Economy Single Channel Output DC Power Supply

Similar documents
Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

99 Washington Street Melrose, MA Phone Toll Free Visit us at

ODP Series Dual Output Linear Programmable DC Power Supply User Manual

ODP Series Linear Programmable DC Power Supply User Manual

USER S MANUAL Linear Programmable DC Power Supply APS

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

ODP3031 Linear Programmable DC Power Supply User Manual

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

General Warranty. For more details, please refer to the user manual, it can be downloaded at

VDS Series PC Oscilloscopes Quick Guide

General Warranty. For more details, please refer to the user manual, it can be downloaded at

XSA1000 Series Spectrum Analyzer Quick Guide

General Warranty. For more details, please refer to the user manual, it can be downloaded at

RIGOL. Quick Guide. DP800A Series Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

2016 SIGLENT TECHNOLOGIES CO.,LTD

DM3058/DM3058E Digital Multimeter

SSA3000X Series Spectrum Analyzer. Quick Guide

Bluetooth/USB Data Logger USER S MANUAL. Hantek 365A/B/C/D/E/F V

DS1000B Series Digital Oscilloscope

1. PRODUCT INTRODUCTION Description 1-2. Feature...

1-36V, 0-3A DC Power Supply

RIGOL. User s Guide. DP1116A Programmable DC Power Supply. Mar RIGOL Technologies, Inc.

2019 RIGOL (SUZHOU) TECHNOLOGIES INC.

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

RIGOL. User s Guide. DP1308A Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

Instructions. P MHz 10X Passive Probe

USER S GUIDE Programmable DC Power Supply Model IT6322

3700 SERIES USER MANUAL

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

IT6800 series Frame Format

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

RIGOL. Service Guide. L-3400 Series Column Oven. Nov RIGOL Technologies, Inc.

RIGOL. Quick Guide. DSA1000 Series Spectrum Analyzer. Nov RIGOL Technologies, Inc

2015 SIGLENT TECHNOLOGIES CO., LTD

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

BENCHTOP INSTRUMENT. Programmable Switching DC Power Supply Operation Manual V1.0

D-Pack 6 Classic ORDERCODE 50315

Model 2380 Rack-Mount Kit

Antenna Distributor ORDERCODE D1444

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0

EPS Power Supply

Automated Tuner System Power Distribution Hub

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

9040/9040UK. Users Manual. Phase Rotation Indicator

PS-3005P Programmable DC Power Supply

OLi POWA-5 Active Monitors

Digital Control Power Supply IT6720. User s Manual. Access for more products information

INSTRUCTION MANUAL CAT ecount

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

HV-CS kv Edge Mount Triaxial Jack

FT-20 Fire Training Fog Machine User Manual English

Multiple Channel Digital Control and Programmable DC Power Supply Model: , , and

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

STYLITIS-POWER OPERATOR S GUIDE

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

TCP305A & TCP312A AC/DC Current Probes Instructions

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Multi Range DC Power Supply

Multidim ORDERCODE 50391

VMC-8114P VMC-8414P INSTRUCTION MANUAL. Colour Video Monitor

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

Model P4470 Save A Watt Operation Manual

PS8 - II. Professional Power Sequencer. User s Manual

PX Series Balances. Quick Start Guide. Please download the user manual from

FT-20 Fire Training Fog Machine User Manual English

If you have questions about your KCD-2000 and its operation, please contact technical support at

RIGOL User s Guide. DL3000 Series Programmable DC Electronic Load. Feb RIGOL TECHNOLOGIES, INC.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

MC-12 Software Installation Instructions

High Precision Quad Output DC Power Supply

MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes

AutoRanging Digital MultiMeter

User's Guide. Model High Precision Quad Output DC Power Supply

ENGLISH. User manual.

Model 7705 Control Module

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

POCKET MULTIMETER 5115 ENGLISH User Manual

EC Series. Safety Guide

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Prestigio P371 Users manual

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

LM-XX37-26 Touch Monitor User Manual One World Touch, LLC

9130B Series Triple Output Programmable DC Power Supplies. Models: 9130B, 9131B, 9132B USER MANUAL

1 Channel Strobe Controller ORDERCODE 40226

OZONE SWITCH Model OS-6. OS-6 Features

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

TDM-170 TIMER DISPLAY

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Transcription:

Economy Single Channel Output DC Power Supply User Manual www.owon.com.cn

Feb. 2019 edition V1.1.0 Copyright LILLIPUT Company. All rights reserved. The LILLIPUT's products are under the protection of the patent rights, including ones which have already obtained the patent rights and those which are applying for. The information in this manual will replace all that in the materials published originally. The information in this manual was correct at the time of printing. However, LILLIPUT will continue to improve products and reserves the rights to change specification at any time without notice. is the registered trademark of the LILLIPUT Company. Fujian LILLIPUT Optoelectronics Technology Co., Ltd. No. 19, Heming Road Lantian Industrial Zone, Zhangzhou 363005 P.R. China Tel: +86-596-2130430 Fax: +86-596-2109272 Web: www.owon.com.cn E-mail: info@owon.com.cn

General Warranty OWON warrants that the product will be free from defects in materials and workmanship for a period of 2 years (1 year for accessories) from the date of purchase of the product by the original purchaser from the OWON Company. This warranty only applies to the original purchaser and is not transferable to a third party. If the product proves defective during the warranty period, OWON will either repair the defective product without charge for parts and labour, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by OWON for warranty work may be new or reconditioned like new. All replaced parts, modules and products become the property of OWON. To obtain service under this warranty, the customer must notify OWON of the defect before the expiration of the warranty period. Customer shall be responsible for packaging and shipping the defective product to OWON's designated service centre, a copy of the customer s proof of purchase is also required. This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. OWON shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than OWON representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-owon supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product. Please contact the nearest OWON's Sales and Service Offices for services or a complete copy of the warranty statement. For better after-sales service, please visit www.owon.com.cn and register the purchased product online. Excepting the after-sales services provided in this summary or the applicable warranty statements, OWON will not offer any guarantee for maintenance definitely declared or hinted, including but not limited to the implied guarantee for marketability and special-purpose acceptability. OWON should not take any responsibilities for any indirect, special or consequent damages.

Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols... 2 3. Quick Review... 3 3.1 Panel and Interface... 3 3.1.1 Front Panel... 3 3.1.2 Rear Panel... 4 3.1.3 User Interface... 5 3.2 General Inspection... 5 3.3 Power Inspection... 6 3.4 Output Inspection... 6 4. Panel Operation... 8 4.1 Turn On/Off the Channel Output... 8 4.2 Set the Output Voltage/Current... 8 4.3 Over Voltage/Current Protection... 8 4.4 Memory key shortcut settings... 9 4.4.1 Quick output... 9 4.4.2 Edit... 9 4.5 System Settings... 10 4.5.1 Display Brightness... 10 4.5.2 Language Setting... 10 4.5.3 Buzzer... 10 4.5.4 Display (Only for P4305 and P4603)... 10 4.6 Interface Setting... 13 4.7 System Information... 14 4.7.1 Review System Information... 14 4.7.2 Restore Factory Settings... 14 5. Troubleshooting... 15 6. Appendix... 16 6.1 Appendix A:Accessories... 16 6.2 Appendix B: General Care and Cleaning... 16 General Care... 16 i

1.General Safety Requirements 1. General Safety Requirements Before use, please read the following safety precautions to avoid any possible bodily injury and to prevent this product or any other connected products from damage. To avoid any contingent danger, ensure this product is only used within the ranges specified. Only a qualified person should perform internal maintenance. To avoid Fire or Personal Injury: Use Proper Power Cord. Use only the power cord supplied with the product and certified to use in your country. Product Grounded. This instrument is grounded through the power cord grounding conductor. To avoid electric shock, the grounding conductor must be grounded. The product must be grounded properly before any connection with its input or output terminals. Check all Terminal Ratings. To avoid fire or shock hazard, check all ratings and markings on this product. Refer to the user manual for more information about ratings before connecting to the instrument. Do not operate without covers. Do not operate the instrument with covers or panels removed. Use the Proper Fuse. Use only the specified type and rating fuse for this instrument. Avoid exposed circuit. Be careful when working on exposed circuitry to avoid risk of electric shock or other injury. Do not operate if any damage. If you suspect damage to the instrument, have it inspected by qualified service personnel before further use. Use your instrument in a well-ventilated area. Please keep well ventilated and inspect the intake and fan regularly. Do not operate in damp conditions. To avoid short circuiting to the interior of the device or electric shock, please do not operate in a humid environment. Do not operate in an explosive atmosphere. To avoid damages to the device or personal injuries, it is important to operate the device away from an explosive atmosphere. Keep product surfaces clean and dry. To avoid the influence of dust or moisture in air, please keep the surface of device clean and dry. 1

2.Safety Terms and Symbols 2. Safety Terms and Symbols Safety Terms Terms in this manual (The following terms may appear in this manual): Warning: Warning indicates conditions or practices that could result in injury or loss of life. Caution: Caution indicates the conditions or practices that could result in damage to this product or other property. Terms on the product. The following terms may appear on this product: Danger: Indicates an immediate hazard or injury possibility. Warning: Indicates a possible hazard or injury. Caution: Indicates potential damage to the instrument or other property. Safety Symbols Symbols on the product. The following symbols may appear on the product: Hazardous Voltage Refer to Manual Protective Earth Terminal Chassis Ground Public Ground 2

3.Quick Review 3. Quick Review 3.1 Panel and Interface 3.1.1 Front Panel 1 2 9 8 7 6 3 4 5 Figure 3-1 Front Panel Overview 1 Display Area 2 Direction Key OK Key 3 Knob 4 On/Off Key 5 Channel Output Terminal 6 Power Button Display user interface. Select menu; select parameters; Edit the cursor. 1) Enter the menu or confirm the entered parameters. 2) Switch the display mode between Number and Curve. Select the main menu or change the value, function equals to the confirmation key. Turn on/off the channel. Output access of channel. Turn on/off the instrument. 3

3.Quick Review 7 Keylock Key 8 Memory Key 9 System Key Long press this button for more than 5 seconds to lock the panel button. Pressing any other button while locked does not work. Long press this button for more than 5 seconds to unlock. 5 sets of channel parameters can be stored for quick output. System settings, interface settings, system information. Button light instruction On/Off key:the key lights up when the channel turns on. 3.1.2 Rear Panel 1 5 2 4 3 Figure 3-2 Rear Panel Overview 1 AC Power Input Jack 2 Fuse 3 Air Vent 4 COM port AC power input interface Power fuse Air vent Connect the serial port of the instrument and external device 4

3.Quick Review 5 USB port (optional) It is used to transfer data when external USB equipment connects to the power supply regarded as "slave device". Support USBTMC communication protocol. 3.1.3 User Interface CV: Constant Voltage output CC: Constant Current output Channel output status Buzzer status Actual voltage output Actual current output Actual power output Figure 3-3 User Interface Set values of voltage Set values of current Set values of O.V.P Set values of O.C.P 3.2 General Inspection After you get a new power supply, it is recommended that you should make a check on the instrument according to the following steps: Check whether there is any damage caused by transportation. If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage, do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests. Check the Accessories The supplied accessories have been already described in the "Appendix A: Enclosure" of this Manual. You can check whether there is any loss of accessories with reference to this description. If it is found that there is any accessory lost or damaged, please get in touch with the distributor of OWON responsible for this service or the OWON's local offices. Check the Complete Instrument If it is found that there is damage to the appearance of the instrument, or the instrument can not work normally, or fails in the performance test, please get in touch with the OWON's distributor responsible for this business or the OWON's local offices. If there is damage to the instrument caused by the transportation, please keep the package. With the transportation department or the OWON's distributor responsible for this business informed about it, a repairing or replacement of the instrument will be arranged by the OWON. 5

3.Quick Review 3.3 Power Inspection (1) Use the power cord supplied with the accessories to connect the instrument to the AC power. Warning: To prevent electric shock, make sure that the instrument is properly grounded. (2) Press the power button on the front panel, the button light will be on, and the startup screen will be displayed on the screen. 3.4 Output Inspection Output inspection is to ensure that the instrument can achieve its rated outputs and properly respond to operation from the front panel. For the procedures below, it is suggested that you read "Turn On/Off the Channel Output" on page 8 and "Set the Output Voltage/Current" on page 8. 3.4.1 Voltage Output Inspection The following steps verify basic voltage functions without load: (1) When the instrument is under no load, select a channel and ensure the output current setting for this channel is not at zero. (2) Turn on the channel output, then ensure the channel is in Constant Voltage output mode. (3) Set some different voltage values on this channel; check if the actual voltage value displayed is close to the set voltage value, and also that the actual current value displayed is nearly to zero. (4) Check that if the output voltage can be adjusted from zero to the maximum rating. 3.4.2 Current Output Inspection The following steps check basic current functions with a short across the power supply's output: (1) Connect a short across (+) and (-) output terminals with an insulated test lead on this channel. Use a wire size sufficient to handle the maximum current. (2) Set the output voltage to the maximum rating on this channel. (3) Turn on the channel output. Ensure the channel you used is in Constant Current output mode. 6

3.Quick Review (4) Set some different current values on this channel; check if the actual current value displayed is close to the set current value, and to check if the actual voltage value displayed is nearly zero. (5) Check that if the output current can be adjusted from zero to the maximum rating. (6) Turn off the channel output and remove the short circuit from the output terminals. 7

4.Panel Operation 4. Panel Operation 4.1 Turn On/Off the Channel Output Press the On/Off key to turn on/off the channel; 4.2 Set the Output Voltage/Current In the channel setting area, press the / keys to move the red cursor between parameters. After selecting the output voltage/current setting value, turn the knob to change the current cursor value, and press < / > key to move the cursor position. Set values of voltage Set values of current 4.3 Over Voltage/Current Protection When the Over Voltage Protection (O.V.P) or Over Current Protection (O.C.P) is enabled, once the output voltage/current reaches the set value of O.V.P/O.C.P, the instrument will cut off the output, a warning will show on the screen. Note: When the instrument disables the output due to protection, after you make some adjustments, the channel must be restarted to output normally. This function can keep the power output from exceeding the load rating to protect the load. In the channel setting area, press the / keys to move the red cursor between parameters. After selecting the overvoltage/overcurrent protection value, turn the Knob to change the current cursor value, and press the < / > direction key to move the cursor position. 8

4.Panel Operation Set values of O.V.P Set values of O.C.P 4.4 Memory key shortcut settings Press Memory key on front panel, the M1, M2, and M3 keys can store five sets of channel parameters M1, M2, M3, M4, and M5, respectively, for quick output. 4.4.1 Quick output To output a set of parameters from M1 to M5, follow these steps: (1) Press Memory key on front panel, the shortcut interface will display. (2) Press key and shows the yellow select box. Press / to move the select box. (3) After selecting the certain parameter, press knob or OK on the panel to confirm the input value. Set values of voltage Set values of current Set values of O.V.P Set values of O.C.P 4.4.2 Edit To edit the channel parameters of M1 to M5, follow these steps: (1) Press the front panel Memory button, the screen displays the quick setup interface. (2) Press the >arrow keys to display the editing interface. (3) Press the keys to show a red cursor. (4) Press the / / < / > keys to move the red cursor between parameters. 9

4.Panel Operation Turn the knob to change the current cursor value, press the < / > arrow keys to move the cursor. Set values of voltage Set values of current Set values of O.V.P Set values of O.C.P 4.5 System Settings 4.5.1 Display Brightness Press the System softkey and turn the knob to highlight the System main menu. Press the keys to highlight the Brightness submenu. Press the < / > keys to adjust the brightness of the screen. The adjustment range is from 1 to 100. 4.5.2 Language Setting Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose the language. Press the < / > arrow keys to select the desired language. Supported languages include Chinese and English. 4.5.3 Buzzer Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose buzzer submenu. Press the < / > arrow keys to toggle the beeper on/off. When the buzzer is on, the status bar icon lights up. When the system prompts, it beeps, such as when the output is cut due to overvoltage/overcurrent protection. 4.5.4 Display (Only for P4305 and P4603) Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose Display submenu. Press the < / > arrow keys or turn the knob to set the display mode to Number or Curve. In system main interface, you can also press the OK key or press the knob to toggle between Number and Curve display mode. 10

4.Panel Operation Number Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose Display submenu. Press the < / > arrow keys or turn the knob to set the display mode to Number. In system main interface, you can also press the OK key or press the knob to select the Number display mode. When the power supply is powered on, the default display mode is Number. Curve Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose Display submenu. Press the < / > arrow keys or turn the knob to set the display mode to Curve. In system main interface, you can also press the OK key or press the knob to select the Curve display mode. Curve Type You can set the type of the displayed curve to voltage curve or current curve. 1) Voltage Curve Two methods to set the curve type to voltage curve. 1st Method: Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose Display submenu. Press the < / > arrow keys or turn the knob to set the display mode to Curve. Press the arrow keys to choose CurveType submenu, press the < / > arrow keys or turn the knob to set the curve type to Volt. 11

4.Panel Operation 2nd Method: In system main interface, you can also press the OK key or press the knob to select the Curve display mode. Press the / arrow keys to select the Volt curve type. The display mode of Volt curve is as below: Note: In Volt curve display mode, you can still set the value of voltage or current. Press the < / > arrow keys or turn the knob to enter editing mode (edit voltage first). If the value is not changed, editing mode will be exited. 2) Current Curve Two methods to set the curve type to current curve. 1st Method: Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose Display submenu. Press the < / > arrow keys or turn the knob to set the display mode to Curve. Press the arrow keys to choose CurveType submenu, press the < / > arrow keys or turn the knob to set the curve type to Curr. 2nd Method: In system main interface, you can also press the OK key or press the knob to select the Curve display mode. Press the / arrow keys to select the Curr curve type. The display mode of Curr curve is as below: 12

4.Panel Operation Note: In Curr curve display mode, you can still set the value of voltage or current. Press the < / > arrow keys or turn the knob to enter editing mode (edit current first). If the value is not changed, editing mode will be exited. Curve Time Press the System softkey and turn the knob to select the [Utility] menu. Press the arrow keys to choose CurveTime submenu. Press the < / > arrow keys or turn the knob to set the display mode to Curve. Press the arrow keys to choose CurveTime submenu, press the < / > arrow keys or turn the knob to set the curve time to 30S or 60S.. 4.6 Interface Setting (1) Press the arrow keys to select the baud rate, and press the < / > arrow keys to set the baud rate of the RS232 serial interface. The optional values for the baud rate are: 2400, 4800, 9600, 19200, 38400, 57600, 115200, and the factory default setting is 115200. Make sure the instrument's baud rate setting matches the baud rate setting of the computer you are using. 13

4.Panel Operation (2) Press the arrow keys to select the check digit and press the < / > arrow keys to toggle None, Odd, Even. (3) Press the arrow keys to select the stop bit, and press the < / > arrow keys to toggle 1 or 2. Note: The data bits submenu cannot be set, and the data bits are fixed at 8 bits. 4.7 System Information 4.7.1 Review System Information Press the System softkey and turn the knob to select the [SYSTEM] menu. The screen shows the model number, version number, and serial number of the machine. 4.7.2 Restore Factory Settings Press the System softkey and turn the knob to select the [SYSTEM] menu. Press arrow keys to select the Factory Reset submenu. Press OK to restore the factory default settings. See the factory setting detail table below Output Voltage Current 5 V 2 A Limit Voltage MAXOUT Current MAXOUT System Backlight 50% Buzzer On Baud Rate 115200 Port Port Data Digit 8 Setting Parity Check None Stop Digit 1 Display (Only for special models) Number 14

5.Troubleshooting 5. Troubleshooting 1. The instrument is powered on but no Display. Check if the power is connected properly. Check if the fuse which is below the AC Power socket is used appropriately and in good condition (the cover can be pried open with a straight screwdriver). Restart the instrument after the steps above. If the problem still exists, please contact OWON for our service. 2. The output is abnormal: Check if the output voltage is set to 0V. If so, set it to other value. Check if the output current is set to 0A. If so, set it to other value. When in programmable output status, check if there is any voltage/current value is set to 0. If so, set it to other value. If the problem still exists, please contact OWON for our service. 15

6.Appendix 6. Appendix 6.1 Appendix A:Accessories (The accessories subject to final delivery. ) standard: power cord CD User Manual Fuse optional: Banana plug to crocodile clip test leads USB2.0 to RS232 common port connector 6.2 Appendix B: General Care and Cleaning General Care Do not store or leave the instrument where the liquid crystal display could be exposed to direct sunlight for long periods of time. Caution: To avoid any damage to the instrument, do not exposed it to any sprays, liquids, or solvents. Cleaning Inspect the instrument as often as operating conditions require. To clean the instrument exterior, perform the following steps: 16

6.Appendix Wipe the dust from the instrument surface with a soft cloth. Take care not to scratch the transparent LCD protection screen when cleaning. Disconnect power before cleaning your instrument. Clean the instrument with a damp soft cloth (not dripping with water). It is recommended to clean with soft detergent or fresh water. To avoid damage to the instrument, do not use any corrosive chemical cleaning agents. Warning: Before re applying power, ensure that the instrument is completely dry, avoiding any electric shock or electrical short circuit resulting from moisture. 17