This manual provides information on the Extron MDA 4V EQ video distribution amplifier and discusses how to install and operate them.

Similar documents
P/2 DA2xi User Guide. FCC Class A Notice. Specifications Availability. Features. Mounting the P/2 DA2xi. Attention:

AXI 016 Setup Guide. Disconnect Power and Mount the AXI 016. Rear Panel Connections. C EXP Input Port and LED D EXP Thru Port and LED

AXI 22 AT D Setup Guide

OUTPUT SMD 202 AUDIO INPUT AUDIO. G 3.5 mm, 5-pole captive screw connector for analog stereo. audio output

AXP 64 C AT Setup Guide

VSW 2VGA A User Guide

AXP 50 C AT Setup Guide

HDP 101 4K User Guide

AXP 64 C AT Setup Guide

SOURCE 1 MIC PROGRAM RESET. ACP 100 Front Panel without PlasticFaceplate

USB Plus Matrix Controller Setup Guide

EBP US Gang Button Panels Setup Guide

MLC Plus 84 D Setup Guide

MLC Plus 50/100/200 Series Setup Guide

C D. ebus Button Panel EU and MK Series Setup Guide

Headend Unit (HEU) Quick Installation Sheet

ControlLogix Redundant Power Supply Chassis Adapter Module

IPCP Pro 350DR, IPCP Pro 355DR Setup Guide

Five-Band Remote Access Unit (RAU5x) Quick Installation Sheet

FlexArmor 24V dc Sinking Input Modules

MCG Surge Protection

ArmorBlock MaXum 4 Output Module Series B

ebus Button Panel Decorator-Style Series Setup Guide

Replacing the Quantum Ultra Disk Drives and System Board Computer Assembly

TLP Pro 525M, 725M, and 1025M Series Setup Guide

FLEX I/O EtherNet/IP Adapter Module

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

IPCP Pro Series Setup Guide

ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate

VI 021 S-DIAS VARAN Control Module

ArmorBlock MaXum 8 Input / 8 Output Module Series B

1 PORT HARDENED SERIAL SERVER

2201 Rack Chassis User Manual

CP-100. Owners And Installation Manual

Sun Rack Cabinet Extension Installation Guide

LVB-2 INSTRUCTION SHEET. Leakage Current Verification Box

Installation Instructions RF5010 and RF5210

Now with Picture Memory

Intelligent Channel Bank Shelf

FortiFone QuickStart Guide for FON-175

ISE 021 S-DIAS Interface Module RS232 / RS485

User's Guide. MobileLAN power

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

ControlLogix DC (10-30V) Isolated Output Module

ICA 012 S-DIAS Interface Module CAN

Power Supply (48Vdc, 2.5A)

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

Cable Management Guide

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

Sun Fire System Controller Board, Version 2 (Enhanced Memory) Installation Guide

H3C S12500 Routing Switch Series

WaterStopper User Instruction Setup and Troubleshooting guide

INSTALLATION INSTRUCTIONS

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

ControlLogix DC ( V) Electronically Fused Output Module

RO 051 S-DIAS Relay Output Module

EcoView 8 DO Module Installation and Commissioning

FLEX Integra 4 Input Module

Installation and Maintenance

OUTDOOR WIRELESS ACCESS POINT

1769 Compact I/O Communication Bus Expansion Cables

User guide. Bluetooth Keyboard BKB10

AgileMesh Node Configuration Guide

ControlNet PCI Communication Interface Card

Installation Instructions RF5010 and RF5210

INSTALLATION AND OPERATION MANUAL XDS SERIES FULL RANGE PASSIVE LOUDSPEAKERS XDS10 XDS12 XDS212 REV 2.0

Installing the PSU for the S50 and S50N

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Sun Fire High-End Server Systems Hold-down Kit

Cisco ONS CL Shelf Assembly Hardware

Infosystem Remote Touchscreen Installation Instructions

FLEX Integra 2 Input/2 Protected Output Module

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

QUICK INSTALL GUIDE READ ME FIRST XWC Package Contents: XWC-1000 Wireless Controller. Rack Mount Kit. Power Cord. Wireless Controller

PS 101 S-DIAS Power Supply Module

Quantum Ultra Videowall Processor Setup Guide

Quantum Ultra Videowall Processor Setup Guide

Series 3700 Screw Terminal Assemblies Installation Instructions

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

2 Mesa Ethernet Dock User s Manual

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Dolphin CT50 Non-Incendive

ControlLogix RTD Input Module

G12/G12x USER S MANUAL

MONITORING INTELLIRACK USER MANUAL

R SERIES INSTALLATION GUIDE

SI 021 S-DIAS SSI Interface Module

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

Programming Overview DOOR PRGM SET

Quick Start Guide. Arista Networks Series 1 RU (Gen 3) Data Center Switches. PDOC

SE 051 S-DIAS Splitter Ethernet

TP7 7 Touch Panel User Interface Quick Install Guide

KP7 Keypad Quick Install Guide

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

ControlLogix Isolated Analog Voltage/Current Input Module

to 48V DC Power Supply

Transcription:

MDA V EQ USER GUIDE Introduction About this Manual This manual provides information on the Extron MDA V EQ video distribution amplifier and discusses how to install and operate them. About the MDA V EQ Mini Distribution Amplifier The Extron MDA V EQ are compact composite video mini distribution amplifier with individual output gain and equalization controls that compensate for different cable lengths for each output. The MDA V EQ is also a line driver, able to handle 1000 feet of Extron Mini HR cable. MDA V EQ One input, four outputs, composite video with equalization and gain controls for each output Features Input: One female BNC connector Output: Four female BNC connectors and a passive loop-through 150 MHz (- db) video bandwidth, fully loaded Variable gain and EQ adjustments Independent gain and EQ control per output Video loop-through 1U, quarter rack width metal enclosure External Extron Everlast power supply included Provides worldwide power compatibility with high demonstrated reliability and low power consumption Installation and Operation Mounting the MDA V EQ The MDA V EQ mini distribution amplifier can be set on a table or mounted on a rack shelf, see the accessory options at www.extron.com Tabletop Use Four self-adhesive rubber feet are included with the MDA EQ. For tabletop use, attach one foot at each corner of the bottom side of the unit and place the unit in the desired location. 1

MDA V EQ USER GUIDE (Continued) Rack Mounting For optional rack mounting, mount the MDA EQ on one of the rack shelves or projector mounting brackets listed above. On the standard 9.5 inches deep rack shelves, the unit can be mounted in one of four locations to the rear of the rack or in one of four locations to the front of the rack. 1. If rubber feet are installed on the bottom of the MDA, remove them. 2. Mount the MDA EQ on the rack shelf, using two -0 x /16 screws in opposite (diagonal) corners to secure the unit to the shelf.. Install blank panels or other units on the rack shelf. 1U Universal Rack Shelf 1/2 Rack Width Front False Faceplate 1/ Rack Width Front False Faceplate 6" Deep Rack Shelf 1/2 Rack Width Front False Faceplate Both front false faceplates use 2 screws. Front false faceplate uses 2 screws. Use 2 mounting holes on opposite corners. (2) -0 x /16" Screws Use 2 mounting holes on opposite corners. (2) -0 x /16" Screws Figure 1. Mounting an MDA V EQ on a Standard Rack Shelf Figure 2. Mounting an MDA V EQ on a 6-inch Rack Shelf Furniture Mounting To furniture-mount the MDA V EQ, use the optional mini under-desk mounting kit, as follows. Figure. Preparing the MDA V EQ for Under-desk Mounting 1. If rubber feet were previously attached to the bottom of the unit, remove them. 2. Attach the mounting brackets to the MDA EQ with the provided machine screws as shown in the previous figure.. Hold the unit with the attached brackets against the underside of the table or other furniture. On the mounting surface, mark the location of the bracket s screw holes.. Drill /2 (2 mm) diameter pilot holes, ¼ (6. mm) deep in the mounting surface at the marked screw locations. 5. Insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until slightly less than ¼ of the screw head protrudes. 6. Align the mounting screws with the slots in the brackets and place the unit against the surface, with the screws through the bracket slots. 7. Slide the unit slightly forward or back, then tighten all four screws to secure it in place. 2

Rear Panel Features and Cabling The following figures shows the back panel configurations of the MDA V EQ model. MDA V EQ POWER 12V 0.2A MAX 5 INPUT IN 1 HIGH Z 1 2 LOOP-THRU 75 Ohm OUTPUTS 2 Figure. MDA V EQ Rear Panel 1 Power supply connector 2 Passive Loop-Thru connector Toggle switch Output connectors, composite video 5 Input connector, composite video 1 Power supply connector Plug the external 12 VDC power supply into this 2-pin,.5 mm captive screw connector. The power supply is included with the unit. NOTE: The power connector on the rear panel is orange; however, the plug for the power cord may be either orange or blue. Either color plug can be connected to the rear panel receptacle. 2 Passive Loop-Thru connector Connect a monitor (optional) to this female BNC connector. Toggle switch Set this switch to HIGH Z if a monitor is plugged into the Passive Loop Thru connector. Setting this switch to 75 OHM simulates a monitor when none is attached to the Loop Thru connector. Output connectors, composite video Connect up to four MDA V EQ composite video monitors to these BNC connectors. 5 Input connector, composite video Connect a composite video input source to this BNC connector. Wiring the Connector WARNING: The two power cord wires must be kept separate while the power supply is plugged in. Remove power before wiring. AVERTISSEMENT : Les deux cordons d alimentation doivent être tenus à l écart l un de l autre quand l alimentation est branchée. Couper l alimentation avant de faire l installation électrique. 1. Cut the DC output cord to the length needed. 2. Strip the jacket to expose 0.2 inch (5 mm) of the conductors for the blue captive screw plug, or 0. inch (7 mm) for the orange plug. ATTENTION: The length of the exposed wires in the stripping process is critical. The ideal length is /16 inches (5 mm). Any longer and the exposed wires may touch, causing a short circuit between them. Any shorter and the wires can be easily pulled out even if tightly fastened by the captive screws. ATTENTION : La longueur des câbles exposés est primordiale lorsque l on entreprend de les dénuder. La longueur idéale est de 5 mm (/16 inches). S ils sont un peu plus longs, les câbles exposés pourraient se toucher et provoquer un court circuit. S ils sont un peu plus courts, ils pourraient sortir, même s ils sont attachés par les vis captives. NOTE: Stripping the wires to expose less than the recommended amount causes them to slide out of the connector too easily, even if they are tightly pinched by the captive screws.. Slide the leads into the supplied captive screw plug and lock them, using an Extron Tweeker (small screwdriver).. Use the supplied tie-wrap to strap the power cord to the extended tail of the connector. 5. To verify the power cord s polarity before connecting it, plug in the power supply with no load and check the output with a voltmeter.

A A MDA V EQ USER GUIDE (Continued) ATTENTION: The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/ NFPA 70, article 725 and the Canadian Electrical Code part 1,section 16. Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l électricité (National Electrical Code) ANSI/NFPA 70, article 725, et du Code canadien de l électricité, partie 1, section 16. The power supply shall not be permanently fixed to building structure or similar structure. La source d alimentation ne devra pas être fixée de façon permanente à une structure de bâtiment ou à d autres structures similaires. Power over Ethernet (PoE) is intended for indoor use only. It is to be connected only to networks or circuits that are not routed to the outside plant or building. L alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur uniquement. Elle doit être connectée seulement à des réseaux ou des circuits qui ne sont pas routésau réseau ou au bâtiment extérieur. Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk. Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d aération ou dans les cavités murales. La sourced alimentation doit être située à proximité de l équipement de traitement audiovisueldans un endroit ordinaire, avec un degré 2 de pollution, fixé à un équipement de rack à l intérieur d un placard, d une estrade, ou d un bureau. Always use a power supply provided by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product. Utilisez toujours une source d alimentation fournie ou recommandée par Extron. L utilisation d une source d alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d alimentation ainsi que le produit final. Do not tin the wire leads before installing into the connector. Tinned wires are not as secure in the connector and could be pulled out. They may also break after being bent several times. Ne pas étamer les conducteurs avant de les insérer dans le connecteur. Les câbles étamés ne sont pas aussi bien fixés dans le connecteur et pourraient être retirés. Ils peuvent aussi se casser après avoir été pliés plusieurs fois. Extron power supplies are certified to UL/CSA 60950-1 and are classified as LPS (Limited Power Source). Use of a non-lps or unlisted power supply will void all regulatory compliance certification. Les sources d alimentation Extron sont qualifiées UL/CSA 60950-1 et sont classées LPS (Limited Power Source). L utilisation d une source d alimentation non-listéeou non-listée LPS annulera toute certification de conformité réglementaire. The figure below shows how to wire the connector. Smooth Ridges SECTION A A Power Supply Output Cord Tie Wrap 0. (7 mm) MAX Orange Captive Screw Connector Figure 5. Power Connector Wiring NOTE: Your MDA may have shipped with a blue captive screw plug. The blue connector does not have the extended tail or the included tie-wrap.

Front Panel Features and Operation The following shows the front panel configurations of the MDA V EQ. 1 2 VIDEO DISTRIBUTION CONTROLLER 1 2 2 2 2 Figure 6. MDA V EQ Front Panel 1 Power indicator LED This LED, when lit, indicates that the MDA EQ is receiving power. 2 Gain and Equalization (EQ) potentiometers One set for each output. Use a small screwdriver to rotate these potentiometers to adjust the gain and equalization for optimization of the image over the output cable. 5

For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. 6 200-2018 Extron Electronics All rights reserved. www.extron.com All trademarks mentioned are the property of their respective owners. 68-978-50 Rev. C 09 18