RТTH DUAL ROOM SWITCH

Similar documents
RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

RXTP ROOM TEMPERATURE

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Operating instructions. Speed monitor D / / 2014

Priva Blue ID Relay output module DOR4/DOR8

Operating instructions. Switching amplifier DN0210 DN / / 2015

DOR6. Components All functions and indications are on the front of the module. Characteristics

Blue ID Power injection module PI60

Priva Blue ID Digital input module DI4/DI8/DI16

Room Temperature Controller

InBin-P Pressure switches from 5 Pa Pa

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

PSBOC PSBOC 27,6V/5,5A/OC

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Electrical Actuators

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Room unit with PPS2 interface

Instruction Manual. T3110 T3110L T3110Ex

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

Installation manual CF8-W-Disp-AL

Priva Blue ID Analogue output module with manual override AO2m/AO4m

CMSA-100 Manual. Cinema Media Server Automation

Electromotoric actuators

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

MC 11 EB-2 Power supply cabinet with external bus, AC version

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Electrical Actuators

Operating instructions. Standstill monitor A / / 2011

7032 Digital-Analog Multimeter

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Installation manual for for Schleifenbauer DPM3

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from


Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Blue ID Communication module RS485 SC44

Room Temperature Controller

OPERATING INSTRUCTIONS

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Priva Blue ID Communication module RS485 SC44

1. Safety Precautions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

GENERAL SAFETY GUIDELINES

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Rhino PSM Power Supplies. Operating Instructions

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Heating Circuit Controller

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

OZONE SWITCH Model OS-6. OS-6 Features

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

External level devices for conductive point level switch

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Heating Circuit Controller

Electrical Actuators

SMART-e Document Rev1

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Priva Blue ID C-Line Mix input/output module MX34

LED-Illumination with Control Unit Ident.-No

Analog Input/Output Modules

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

BA/BS4S Temperature Sensor Installation & Operating Instructions

Ultra Slim Relays 24

Operating Instructions

Overview of types. Technical data

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

V /06/ Velleman nv

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

COMPACT eco -DIN Document Rev1

Phase comparator. User manual Document version: 02i00 Update:

Push-Pull and E-Stop Switches. Datasheet

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Transcription:

DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions

Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS MOUNTING & OPERATING INSTRUCTIONS IN STEPS VERIFICATION OF INSTALLATION INSTRUCTIONS 7 TRANSPORT AND STOCK KEEPING INFORMATION 7 WARRANTY INFORMATION AND RESTRICTIONS 7 MAINTENANCE 7 MIW--EN-000-7 / / 0 www.sentera.eu - 7

SAFETY AND PRECAUTIONS Read all information, the datasheet, mounting instructions and wiring scheme before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications to the product are not permitted. The product must not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Chemical vapours with high concentration in combination with long exposure times can affect the product performance. Make sure the work environment is as dry as possible; check for condensation spots. All installations shall comply with the local health and safety regulations and local electrical codes. This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is life. Always disconnect the power source before connecting the power cables, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use wires with appropriate size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and disposed in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW--EN-000-7 / / 0 www.sentera.eu - 7

PRODUCT DESCRIPTION The RTTH is a dual room switch which measures temperature and relative humidity. This unit has two relay outputs and multiple measuring ranges; one for each measuring unit. ARTICLE CODES Code Supply Connection RTTHG VAC ± 0 % - wire 8 VDC F 8 VDC - wire INTENDED AREA OF USE Monitoring and maintaining temperature and relative humidity in HVAC applications For indoor use only TECHNICAL DATA STANDARDS relay outputs: C/O (0 VAC / A) Power consumption: no load: max. 0 ma full load: max. 80 ma Selectable temperature ranges: 0 0 / 0 0 / 0 0 / 0 0 C Selectable rel. humidity ranges: 0 90 % / 0 60 % / 0 80 % / 0 00 % rh switching points: selectable by trimmers Fixed temperature hysteresis: C Fixed rel. humidity hysteresis: % rh Enclosure: rear lid: plastic ABS, black (RAL900) front cover: ASA, ivory (RAL900) Protection standard: IP0 (according to EN 609) Operating ambient conditions: temperature: 0 0 C rel. humidity: < 00 % rh (non-condensing) Storage temperature: - 0 C Low Voltage Directive 006/9/EC EMC Directive 00/08/EC: EN 66 WEEE Directive 0/9/EU RoHs Directive 0/6/EU MIW--EN-000-7 / / 0 www.sentera.eu - 7

OPERATIONAL DIAGRAMS Relay output Relay output rel on rel on rel off 0 SP-hyst SP 0 T, [ C] rel off 0 SP-hyst SP 00 rh, [%] WIRING AND CONNECTIONS Vin Positive DC voltage / AC ~ GND Ground / AC ~ NO Normally open contact COM Common contact NC Normally closed contact NO Normally open contact COM Common contact NC Normally closed contact Connections Cable cross section: max., mm MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the RTTH dual room switch, read carefully Safety and Precautions. Choose a smooth surface for an installation location (a wall, panel and etc.). Follow these steps:. Open the white cover by releasing the locking plates on both sides of the cover and remove it. (See Fig. Locking plates release.). Insert the cables through the cable opening of the enclosure rear lid. (See Fig. Mounting dimensions.). Fix the unit to the wall / panel taking into account that the unit has to be installed at a minimum height of, m and the air flow has to pass free. Mind the correct mounting position and unit dimensions. See Fig. and Fig.. Fig. Locking plates release Fig. Mounting dimensions Fig. Mounting position Acceptable Not acceptable x Ø 6 9,8 7, 0,6 0, 70, 9,8 0, Keep, m. minimum distance from the floor MIW--EN-000-7 / / 0 www.sentera.eu - 7

. Do the wiring according to the wiring diagram (see Fig. ) using the legend information from section Wiring and connections. Fig. Wiring diagram Relay contacts Normally closed Common Normally open Relay contacts Normally open Common Normally closed Power supply VAC ± 0% / 8 VDC. Adjust the settings:. To select a temperature range, use jumper JP. To select the relative humidity range, use jumper JP (see Fig. and the enclosed information). Fig. Sensor range selection jumpers Temperature Relative humidity 0 0 C 0 90 % rh 0 0 C 0 60 % rh 0 0 C 0 80 % rh 0 0 C 0 00 % rh JP JP JP JP JP JP JP JP. To select the temperature setpoint for relay switching, use trimmer VR. To select the relative humidity setpoint for relay switching, use trimmer VR (Fig. 6). Fig. 6 Setpoint trimmers Temperature Relative humidity 6. Close the enclosure and fix the cover. 7. Switch on the power supply. ATTENTION Do not exceed the maximum power supply rating! Measure before installation! Unregulated VAC supply units provide higher nominal output voltage and activate the integrated fuse protection. ATTENTION If a G-type article is using the same AC power supply source (transformer) as F-type article, a SHORT CIRCUIT may result when the power supply and analogue signal terminals are connected to the same common ground! In this case always connect different article types to separate AC transformers or use the same article version. MIW--EN-000-7 / / 0 www.sentera.eu 6-7

VERIFICATION OF INSTALLATION INSTRUCTIONS Check the status of the blue ON/OFF LED after you switch on the power supply. (See Fig. 7 Operating indication.) The ON/OFF LED should blink during the initialization period (0 s) at equal intervals of s for s. Then it should give out continuous blue light. If this is not the case, check the connections again. If the ON/OFF LED blinks rapidly: it is possible that: you use improper power supply. Check it. the communication with the sensor module is not detected. If it is lost, contact authorised technical support or your sales representative. Fig. 7 Operating indication TRANSPORT AND STOCK KEEPING INFORMATION Avoid shocks and extreme conditions; stock in original packing. WARRANTY INFORMATION AND RESTRICTIONS MAINTENANCE Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. In normal conditions this product is maintenance-free. If soiled, clean with a dry or dampish cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW--EN-000-7 / / 0 www.sentera.eu 7-7