IBA-7612 Programming Instructions

Similar documents
7612 Programming Instructions

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

AYC-Ex5/T65 Family Convertible Backlit Proximity & PIN Readers/Controllers Installation and Programming Manual

AC-S/T43 Family Anti-Vandal Piezoelectric PIN Standalone Controller Installation and Programming Manual

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

AYC-E/Q/T60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

DG-800 Stand-Alone Proximity Reader Instruction Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Instruction Manual AC-E75. Ultra-Slim PIEZO 2 x 6 Matrix 500-User Outdoor Secured Access Control Unit. AC-E75 Ultra-Slim Secure Keypad IM Page 1

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Waterproof. Keypad/Reader/Controller

Digital Keypad Introduction

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

RFID/Digital Access Control Keypad

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Installation and User Manual

RBR-SB-KTZ001 LAR 2. User Manual

EL-ST100 KEYPAD CONTROLLER

DOLXFD1000B. Waterproof Access Control/Reader

1. Product Specification

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Stand-alone Proximity Access Control

Installing Keypad and Backplate

W3-H Waterproof Keypad/Reader/Controller

INSTALLATION INSTRUCTIONS E77 SERIES STANDALONE ELECTRONIC LOCKSET

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

CM-110SK Standalone Keypad Installation Instructions

VIDI-AC-2CS Access Controller/ Reader

AYC-x6355 Family CSN SELECT Smart Card Readers/Controllers Installation and User Manual. Models: AYC-H6355 AYC-M6355

User Manual. PCKeypad Wireless Keypad

-DTZ001- Stand-Alone Proximity Access Control. User Manual

2000 Series e/em Style Keypad Installation and Programming Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

W3-M. Metal waterproof standalone access control/reader. User Manual

VIS-3200 / VIS-3201 User Manual

9212i INSTALLATION. Stand-Alone Keypad. Instructions

KP2000E/EM Series Style Keypad

Two Door Controller GEN-045

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Specifications: Features:

Single Door Standalone Access Control User Manual

CP150B Vandal & Weather Resistant Keypad Security Systems

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

installation quick guide integrated access control & environmental monitoring

User Manual. Split access control with intelligent secured power supply.

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Suprex RS-485 SPX-7500 Wired Reader-Extender

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

REX F-0-9 Standalone or Access Controller

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

SPX-7400_SPX-7410_MAN_161028

SK-1011-SQ Digital Access Keypad with 5A Relay Output

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

Installation Instructions 4291 and 4292 Keypads

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Fingerprint Access Control F1. User Manual

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

BC Digital Keypad. User Manual

AS Keypad User Manual

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

CM-500 SK 500 USER CODES KEYPAD

M A C 3 Wind Speed Alarm & Controller

212iL Rev. 1.1

ACCESS CONTROL SYSTEM

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

PRT12 v1.2 RFID/PIN Outdoor Access Terminal

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

Proximity Card and Pin Reader Installation Manual

MCX402DR-BRD I/O expander. Operating Manual

PT DC 70 MBPT. Vandal Resistant, Back-Lit Weatherproof, Access Control. Keypad. Notes. Keypad. Programming Instructions

DG Series. Access Control Proximity Readers DG-160 DG-800

MAC3 Wind Speed Alarm & Controller. Installation Instructions

HSY-S209 EM Metal waterproof access control system User Manual

K44 Code lock. Technical manual

IPassan Installation guide

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

Universal Z-Wave Key Pad

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

CA-A480-A Elevator Controller. Reference & Installation Manual

Transcription:

IBA-7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards IBA-7612 is a vandal resistant proximity card and keypad access control unit suitable for external applications. The unit accepts up to users and provides entry via the use of proximity cards and/or pin codes. Equipment provided The following is provided as part of every IBA-7612 package: IBA-7612 Access Control Unit Installation Kit Installation and Operating Instructions Additional Equipment Required Electric lock Strike Mechanism Fail Safe (power to lock) or Fail Secure (power to open) Power Supply with Backup Battery 12VDC (From a Regulated Power Supply) Request to Exit (REX)Button Normally Open Type-Switch is closed when pressed. Technical Specification Eletrical Characteristics Operating Voltage: 12VDC From a Regulated Power Supply Input current: Standby: 40mA Not including attached devices Max: 130mA Not including attached devices Outputs: Lock Strike Relay From C, 5A Auxiliary Relay From C, 5A LockStrike Control Output Collector Open Output (25mA) Auxiliary Control Output Collector Open Output (25mA) Envirmental Characteristics Operating Temperature: 0 to 5%(Non-Condensing) Suitble for outdoor use Mechanical Characteristics Dimentions:120L*76W*27Hmm Weight:0.9ibs(410g) Range also depends on electrical environment and proximity to metal. Key Features Here are some of the IBA-7612's key features: Built-in Proximity Card Reader(125KHZ ASK Modulation) Built-in Keypad for PIN Code entry Auxiliary Input & Auxiliary Output Eight Auxiliary Modes including: Door Ajar Forced Door Shunt Door Monitor Normal/Secure Internal Buzzer Two Status/Programming Interface LED'S Two Modes of Operation Normal Mode Secure Mode Three User Levers Normal User Secure User Master User Four Open door mode 4 digit Pin Code 4 digit Pin Code & EM Card 4 digit Pin Code & 1.4 digit Pin Code EM Card & EM Card Inputs: REX N.O.,Dry Contact Auxiliary Input(In/Monitor) N.C.,Dry Contact in Monitor Mode N.O.,Dry Contact Input Mode Construction

code search Feature that helps make maintaining user codes easier. Built-in Case and Back Tamper Bell, Chime, Siren, Battery Backup, Tamper Output features available with IBA Power Supplies. Programmable Siren Time. Programmable Lock Strike Release Time. Wiring Instruction Mounting the IBA-7612 Controller 1)Before starting, select the location to mount the IBA-7612 Controller. This location should be at shoulder height and on the same side as the door handled. 2) Drill holes into the back of the metal according to how you want to mount the IBA-7612 Controller. (See explanation and diagram below). Operation Introduction Normal, Secure,& Master Users The IBA-7612 accepts up to 500 users and provide entry via two codes: Memory Slot 1(Primary code) and Memory Slot 2(Secondary code). A. Mounting hole B. 4 blind holes for Auxiliary Installation 3) Drill the exit/entry holes for the wiring. (Shown marked as C) 4) Pass the wires through the exit/entry holes and attach them to the controller corresponding terminal blocks as shown in the below diagram. Connecting the wires to the corresponding terminal blocks There are three user levels: Normal User A Normal User only has a Primary Code and is only granted access when the IBA-7612 is in Normal Mode. Secure User A Secure User must have a Primary and Secondary code programmed, the two codes must not be the same. the Secure User can gain access when IBA-7612 is in its two Modes of Operation. In normal Mode the Secure User must present both their Primary and Secondary Codes in order to gain entry. 5) Screw the IBA-7612 Controller back cover to its mounting location. 6) Return the front cover by using the supplied security screw in the controllers accessories kit. An L-Shapped tool is provided for use when tightening the security screw. Master User A Master User must have both Primary and Secondary code programmed with the same Proximit Card or PIN code. The Master user ca gain access during any Mode of Operation by presenting their Proximity Card or PIN CODE to the controller.(the master user is convenient but is less secure than a Secure User). Primary code and Secondary code Primary code: 1)Only can be used separately under the mode of Normal 2)Can't be same with the other codes

Secondary code: 1) Must match the corresponding Primary Code in Secure Mode 2) Don't be same with the System Code (i.e. Factory settings), but the different users can set the same than 10 seconds. The master users can entry either primary code or secondary code (EM card). Changing from Normal Mode to Secure Mode Enter the Secure Mode, Press # Secondary code. Normal Mode and Secure Mode 1)Normal Mode: Normal Mode is the Default Factory Setting Mode, all the normal users, secure users and master users can entry with Primary code or EM Card. 2) Secure Mode Only secure users and master users can entry can entry in this mode.the secure users enter the Primary and Secondary Code to entry, but the time interval should be less Changing from Secure Mode to Normal Mode Enter the Secure Mode,Press # Reference: The default factory setting for the Program Code is 3-8-3-8 Programming Introduction You can enter the Programme mode only when you are under the Normal mode How to enter the Programme mode 1) Press # for 2 seconds 2) Enter your 4-digit programme code programming Menu Menu Factory Menu Description Number Settings 1 Chang Open Code 2580 2 Chang Auxiliary Code 0852 3 Chang Program Code 1234 4 Chang Secure Code 3838 6 Chang Door Release Time 0005 7 Define Auxiliary Input/outputs Enroll Proximity Cards, PIN Code or both 8 Delete Proximity Cards Or PIN Code 9 Code Assignment with Strike/Auxiliary 0 Return to Default Factory Setting Exit Programme mode Press # for 2 seconds(the door LED will be off, The Mode LED will turn green) NOTE:The display Led light will have different change if you press different keys. i.e Press 1 the Mode LED will turn red and Door LED will turn green. Press 2 the Mode LED will turn orange and Door LED will turn green. Press 3 the Mode LED and Door LED all will turn green. Press 4 the Mode LED will flash red and Door LED will turn green. Press 6 the Mode LED and Door LED all will turn green. Press 7 the Mode LED will turn down and Door LED will turn orange. Press 8 the Mode LED will turn red and Door LED will turn orange. Change the System code Change the Open door code 1) Enter Program mode 2) Press 1 to enter menu 1 3) Enter 4-digit Number Change the Auxiliary code 1) Enter Program mode 2) Press 2 to enter menu 1 3) Enter 4-digit Number Change the Program code 1) Enter Program mode 2) Press 3 to enter menu 1 3) Enter 4-digit Number

Change the Secure code 1)Enter Program mode 2)Press 4 to enter menu 1 3)Enter 4-digit Number Change the Lock Strike Release Time and Tamper Siren Time 1) Press # for 2 seconds. 2) Enter the programe code. 3) Press 6. 4) You will now need to enter a 4 digit number. The first digit will tell the IBA-7612 if it is to work with a fail safe or fail secure lock. The second digit represent the Tamper Sire Time, the last 2 digits will tell the IBA-7612 how long it will keep the lock activated. For the first digit: 0 is for fail safe locks is for fail secure locks For the second digit: Tamper Sire Time, enter any number from 1 to 9 mins For the last 2 digits: 01= 1 second 99= 99 seconds So if we want to set the lock activation time for 7 seconds and work with a fail secure lock we would set the 4 digits to 1007. Defining Auxiliary Inputs/Outputs 1)Press # for 2 seconds. 2) Enter the programe code. 3) Construct the 4-digit code using the instructions below: 2??? Auxiliary Mode Auxiliary Setting Auxiliary Mode Quick Reference Guide Auxiliary Auxiliary Output Aux. Auxiliary Settings Auxiliary Input Mode Activated On Relay (All times and delays are in seconds) 0 REX-2 Valid Code or REX-2 N.O. 01 to 99 Aux. Relay Release Time 1 Normal/Secure Valid Code N.O. 00 Aux. Relay Toggles 2 Normal/Secure Bell Button N.O. 3 Normal/Secure Tamper Event N.C. 01 to 99 Aux. Relay Release Time 00 Aux. Relay activated by Tamper 4 Normal/Secure Direct Shunt N.O. 00 to 99 Shunt Time 5 Door Monitor Shunt N.C. 00 to 99 Maximum Shunt Time 6 Door Monitor Forced Door N.C. 00 to 99 Forced Delay 7 Door Monitor Door Ajar N.C. 00 to 99 Ajar Delay Enrolling Primary & Secondary Codes Two methods (Standard Method & Code Search Method): Standard Method: Enrolling Primary Codes 2) Press 7 4) Enter 4-digit user Code or Present the Card Enrolling Secondary Codes(only when the user has his own Primary code) 2) Press 7 4) Enter 4-digit user Code or Present the Card Code Search Method: Enrolling Secondary Codes(only when the user has his own Primary code) 2) Press 7 4) Enter Primary 5) Enter 4-digit user Code or Present the Card Deleting Primary & Secondary Codes Two methods (Standard Method&Code Search Method): Standard Method: 2) Press 8 4) Enter 4-digit user Code or Present the Card 5) Enter program code to ensure

Code Search Method: 2) Press 8 4) Enter Primary Code 5) Enter program code to ensure Lock Strike and Auxiliary Relay Code Assignment Two methods Standard Method: 2) Press 9 3) Enter 3-digit user slot that you want to assign a code to 4)Enter the assignment digit for the current User Slot 1 assigns the Lock Strike Relay only 2 number assigns the Auxiliary Strike Relay only 3 assigns the Lock Strike and Auxiliary Relay Code Search Method: 1)Enter the program mode 2)Press 9 3)Enter 000 4)Present the EM Card or enter the 4-digit for the Current User 1 assigns the Lock Strike Relay only 2 number assigns the Auxiliary Strike Relay only 3 assigns the Lock Strike and Auxiliary Relay Return to Factory Default Settings warning: You must be very careful before using this command! Doing so will erase the entire memory which includes all User and Special Codes, and return all codes to their factory default settings. 1) Enter Programming Mode 4-digit Secure Code 2) Press 0 to enter Menu 0 3) Enter Programming Code to confirm Replacing a lost Program Code Note: The IBA-7612 must be in Normal Mode otherwise this will not work. Make sure that the Mode LED is green before proceeding. 1) Remove power from the IBA-7612 2) Press the REX button 3) Apply power to the unit with REX button pressed 4) Release the REX button 5) You now have 15 seconds to program a new Program code into the unit using the initial default code 1-2-3-4, before the controller reverts to the existing code. Replacing a lost Secure Code Note: The IBA-7612 must be in Secure Mode otherwise this will not work. Make sure that the Mode LED is red before proceeding. 1) Remove power from the IBA-7612 2) Press the REX Button 3) Apply power to the unit with REX button pressed 4) Release the REX Button 5) You now have 15 seconds to program a new Secure code into the unit using the initial default code 3-8-3-8,before the controller reverts to the existing code. Operations: 1)Enter Default Secure Number3-8-1-8 2)Enter # to return to Normal Mode 3)Press # for 2 seconds 4)Enter Default Programme Code 1-2-3-4 5)Press 4 6)Enter your new Appendix Memorandum of Users Contents First Second Third User name change change change User Number Program code 1234 User name Secure Code 3838 User Number Open code 2580 User Number Open Time 5s

LED Display Case Normal condition Secure condition Enter program ode Release the Lock Tamper Mode LED DOOR LED Green Red Green Red Case Sound display Sound Description Valid Press One short deep deep Valid change code Three short deeps deep deep deep Valid Reader One short deep deep Invalid Code One long deep deep Invalid Program One long deep deep Operation Glossary First Press # for 2 seconds Mode LED will turn down and Door LED will turn red Second Enter programme code (default 1234) Mode LED will turn down and Door LED will turn green Third Open Code Aux Code Program Code Secure Code Open delay time Enroll a (default2580) (default0852) (default1234) (default1234) (default 4secs) new employee Delete a employee Press 1 Press 2 Press 3 Press 4 Press6 Press 7 Press 8 Enter your new 4-digit Code 001-500 user Enter delete user Two choices NO. NO. Eight choices Enter your new 4-digit Code 1) 00xx 00=NO xx=01-99s* 2) 10yy Present Card or Enter 3-digits Same as above Enter program code to confirm ok 10=NC or finish by yy=01-99s* pressing # key Return to N-M after three deeps M-L turn red D-L turn down Return to N-M after a deep Return to N-M M-L turn green M-D turn down Result Set a new Open Code Set a new Aux Code Set a new Program Code Set a new Secure Code Set Open delay time Enroll a new employee Delete a employee Note: M-L = Mode LED D-L= Door LED * s= Seconds N-M= Normal Mode Mode by s u c h i n k o For more application information please visit our website www.suchinko.com.