BHP6602 Smart γ Camera Special NM Device for Details 1 / 6
Over View The BHP6602 is a smart γ camera just required less than eight square feet of floor space and provided DICOM compatibility. The redesigned platform provides two optional types of Detector,imaging for Tc99m. The results of this updating are increased operating efficiency, better imaging economics and improved diagnostic results. Clinical Application The new smart γ camera is a compact camera designed to perform thyroid, parathyroid, bone spots and other studies. Features Open, inviting design accommodates patients of any size and improves patient satisfaction Increased patient throughput Higher department revenue Fewer time-consuming collimator exchanges Optimal image quality and statistical analysis Exceptionally low lifetime cost of ownership Detector Design Crystal thickness:6mm Energy range:60~170kev PMT type: 19 circle,2 PMTs per detector Circular minimum 150mm FOV Detector Positioning During clinical imaging, the detector may be positioned in -45 ~90 During collimator changing, the detector will be positioned vertically in 180 Collimators 2 / 6
COLLIMATOR TYPE description Isotope memo Low Energy Pinhole With 4mm hole size Tc99m Standard configuration Low Energy High Resolution LEHR Tc99m Optional configuration Low Energy Diverging LEDV Tc99m Optional configuration System Specification Spatial Resolution (mm) Uniformity (%) Typical(low Features Range Standard energy type) FWHM 3.8 2.2 CFOV FWTM 7.8 4.1 Intrinsic FWHM 3.9 2.3 UFOV FWTM 7.9 4.2 System CFOV FWHM 9.0 -- (LEHR 100mm collimator) In air FWTM 17.0 -- Intrinsic Integral 5.0 1.8 UFOV (at count rate Differential 3.0 1.2 less than 20 Integral 4.0 1.5 CFOV kcps) Differential 2.5 1.1 Intrinsic Spatial Linearity (mm) System Sensitivity ( 10-6s-1 Bq-1) Intrinsic Energy Resolution (%) UFOV Absolute 0.9 0.4 Differential 0.4 0.2 CFOV Absolute 0.9 0.3 Differential 0.3 0.2 LEPIN 40 -- LEHR 85 -- LEDV 45 -- 10 for Tc99m Intrinsic Count Rate Performance in Air* Maximum Count Rate(20%)(kcps) Detector Shielding Leakage(System) 2 -- 8h stability (%) 2 1.3 Acquisition System 9.8 150 153 BHP6602 smart γ camera is controlled by the focusing ACQ program 3 / 6
Installed on a mainstream PC, the ACQ program combines a unique, propriety operating interface. Easy-to follow screen prompts make it extremely fast and easy-to-use. Cutting edge energy, linearity and uniformity corrections for unparalleled diagnostic quality. Acquisition protocols available for every nuclear medicine study type. Processing & Connectivity compatible with DICOM3.0 format Saving image data and information management system Integrated workstation Processor: Intel Pentium IV 3.0G CPU Memory : 2GB SDRAM 1333MHz Data Storage: 500G SATA hard disk, 7200rpm Communications: Ethernet with TCP/IP and OSI protocols CD-RW Driver 19 high resolution color monitor Power Requirements The system will not require externally mounted power conditioning devices. But the uninterrupted power supply (UPS)is recommended.base power requirements: 110 VAC, ±10%,50Hz ±1Hz 600VA Environment Recommended Operating Temperature Range: 15~27 Storage Temperature:7~40 Maximum Temperature gradient:5 per hour Recommended Relative Humidity: 40% ~ 60% (non-condensing) 4 / 6
Optional Accessories Optional Source Holder for correction or QC Optional Patient Table designed for easy positioning ECG Warranty One-year quality assurance; Provides basic operational training; Provide maintenance of products within the machine s lifetime. BHP6602 smart γ camera Room Layout 5 / 6
6 / 6