Installation Instructions

Similar documents
Installation Instructions

FLEX Ex Spring Clamp Terminal Base

You cannot install the module unless the connector is fully extended. ATTENTION: Allen-Bradley HMIs

Installation Instructions. FLEX I/O D-Shell Terminal Base Units and Distribution Boards

Allen-Bradley. User Manual. FLEX I/O Isolated Analog Modules. (Cat. No IF4I, -OF4I, and -IF2XOF2I)

24 Input/8 Output AC Block I/O Module

FLEX I/O EtherNet/IP Adapter Module

Installation Instructions

CompactBlock Guard I/O EtherNet/IP Safety Modules

PanelView Plus/VersaView CE Terminals and Display Modules

FLEX Ex Bus Isolator and Flexbus Connector

Installation Instructions

Installation Instructions

PCI 2 Axis Servo Card

CompactLogix Power Supplies Specifications

Allen-Bradley. User Manual. Remote I/O Adapter Module. (Cat. No ASB Series C and D)

PCI 2 Axis Servo Card

About the FLEX I/O and FLEX Ex I/O Systems

Digital ac/dc (24V) Input Module

Installation Instructions

ControlLogix Redundant Power Supply Chassis Adapter Module

User Manual (Cat. No IRT8)

FLEX Integra 4 Input Module

ArmorPoint I/O Field Potential Distributor, Series A

Installation Instructions

FLEX Integra 2 Input/2 Protected Output Module

Installation Instructions

Allen-Bradley. User Manual. FLEX I/O 2 Input Incremental Encoder Module (Cat. No ID2) Allen-Bradley Motors

Installation Instructions

Digital ac/dc (24V) Input Module

FlexArmor 24V dc Sinking Input Modules

Attention helps you: identify a hazard avoid the hazard recognize the consequences

WARNING! ATTENTION! IMPORTANT

1756 ControlLogix Chassis Specifications

Power Supply HARTING pcon

Installation Instructions

FP-PS-4. Features. Installation

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

POINT I/O PROFIBUS Adapter

Power Supply HARTING pcon

VersaView Industrial Non-display Computers

AC/DC (120V) Input Module Cat. No IAD Series C

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

TN-5308 Quick Installation Guide

USER MANUAL 3170-INTB

FP-2000/2010 FieldPoint Quick Start Guide

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Allen-Bradley 1786-RPFRXL

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

User Manual Allen-Bradley

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

1756 ControlLogix Chassis Specifications

Digital input modules

NI 6521 Specifications

Analog Voltage Combination Module

Stride Industrial Ethernet Switches

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Installing Your 1394 Drive Interface Module

Redundancy Module QUINT-DIODE/40

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

ControlLogix DC (10-30V) Isolated Output Module

MINI-PS AC/10-15DC/8

ALLEN BRADLEY RELAY Bulletin 700-HF

InView Communication Modules

ArmorPoint 24V dc Input Modules, Series A

Isolated 24V dc Output Module

You need the following to set up and use your terminal block:

(Catalog Number 1770-KFD and 1770-KFDG)

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

TRC-190 User s Manual

POINT I/O Family. Chapter. Overview

PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

The ac input module is shipped in a static shielded bag to guard against electrostatic discharge damage. Observe the following precautions when

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

Relay Contact Output Modules

ControlLogix DC ( V) Electronically Fused Output Module

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

In this section we tell you how to initially handle your module, key your I/O chassis, install your module and make your wiring connections.

Power supply CP-C 24/5.0

Embedded I/O Expansion Board with 10 Outputs

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

MobileView Junction Box

ASI QUINT /2.4 EFD

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

1492-SP Supplementary Protectors

Logix5000 Control Systems: Connect POINT I/O Modules over a DeviceNet Network

Redundancy unit CP-A RU

Installation Instructions

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Power supply module, bus connection module

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

PHOENIX CONTACT - 07/2006

1769 Compact I/O Communication Bus Expansion Cables

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Installation Data. The 1771 IH module is compatible with the following 2 wire devices: pushbuttons limit switches float switches selector switches

DeviceNet ArmorBlock Network Powered 16-input Module

Kinetix 6000 Axis Module and Shunt Module

PACSystems RX7i IC698CHS009/119

1. Turn off power to the I/O chassis.

Transcription:

Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the position required for the installed module 5 Mounting holes for panel mounting 6 Terminal strips for input/output, power and common connections 7 Terminal strip cover 8 Locking tab 9 Module locking latch 10 Cover plug for male flexbus connector FLEX I/O is a trademark of Rockwell Automation.

2 FLEX I/O Terminal Base European Union Directive Compliance If this product has the CE mark it is approved for installation within the European Union or EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the following standards, in whole or in part, documented in a technical construction file: EN 50081-2 EMC Generic Emission Standard, Part 2 Industrial Environment EN 50082-2 EMC Generic Immunity Standard, Part 2 Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131 2 Programmable Controllers, Part 2 Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: Industrial Automation Wiring and Grounding Guidelines for Noise Immunity, publication 1770-4.1 Automation Systems Catalog, publication B111 This equipment is classified as open equipment and must be mounted in an enclosure during operation to provide safety protection. Mounting on a DIN Rail! ATTENTION: Do not remove or replace a terminal base unit when power is applied. Interruption of the flexbus can result in unintended operation or machine motion. 1. Remove the cover plug (if used) in the male connector of the unit to which you are connecting this terminal base unit. 2. Check to make sure that the 16 pins in the male connector on the adjacent device are straight and in line so that the mating female connector on this terminal base unit will mate correctly.

FLEX I/O Terminal Base 3 3. Make certain that the female flexbus connector C is fully retracted into the base unit. 4. Position the terminal base on the 35 x 7.5mm DIN rail A (A-B pt. no. 199-DR1). B DIN Rail A A Position the terminal base at a slight angle and hooked over the top of the DIN rail. 30246 M Slide the terminal base unit over tight against the adapter. Make sure that the hook on the terminal base unit slides under the edge of the adapter and the flexbus connector is fully retracted. 30247 M

4 FLEX I/O Terminal Base! ATTENTION: Do not force the terminal base into the adjacent base/adapter. Forcing the units together can bend or break the hook and allow the units to separate and break communication over the backplane. 5. Rotate the terminal base onto the DIN rail with the top of the rail hooked under the lip on the rear of the terminal base. Use caution to make sure that the female flexbus connector does not strike any of the pins in the mating male connector. Press down on the terminal base unit to lock the terminal base on the DIN rail. If the terminal base does not lock into place, use a screwdriver or similar device to open the locking tab, press down on the terminal base until flush with the DIN rail and release the locking tab to lock the base in place. 30252 M Gently push the flexbus connector into the side of the adapter to complete the backplane connection. 30249 M

FLEX I/O Terminal Base 5 6. For specific wiring information, refer to the installation instructions for the module you are installing in this terminal base unit. 7. Repeat the above steps to install the next terminal base. Wiring! ATTENTION: Total current draw through the terminal base unit is limited to 10A. Separate power connections may be necessary. 1. Snap open terminal strip cover. 2. Connect input or output wiring to even numbered terminals 0 through 14 on the (B) row, and odd numbered terminals 1 through 15 on the (C) row. For specific wiring information, refer to the installation instructions for the module you are installing in this terminal base unit. 16 Even Numbered Terminals 0 thru 14 33 16 0 2 4 6 8 10 12 14 33 34 1 3 5 7 9 11 13 15 51 34 Odd Numbered Terminals 1 thru 15 51 B = 16, 0, 2, 4, 6, 8, 10, 12, 14, 33 C = 34, 1, 3, 5, 7, 9, 11, 13, 15, 51 1794-TBN 3. Connect supply power to terminal 34 on row (C). 4. Connect supply common/return to terminal 16 on row (B). 5. If continuing supply voltage to the next terminal base, connect terminal C-51 to terminal C-34 on the next terminal base unit. 6. If continuing supply common/return to the next terminal base, connect terminal B-33 to terminal B-16 on the next terminal base unit. B C

6 FLEX I/O Terminal Base 24V dc 24V dc ac Wiring when total current draw is less than 10A 24V dc 24V dc or ac Wiring when total current draw is greater than 10A

FLEX I/O Terminal Base 7 1.4 (35) 3.7 (94) 0.9 (23) 3.2 (80) 2.0 (50) 3.7 (94) 3.2 (80) (87) 1.2 (28) C = Operating temperature 1.0 (25.4) below each module when mounted in any position must not exceed 55 degrees C (131 degrees F) Measure here for horizontal position 3.7 (94) 1794-TB2, -TB3 3.7H x 3.7W x 2.7D (94H x 94W x 69D) 3.7 (94) 1794-TBN 3.7H x 3.7W x 2.7D (94H x 94W x 69D) B C Here for vertical mounting position with adapter up A B 3.4 Inches (Millimeters) = DIN rail.83 (21) 1.4 (35) 2.7 (68) 1794-ASB 3.4H x 2.7W x 2.7D (87H x 68W x 69D) Secure DIN rail approximately every 200mm. = Mounting hole dimensions for optional mounting kit A 2.3 (59)

8 FLEX I/O Terminal Base 1794-TBN Specifications Number of Terminals Terminal Screw Torque Dimensions (with module installed in base) Inches (Millimeters) Current Capacity Voltage Rating Isolation Voltage Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category 1 Agency Certification (when product is marked) 2 rows of 10 terminals 7-9 inch-pounds 3.7H x 3.7W x 2.7D (94H x 94W x 69D) 10A maximum 264V ac maximum 100% tested at 2500V dc for 1s between user and system Channel-to-channel isolation determined by inserted module. 0 to 55 o C (32 to 131 o F) 40 to 85 o C ( 40 to 185 o F) 5 to 95% noncondensing 30 g peak acceleration, 11(+1)ms pulse width 50 g peak acceleration, 11(+1)ms pulse width Tested 5 g @ 10 500Hz per IEC 68-2-6 12 gauge (4mm 2 ) stranded maximum 3/64 inch (1.2mm) insulation maximum (Established by inserted module.) CSA certified CSA Class I, Division 2 Groups A, B, C, D certified UL listed CE marked for all applicable directives 1 You use this conductor category information for planning conductor routing as described in Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. With major offices worldwide. World Headquarters, Allen-Bradley 1201 South Second Street Milwaukee, WI 53204 USA Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Publication Supersedes publication 1794-5.16 December September 1995 1998 PN955123 87A Copyright 1998 Allen-Bradley Company, Inc. Printed in USA