Panduit Certified Installer. Fiber Certification Review

Similar documents
Polymer Coated Fiber Cable (PCF)

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

Fiber Optic and CAT 5-6 Installer Premise Cabling

Indoor Cable Application Note

FiberExpress Brilliance Connectors

OPTICAL CABLE & CABLE ASSEMBLY

FiberSolutions. Fiber Optic Cable & Assembly Solutions

Course Outline Cover Page

Product Bulletin PB 308

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

Disadvantages of Fiber-Optic Cabling

Product Data Sheet. SC Thead-Lock Connector Assembly Instructions. Page 1 of 5 QUALITY FIBER COMPONENTS, EQUIPMENT, & SUPPLIES

Advanced Fiber Optic Connector Installation

A COMPARISON OF PRE-POLISHED CONNECTORS VS. FUSION-SPLICED PIGTAILS AS FIELD TERMINABLE SOLUTIONS

Fiber Optical Cabling Infrastructure Offer

Emerging Fiber Termination Solution

Fiber Optic Technician - Outside Plant (FOT-OSP) Course Description. Certification(s) Students Will Learn. Splicing Overview & Testing Outside Plant

Plug & Play Universal Systems

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

Copper Riser And Intrabuilding Cabling

Optical Fiber Assemblies

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

Basic Fiber Optic Concepts

Instruction Manual R&M Connectors. R&M Fiber Optic Components. System security for future requirements. Version 2.4

Fiber Termination Where we ve been and where we re going. Lylette Macdonald, RCDD Legrand Ortronics

Product Selection Guide

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Fiber Optical Cabling Infrastructure Offer

Fiber Optical Cabling Infrastructure Offer

Alternative Energy Solutions

Base 8 Plug & Play. Fiber Solutions

Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling.

Pretium EDGE Solutions Trunk Cable, 50 µm multimode (OM3)

OptiCam 2. Terminating OptiCam Connectors Using OptiCam 2 Termination Tool

Splice Trays An Evolant Solutions Product

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

Fiber Optic System. Fiber Optic System. Fiber Optic Rack Mount Solutions

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

CONNECTOR SOLUTIONS. FASTConnect FUSEConnect Field Master

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CONNECTORS, FIBER OPTIC, SINGLE FIBER, SMALL FORM FACTOR, LC TYPE

Pretium EDGE FX Solutions

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

Tarleton State University. Specifications

TABLE OF CONTENTS 1. GENERAL PRECAUTIONS...3

Description and Assembly Instructions

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

OPTICAL FIBER INTRODUCTION

Pretium Rack-mountable 1U Housing Hardware

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Fiber in Data Centers What s Next? Srinivasan B, RCDD

P R O D U C T C AT A L O G T ALOG

Plug & Play Universal Systems

Hands-On Outside Plant Intro-Level Technician

FIBRE ENCLOSURES AND SPLICING ACCESSORIES

Siemon PON Fiber Cabling Solutions

Mini Wall-mount Building Terminal (WBM)

3M Telecommunications. Solutions for Networks. Solutions. for Enterprise Networks

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

EDGE Solutions Trunk Cable, OM4, Low- Loss, MTP to MTP, 12 fibres

The interface ports are selectively enabled based on their functions in the system management versus non-management.

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories

Field Testing Installed Optical Fiber Cabling. Field Testing Installed Optical Fiber Cabling JUNE 2010 WHITE PAPER JUNE 2010

Network Construction Guide Specification Telecommunications Infrastructure Standards V 2.6

SUMITOMO SPECIFICATION. FutureFLEX. Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

SD Splicing Cassette

1 of 5 12/31/2008 8:41 AM

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

A wide range of connectors are available to fit very specific needs.

barpa Values Website & Social Network

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

Items Dimension(WxDxH) Max.Capacity Mounting P-FDB8 181X45X207mm 8 ports & splice Pole/Wall P-FDB16 220x80x300mm 16 ports & splice Pole/Wall

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

FAS-NET MPO Solution. Benefits of FAS-NET MPO Fiber Optic Solution:

13-SDMS-01 REV SDMS-01, REV.00 SEC DISTRIBUTION MATERIALS SPECIFICATION DATE: G

Fiber Optic Technology 101. Principles and Advantages. When is fiber the ideal choice For your network? I n s c a p e D a t a C o r p o r a t i o n

March 2018 OM1 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OM4 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OS2 SINGLEMODE DUPLEX FIBRE OPTIC CABLE 500M

CSI SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING Communications Optical Fiber Backbone Cabling Page 1

Optical Fiber Premises Standards News & Trends

ELECTROSÓN. Data Sheet. HFBR-RXXYYY Series (POF) HFBR-EXXYYY Series (POF) Plastic Optical Fiber Cable and Accessories for Versatile Link

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

INDUSTRIAL TRAY CABLE PRODUCTS

C o n n e c t o r s C h a p t e r 183

Expanded SECURE Connector Product Line Includes MPO and LC Interfaces

Cabling Solutions Data Center & Local Area Networks

Fibre Enlosures and Splicing

UniCam High-Performance Connectors, Multimode and Single-Mode

UniCam Connector Installation Tool Kits

EDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres

FLAME RETARDANT RIBBONIZED FIBER

Field-Installable Fiber Optic Connector Tool Kits

Cables Fiber & Copper

Design. Application. All closure sizes are available with three different fiber management systems included in the pack.

LightStack. Ultra High Density Plug & Play System PATENT PENDING

Rack Mount Interconnect Center (RIC3)

Transcription:

Panduit Certified Installer Fiber Certification Review

2 What does the cleave tool do? A. Breaks the glass cleanly B. Cuts the glass cleanly C. Scores the glass cleanly D. Shatters the glass cleanly Breaks the... Cuts the g... Scores the... Shatters t...

3 Which of the following describes Panduit's concerns for requiring cabling technicians to complete this training? A. Best practices are utilized for installing optical fiber cabling B. Installers have an understanding of industry standards C. Cabling is installed in a neat and workmanlike manner D. All of the above Best pract... Installers... Cabling is... All of the...

4 Which type of optical fiber has a core diameter of approximately 9 um? A. Multimode B. OM 3 C. Single Mode D. Interconnect Multimode OM 3 Single Mode Interconnect

5 What should be done first when terminating an optical fiber connector? A. Cleave the glass B. Polish the end face of the connector C. Slide the connector boot onto the fiber D. All of the above Cleave the... Polish the... Slide the... All of the...

6 Determining the Pathway and Laying the Cable are the two main stages of installing a fiber cabling system. A. True B. False True False

7 How much buffer should be stripped at one time when using a strip tool? A. 0.25 inch B. 0.50 inch C. 1 inch D. 2 inches 0.25 inch 0.50 inch 1 inch 2 inches

8 When installing optical fiber cabling, the strength member should be removed and the glass strands are wrapped around a pull rope for the cable to be pulled through the pathway. A. True B. False True False

9Which TIA standard defines the administration standard for the telecommunications infrastructure of commercial buildings? A. TIA 568-B.2 B. TIA 568-B.3 C. TIA 569 D. TIA 606 TIA 568-B.2 TIA 568-B.3 TIA 569 TIA 606

10 Panduit OptiCam connectors can be reterminated twice. A. True B. False True False

11 Effective cable management allows for quick and easy moves, adds, and changes. Which of the following are benefits of effective cable management? A. Protects cables from crushing and pinching B. Provides aesthetically pleasing appearance C. Assures bend radius control for the cables D. All of the above Protects c... Provides a... Assures be... All of the...

12 Cables should be pushed through a pathway if it cannot be laid in a cable tray. A. True B. False True False

13 What are the two common core diameters for multimode fiber? A. 9 um/50 um B. 50 um/62.5 um C. 9 um/62.5 um D. 9 um/125 um 9 um/50 um 50 um/62.5... 9 um/62.5 um 9 um/125 um

14 Which of the following must be considered when establishing a loss budget for testing optical fiber cabling installations? A. Number of connectors B. Number and type of splices C. Cable attenuation coefficient D. All of the above Number of... Number and... Cable atte... All of the...

15 When polishing optical fiber connectors with a puck on a polishing pad, the puck should be moved in a "figure 8" motion to assure even pressure on the glass. A. True B. False True False

1650 um fiber has become more popular in recent years because it works better with light sources. A. LED B. VCSEL C. Laser D. Infrared LED VCSEL Laser Infrared

17 What tool is used to assure the field fiber is properly mated in a pre-terminated fiber connector? A. Strip tool B. Cleave tool C. Visual Fault Locator (VFL) D. 5 um polishing film Strip tool Cleave tool Visual Fau... 5 um polis...

18 What is the first stage of polishing when terminating Standard Field Polish connectors? A. Air polishing B. Polish with 1 um diamond polishing film C. Polish with wet 5 um polishing film D. Polish with dry 5 um polishing film Air polish... Polish wit... Polish wit... Polish wit...

19 Which of the following safety precautions must be observed when terminating optical fiber connectors? A. Wear safety glasses B. Dispose of scrap pieces of glass in an appropriate manner C. There should be no food or drinks in the termination area D. All of the above Wear safet... Dispose of... There shou... All of the...

20 fiber optic cables are 50/125 um fibers that are manufactured with a special process that allows the cable to perform better for transmitting 10 Gigabit Ethernet signals for up to 300 meters. A. OM1 B. OM2 C. OM3 D. OS1 OM1 OM2 OM3 OS1

21 If pulling cable in stages, cable slack should be A. Piled in a figure 8 pattern B. Laid in a cable tray C. Be attached to a pull string D. All of the above Piled in a... Laid in a... Be attache... All of the...

22 What is the maximum pulling tension for installing optical fiber cable? A. 25 lb/ft B. 100 lb/ft C. Consult cable manufacturer recommendation D. 500 lb/ft 25 lb/ft 100 lb/ft Consult ca... 500 lb/ft

23 Backbone cables should be labeled to identify the location of where the cable is terminated at each end. A. True B. False True False

24 What type of Isopropyl Alcohol does Panduit recommend be used for cleaning during optical fiber termination? A. 5 Alcohol B. 7 Alcohol C. 9 Alcohol D. 12 Alcohol 5 Alcohol 7 Alcohol 9 Alcohol 12 Alcohol

25Typically multimode cable have an outer jacket and the connector bodies are colored. A. Blue, Ivory B. Orange, Ivory C. Yellow, Blue D. Red, Blue E. Agua, Ivory Blue, Ivory Orange, Iv... Yellow, Blue Red, Blue Agua, Ivory

26 What is the first thing you should do when testing fails? A. Check if the connector was properly polished B. Remove the connector from the FAP and inspect it with a microscope C. Make sure the transmit at one end goes to the receive at the other end D. All of the above Check if t... Remove the... Make sure... All of the...

27 When using field test equipment, a reference measurement must be established and recorded before testing any cabling links. A. True B. False True False

28Interconnect cabling is usually two strand fibers in either a simplex, duplex or cable configuration. A. Zipcord B. Ripcord C. Buffered D. Unbuffered Zipcord Ripcord Buffered Unbuffered

29 A Small Form Factor optical fiber connector terminates two strands of fiber in the same footprint as an RJ45 copper connector. A. True B. False True False

30 What type of optical fiber splicing requires a special machine that melts the ends of two fiber strands to form one solid strand? A. Mechanical splice B. Fusion splice C. Butt splice D. Tap splice Mechanical... Fusion spl... Butt splice Tap splice

31 How much fiber slack is required when terminating optical fiber at a faceplate or inside of a fiber optic enclosure? A. 1 foot B. 1 meter C. 3 meters D. 5 meters 1 foot 1 meter 3 meters 5 meters

32 What are the two fundamental organizations that develop the cabling standards that are implemented worldwide? A. ISO and NEC B. TIA and UL C. ISO and TIA D. NFPA and CELEC ISO and NEC TIA and UL ISO and TIA NFPA and C...

33 Any industry standard anaerobic adhesive or polishing film may be used when terminating Panduit Standard Field Polish connectors. A. True B. False True False

34Interconnect cables are used for small count cabling applications. A. Vertical B. Horizontal C. Backbone D. Special Vertical Horizontal Backbone Special

35 Fiber backbone cables must be tested in both directions at one wavelength. A. True B. False True False

36 What are the two components of the glass in a strand of optical fiber? A. Jacket/Strength member B. Core/Cladding C. Buffer/Acrylate coating D. Acrylate coating/ Strength member Jacket/Str... Core/Cladd... Buffer/Acr... Acrylate c...

37 How should consumable items be replaced for a Panduit fiber termination kit? A. Order a new termination kit B. Order a competitor kit C. Order a refurbishment kit D. Items do not need to be replaced Order a ne... Order a co... Order a re... Items do n...

38 What is used to mate fiber terminations and patch cords in faceplates or enclosures? A. Visual Fault Locator (VFL) B. Fiber Adapter Panels (FAPs) C. Cable Ties D. Duplex Adapters Visual Fau... Fiber Adap... Cable Ties Duplex Ada...

39There are two different types of OSP cable, indoor/outdoor and. A. Buffered B. Unbuffered C. Loose tube D. Tight tube Buffered Unbuffered Loose tube Tight tube

40 How much optical fiber cable slack is recommended for a Telecommunications Room? A. 1 meter B. 3 meters C. 5 meters D. 10 meters 1 meter 3 meters 5 meters 10 meters

41Loose tube OSP fiber optic cable typically must be terminated within meters of entering the building, unless it is routed in conduit. A. 8 B. 10 C. 15 D. 20 E. 50 8 10 15 20 50

42 What type of optical fiber cable should be installed for intra-building backbone cabling? A. Interconnect Cable B. Outside Plant Cable C. Distribution Cable D. Loose Tube Cable Interconne... Outside Pl... Distributi... Loose Tube...

43 Extra slack must be provided when terminating optical fiber cabling. A. True B. False True False

44 Which TIA standard defines the requirements for optical fiber cabling installations for commercial office buildings? A. TIA 568-B.2 B. TIA 568-B.3 C. TIA 569-A D. TIA 607-A TIA 568-B.2 TIA 568-B.3 TIA 569-A TIA 607-A

45 Cable slack cannot be stored in an enclosure. A. True B. False True False

46 Match each cable to its correct type. 1. Duplex 2. Simplex 3. Zipcord 4. Buffered A. A-2, B-1, C-4 B. A-2, B-1, C-3 C. A-2, B-3, C-1 D. A-1, B-2, C-3 A-2, B-1,... A-2, B-1,... A-2, B-3,... A-1, B-2,...

47 The Aramid Yarn should be secured to provide strain relief for fiber cable entering an enclosure if no other means of strain relief is provided. A. True B. False True False

48 Which of the following types of connectors are manufactured by Panduit? A. Standard Field Polish B. Opti-Crimp C. OptiCam D. All of the above Standard F... Opti-Crimp OptiCam All of the...

49 The outside diameter for the cladding for both single mode and multimode optical fiber is 125 um. A. True B. False True False

50 What tool is used for terminating OptiCam connectors? A. FCRP5Crimp Tool B. OptiCam Terminations Tool (OCCT) C. FVFLKIT D. FPAD polishing pad FCRP5Crimp... OptiCam Te... FVFLKIT FPAD polis...

51A pathway initially needing to service 10 work areas should be sized to accommodate cables. A. 10 B. 20 C. 25 D. 30 E. 40 F. 50

Participant Scores