Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

Similar documents
Complimentary Reference Material

Appendix 1 to the R&Mfreenet Warranty Program

Certification for 10G copper cabling

Field-testing procedure. LANmark-6

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Series. WireXpert Key Features. Easy to use and Ruggedized design. Fast and simple for highest productivity

Qualified Partner Programme QPP. Warranty Felice Guarna

PRODUCT CATALOG. Certification, qualification, verification & troubleshooting of network infrastructure from copper up to 2,500MHz to fiber.

LANmark-6 10G LANmark-6 A

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Copper Cabling Standards

Introduction. Standards

History of Standards

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

Wire pert. Cable Certifier. 1st CAT. e C. Cable Tester of Choice

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

The High Cost of a Low-Cost Cable Certification Tester

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

Release Notes. WireXpert / export. Version 7.3 Build 854

DATWYLER SYSTEM WARRANTY

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

New Methods for Integrated Cross-layer Network Health Testing November 2008

Copper Certification Testing Best Practices Pocket Guide

User Manual Fiber Certification Testing

DTX CableAnalyzerTM Accessories Guide

The Impact of Internet of Things on Cable Certification

Wire pert. 1st CAT8 Cable Certifier. Ethernet CABLE CERTIFIER

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

Datasheet: DSX CableAnalyzer Series

Psiber Data. WireXpert. User Manual

EtherScope Series II Network Assistant

T-BERD /MTS-4000 Platform Multiple Services Test Platform

White Paper: Audio / Video (AV) Cabling Considerations

Standards Update. by Paul Kish NORDX/CDT

Application Note: Mode Conversion Testing Prevents Your Network from Hanging in the Balance

MORE ETHERNET ON THE HORIZON WHO NEEDS 2.5G AND 5G ETHERNET? Krzysztof Ojdana, Product Manager WHITE PAPER. Molex Connected Enterprise Solutions

HANDBOOK OF CABLE TESTING

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Trends in Data Centre

Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

Advanced Test Equipment Rentals ATEC (2832)

Optical Certifier I. Tier-1 Fibre Certifier for Multimode and Single-mode Fibre Cabling. Proof of Performance

Telegärtner Point of View

The Impact of Internet of Things (IoT) on Cable Certification

The AMP NETCONNECT Category 6 Cabling System

The advantages of the 6-connector channel

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

User Manual Copper Certification Testing

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

Training Offer. Catalogue

INTERNATIONAL STANDARD

The AMP NETCONNECT Category 6 Cabling System

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

Datasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth.

ORTRONICS SNAP CLARITY TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION. designed to be better.

NGBASE-T Cabling Requirements

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

FTTE Revisited for New Technologies

OptiFiber Certifying OTDR Accessories Guide. See how Fluke Networks options and accessories can enhance your investment.

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

E-DAT C6A. The compact connection system of course with Cat.6A

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS

SignalTEK II. idealindustries.com

NaviTEK II. Save money through using a single multifunction device for testing copper and fibre networks

Softing PROFINET Diagnostic Tools

WireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools

PARKING. JDSU Solutions for Enterprise Structured Cabling

ARP992/ ARP992-B User Reference Manual

25-Year System Warranty. Terms and Conditions. NetworkSciences

Provided by

HUBER+SUHNER DCCT Training

Application Note. Data Center Standards and Layouts

Getting Started Guide

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

1 of 5 12/31/2008 8:41 AM

Datasheet: DSX-5000 CableAnalyzer

CERTIFICATION PLUS SM

Get ready to overachieve.

40G BASE-T Cabling Infrastructure. Allan Nielsen Standards Manager

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Testing and Measurement Technology. Handbook of Cable Testing. Fault Analysis Documentation and Reporting. h ps://itnetworks.softing.

Tel: AC Power for Business-Critical Continuity TM

Increase Network Reliability and Reduce Costs with Cabling Management Software and Services Designed Especially for SYSTIMAX Installations

THE NEW OPTICAL FIBRE CATEGORIES What do they promise?

DTX-PCxxS. Users Manual. Patch Cord Test Adapters

How to cable n Wireless Access Points

Copper USER MANUAL.

Fiber Backbone Cabling in Buildings

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

Viavi MTS/T-BERD TB6000A V2 Mainframe & BERT Module Software Update Instructions

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

Uniprise Structured Cabling Solutions Guide

Transcription:

Psiber Data WireXpert

Agenda Psiber Data WireXpert Introduction Company Presentation Why Cable Certification? Universal Structured Cabling or The Network Standards The WireXpert Page 2

Psiber Data Company Presentation

Psiber Data Worldwide America EMEA APAC London Munich San Diego Boston Paris Milano Singapore Region Office (R&D, Sales, Service) Sales Office

Company Mission Design & market world class communication test products for enterprise networks covering all 7 network layers (ISO model). Sell through balanced channels, providing technical expertise and achieving optimal market coverage Seite 5

Product Segments 7. Application 6. Presentation 5. Session Application and Protocol Analysis 4. Transport 3. Network 2. Data Link 1. Physical Handheld Network Tester Copper Fibre WLAN Topology

Why Cable Certification?

Future-Safety Only certified cabling systems gives futuresafety that todays and future network applications will work on today installed cabling systems! Class Frequency Network Application Class D 100 MHz 100Base-TX, TR 100Mb/s, 100Base-T, TR 16 Mb/s, ATM155 Mb/s, FW 100Mb/s Class E 250 MHz ATM LAN 1,2Gb/s, 10GBase-T/50m Class E A 500 MHz 10GBase-T/100m Class F 600 MHz FC1000-TP, 10GBase-T Class F A 1000 MHz?40 Gb/s? Class? 1200 / 1600 MHz?40 Gb/s?

Warranties / Performance Warranties Many cabling vendors require a test report from a standard based cable certifier to apply their system warranty to a specific installation. Only a full certification of an installation can ensure that workmanship is done correct. Cheap Cabling With many manufacturers claiming their cabling system to be Class E A, only a full certification ensures that the installed cabling meets all standard requirements. Storage of certification data proves future possibilities of cabling While current standards only define cabling up to Class E A for 10G, captured data may prove that cabling is certified for future technologies such as 40G. Page 9

Universal Structured Cabling or The Network

Principle of Structured Cabling Universal Structured Cabling This principle is described in all standards: Campus Cabling Connects the buildings with the Campus Distributor (CD) - most only fiber connections Backbone Cabling Connects the floors with the building distributor (BD) fiber and copper connections Horizontal Cabling Connects the workplaces with the Floor Distributor (FD) most copper and sometimes fiber connections Page 11

Cabling Standards ISO 11801 / TIA 568 / EN 50173

What Standards do we have? ISO/IEC 11801 Europe USA IEEE 802.3 EN50173 TIA/EIA 568 C Standards for passive cabling Standards for active transmission systems Page 13

Cabling Standards 100 MHz 250 MHz 500 MHz 600 MHz 1000 MHz USA TIA/EIA 568-C Cat. 5e TIA/EIA 568-C Cat.6 TIA/EIA 568-C Cat.6A International ISO/IEC11801 Edition 2.1 Class D 2009 ISO/IEC11801 Edition 2.1 Class E 2009 ISO/IEC11801 Edition 2.1 Class E A 2009 ISO/IEC11801 Edition 2.1 Class F 2009 ISO/IEC11801 Edition 2.1 Class F A 2009 Europe CENELEC EN50173-1 Class D 2010 CENELEC EN50173-1 Class E 2010 CENELEC EN50173-1 Class E A 2010 CENELEC EN 50173-1 Class F 2010 CENELEC EN 50173-1 Class F A 2010 Page 14

What is standardised? Components Transmission Links Page 15

and the Cable Certifier! DSP-100 DSP -2000 DSP- 4000 DSP- 4100 DSP- 4300 DTX-1200 DTX 1800 PentaScanner PentaScanner + OmniScanner OmniScanner 2 OmniScanner LT Lantek Pro LT8100 Lantek Pro XL LT8155 LT8600 Lantek 6 Lantek 6A Lantek II 350 Lantek II 500 Lantek 7 Lantek 7G Lantek II 1000 WireScope 155 WireScope 350 WireScope Pro Cat. 5/5e Class D Cat. 6 Class E Cat. 6A Class EA 10G Ethernet Class FA 1200 MHz 40G Ethernet PAM 32/DSQ 512 40G Ethernet PAM 16/DSQ 128

Psiber Data WireXpert

New Measurement Engine Due to new developments in semiconductors new chips that became available in the last 2-3 years State of the art and patent pending design High accurate 4 port vector analyser platform Driven by high density FPGA to deliver real time high accuracy Leap frogging legacy testers by overcoming frequency limitation of older designs Page 18

Comparison Graphs 70 WireXpert vs Networkanalyzer 60 50 40 30 RL_36 RL_green 20 10 0 0 200000 400000 600000 800000 1000000 1200000 1400000 1600000 1800000 2000000 Page 19

WireXpert s Interfaces Power on-off button Touch sensitive color LCD screen USB device connector Audio jack USB host connector for flash drive RJ-45 Ethernet for remote control Power supply jack (12V) Quick access buttons Up-down-left-right scroll buttons Context sensitive Help Brightness control Probe interface connector Battery compartment door Page 20

Value Proposition Future Proof Highest frequency range in the industry The only tester supporting all new test requirements and beyond Field upgradeable & re-evaluation for future standards Reliability & Robustness Accuracy beyond Level IV Sustains drop test from 1.5m on a concrete floor No mechanical controls, only power button Cost of Ownership No upgrade cost from Cat6 to Cat6A to Class FA Low cost of consumable accessories (permanent link test cord, battery etc.) Extreme productivity Shortest test time in the industry (less then 9 seconds) 2 Main unit design reduces walk time to half and improve work flow Ease of Use Built-in user manual Easy touch sensitive user interface on both local and remote units Page 21

Productivity and Ease of Use New Dual Control System (DCS TM ) featuring identical devices for remote and main units - makes it really easy to operate the test cycles. Whether coordinated by two technicians or only one, walking time is minimized. control of both sides reduce walking by 50% certification could be carried out by just one technician 2 sets could be transform into one main with 3 remotes total visibility on both sides If battery needs charging units simply can be swapped in the unlikely event of failure, service center will have spare unit available Page 22

Dual Control System (DCS ) PASS SAVE PASS SAVE

Productivity and Ease of Use Data transfer and update via USB drive unit stays in the field all time Easy to use Intuitive user interface makes change over easy Responsive and fast usability by Fingers touch Maximum 2 clicks away from resolution Page 24

High Reliable Concept of Test Heads Concept of test heads for Permanent Link adds to high reliability and reproducibility RJ-45 needs to be replaced after x000 insertions/tests Cable Material wears out after coiling and bending WireXpert Permanent Link solution minimizes cost of ownership Conclusion: both RJ-45 & cable need regular exchange Fluke solution expensive only repairs contacts Page 25

How do we test? Preparations A few preparations: 1. Select Cabling Standard Select standard Select class or category 2. Select Cable Select manufacturer Select cable 3. Select connecting hardware Select manufacturer Select connector 4. Setup the Site Select from database or name site 5. Setup Labeling Select the labeling scheme 6. Setup Operator Select operator or key in a name PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 26

How do we test? Autotests Start an Autotest by pressing: <9s later you will get a result: Detailed results by pressing: Select single item to view graphs OR Save result by twice pressing: Thats all! Start the next Autotest! Page 27

All Autotests done! Whats now? After you have tested all links on site, copy these to an USB - Stick 1. Insert USB - Stick into the USB Host connector of the Local unit 2. The Local unit recognizes the USB - Stick 3. And shows the menu 4. Press 5. The unit copies all test results from your site to the USB - Stick 6. Remove the USB - Stick Page 28

ReportXpert With the Autotests on the USB - Stick, we now can read them into the ReportXpert Software and Manage the Autotests, View the Autotests, Pack the projects, Print Detailed Reports of the Autotests or Print Summary Reports of the project 14.11.2011 Page 29

WireXpert What is in the Box Bill of Material WireXpert WX4500 2 pcs. Identical main units including: Li-Ion battery, strap set, stylus w. cord & display cover 1 pc. Carrying Case 2 pcs. CAT6A Permanent Link Interface Adapter 2 pcs. CAT6A Permanent Link Test Cords 2 pcs. CAT6A Channel Adapter 1 pc. 1GB USB Thumb Drive 2 pcs. Talk Sets 2 pcs. AC Power Adapters 2 pcs. Country Specific Power Cord 1 pc. Calibration Certificate Page 30

WireXpert at a Glance Fastest Handheld Copper and Fiber Testing for up to 40 Gbit/s Ethernet Networks Cat 6a/ Class E, Cat 7a/ Class FA copper certification Multi- / single mode fiber certification for length & loss Future-proof through 1 1600 MHz frequency range and software upgradeability Supports all current standards such as ISO 11801, EN50173, TIA 568 Exceeds TIA Level IV accuracy specifications, sets new standard for proposed Level V Dual Control System (DCS) with two main units improves operator efficiency Alien Crosstalk measurement for 10G over copper User friendly with vendor managed cable database, pre-defined settings and a workday of battery life Supports autotest and continuous measurement Semi automated software upgrade Page 31

End! Many thanks for your attention! Any questions?