F1x3L Fiber Optic Tap LC

Similar documents
F1L 1-Link LC Fiber Optic Tap

C Mb Ethernet Copper Tap

C1-1G Single Port Copper Tap

User Manual C1AP-100. Industrial Ethernet Protocol Analyzer

PROFISHARK 1G User manual

Package contents. 1 x ProfiShark 10G main unit 1 x USB key containing drivers, software and manual 1 x USB 3.0 cable 1 x Carrying pouch

Installation Guide for Flex Tap

Installation Guide for Fiber Tap HD8

ProfiShark 1G User manual

10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan

TRENDnet User s Guide. Cover Page

Technical Specification. for. 10 Gbps SFP+ Checker

SATA II HDD Canister KISS DA 435 Quick Reference Guide

4800 Series FIBER OPTIC DVI EXTENSION SYSTEM

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

DPN-4 Duo. User Manual. 4-Port Dual-Head Displayport KVM switch with USB 2.0 and Audio Sharing

Quick Start Guide. Cisco Compatible 10Gbase-LR SFP+ Transceiver with DDM, SMF, 1310 nm, 10 km, LC. Model: N286-10GLR-SLC PROTECT YOUR INVESTMENT!

Copyright Black Box Corporation. All rights reserved.

DPN 4 Duo. User Manual. 4-Port Dual-Head DisplayPort 1.2 KVM Switch with USB 2.0 and Audio Sharing

5100 Series. Fiberlink. 10/100/1000 Base-T Etheret over one or two single mode or multimode fibers. User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Made in U.S.A. 1

Volition. Fast Ethernet Fiber Optic Media Converters. Installation Manual VOL-0205/VOL-0206 /VOL-0207/VOL December

6400 CWDM Series. Fiberlink. 4 or 8 Channel Coarse Wave Division Multiplexers for Single Mode Fiber. User s Manual

XC300 VDSL Network Extender Owners Manual

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

Piccola Smart Box Member of Modul MAS family

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

Extended Range IR Illuminator Operator Manual

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

LB-HDMI/DE LINK BRIDGE TM HDMI AUDIO DE-EMBEDDER SYSTEM

AEXX-349 SERIES REMOTE DISPLAYS

UHDN 4P Duo. User Manual. 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support. Manage 4 computers from a single workstation

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual. BDM Rev. C

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

1X2 HDMI Splitter with 3D Support

PMDX-105 Quad Isolator Board

OPERATIONS MANUAL PCM-DOC

EXT-DVI-FM1000P User Manual

3M Passive Optical Splitter Shelves and Modules

Owner s Manual. Media Converters Models: N SC & N ST

THECHARGEHUB.COM. User Manual. For Square & Round Models

DVN 8Pro. User Manual. 8-Port DVI-D KVM Switch with Audio and USB 2.0 Sharing

CAN Fiber Optic Modem

IQeye 4 Series Dome. IQinVision. When you can t afford to miss a thing. Installation & Operating Instructions

LED..O..M Series Diffused On-Axis Lights

PSA200 User s Manual

LB-HDMI/DE LINK BRIDGE TM HDMI AUDIO DE-EMBEDDER SYSTEM

USB Server User Manual

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Owner s Manual. Gigabit Fiber to Ethernet Media Converters with PoE

Light-Source Mainframe

General and Copyright Notice Warranty OmniConverter Limitation of Warranty Environmental Notices User Manual

MEC-LAN-M002. User s Manual

WARRANTY & LIMITATION OF LIABILITY

ETConcept Systems Engineering. User s Guide

Advanced 4/8-Port DVI-D Matrix KVM

WARRANTY & LIMITATION OF LIABILITY

TERMS & CONDITIONS. Complied with GDPR rules and regulation CONDITIONS OF USE PROPRIETARY RIGHTS AND ACCEPTABLE USE OF CONTENT

SNAP Compact Fiber Optic Patch Panel

Vocia ELD-1. Operation Manual

Online Connection Kit. Installation Manual

ADVANCED 4/8 PORT DVI-D MATRIX SECURE KVM SWITCH

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

iconverter 2-Module Power Chassis

User s Manual. Two (2) PCs Switchable Dual-head DVI Optical KVM Extender, KVMX-100-TR. Opticis Locations.

ADAM Fiber Optic to RS-232/422/485 Converter

Handheld Reader Writer

Kramer Electronics, Ltd. USER MANUAL. Model: VA-1DVIN. Virtual EDID

Document ID: DOC-IPG-2004 Revision: 1.10 Release Date: December 13th, Advanced 2/4-Port DVI-I Secure KVM Switch

OL-KT. Online Connection Kit Installation Manual

TRENDnet User s Guide. Cover Page

AMT-12 AMT-15. Professional Loudspeakers. Installation and Use Manual

QPP Proprietary Profile Guide

Sensoray Model 627 CompactPCI to PCI Adapter

Tiger Serve1 Assembly Guide

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

MLC. Semi-Metal USB. Generation 3L HERMIT-C Series. Product Specification MLC. Semi-Metal USB Flash Disk Generation 3L

USB C-to-SATA DriveLock User s Guide

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

XC4100 INSTALLATION/OWNER'S MANUAL AM/FM/Cassette Receiver

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

ADVANCED 1/2/4-PORT DVI-I SECURE KVM SWITCH

MEC-COM-M154. User s Manual

PCMCIA Flash Card User Guide

Industrial Semi-Metal USB

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide

Advanced 4-Port DVI-I Secure KVM Switch

Advanced 2/4-Port DisplayPort Secure KVM Switch

2 Welcome and Congratulations

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

D2H 4P Duo. User Manual. 8-Port DisplayPort in, 2-Port HDMI out, 4K Ultra-HD KVM Switch with USB and Audio

Transcription:

F1x3L Fiber Optic Tap LC CUSTOMER SUPPORT INFORMATION To order or for a technical information support: Phone: +33 3 88 10 18 30 or Fax: +33 3 88 10 18 35 Mail order: COMCRAFT 17A, rue des Frères Lumière 67201 Eckbolsheim - France Website: www.profitap.com E-mail: info@profitap.com

Index pages 1. General Information 3 2. Installation 4 3. Rack Mount Modules 5 4. Fiber types 6 5. Additional information 7 6. Disclaimer / Warranty 8 www.profitap.com Page 2

F1x3L Fiber Optic Tap 1. General Information. The Fiber Optic Tap offers a perfect and cost effective solution to tap Networks for IDS (security), SNMP (management), RMON (remote) and Protocol Analysis. The unit is easy to install, fault tolerant, transparent to the Network. It monitors the communication between two Network devices and is designed for use in Ethernet, Fast and GigaBit Ethernet, ATM, SONET, FDDI Networks and more. It is alloptical and works at any data-rate. It has 1 quad LC connector for connecting Network devices plus 1 quad LC connector for connecting the Analyzer. The Tap will continue to pass information in the Network also when the Analyzer is taken away. It is compact and housed in a rigid metal enclose. It requires no electrical power. www.profitap.com Page 3

2. Installation. Connect the Fiber Optic Tap as shown above. The Tap works in Full Duplex as well as Half Duplex Mode. The information passes from one Network device to the other, the split rate decides how much is passed to the Analyzer: 50/25/25 split passes 25% to each Rx Analyzer s port, while 40/30/30 passes 30%. Note: Dirt increases connector loss and can in certain cases block the signal totally. Leave the dust caps on the device if not in use. Mount back the dust caps if the Analyzer is taken away. www.profitap.com Page 4

3. Rack modules. RM-Fiber Optic Tap The Fiber Optic rack modules are designed to fit, together with rack mount plates, in 19 inch rack Systems. The Rack modules plug easily in the rack mount plates. Rack mounted www.profitap.com Page 5

4. Fiber types. Maximum Insertion Loss (db) : 3.9/7.3/7.3 (split ratio: 50/25/25) 5.1/6.3/6.3 (split ratio: 40/30/30) Single Mode. Dual Wavelength 1310/1550nm www.profitap.com Page 6

5. Additional Information. Connectors: 2 x quad LC, Zirconia sleeve Operation temperature: -20 to 80 C Storage temperature: -25 to 85 C Operating Humidity: Approval: Enclosure: Dimensions (WxDxH): Weight: 90%, no condensing CE Metal, structured black oven painted 143 x 163 x 35mm 240gr www.profitap.com Page 7

Disclaimer The information in this document is subject to change without notice. The manufacturer makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. The manufacturer reserves the right to revise this publication and to make changes in the content hereof without obligation of the manufacturer to notify any person of such revision or changes. Warranty and Liability Comcraft warrants that this product is free from defects in material and workmanship at time of shipment. The warranty period is 2 years from the date of purchase. The standard 2 year warranty period may be extended at the time of order. Comcraft assumes no liability for products that have been subjected to abuse, modification, misuse, or if the model or serial number has been altered, tampered with, defaced or removed. Comcraft is not liable under any contract, negligence, strict liability or other legal or equitable theory for any loss of use of the product, inconvenience or damages of any character, whether direct, special, incidental or consequential (including, but not limited to, damages for loss of goodwill, loss of revenue or profit, work stoppage or malfunction) Copyright This publication, including all photographs and illustrations, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any of the material contained herein, may be reproduced without written consent of the author Trademarks The trademarks mentioned in this manual are the sole property of their owners. Rev 3.3 2014, Comcraft COMCRAFT 17A, rue des Frères Lumière 67201 Eckbolsheim France www.profitap.com +33 3 88 10 18 30 +33 3 88 10 18 35