Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Similar documents
Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

thanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

Technical data sheet. Technical data

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

CAEL-DP Series Dew Point Transmitter for Industrial Control

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Overview of types. Technical data

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Power consumption In operation At rest For wire sizing

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Immersion Temperature Sensors

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Functional data Factory settings Variable Setting Torque Inhibiting torque

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Millenium II +: general characteristics

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Technical data sheets

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

5 Fieldbus Technology

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

RXTH DUAL ROOM SENSOR / SWITCH

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. Product features

EE160 - Humidity and Temperature Transmitter for HVAC Applications

InBin-P Pressure switches from 5 Pa Pa

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

RTU500 series Data Sheet Power Supply CP-E 24/2.5

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Airflow Pressure Sensor

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Operating instructions Evaluation system for flow sensors VS / / 2013

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

AC5160 SiPass integrated controller kit

InReg Volume flow controller Pa

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Standard reference resistor Model CER6000

Instruction Manual. T3110 T3110L T3110Ex

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Digital electropneumatic Positioner SideControl

Digital electropneumatic positioner

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

RXTP ROOM TEMPERATURE

AC5160 Controller. Fire & Security Products. SiPass integrated

THERMOSTATS & CONTROLLERS

Electrical Actuators

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

Operating instructions. Standstill monitor A / / 2011

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

C7110C1001A / C7110D1009A WALL MODULES

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Specification Sheet For electronically commutated motors

Hydrostatic filling level sensor HFB C4 / R / MD

Products no longer available

DTM Distributed Transmitter Monitor

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

PCD DIGITAL Differential pressure probe

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Extension module for lighting control

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Dräger Polytron 8200 Stationary gas detector (CatEx)

Transcription:

Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X / IP65 rated enclosure. Type Overview Type active CO₂ BACnet DC 0...5 V, DC 0...10 V active temperature DC 0...5 V, DC 0...10 V Technical Data Electrical data Power supply DC 15...24 V, ±10%, 0.3 W Power supply AC Electrical connection Cable entry 24 V, ±10%, 6 VA Removable spring loaded terminal block max. 2.5 mm² Cable gland with strain relief 2 x Ø6 mm Functional data Sensor Technology CO₂: NDIR (non dispersive infrared) dual channel rh: with stainless steel wire mesh filter Communicative control active note Media BACnet MS/TP Measuring data Measuring values CO₂ Temperature Relative humidity Measuring range CO₂ Measuring range humidity Measuring range temperature Measuring range absolute humidity Measuring range enthalpy Output DC 0...5/10 V selectable with switch Air 0...2000 ppm 0...100% rh Attention: max. measuring temperature is restricted by max. medium temperature (see Safety data) 0...80 g/m³ 0...85 kj/kg Measuring range dew point -20...80 C Accuracy CO₂ ±(50 ppm + 3% of measuring value) Accuracy humidity ±2% between 10...90% r.h. @ 21 C Accuracy temperature active ±0.5 C @ 21 C [±0.9 F @ 70 F] www.belimo.com en-gb 2019-01-10 Subject to change 1 / 5

Materials Cable gland PA6, black Housing Probe material UV resistant Cover: Lexan, orange Bottom: Lexan, orange Seal: 0467 NBR70, black PA6, black Safety data Ambient humidity Max. 95% r.h., non-condensing Ambient temperature Medium temperature Operating condition air flow Protection class IEC/EN Protection class UL min. 0.3 m/s max. 10 m/s III Safety Extra-Low Voltage (SELV) UL Class 2 Supply Certification IEC/EN IEC/EN 60730-1 Certification UL Degree of protection IEC/EN Degree of protection NEMA/UL culus acc. to UL60730-1A/-2-9/-2-13, CAN/ CSA E60730-1:02/-2-9 IP65 Quality Standard ISO 9001 NEMA 4X, UL Enclosure Type 4X Safety notes The installation and assembly of electrical equipment should only be performed by authorized personnel. This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application. Unauthorised modifications are prohibited. The product must not be used in relation with any equipment that in case of a failure may threaten human, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual www.belimo.com en-gb 2019-01-10 Subject to change 2 / 5

Remarks General remarks concerning sensors Build-up of Self-Heating by Electrical Dissipative Power Application Notice for Humidity Sensors Information Self-Calibration Feature CO₂ Sensing devices with a transducer should always be operated in the middle of the measuring range to avoid deviations at the measuring end points. The ambient temperature of the transducer electronics should be kept constant. The transducers must be operated at a constant supply voltage (±0.2 V). When switching the supply voltage on/off, onsite power surges must be avoided. Temperature sensors with electronic components always have a dissipative power which affects the temperature measurement of the ambient air. The dissipation in active temperature sensors shows a linear increase with rising operating voltage. This dissipative power should be taken into account when measuring temperature. In case of a fixed operating voltage (±0.2 V) this is normally done by adding or reducing a constant offset value. As Belimo transducers work with a variable operating voltage, only one operating voltage can be taken into consideration, for reasons of production engineering. Transducers 0...10 V / 4...20 ma have a standard setting at an operating voltage of DC 24 V. That means, that at this voltage, the expected measuring error of the output signal will be the least. For other operating voltages, the offset error will be increased by a changing power loss of the sensor electronics. If a re-calibration should become necessary later directly on the sensor, this can be done by means of a trimming potentiometer on the sensor board. Refrain from touching the sensitive humidity sensor/element. Touching the sensitive surface will void warranty. For standard environmental conditions the manufacturing accuracy specified in the datasheet will be covered by the calibration warranty for two years. When exposed to harsh environmental conditions such as; high ambient temperature and/or high levels of humidity or presence of aggressive gases (i.e. chlorine, ozone, ammonia) the sensor element may be affected and readings may be outside specified accuracy. Replacement of deteriorated humidity sensor due to harsh environmental conditions are not subject of the general warranty. All CO₂ sensors are subject to drift caused by the aging process of the components, resulting in regular re-calibration or replacement units. However the dual channel technology integrates automatic self-calibration technology vs common used ABC-Logic sensors. Dual channel self-calibration technology is ideally suited for applications operating 24/7 hours such as hosiptals or other commerical applications. Manual calibration is not required. Scope of delivery Scope of delivery Description Type Mounting flange for duct sensor 19.5 mm A-22D-A35 Accessories Optional accessories Description Type Replacement filter Stainless steel, wire mesh A-22D-A06 Connection adapter M20 for cable 1 x 6 mm (Multi-pack 10 pieces) A-22G-A01.1 Connection adapter M20 for cable 2 x 6 mm (Multi-pack 10 pieces) A-22G-A02.1 www.belimo.com en-gb 2019-01-10 Subject to change 3 / 5

Wiring diagram 1 and 5: Status LED 2 red: Error 3 yellow: Tx 4 yellow: Rx Detailed documentation Notes Wiring RS485 Wiring RS485 (Modbus RTU & BACnet MS/ TP) The separate document, BACnet PICS, informs about the PICS, MAC addressing and bus Termination (DIP1 & DIP2). Connection via safety isolating transformer. Parallel connection of other devices possible. Observe the performance data. The wiring of the line for BACnet MS/TP / Modbus RTU is to be carried out in accordance with applicable RS485 regulations. Modbus / BACnet: Supply and communication are not galvanically isolated. Connect earth signal of the devices with one another. www.belimo.com en-gb 2019-01-10 Subject to change 4 / 5

Dimensions Dimensions Type Weight 0.27 kg www.belimo.com en-gb 2019-01-10 Subject to change 5 / 5