Endo IQ ipad Mini Protective Case. Directions For Use

Similar documents
Getting Started Guide. Just a few images to help you easily set up your motor and get the most out of it.

Touch the future today

Maintenance station. For DePuy Synthes Power Tools Electric Pen Drive and Air Pen Drive Systems. instructions for use

MODEL C-HOMWA-1 CONNECTIVITY KIT, CONNEX (USB)

User Manual Revised 1-July-2015

INSTRUCTIONS FOR USE. RECHARGEABLE System for Hearing Aids

8-Bit Temperature Smart Sensor (Part # S-TMA-M0XX)

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

Deckblatt von Marketing / Foto fehlt

Endo Easy Efficient. User Manual.

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

4 Port USB Power Hub. Model: JH-800 USER MANUAL

3190 Series Touch Screen POS Workstation

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

ATOM. Instruction Manual. Head. from software version: 8.

Manual. Portable Smart Soldering Station TS100 12/24V computer-controlled, programmable, adjustable temperature. No Copyright Graupner/SJ GmbH

Smart Grid Tie Microinverter User Manual

Controller Specifications

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

USB Memory Drive CD with Application Software and Drivers for Windows 98SE. 32 MB, > 64 MB recommended. min. 2x (for probable installation)

Nokia Wireless Charging Plate DT-900 User Guide

TVAC25100 TVAC25110 User manual

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

User s Manual Power Supply IM E. 5th Edition

Installation manual plugs and connectors with screw connection (16/32 A)

Lenovo S60-a. Quick Start Guide. Read this guide carefully before using your smartphone.

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

BAM Labs Biometric Monitoring System. Instruction Manual

USERS MANUAL DIGI-DOC.COM

Always there to help you. Register your product and get support at AD295. Question? Contact Philips.


Medimaging Integrated Solution Inc.

Logitech Alert 700i/750i System Requirements & Support Guide

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Getting started with

SKF Shaft Alignment Tool

Earphones OWNER S MANUAL

Variable-Speed Vortex Mixer

Honor Whistle Smart Control Rechargeable Headset User Guide

WheelAble. Be Spontaneous. User Manual

B63/ NS MS. EtherNet/IP LINK

QUASAR 2/4/8 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

User s Guide. connected

22-60VDC Grid Tie Microinverter User Manual

GMH Operating Manual for Digital Quick-Response Thermometer

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

HX1 Bluetooth Stereo Headset

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

User Guide Wireless Charging Plate DT-903

PMX 680i SPORTS. Instruction manual

icore Kiosk system Installation Guide

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

MX-T6-PRO/S Tube Rollers

IPCB42501 / IPCB42551

USER S MANUAL English

EC Series. Safety Guide

VERTICAL CONTROL LASER OWNERS MANUAL

Operating Instructions

SL-NW100. Introduction. How to Charge. How to Mount. Switch Operation. Appendix. CatEyeSYNC Manual (PDF)

Digital Quick-Response Thermometer

powerstation AC Made for Smartphones, Tablets, Laptops, & Other USB & AC Devices USER MANUAL

Instructions for Use: Flexible Inspection Scope Camera

PowerRING Qi DUAL WIRELESS CHARGING RECEIVER

LP3 Multipurpose Laser Presenter

DC-D4213RX DC-D4213WRX

Tx Link. Quick Setup Guide. English. Connection module

USER MANUAL. For Flic. English

Operation Manual. Equipment. Operation Manual. Loctite RB30 Robot Camera. Part Number:

Network Camera. Quick Guide DC-B1203X. Powered by

powerstation & powerstation XXL Made for Apple and USB devices USER MANUAL

Always there to help you. Register your product and get support at AEA1000. Question? Contact Philips.

Weatherproof IR Color Day/Night Cameras

Continuous Wave Single Frequency Lasers. Concerto Series. 442nm 25, 50, 75 & 100mW

powerstation USB-C 3XL Made for MacBook & Other USB Devices USER MANUAL

COMPACT LED DESK LAMP WITH LCD DISPLAY

<User Manual> PM-150

ODYS Xound Mini - 1 -

Always there to help you. Register your product and get support at AEA1000. Question? Contact Philips.

Network Camera. Quick Guide DC-D1223WX. Powered by

User Manual. Printer P-52RUE

Olive_QS_SL.book Page 1 Wednesday, September 18, :41 PM Quick Start

NL-324BTR User manual (60706)

DPP Micro Reader. The DPP Micro Reader is maintenance-free, not configurable by the user and is operated with a single, multi-function button.

OPERATING INSTRUCTIONS

NIMBUS a personal dashboard for your digital life

D-Pack 6 Classic ORDERCODE 50315

Pressure Transmitter and Reader of the PT-RF Series Manual

POWER SUPPLY UNIT PSU-3

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

Thank you for your purchase USER MANUAL

BW50 SportBuds. User Guide. Control Buttons & Operations. On / Off. Play / Pause / Answer. Volume / Track Selection. Models: GDI-EXBW50...

ENGLISH. User manual

Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses.

Smartphone Photo Printer

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

Transcription:

Endo IQ ipad Mini Protective Case Directions For Use EN

PAGE INTENTIONALLY LEFT BLANK 2/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Introduction........................................... 5 1 Indications for Use...................................... 5 2 Contraindications...................................... 5 3 Warnings.............................................. 6 4 Precautions........................................... 7 5 Adverse Reactions...................................... 7 6 Step by Step Instructions................................ 7 6.1 Document Symbols.......................................... 8 6.2 Protective Case compatibility.................................. 8 6.3 Package content............................................ 8 6.4 Using Endo IQ ipad Mini Protective Case....................... 9 6.5 Activating the Assistive Touch................................ 12 7 Cleaning, Disinfection and Sterilization................... 14 7.1 Foreword................................................. 14 7.2 Single use of disposable custom barrier sleeve................... 14 7.3 Cleaning procedure........................................ 15 7.4 Disinfection procedure...................................... 15 8 Technical Characteristics............................... 17 9 Protective Case error codes............................. 18 10 Troubleshooting....................................... 18 11 Warranty............................................. 18 12 Disposal of the Product................................. 19 13 Identification of Symbols............................... 19 B EN IQPC DFU WEB / Rev.0 / 06-2018 3/20

PAGE INTENTIONALLY LEFT BLANK 4/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Indications for Use For Dental Use Only Introduction These Directions For Use (DFU) are kept current by Dentsply Sirona. The most current version can be accessed at dentsplysirona.com. The DFU has been compiled with the utmost care. Nevertheless, it is not always possible to completely rule out the risk of error, despite all efforts to do so. Some images in the DFU may vary slightly from the current device. We would appreciate your feedback in this area. If any errors are noted, please contact Dentsply Sirona. Maillefer Instruments Holding Sàrl Chemin du Verger 3 CH-1338 Ballaigues Switzerland Telephone +41 21 843 92 92 Fax +41 21 843 92 93 endo@dentsplysirona.com dentsplysirona.com 1 INDICATIONS FOR USE The Endo IQ ipad Mini Protective Case is an accessory designed by Dentsply Sirona to protect your ipad Mini during use. It is also designed to stabilize your ipad Mini and improve visibility of the information displayed by the Endo IQ App. To guarantee the safety, intended functionalities and good maintenance of the Endo IQ ipad Mini Protective Case, follow the indications given in the present DFU. Keep the DFU updated as described in the Introduction section. Dentsply Sirona will not accept any liability if the Endo IQ ipad Mini Protective Case is used, stored or manipulated outside of the indications given in the DFU. 2 CONTRAINDICATIONS There are no known contraindications. B EN IQPC DFU WEB / Rev.0 / 06-2018 5/20

Warnings 3 WARNINGS Read the following warnings before use. Some sections / texts of this DFU are dedicated uniquely to readers from a specific territory. When this happens the section / text will be clearly identified with a sentence similar to: For US / EU readers. If nothing is indicated, the text is applicable to all of the intended territories. Endo IQ ipad Mini Protective Case is supplied un-disinfected. You must reprocess it prior to first use and between patients (Follow instructions given in section 7 Cleaning, Disinfection and Sterilization). Dentsply Sirona recommends using the Endo IQ ipad Mini Protective Case for your ipad Mini. X-Smart IQ Handpiece Case can be magnetically attached to the Endo IQ ipad Mini Protective Case. The combined devices can fall if subjected to abrupt movements. Ensure the ipad Mini and the accessories are in a stable position during treatment. The Endo IQ ipad Mini Protective Case and the X-Smart IQ Handpiece Case contain permanent magnets. Magnets could affect the normal functioning of pacemakers, implanted heart defibrillators and hearing aid devices. Do not place the Endo IQ ipad Mini Protective Case or the X-Smart IQ Handpiece Case near these devices or any other object sensitive to static magnetic fields. Do not reprocess the Endo IQ ipad Mini Protective Case if the protective plugs are not properly inserted. It is mandatory to reprocess the Endo IQ ipad Mini Protective Case before shipping it to the service centre (follow instructions given in section 7 Cleaning, Disinfection and Sterilization). Protect the Endo IQ ipad Mini Protective Case with appropriate packaging when sending it for service. ipad Mini The operating conditions and limitations specified by Apple must be complied with. Always check to ensure that the ipad Mini has sufficient battery charge before starting treatment. 6/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Precautions Cleaning, Disinfection and Sterilization Never place the Endo IQ ipad Mini Protective Case in a washer-disinfector, autoclave or ultrasonic bath. If you use a disinfectant in the form of a spray, never spray the accessories directly. Instead, spray a paper towel with the surface disinfectant or use a pre-moistened disinfectant towelette (wipe). Only use surface disinfectants that are certified by officially recognized institutes that do not contain chlorine and have been declared aldehyde-free. Use only cleaning agents that do not have a protein-binding effect. Repairs and defects Do not use the Endo IQ ipad Mini Protective Case if you suspect damage or defects. If a defect should occur, contact Dentsply Sirona (Telephone +41 21 843 92 92 or fax +41 21 843 92 93). Transport Intact devices and defective devices can be transported by land freight or air freight in the original packaging. The applicable requirements must be met. 4 PRECAUTIONS There are no known precautions to take before use. 5 ADVERSE REACTIONS There are no known adverse reactions. 6 STEP BY STEP INSTRUCTIONS Refer to the section 3 Warnings to verify any special care to exercise before starting to use the Endo IQ ipad Mini Protective Case. Before use check the exact contents of the package. See 6.3 Package content. B EN IQPC DFU WEB / Rev.0 / 06-2018 7/20

Step by Step Instructions 6.1 Document Symbols Symbol Identification Additional information, explanation on operation and performance. Suggestion or advice. 6.2 Protective Case compatibility The Endo IQ ipad Mini Protective Case is compatible with ipad Mini 2, ipad Mini 3 and ipad Mini 4. See Endo IQ App User Manual - 6 Step by Step Instructions for information on the ipad models that are compatible with the Endo IQ App. Apple, the Apple logo, ipad, ipad Pro and ipad Mini are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. 6.3 Package content List of components Endo IQ ipad Mini Protective Case Endo IQ ipad Mini Protective Case Opener 8/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Step by Step Instructions List of components Accessories for ipad Mini TM 2 or 3 Accessories* for ipad Mini 2, 3 or 4 (Rubber plugs and foams). *These accessories may not be available in all kits Components not included ipad with ios Operating System. 6.4 Using Endo IQ ipad Mini Protective Case To correctly use the Endo IQ ipad Mini Protective Case, place it on a clean, dry, flat surface, and follow the steps described below. N Action A Remove carefully the Endo IQ ipad Mini Protective Case from its packaging and place it on a flat surface. B EN IQPC DFU WEB / Rev.0 / 06-2018 9/20

Step by Step Instructions N Action According to your ipad Mini model, use the suitable kit. Stick the foams of your kit at the places indicated on the Endo IQ ipad Mini Protective Case. B B Enclose and center the ipad Mini in the Endo IQ ipad Mini Protective Case. Place the corresponding plugs on the camera and the charging port. C C 10/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Step by Step Instructions N Action Pay attention to the ipad Mini orientation. In case of error, use the red key to open the protective case. Separate X-Smart IQ Handpiece Case from X-Smart IQ Handpiece Support. D D Install the X-Smart IQ Handpiece Case as a protective case holder. E 1 2 3 E Place the Endo IQ ipad Mini Protective Case and holder on a steady surface. Multiple configurations are possible. B EN IQPC DFU WEB / Rev.0 / 06-2018 11/20

Step by Step Instructions N Action F Activate the Assistive Touch function on your ipad Mini (see following section). Position 1 has a limited stability. Monitor the device carefully if you choose this position. The X-Smart IQ Handpiece Case is available in X-Smart IQ Handpiece kit (see X-Smart IQ Directions For Use) or you can buy it from your dealer or Dentsply Sirona Endodontics customer service. None of the accessories are supplied disinfected or sterilized. 6.5 Activating the Assistive Touch The AssistiveTouch feature replaces the actions of the ipad Mini Home button which is not accessible when in the Endo IQ ipad Mini Protective Case. To activate the Assistive Touch. N Key Action A Select Settings. B Select General. C D E Select Accessibility. Select Assistive Touch. Set Assistive Touch to ON. A virtual Home key is displayed. 12/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Step by Step Instructions To press the Home button with Assistive Touch. Tap on the virtual Home button. A B Select HOME. It is also possible to use the 5 fingers to swipe in and to return to the Home screen. B EN IQPC DFU WEB / Rev.0 / 06-2018 13/20

Cleaning, Disinfection and Sterilization 7 CLEANING, DISINFECTION AND STERILIZATION You must consult the special reprocessing X-Smart IQ Getting Started Guide before proceeding with cleaning disinfection and sterilization. The following parts shall be reprocessed before and after each treatment. Part Reprocessing steps Endo IQ ipad Mini Protective Case. Clean and disinfect. Do not sterilize. Dentsply Sirona accepts no liability in the event that these instructions are disregarded or processes that have not been validated are used to reprocess the accessories. 7.1 Foreword The Endo IQ ipad Mini Protective Case has not been disinfected when it is delivered. Please perform the necessary steps before the first treatment. Always ensure that only validated methods of cleaning and disinfection are used, that regular maintenance and inspections are performed on the equipment used (disinfector) and that the validated parameters are maintained in every cycle. Comply with your national guidelines, standards and requirements for cleaning and disinfection. 14/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Cleaning, Disinfection and Sterilization 7.2 Cleaning procedure The components of the kit must be cleaned and subjected to a wipe-down with a disinfection wipe prior to and following each treatment. Cleaning is intended to remove all the visible soiling (e.g. organic and inorganic) from the surface of the device and accessories so that the subsequent disinfection process can be efficient. N Cleaning steps A B Always wear protective clothes for you own safety (gloves, mask, glasses and a waterproof gown) for the reprocessing process. After any pre-cleaning, lightly soak a paper tissue or soft cloth in a mild, aldehyde-free disinfection and cleaning solution (bactericidal and fungicidal) and use it to clean/disinfect the Endo IQ ipad Mini Protective Case. 7.3 Disinfection procedure Disinfection shall be done immediately after cleaning using the procedure described below. The Endo IQ ipad Mini Protective Case and the other elements in this kit are not approved for machine-based cleaning (i.e. Thermal disinfection, washer disinfectors) and they should not be sterilized. Refer to Section 3 Warnings for important information on the reprocessing of the Protective Case. For wipe-down disinfection of components proceed as follows. Please refer to the manufacturer's information on use of the disinfectant. B EN IQPC DFU WEB / Rev.0 / 06-2018 15/20

Cleaning, Disinfection and Sterilization N Action A B C D E Always wear protective clothes for you own safety (gloves, mask, glasses and a waterproof gown) for the reprocessing process. Separate X-Smart IQ case from the Endo IQ ipad Mini Protective Case. Disinfect the surface of Endo IQ ipad Mini Protective Case paying special attention to grooves of the device. Use a single-use wipe or soft clean cloth lightly soaked in disinfectant. Remove all disinfectant residue. No visible impurities or liquid should remain on the Endo IQ ipad Mini Protective Case after disinfection. If the Endo IQ ipad Mini Protective Case is not being used immediately after the reprocessing process, keep it in a safe and clean environment and follow the instructions for storage and transport. Dentsply Sirona recommends the use of a disinfectant with Alcohol Quaternary Ammonium active ingredients (e.g. CaviWipes or CaviCide ). Do not use CaviCide1 or CaviWipes1 on any items shown or listed in this section. Use only EPA-registered disinfectants with a tuberculocidal claim. A list of EPAregistered disinfectants is available at https://www.epa.gov/pesticide-registration/list-bepas-registered-tuberculocide-products-effective-against-mycobacterium. In addition, the disinfectant should be aldehyde-free and compatible with the device and accessories (see 8 Technical Characteristics). Leave the disinfectant to act in accordance to manufacturer's instructions. Avoid leaving the disinfectant in contact with the device surfaces for a time longer than that recommended by the manufacturer of the disinfectant product. It can result in damage to the device. Endo IQ ipad Mini Protective Case 16/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Technical Characteristics 8 TECHNICAL CHARACTERISTICS Specification Description Manufacturer Dimensions Weight Material Ambient conditions Conditions for transport and storage Maillefer Instruments Holding Sàrl Chemin du Verger 3 CH-1338 Ballaigues Switzerland Telephone +41 21 843 92 92 Fax +41 21 843 92 93 endo@dentsplysirona.com dentsplysirona.com Endo IQ ipad Mini Protective Case: Length: 212 mm Width: 143 mm Height: 13mm Endo IQ ipad Mini Protective Case: 174g (0.38 lbs) TPE (thermoplastic elastomer) ABS/ PC Somalac VP290 Glass Use: in enclosed spaces Ambient temperature: 15 C - 35 C (59 F - 95 F) Relative humidity: < 80%, non-condensing at 0 C (32 F) Operating altitude: <2000 m (~ 6561ft 8in) above see level Maximum housing temperature according to IEC 60601-1 Ambient temperature: -20 C - +50 C (-4 F - 122 F) Relative humidity: 20% - 80%, non-condensing at > 40 C (104 F) B EN IQPC DFU WEB / Rev.0 / 06-2018 17/20

Protective Case error codes 9 PROTECTIVE CASE ERROR CODES N/A 10 TROUBLESHOOTING N/A 11 WARRANTY Dentsply Sirona Endodontics offers customers the following product warranty: Dentsply Sirona Endodontics guarantees proper manufacturing of the product, the use of top quality materials, performance of all required tests and compliance with all applicable relevant laws and regulations relating to the product. The full functionality of the Endo IQ ipad Mini Protective Case is covered by a 6-month warranty. Warranty period begins on the date of equipment purchase. The customer is only entitled to warranty services within the warranty period and under the condition that Dentsply Sirona has been informed of the defect within a one-month period from the date of discovery of the defect. Component Protective Case Warranty period 6 months This warranty covers only the exchange or repair of individual components or parts affected by manufacturing defects. The cost for personnel to be dispatched for purposes of technical assistance from the dealer to the customer, and / or packaging expenses of the customer will not be covered by Dentsply Sirona. Any customer claims beyond the realm of repair, such as claims for damages, will not be covered. This warranty does not include any compensation for direct or indirect personal injuries or material damage of any kind. The customer will not be entitled to damages covering downtime of the equipment. The warranty does not extend to damage for which evidence can be provided by Dentsply Sirona that such damage has been caused by negligence on the part of the user as related to Directions For Use. The warranty explicitly excludes any defects arising on the basis of: damage occurring during transportation to Dentsply Sirona for the purposes of repair; damage occurring through environmental events such as lightning strikes, fire and / or humidity. This warranty shall automatically become cancelled and void if the product has been improperly repaired, modified or manipulated in any manner by the user, by non-authorized persons or by third party personnel. Legal claims, such as under product liability law remain unaffected. 18/20 B EN IQPC DFU WEB / Rev.0 / 06-2018

Disposal of the Product 12 DISPOSAL OF THE PRODUCT Comply with your national and regional regulations, guidelines and requirements for the disposal of this product. 13 IDENTIFICATION OF SYMBOLS Normative Symbols Symbol Identification SN Serial number Batch Code Catalogue number Consult Instructions for Use Manufacturer Date of manufacture Opened packages are not replaced Temperature limit Humidity limitation Keep dry Fragile, handle with care Accessory xxx C P Do not sterilize Plastic CE Mark Caution, consult instructions for use B EN IQPC DFU WEB / Rev.0 / 06-2018 19/20

dentsplysirona.com Maillefer Instruments Holding Sàrl Chemin du Verger 3 CH-1338 Ballaigues Switzerland Telephone +41 21 843 92 92 Fax +41 21 843 92 93 endo@dentsplysirona.com dentsplysirona.com B EN IQPC DFU WEB / Rev.0 / 06-2018