Converter SINAMICS G150. Type 6SL37102G

Similar documents
Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Readme SiVArc V14 SP1 Update 6

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

Siemens Industrial s

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

ST (6ES7132-6FD00-0BB1)

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

PD PA AP How To Configure Maxum II TimeServer Access

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Siemens Automation Products

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Optional package printer driver V1.4

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

COMOS. Automation Automation interfaces. Note on file-based data exchange 1 SPI 2. Generic Excel import 3. Process visualization via OPC client 4

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

Parameter 1. Faults and alarms 2 SIMOCRANE. Truck Positioning System (TPS) Parameter Manual. applies to SIMOCRANE TPS Version 1.1

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

Basic principles 1. Configuring function diagrams based on IEC 2. Administration 3 COMOS. Automation Logical. Operating Manual 04/2015 A5E AD

COMOS. Automation COMOS Automation Interfaces SPI 1. Generic Excel import 2. Process visualization via OPC client 3.

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

COMOS. Lifecycle 3D Integration Operation. Publisher 1. COMOS PDMS Integration 2. Material management 3. COMOS 3D viewing 4.

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

Siemens Drives & PLCs

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

COMOS. Automation Logical. Basic principles 1. Configuring function diagrams based on IEC 2. Code generation based on IEC

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

COMOS. Lifecycle Material Management. General information 1. Introduction 2. Definitions 3. Creating material in COMOS 4

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Improvements in Openness 4. Readme. Readme

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

Transcription:

Tests carried out on drives This documentation pertains to LV Umrichter E11 F72 F76 F79 L45 L50 L57 L68 M54 U11 Reference Manual Converter SINAMICS G150 Type 6SL37102G Edition 02/2019 www.siemens.com/drives

14.02.2019 14:43 V8.00

Introduction 1 General scope of services 2 Converter Tests 3 SINAMICS G150 Type 6SL37102G Reference Manual This documentation pertains to LV Umrichter E11 F72 F76 F79 L45 L50 L57 L68 M54 U11 Edition 02/2019

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY Document order number: 8888888888-000088 P 02/2019 Subject to change Copyright Siemens AG 2019. All rights reserved

Table of contents 1 Introduction...7 2 General scope of services...9 2.1 Routine test...11 2.2 Visual inspection...12 2.3 Function tests...13 2.4 Insulation test...14 3 Tests...15 3.1 Visual inspection...16 3.1.1 Rating plate...16 3.1.2 Housing degree of protection...16 3.1.3 Electrical cabinet components...17 3.1.4 Cable installation...17 3.1.5 Cable markings...18 3.1.6 Setting values of circuit breakers, if used...18 3.1.7 Dimensions...18 3.1.8 Derating diagram...19 3.1.9 List of the miniature circuit breakers and circuit breakers...19 3.1.10 Marine version...19 3.2 Function test...21 3.2.1 Auxiliary voltages...21 3.2.2 Interrupted cable to the operator panel...21 3.2.3 DriveCLiQ connection, identification of the installed modules...21 3.2.4 Anti-condensation heating...22 3.2.5 Socket outlets and lighting...22 3.2.6 Sensing the actual DC link voltage...23 3.2.7 Switching thresholds of the optional temperature evaluation device...23 3.2.8 Safety shutdown (optional)...23 3.2.9 Temperature monitoring...24 3.2.10 DC link voltage failure...24 3.3 Function test with the test station motor...26 3.3.1 Operation with the test station motor...26 3.3.2 Flying restart of the rotating test station motor...26 3.3.3 Reduction of the output current...27 3.4 Cooling system test...28 3.4.1 Air flow direction...28 3.5 Insulation test...29 3.5.1 High-voltage test...29 3.5.2 Measuring the insulation resistance...30 Index...31 Reference Manual Rev.201902141443 LV Umrichter 5

Table of contents 6 Reference Manual Rev.201902141443 LV Umrichter

Introduction 1 This document describes the preconditions when testing drives. The fulfillment of these preconditions is the basis for achieving the smoothest possible testing process and maximum possible customer satisfaction. The following drive tests are described: Routine tests Tests that are offered as standard Note If the scope of testing and inspection cannot fulfill all customer requirements, please consult your Siemens sales advisor at head office. Reference Manual Rev.201902141443 LV Umrichter 7

Introduction 8 Reference Manual Rev.201902141443 LV Umrichter

General scope of services 2 A variable-speed drive can include the following components: Induction motor, synchronous motor or PEM motor with or without speed encoder SINAMICS drives Drive transformer Cooling unit for water-cooled drives Small PLCs with drive functionality. The Nuremberg Vogelweiherstrasse factory offers test equipment adapted to these types of systems. Note Contact your sales person if additional components must be taken into account for your particular project. Scope of services offered Unless otherwise stated in the quotation, the scope of services includes all activities, equipment, materials and expendables required to perform the specified tests. The deadline and testing period stated, and the quoted cost, can be met only if all the test and inspection procedures to be performed are clarified in detail in advance. Due to the high capacity utilization of the associated equipment, it might not be possible to carry out individual inspections and tests that are requested late if the planned test is already in progress. If you have received specific requirements from your customer, please send these as soon as possible with the necessary key data to the Nuremberg Vogelweiherstrasse factory. Sequence of a customer acceptance A customer acceptance test is generally executed in the sequence: 1. Installation and commissioning of the components before the customer arrives. 2. Kickoff with presentation of the test schedule and discussion of individual steps in the acceptance test workflow. 3. Execution of the tests according to the test schedule 4. Discussion of the test results 5. Preparation of test documentation for the customer. The test documentation is created before or after the customer leaves depending on the scope of testing and the time schedule. Reference Manual Rev.201902141443 LV Umrichter 9

General scope of services Components provided by customer Components provided by the customer must be available in plenty of time so that tests can be carried out on time. The Nuremberg Vogelweiherstrasse factory has no access to components that are not within the PD LD scope of supply. This also applies to components ordered from other Siemens' Groups. The technical data for these components is required at the latest eight weeks before the start of the acceptance test, e.g.: Dimensions Weights Energy Requirement Interfaces Location of the customer acceptance All customer acceptance tests in the test fields for drives are performed as part of the manufacturing process. Note Limited number of persons in the test field For safety reasons, the number of persons in the test field is limited. In addition to the regional sales partner, only two persons from the customer are permitted in the test field at the same time. Note Test without load motors or multipulse infeeds via transformers in the test field Some tests are simulated or performed in test mode with limited rated data. Note Tests with the customer's own cooling units or excitation equipment If the customer's own cooling units or excitation equipment are to be tested, a system test can be ordered with option F97. 10 Reference Manual Rev.201902141443 LV Umrichter

General scope of services 2.1 Routine test 2.1 Routine test During production, the drive is subject to an internal routine test. Reference Manual Rev.201902141443 LV Umrichter 11

General scope of services 2.2 Visual inspection 2.2 Visual inspection The visual inspection is performed to ensure that the equipment complies with the order specifications. The tests are carried out with the drive in a no-voltage condition. The visual inspection together with the customer or with the company accepting the equipment is carried out with the drive installed and labeled. Each test step is documented in the acceptance report with the specific results of the step. The visual inspection is part of the function test (F72, F73). Visual inspection Rating plate Housing degree of protection Electrical cabinet components Cable installation Cable markings Setting values of circuit breakers, if used Dimensions Without the customer present Order codes With the customer present - F03 See also Visual inspection (Page 16) The following additional tests are available for low voltage drives in the marine version. Visual inspection Derating diagram List of the miniature circuit breakers and circuit breakers Marine version Without the customer present Order codes With the customer present - F03 See also Visual inspection (Page 16) 12 Reference Manual Rev.201902141443 LV Umrichter

General scope of services 2.3 Function tests 2.3 Function tests The drive functions are tested according to IEC 61800-5-1. In addition, excerpts from additional standards apply, which are listed in the relevant chapters as well as internal Siemens directives within the scope of quality assurance. The function tests are performed and documented in the Siemens test field by internal test field personnel. For the function test, the drive is in the test mode with restricted monitoring functions. The successful test is confirmed in a 3.1 certificate or in the case that the customer has ordered the acceptance test, in a 3.2 certificate. See also Function test (Page 21) Reference Manual Rev.201902141443 LV Umrichter 13

General scope of services 2.4 Insulation test 2.4 Insulation test The insulation resistance is measured before and after the high-voltage test. The insulation test can only be ordered and carried out together with the function test (F72, F73). Insulation test High-voltage test Without the customer present Order codes With the customer present Measuring the insulation resistance F76 F77 The successful test is confirmed in a 3.1 certificate or in the case that the customer has ordered the acceptance test, in a 3.2 certificate. See also Insulation test (Page 29) 14 Reference Manual Rev.201902141443 LV Umrichter

Tests 3 The tests that have been expressly ordered for the drive with serial number 12345670001001 are listed in the following. Reference Manual Rev.201902141443 LV Umrichter 15

Tests 3.1 Visual inspection 3.1 Visual inspection The visual inspection is performed to ensure that the drive complies with the requirements of the order. The individual test steps are performed with the drive in a no-voltage condition. The test together with the customer or his representative is carried out with the drive installed and labeled. The results of all of the tests are documented in the acceptance report. 3.1.1 Rating plate The technical data and ordered options on the rating plate and the routine test certificate are checked to ensure that they match up. 1. The data on the rating plate and the routine test certificate are visually compared. The test is passed if the data match up. 3.1.2 Housing degree of protection A check is made as to whether the housing degree of protection ordered complies with what is described in the catalog. 1. The housing degree of protection is identified based on what is stamped on the rating plate. 2. Depending on the version, the following components are visually checked, e.g.: Canopies Cooling slots Fittings and rubber seals in the doors and between the cabinet units Cable entries Openings for water pipes, if available Additional components, if available 16 Reference Manual Rev.201902141443 LV Umrichter

Tests 3.1 Visual inspection The test is passed if the components required for the specified housing degree of protection are available. 3.1.3 Electrical cabinet components A visual inspection is made to see whether the electrical cabinet components are installed as defined in the layout diagram and/or circuit diagram. 1. The customer selects electrical cabinet components by random sampling. 2. The selected electrical cabinet components are visually checked to ensure that they are correctly installed and marked. The test is passed if the selected electrical cabinet components are installed as specified in the layout diagram and/or circuit diagram. 3.1.4 Cable installation Visual and mechanical checks are made to ensure that cables and conductors have been installed correctly and are connected correctly according to the circuit diagram. 1. The customer selects cables or conductors by random sampling. 2. The following is inspected: Are the cables firmly connected? Have edge protectors been attached to sharp edges? Are the cables routed according to the circuit diagram? The inspection is passed if the cable installation does not exhibit any deficiencies and matches the information in the circuit diagram. Reference Manual Rev.201902141443 LV Umrichter 17

Tests 3.1 Visual inspection 3.1.5 Cable markings A visual inspection is made to see whether cables and conductors are marked as defined in the circuit diagram. 1. The customer selects cables or conductors by random sampling. Are the cable end tags and conductor colors of cables and conductors marked as defined in the circuit diagram? The test is passed if the cable and conductor markings match what is specified in the circuit diagram. 3.1.6 Setting values of circuit breakers, if used The circuit breaker settings are visually checked against what is specified in the circuit diagram. 1. The customer selects circuit breakers by random sampling. 2. The circuit breaker settings are visually checked against what is specified in the circuit diagram. The test is passed if the circuit breaker settings match what is specified in the circuit diagram. 3.1.7 Dimensions The drive dimensions are measured. The basis for the visual inspection is the order-specific dimension drawing. 1. The external dimensions, length, width and height of the drive are measured. 18 Reference Manual Rev.201902141443 LV Umrichter

Tests 3.1 Visual inspection The test is passed if the dimensions match with what is specified in the dimension drawing. 3.1.8 Derating diagram The power must be derated for operation under higher ambient temperatures. The derating diagram required is attached to one of the drive doors. 1. The existence of the diagram is checked. The check is passed if the diagram is available 3.1.9 List of the miniature circuit breakers and circuit breakers The existence of the list with miniature circuit breakers and circuit breakers is checked. 1. Random samples of the values in the list are compared with the circuit diagram. The test is passed if the checked values match what is specified in the circuit diagram. 3.1.10 Marine version A check is made as to whether the mechanical housing design of the ordered marine version complies with what is described in the catalog. Reference Manual Rev.201902141443 LV Umrichter 19

Tests 3.1 Visual inspection 1. The housing is checked for the following components: Door bracing Frame bracing Handrail The check is passed if the components required for the marine version are available. 20 Reference Manual Rev.201902141443 LV Umrichter

Tests 3.2 Function test 3.2 Function test 3.2.1 Auxiliary voltages Tests are performed according to DIN EN 60146-1. The auxiliary voltages are visually checked using indicator lights or using a voltmeter. 1. The drive power section is switched off. 2. The auxiliary voltages are switched on. 3. The auxiliary voltages are checked. The test is passed if all of the auxiliary voltages are available. 3.2.2 Interrupted cable to the operator panel An interrupted cable to the operator panel is simulated. 1. The drive power section is switched off. 2. The auxiliary voltage is present. 3. The interface cable between the operator panel and Control Unit is withdrawn at the operator panel. The test is passed if the appropriate fault message is displayed on the operator panel. 3.2.3 DriveCLiQ connection, identification of the installed modules In automatic configuration, the installed DriveCLiQ components are detected and displayed on the test station computer. Actual and reference state of the DriveCLiQ topology are compared. Reference Manual Rev.201902141443 LV Umrichter 21

Tests 3.2 Function test 1. The auxiliary voltage is present. 2. The DriveCLiQ connector is removed at any DriveCLiQ component. A message is displayed on the test station computer. The test is passed if the appropriate message is displayed on the test station computer. 3.2.4 Anti-condensation heating A check is made as to whether the anti-condensation heating heats up after switching on. This prevents the formation of condensation in the drive when it is not operational. 1. The temperature of the anti-condensation heating is measured using an infrared thermometer. 2. The auxiliary voltage for the anti-condensation heating is switched on. The anti-condensation heating elements heat up. 3. The temperature is measured again. The test is passed if the anti-condensation heating elements heat up after they have been switched on. 3.2.5 Socket outlets and lighting Socket outlets and lighting are checked. 1. The voltage at the socket outlets is measured. 2. The lighting is checked. The test is passed if the correct voltage is available at the socket outlets and the lighting functions. 22 Reference Manual Rev.201902141443 LV Umrichter

Tests 3.2 Function test 3.2.6 Sensing the actual DC link voltage The DC link voltage actual value sensing is tested. 1. The DC link is charged up to the rated voltage. 2. The actual value sensing devices in the drive measure the voltage. The DC link voltage is displayed at the test station computer in the appropriate parameters. The test is passed if the displayed value at the test station computer matches the reference value. 3.2.7 Switching thresholds of the optional temperature evaluation device The switching thresholds of the temperature monitoring function are checked. 1. The auxiliary voltage is present. 2. The switching thresholds at the temperature sensor inputs are triggered. The following messages are displayed on the test station computer: T 1 : Alarm T 2 : Fault The test is passed if the appropriate messages are displayed on the test station computer. The tolerance range at the switching thresholds is ±5 K. 3.2.8 Safety shutdown (optional) The tests are performed according to IEC 60146-1-1 and IEC 60204-11. The safety shutdown of the power section is tested according to the category that was ordered. Reference Manual Rev.201902141443 LV Umrichter 23

Tests 3.2 Function test 1. The auxiliary voltage is present. 2. The drive is in operation. 3. The button is pressed. The test is passed if the drive is switched off in accordance with the category that was ordered and the appropriate message is displayed on the test station computer. 3.2.9 Temperature monitoring Depending on the version and application, the temperature thresholds differ for alarm and fault. Further, in operation, the drive continually recalculates the temperature thresholds. This is the reason that predefined temperature thresholds cannot be specified in the report, as only actual values are documented. 1. The auxiliary voltage is present. 2. The switching thresholds at the temperature sensor inputs are triggered. The following messages are displayed on the test station computer: T 1 : Alarm T 2 : Fault 3. The actual values for alarm and fault are documented. The test is passed if the appropriate messages are displayed on the test station computer. 3.2.10 DC link voltage failure The drive shuts down if the DC link voltage fails. DC link voltage failure is simulated by switching off the supply. 24 Reference Manual Rev.201902141443 LV Umrichter

Tests 3.2 Function test 1. The auxiliary voltage is present. The drive is in operation. 2. The DC link is charged up to 100 %. 3. The supply is switched off automatically. The DC link voltage collapses. The test is passed if the drive is shut down and the appropriate message is displayed on the test station computer. Reference Manual Rev.201902141443 LV Umrichter 25

Tests 3.3 Function test with the test station motor 3.3 Function test with the test station motor 3.3.1 Operation with the test station motor A check is made as to whether the connected test station motor is correctly controlled by the drive, and the specified speed is kept. 1. The auxiliary voltage is present. 2. The drive is switched on and controls the test station motor up to its rated speed. The rated speed is displayed on the test station computer. The test is passed if the speed setpoint and actual value match. 3.3.2 Flying restart of the rotating test station motor The test reveals whether the connected test station motor is correctly controlled after the drive fails. 1. The auxiliary voltage is present. 2. The drive is switched on and controls the test station motor. The actual speed is displayed on the test station computer. 3. The drive is switched off. The motor coasts down. 4. The drive is switched on again. The drive synchronizes itself with the motor, and controls it to the speed that was last set. The test is passed if the speed last set is returned to after the drive has recovered. 26 Reference Manual Rev.201902141443 LV Umrichter

Tests 3.3 Function test with the test station motor 3.3.3 Reduction of the output current The test reveals whether the current limiting controller actively intervenes in the drive control when an output current reduction is simulated. 1. The auxiliary voltage is present. 2. The drive is switched on and controls the test station motor. The actual speed is displayed on the test station computer. 3. The output current is reduced with the current limiting controller. The speed decreases. The appropriate alarm is displayed on the test station computer. 4. The output current is further reduced until it is no longer sufficient to operate the motor. The drive is switched off. The motor coasts down. The appropriate fault is displayed on the test station computer. The test is passed if the appropriate messages are displayed on the test station computer, and the drive is shut down. Reference Manual Rev.201902141443 LV Umrichter 27

Tests 3.4 Cooling system test 3.4 Cooling system test 3.4.1 Air flow direction It is only guaranteed that the drive is correctly cooled when the fan rotates in the correct direction of rotation. 1. The auxiliary voltage is present. 2. The drive is switched on. The fans switch on. 3. The air flow direction is checked at the ventilation grilles. The test is passed if the air flows from the doors up to the roof section. 28 Reference Manual Rev.201902141443 LV Umrichter

Tests 3.5 Insulation test 3.5 Insulation test 3.5.1 High-voltage test The test is carried out according to the following standards: IEC 61800-5-1 IEC 62103 For marine applications, additional requirements from the marine classification societies may apply. The high-voltage test verifies the voltage strength (test voltage) for overvoltage conditions specified in the standard. Test equipment A calibrated test instrument is used for the test. 1. The circuits to be tested are separately short-circuited corresponding to the individual voltage levels. Power circuit/circuits Various auxiliary circuits 2. The circuits that are presently not connected to the test instrument are connected to ground potential. 3. The test voltage is adjusted for each circuit corresponding to the insulation test report. 4. The circuits are tested with respect to one another and with respect to the PE protective conductor at the electrical cabinet. The test duration is 1 s, for marine applications, 60 s. 5. The test is repeated with 80% test voltage. The test is passed if the test instrument is not switched off (tripped) during the test as a result of flashover. Reference Manual Rev.201902141443 LV Umrichter 29

Tests 3.5 Insulation test 3.5.2 Measuring the insulation resistance Tests are performed in accordance with IEC 62103. The insulation resistance of the individual circuits is measured before and after the high-voltage test, and the following value must be obtained: Rated operating voltage Below 1000 V Above 1000 V Insulation resistance At least 1 MΩ At least 10 MΩ Test equipment A calibrated test instrument is used for the test. 1. The circuits to be tested are separately short-circuited corresponding to the individual voltage levels. Power circuit/circuits Various auxiliary circuits 2. The circuits that are presently not connected to the test instrument are connected to ground potential. 3. The test voltage is adjusted for each circuit corresponding to the insulation test report. 4. The circuits are tested with respect to one another and with respect to the PE protective conductor at the electrical cabinet. The test is passed if the insulation resistances lie within the tolerance specified by the standard. 30 Reference Manual Rev.201902141443 LV Umrichter

Index C Components provided by customer, 10 Cooling system test Air flow direction, 28 Customer acceptance inspection, 9 F F03, 12 F76, 14 F77, 14 Function tests, 13 Actual value sensing of the DC link voltage, 23 Anti-condensation heating, 22 Auxiliary voltages, 21 DC link voltage failure, 24 DriveCLiQ connection, identification of the installed modules, 21 Flying restart of the rotating test station motor, 26 Interrupted cable to the operator panel, 21 Operation with the test station motor, 26 Reduction of the output current, 27 Safety shutdown, 23 Socket outlets and lighting, 22 Switching thresholds of the optional temperature evaluation device, 23 Temperature monitoring, 24 V Visual inspection, 12, 16 Cable installation, 17 Cable markings, 18 Derating diagram, 19 Dimensions, 18 Electrical cabinet components, 17 Housing degree of protection, 16 List of the miniature circuit breakers and circuit breakers, 19 Marine version, 19 Rating plate, 16 Setting values of circuit breakers, if used, 18 I Insulation test, 14 High-voltage test, 29 Measuring the insulation resistance, 30 L L50, 22 L55, 22 L57, 23 L59, 23 L60, 23 L68, 23 Reference Manual Rev.201902141443 LV Umrichter 31

Index 32 Reference Manual Rev.201902141443 LV Umrichter

8888888888 000088 01 EN 01 Further Information www.siemens.com/drives Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY *888888888800008801EN01* 888888888800008801EN01

Process Industries and Drives Siemens AG, PD LD P MF-NMA EN, Postfach 47 43, 90025 Nürnberg Department PD LD P MF-NMA EN Tel. +49 (911) 433-6422 Fax +49 (911) 433-6921 Email motoren.doku.aud@internal.siemens.co m Our ref. 8888888888000088 Date 14.02.2019 Documentation for 6SL37102G Your order no. - 000010 AL: N ECCN: N UL: DE StWanr (CD): 85234045, StWanr (Print): 49011000 Dear Sir / Madam, Many thanks for your order, the documentation for which is enclosed. Yours very truly, *888888888800008801EN01*

Spine label for binder 50 mm (120 g/m2) SINAMICS G150 6SL37102G LV Umrichter E11 F72 F76 F79 L45 L50 L57 L68 M54 U11 Tests carried out on drives Spine label for binder 162 mm (120 g/m2) SINAMICS G150 6SL37102G LV Umrichter E11 F72 F76 F79 L45 L50 L57 L68 M54 U11 Tests carried out on drives