperature Relative humidity Storage temperature It can be installed separately but only operates under the control of SC-1000-01. Independent module and device connections 12V DC 58mA (without tag reader) 2x ABA track2 or Wiegand 4x contacts NC or NO 2x relay dry contact CAN 62,5kbps -5 +50Cº 10% 95% non-condensing -20 +60Cº Access control module indications, default settings Type SC-1000-02 Access Control Module LED displays: LD1 / POWER: Red - power LD2 / DIAG: Amber, Continuously on: OK operating status of the module: Turns On & OFF in every second: Connections is OK, not configured Short flash in every 5 seconds: there is no CAN connection with the controller LD3 / CAN RX: CAN bus communications LD4 / CAN TX: Jumpers: JP1 / CAN TERMINATOR: Push button: Connecting CAN bus terminating resistor at the end of the CAN bus RES / RESET: Module restart (HW reset) Main features CAN bus 2x tag reader interface 4x dual-state input 2x relay output Tamper sensing RS-232 interface (not used for WebStar version). Manageable tag readers MIFARE HID INDALA EM (ASK) UHF readers HYPER-X etc. ABA track2 or Wiegand interface types. Facility code (FC) or ID only management or the combination of them. Manageable access blocking devices All kinds of magnetic strikes turnstiles speed-gates barriers etc. Note: There is a Wiring Instruction guide is available for the system to provide help for connecting the various readers and access blocking devices. 9

MFN/MFS-300 series of proximity readers MFN-310/311 readers are capable of reading the unique ID (UID) of Mifare Plus tags. These readers can recognise any Mifare Plus 1K, 4K tags. MFS-310/311 readers can also read a sector of Mifare Plus tags. Security level of sector readers is much higher as assess to sector data only available for readers with the matching access key to make illegal copying practically impossible. Available models: TYPE DESCRIPTION Readers MFN-310 MFN-311 MFS-310 MFS-311 R/W devices MIFARE Plus UID reader dark grey MIFARE Plus UID reader beige MIFARE Plus UID + sector reader dark grey MIFARE Plus UID + sector reader beige Call for availability Technical specifications: TYPE MFN-310/311 MFS-310/311 Description: RFID reader Read range: Maximum 5cm* Case: ABS Installation environment: Indoor (IP 44) / Outdoor (IP 64) Finish: MFR, MFS-310 dark grey MFR, MFS-311 beige Dimensions (HxWxD): 80x80x26mm Weight: 72g Visual indication: Multicolour LED Audio indication: Single-tone buzzer Power: 7-14VDC Maximum consumption: 100mA @ 12VDC Transmitting frequency: 13,56Mhz Data format: ABA track 2 Wiegand26, 34, 40 Serial Recognised proximity tag types: MIFARE Classic 1k MIFARE Classik 4k Operating temperature: -25...+65 C Data read: MFN - Serial number UID MFS- Sector contents with Seawing coding Tamper signal: Separate NC contact or transmitted via communications line *with ISO card in a noise-free environment All devices use cryptographic communications between the reader and the tag/card via ABA/Wiegand or serial interface. Cryptographic communications between the controller and the reader is optional and can only be applied for devices with serial interface. For high security systems, they offer tamper protection and continuous presence monitoring as an option. The readers can be installed on flat wall surface but also prepared to be installed on Ø60 electrical wall boxes too. Recognised and managed tag (card) types MIFARE Plus 1K, 4K Note: Various models of these devices can recognise MifarePlus S/X, DESFire EV1 tags and cards, and in addition, some of the models can even write on them. Main features High security Independent applications on a single tag (card) body Wall-mounting & desktop design Tamper protection 10

MSW-400 series proximity readers SW-MP-400 is a series of RFID readers and read/write devices providing perfect solution for applications requiring extremely high security RFID technology. All devices comply with the provisions of 13,56 MHz, ISO/IEC 14 443A-4 standard. Protection of data stored on the cards is on the highest technical level currently known. MIFARE Plus and DESFire EV1 readers and cards are protected against illegal access or modification attempts. Available models: TYPE DESCRIPTION Readers SW-MP-400 SW-MP-400 DESFire SW-MP-400 Classic SW-MP-400 UID R/W devices SW-MP-400 RW Mifare Plus X/S reader DESFire reader Mifare Classic sector reader 14443 A unique ID reader (reads unique ID of Mifare Plus, Mifare Classic, DESFire tags) Mifare Plus X/S R/W device with RS-232 interface SW-MP-400 DESFire RW DESFire R/W device with RS-232 interface SW-MP-400 Classic RW Mifare Classic R/W device with RS-232 interface Technical specifications: TYPE DESCRIPTION Description: RFID reader RFID read/write device Read range: Maximum 5cm* Case: ABS Installation environment: Indoor (IP 44) / Outdoor (IP 64) Finish: black Dimensions (LxWxD): 120x80x25mm Weight: 200g Visual indication: Four-colour visual indication Audio indication: Single-tone buzzer Power: 7-14VDC Maximum consumption: 150mA @ 12VDC Transmitting frequency: 13,56Mhz Data format: ABA track 2 / Wiegand or RS232 Recognised proximity MIFARE Plus S/X, DesFire EV1 tag type: Operating temperature: -10...+40 C Tamper sensor: REED-relay sensor Tamper signal: Separate NC contact or transmitted via communications line *with ISO card in a noise-free environment Recognised and managed tag (card) types Main features MIFARE Classic / Ultralight MIFARE Plus X DESfire EV1 NFC compatibility High security Independent applications on a single tag (card) body NFC support Wall-mounting & desktop design Tamper protection 11

Main features Same construction Safety toroidal transformer Analogue output voltage stabilization Output current limit 12V & 24V accumulator compatibility Mains failure & over discharging battery indications Overload & short-circuit protection Available models The PWS family of power supplies has four members of different output current and voltages. PSW-12-10 12V 1A linear power supply PSW-12-20 12V 2A linear power supply PSW-24-20 24V 2A linear power supply Specifications Type: PWS12-1A PWS12-2A PWS24-2A MEEI* certificate: D0293E039 D0294E039 D0292E039 Input Mains input: 230 V ±10% 50 Hz single-phase Rated current requirements: 150 ma 250 ma 400 ma Mains transformers: TL-30-1 230/16V TL-50-2 230/16V TL-80-1 230/27V Mains connections: Bolt fixing connectors Built-in thermostatic switch, MEEI licence No.: CM2594M025 Output DC output voltages: 13,8 V 13,8 V 27,6 V Output voltages accuracy: +2 5 % Output voltages when recharging battery: 11,6-13,8 V 23,2-27,6 V Output current: 1 A 2 A 1,8 A Current limit 1,3 A 2,3 A 2,2 A Recommended sealed 12V / 7,2 Ah 12 V / 7,2 Ah 2x12 V / 7,2 Ah rechargeable batteries: Output connectors: Bolt fixing connectors Protection Shock protection: Grounding, shock protection class No:1 (for built-in use only) Overload protection: Switch-off circuit for under 12V output voltages. under 24V Battery protection: Fuse protection for inverted polarity & overloading. Over discharging protection. Fault indications: 2 opto-coupling outputs, LED display for mains failure & over discharging battery Tamper protection: Tamper switch Environment Operating temperature: -10 C +35 C Mechanical construction Case: Metal case Size: 200 x 100 x 70 mm Weight: 0,8 kg 1 kg 1,2 kg 12