CSU 0201 Compute Sled Unit

Similar documents
CSU 0111 Compute Sled Unit

VIRTUAL EDGE PLATFORM 4600 Next Generation Access

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6000 High-Density Server

Flexible General-Purpose Server Board in a Standard Form Factor

Cisco UCS B200 M3 Blade Server

Huawei FusionServer. V5 Rack Server HUAWEI TECHNOLOGIES CO., LTD.

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server

HUAWEI Tecal X6000 High-Density Server

HQ-BOX 1F Embedded Industrial Server External Design Specification (EDS)

Altos T310 F3 Specifications

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Cisco UCS C24 M3 Server

ThinkServer RD450 Platform Specifications

Cisco UCS C200 M2 High-Density Rack-Mount Server

Boundless Computing Inspire an Intelligent Digital World

HostEngine 5URP24 Computer User Guide

Cisco UCS C240 M3 Server

Cisco UCS B440 M1High-Performance Blade Server

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Cisco HyperFlex HX220c M4 Node

Intel Xeon E v4, Windows Server 2016 Standard, 16GB Memory, 1TB SAS Hard Drive and a 3 Year Warranty

Innovation Makes Computing Simple

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Cisco UCS C240 M3 Server

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Oracle Database Appliance X6-2L

Cisco UCS B230 M2 Blade Server

HUAWEI Tecal X8000 High-Density Rack Server

WiRack19 - Computing Server. Wiwynn SV324G2. Highlights. Specification.

Capacity driven storage server. Capacity driven storage server

Oracle Database Appliance X6-2S / X6-2M

Cisco UCS B460 M4 Blade Server

Oracle Database Appliance X6-2S / X6-2M

Huawei FusionServer. V5 Rack Server HUAWEI TECHNOLOGIES CO., LTD.

NEC Express5800/R120e-1M System Configuration Guide

ATCA-7540-D Data Sheet Bladed server platform with flexible I/O connectivity and ultimate processing performance

Acer AR320 F1 specifications

Acer AR320 F2 Specifications

Cisco HyperFlex HX220c Edge M5

Huawei RH1288 V3 Rack Server Datasheet. Overview. Check its price: Click Here. Quick Specs. Product Details

ORACLE DATABASE APPLIANCE X3 2

Full Featured with Maximum Flexibility for Expansion

NEC Express5800/R120h-2E System Configuration Guide

NEC Express5800/B120f-h System Configuration Guide

NEC Express5800/R120d-2M Configuration Guide

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Sugon TC6600 blade server

NEC Express5800/R120h-2M System Configuration Guide

Intel IP Network Server NSI2U

NEC Express5800/R120h-1M System Configuration Guide

Density Optimized System Enabling Next-Gen Performance

January 28 29, 2014San Jose. Engineering Workshop

Product Introduction of Inspur Server NF5280M4

Oracle Server X6-2L. Product Overview

Oracle Database Appliance X6-2-HA

Acer AT110 F2 Specifications

Cisco MCS 7815-I1 Unified CallManager Appliance

Acer AT310 F2 Specifications

Cisco MCS 7825-I1 Unified CallManager Appliance

Oracle Server X7-8. Dual Four-Socket Configuration. Product Overview

SUN SERVER X2-4 SYSTEM

Intel Select Solution for ucpe

COMPUTING ATCA AdvancedTCA Processor Blade

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

NEC Express5800/D120h System Configuration Guide

SUN SERVER X3-2 SYSTEM

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

QuickSpecs. HPE Cloudline CL7100 Server. Overview

Cisco MCS 7815-I2 Unified CallManager Appliance

COMPUTING ATCA G ATCA Server Blade

Oracle Server X6-2. Product Overview

Acer AC100 Server Specifications

GW2000h w/gw175h/q F1 specifications

Samuli Toivola Lead HW Architect Nokia

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Oracle Database Appliance X7-2S / X7-2M

SUN BLADE 6000 VIRTUALIZED 40 GbE NETWORK EXPRESS MODULE

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Intel Select Solutions for Professional Visualization with Advantech Servers & Appliances

COMPUTING ATCA G ATCA Server Blade

Cisco MCS 7845-H1 Unified CallManager Appliance

Figure 1 shows the appearance of Huawei FusionServer RH8100 V3 Rack Server. The RH8100 V3 provides three front I/O modules:

Data Sheet FUJITSU Server PRIMERGY CX2550 M4 Dual Socket Server Node

Acer AW2000h w/aw170h F2 Specifications

Red Hat Ceph Storage and Samsung NVMe SSDs for intensive workloads

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

Mika Hatanpää Head of AirFrame data center solutions R&D Nokia

COMPUTING ATCA-7480-D. Ruggedized 40G Server Blade

Data Sheet FUJITSU Server PRIMERGY CX2550 M4 Multi-node Server

SUN SERVER X2-8 SYSTEM

Intel Select Solution for NFVI with Advantech Servers & Appliances

Cisco MCS 7835-H2 Unified Communications Manager Appliance

RS U, 1-Socket Server, High Performance Storage Flexibility and Compute Power

NEC Express5800/R120h-1E System Configuration Guide

Data Sheet FUJITSU Server PRIMERGY CX2550 M4 Multi-node Server

NEC EXPRESS5800/R320a-E4 Configuration Guide

Cisco UCS E-Series Servers

Transcription:

CSU 0201 Compute Sled Unit Ericsson Software Defined Infrastructure Ericsson Compute Sled Unit (CSU) 0201 is an Intel Rack Scale Design (RSD) optimized compute resource supporting hardware disaggregation with Ericsson Storage Sled Units (SSU). It increases efficiency and hardware utilization through seamless scaling of compute and storage infrastructure to fit workload needs. CSU 0201 also provides next generation out-ofband management with RSD/PSME, which secures separation of cloud management and equipment management. Each compute sled can accommodate up to two Intel Xeon Scalable processor CPUs, providing exceptional processing performance and monumental leaps in I/O, memory, storage and network technologies.

2 Features and Benefits Latest Intel processor technology CSU 0201 uses Intel Xeon Scalable processor to provide the latest features on the market. Open and redundant management CSU 0201 uses Redfish compliant PSME RestAPI which is a RSD (Rack Scale Design) compliant and open interface. The Ericsson Command Center management system accesses the CSU 0201 out of band through the fully redundant 2x 1GE management ports. Fixed configurations CSU 0201 is offered in fixed configurations with CPU, memory, drives and interface cards, covering a wide range of application and use cases. The uniform infrastructure with fewer variants strongly supports the cloud paradigm where hardware infrastructure is provided in selected flavors to enable re-use in a software-defined hardware environment, which improves utilization and time to market for new services. High speed memory for demanding virtualization and cloud workloads Up to 3 TB in 24 dual in-line memory module (DIMM) slots support memory-hungry virtualization environments with low latency. Expansion slots The CSU 0201 sled has four PCIe Gen3*16 expansion slots that accepts standard low profile PCIe cards, this enables a very flexible configuration to optimize an application setup. The CSU 0201 has the capability to support high speeds NIC s such as 100/4*25Gbps and High performance HBA such as SAS 24*12Gbps. Flexible storage options CSU 0201 provides ten hot pluggable 2.5 inch slots which can be populated with up to 8 NVMe Drives or ten SAS/ SATA drives. The NVME option provides ultra- fast data access suitable for caching and in-memory data bases. Optionally you can have one or two M.2 drives NVME/SATA for logging, booting etc. You can also use Ericsson Command Center to attach one or more Ericsson Storage sled Units (SSU) to the CSU through a high speed SAS HBA 8*12Gbps vi an optical connection. If you have configured the compute resources of the CSU into the common pool, you can add storage resources as part of a vpod configuration. Redundancy The CSU 0201 is designed to fully support redundant configurations. Power supplies, equipment management and control network ports are in the basic configuration all duplicated. The four flexible PCI card slots can be configured for redundant NIC s and HBA s. More powerful with lower cooling costs The CSU 0201 is designed for the extended temperature range 5-40 degrees Celsius. This in combination with the next generation Intel Xeon Scalable processor technology which increases performance and enhancing the power efficiency, makes it possible to overall lower the OPEX. Disaggregated The disaggregated architecture of the Ericsson SSU (Storage Sled Unit) helps your business seize opportunities faster at a lower cost. For instance, if the lifecycle of the compute resources in your CSU is shorter than the lifecycle of the storage resources in your Storage Sled Units (SSUs), you can upgrade the compute resources on their own schedule without worrying about compatibility with the storage resources. Faster networking across longer distances Possibility to have single-mode optics gives CSU 0201 the capability to support networking across 25GE/100GE and high speed PCIe/SAS protocols with limited error correction. It supports distances between resources longer than 500 meters with no significant latency. CSU 0201 Rear View

3 Ericsson Software Defined Infrastructure CSU 0201 is a hardware component in Ericsson Software Defined Infrastructure, which provides a common managed hardware pool for all workloads. The pool can be dynamically scaled and used to create multiple environments to enable fast service rollout, performance optimization and efficient hardware utilization. Ericsson Software Defined Infrastructure key features include multi virtual-pod (vpod), hardware management across the common hardware pool with an open, single integration point and independent of vendor. CSU 0201 is suitable to be integrated in a Software Defined Infrastructure system where the vpods are using the common hardware pool to dynamically create sets of compute and storage hardware logically isolated from each other. Based on the common hardware pool, vpods can be used to deploy applications in cloud-, appliance-, container-, or bare metal environments. The pool can also be shared across organizations with tenant separation where each department has its own environment. The vpods are used by operators to quickly set up multiple hardware environments to support various flavors of NFVI with optimized performance and utilization. This capability makes it possible to support the implementation of predevelopment environments replicating the production environment, e.g. when introducing new applications. The benefits are fast deployment of new services, improved operational efficiency and better utilization of the hardware. Specifications Form Factor 2 U mounted in CPA 0201 chassis Dimensions sled Width 440 mm (full width) 17.32 inches (full width) Height 1U (42mm) 1U (1.65 inches) Depth 840 mm 33 inches Weight About 20 kg/44 lbs for maximum configuration Environmental Operating temperature: 5 C to 40 C (41 F to 104 F) Non-operating temperature: -40 C to 65 C (-40 F to 149 F) Operating relative humidity: 20% to 85% RH Non-operating relative humidity: 10% to 90% RH Processor Processor Type Intel Xeon Scalable processor Number of processors Two Internal Interconnect 10.4 GT/s L3 Cache SKU dependent Maximum TDP Support 205W Memory Total Slots 24 DIMM slots (12 per socket) Capacity Up to 3.0 TB Memory Type DDR4 RDIMM or LRDIMM On-board flash memory M.2 8 GB NVMe/SATA I/F

4 Specifications Precision timing protocol IEEE 1588 PTP deploying SyncE for frequency synchronization Storage Type Ten hot pluggable 2.5 inch slots which can be populated with up to 8 NVMe Drives or ten SAS/SATA drives Interface PCIe x 4 for SSD SATA 6 Gbps for HDD and SSD System management IPMI v2.0-compliant DCMI 1.0 Redfish 1.1 Remote system management IPMI v2.0-compliant DCMI 1.0 SOL (Serial over LAN) over 1 GbEinterface KVM (keyboard, video, mouse)over IP Management interface 2 x 1 GbE infrastructure controlchannels 2 x 1 GbE out of bandmanagement Firmware Legacy UEFI BIOS with fallbackfunction Security Trusted Platform Module (TPM)2.0 allowing support for TrustedExecution Technology (TXT) Supported operating systems and virtualization software SUSE Linux Enterprise Server(SLES) Red Hat Enterprise Linux (RHEL) Ubuntu Server VMware Microsoft Windows Server Video Integrated AST2500 with 8MBDDR3 video memory Ethernet interface Baseline 4 x 10 GbE qsfp+ cage Additional configurable NICsthrough expansion slot 4 x 10 GbE or 2 x 40 GbE VFIoptical connections 8 x 25 GbE or 2 x 100 GbE(limited to 100 GbE traffic flow)vfi optical connections Expansion slots Four PCIe Gen3 x 16 slots forhhhl standard PCIe cards Examples of configurable NICs and HBAs through expansion slots Eth NIC 4 x 10 GbE or 2 x 40GbE (limited to 50 GbE trafficflow) VFI optical connections Eth NIC 2 x 25 GbE VFI opticalconnections Eth NIC 1 x 100 GbE or 4 x 25GbE VFI optical connections Eth NIC 8 x 25 GbE or 2 x 100GbE (limited to 100 GbE trafficflow) VFI optical connections SAS HBA 8 x 12 Gbps, VFIoptical or SAS mini HDconnections SAS HBA 16 x 12 Gbps SASHBA VFI optical or SAS mini HDconnections SAS HBA 24 x 12 Gbps SASHBA VFI optical or SAS mini HDconnections Fiber channel Single Gen6 32GbSFP+ VFI optical Fiber channel Single Gen5 16GbSFP+ VFI optical Power supply Support for redundant PSU s (1+1)>100-240 VAC 1600W>- 48 VDC 1100W

5 Standards and regulations EMC EMC Directive, ETSI EN 300 386, Electromagneticcompatibility and Radio spectrum Matters(ERM); Telecommunications network equipmentelectromagnetic Compatibility (EMC) requirements Emission CISPR 32 /EN 55 032, Limits and Methods ofmeasurement of Radio Interference Characteristicson Information Technology Equipment Immunity CISPR 24/EN 55 024 :2015 CISPR 35/EN 55 035:2016 FCC 47 Part 15: subpart B Unintentional radiators Safety Low Voltage Directive 2014/35/EU IEC/EN 60 950-1:Safety of information technology equipment ANSI/UL 60 950-1:2 ed, Safety of Information technologyequipment UL/CSA C22. No. 60 950-1:2 ed, Safety ofinformation technology equipment RoHS RoHS Directive, 2011/65/EU EN 50 821, Technicaldocumentation for the assessment of electrical andelectronic products with respect to the restriction ofhazardous substances ericsson.com 13/221 02-FGB 101 0554 Ericsson AB 2018