Motor Controls Made Easy 508A

Similar documents
Motor Controls Made Easy 508A

Teslights Hybrid Lighting Controls B-PLC Solution

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

User Guide. Control Box. RoscoLED TM.

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Sonic Ruptor 400. User Manual

MICRO GROW GREENHOUSE SYSTEMS, INC

High contrast 3.25 backlit mono LCD screen Screen resolu on 128x64 pixels Screen LCD brightness of 250 lumens for easy viewing in direct sunlight

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

PowerFlex 400 AC Drive Guide Specification

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

IPS INTELLIGENT PUMP STARTER

OPERATIONS MANUAL PCM-I/O48

ENGINEERED SOLUTIONS. Solutions for Any Application. us.mitsubishielectric.com/fa/en/

Proliphix EPA-60 Installation Guide

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

To Purchase This Item, Visit BMI Gaming (800)

SC-9

I/O Expansion Box Installation & Operator s Instruction Manual

1510 MOTOR CONTROLLERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

STANDARD SUBMITTAL PACKAGE

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

212iL Rev. 1.1

Number of input channels

Resolver to Digital Expansion Board

SERVICE MANUAL MODEL SSP-561-X-ADA

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Basketball Shot Clock Set LX2180 Manual

Chroma-Q Color Web PSU 10-DMX. User Manual

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

WaterGlowTM. LL1020 Submersible Landscape Light Owners Manual. Thermal Overload Protection, Gasket, & Potting Eliminate Leaks.

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

zpen-1080p Features zpen-1080p Layout

Install Motor Controller User Manual

AirTest Model CN9000 Series Sensor Controller

SECTION VARIABLE FREQUENCY DRIVES

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Push-Pull and E-Stop Switches. Datasheet

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

SERVICE MANUAL MODEL SSW-521-D2-ADA

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

MTS-2000 USER S MANUAL

S82S (3/7.5-W Models)

PSA200 User s Manual

PCM-7140 Pulsed Current Source Operation Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

SOLARIMMERSION IV Advanced Installation Manual v1.9

EMD-100 ELECTRIC DISPERSER

CA-A480-A Elevator Controller. Reference & Installation Manual

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Remote Refrigeration Control

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

User's Guide. MiniTec TM Series Model MN25 MultiMeter

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Chroma-Q Magic Box EthernetSwitch 7

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Digital Lighting Systems, Inc.

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

SERVICE MANUAL MODEL SSW-520-F

DC425 NEMA 4X Analog Output Transducers

fire cam 1080 user manual

SmartVFD HVAC and BYPASS

PIM-Mini Pulsed Current Source Operation Manual

EMS Electrical Management System

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Remote Power Management & Monitoring System MODEL: 1RU8126MS USER MANUAL E Lake Mary Blvd. Sanford, FL (407) (800)

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

ELECTRO-MECH SCOREBOARD CO.

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

VLT 2800 DRIVE SPECIFICATIONS

Operating instructions. Switching amplifier DN0210 DN / / 2015

CONTROL SYSTEMS SOLUTIONS FOR PRECISION MOTION TECHNOLOGY. Your First Choice. for Control Systems Solutions

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX

Transcription:

Motor Controls Made Easy 508A Siemens Drive Package Partner Program

MISSION STATEMENT To provide complete automa on solu ons for the United States and interna onal market with products and service that meet or exceed customer expecta ons for quality, performance, and reliability at the lowest possible cost and delivered within the customer s schedule, through our authorized distribu on network. COMPANY HISTORY North American Electric opened its doors in 1993 and began distribu ng high quality electric motors, electric motor control panels and sha mount gearing throughout our na onal distribu on and OEM network. We are a UL 508A panel shop and package across the line, part wind, so starter and variable frequency drive panels. We offer pre engineered and custom panels for general purpose as well as special purpose applica on for the oil & gas and agricultural markets. Motor Controls

PART WIND STARTERS 10 HP 200 HP IEC Rated Contactors Circuit Breaker or Fused NEMA 3R Enclosure SOFT STARTERS 15 HP 300 HP Siemens 3RW40 Series Devices Normal Duty or Heavy Duty Circuit Breaker w/ Through Door NEMA 3R, 4/12 or 4X Enclosure SOFT STARTERS CRUSHER/SEVERE 20 HP 800 HP Siemens 3RW44 Series Devices Ultra Heavy Duty Circuit Breaker w/ Through Door NEMA 3R or 4/12 Enclosure VFD ECONOMY 1 HP 200 HP Variable Torque ½ HP 150 HP Constant Torque Non Combo, Circuit Breaker or Fused NEMA 3R, 4, 4X or 12 Enclosure VFD STANDARD 1 HP 700 HP Variable Torque ½ HP 600 HP Constant Torque Circuit Breaker or Fused NEMA 3R, 4, 4X or 12 Enclosure VFD STAINLESS 1 HP 700 HP Variable Torque ½ HP 600 HP Constant Torque Circuit Breaker or Fused NEMA 4X Enclosure VFD IRRIGATION 1 HP 700 HP 24/7 Programmable & 0 10 Backspin Timer Variable Torque Circuit Breaker or Fused NEMA 3R Enclosure VFD SUBMERSIBLE ½ HP 200 HP 24/7 Programmable & 0 10 Backspin Timer Variable Torque Circuit Breaker or Fused NEMA 3R Enclosure VFD POSITIVE DISPLACEMENT PUMP 3 HP 600 HP Constant Torque Circuit Breaker w/ Flanged NEMA 3R Enclosure VFD BEAM PUMP 1 HP 300 HP ReGen Avoidance Design Constant Torque Circuit Breaker w/ Flanged NEMA 3R Enclosure CUSTOM PANELS 3

VFD Revolu onary Warranty No Hassle Chassis Exchange Program NAE NO HASSLE CHASSIS EXCHANGE PROGRAM Providing reliable control panel service for up to six (6) years! NAE NO HASSLE CHASSIS EXCHANGE PROGRAM North American Electric s No Hassle Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running. Our No Hassle Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime. NO HASSLE CHASSIS EXCHANGE PROGRAM WARRANTY NAE s No Hassle Chassis Exchange Program Warranty period is three (3) years from the date of delivery, and must be activated by an NAE Authorized or Certified Installer. This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years! Program warranty benefits include: Lightning, surge and severe overvoltage protection Single phasing, phase reversal and voltage unbalance protection Bumper to Bumper panel coverage Same day shipment of exchange chassis (Next Day Air, Second Day Air and Hot Shot Service is available for an additional charge) Visit our website at www.naemotors.com/chassis exchangeprogram for complete terms and conditions. BUMPER TO BUMPER COVERAGE Your entire panel is further protected with our three (3) year Bumper to Bumper coverage, and includes Lightning & Surge Protection covering momentary anomaly including line side events such as lightning, surge and severe overvoltage, and load side events such as single phasing, phase reversal and voltage unbalance. 4

So Starter General Purpose Panel Package Normal Duty or Heavy Duty Non Combo or Combina on Circuit Breaker Disconnect Siemens 3RW40 Series Device NEMA 3R, 4/12 or 4X Enclosure Standard Features for Base Models Include: ❶ 15 HP 300 HP Ra ng in Stock ❷ NEMA 3R, 4/12 or 4X Enclosure ❸ Non Combina on or Combina on Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device Integrated ByPass Contact System Adjustable Current Limi ng Intrinsic Device Protec on LED Status / Fault Monitoring Remote Reset So Stop Capable Motor Overload Protec on (Class 10, 15 or 20) ❺ Isola on Contactor ❻ Illuminated Start Pushbu on ❼ Hand / Off / Auto (HOA) Selector Switch ❽ Illuminated Reset Pushbu on ❾ Surge Suppressor ❿ Heavy Duty Moun ng Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Cer fied ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w/ Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓯ Other Op ons Available SIEMENS 3RW40 SOFT STARTER NORMAL OR HEAVY DUTY CLASS 10, 15 OR 20 OVERLOAD NON COMBO OR CIRCUIT BREAKER 240V: 15 HP 150 HP 480V: 25 HP 300 HP NEMA 3R, 4/12 or 4X VFD General Purpose Panel Package Economical Solu ons for Basic Drive Applica ons Non Combo, Circuit Breaker or Fused Disconnect NEMA 3R, 4, 4X or 12 Enclosure Standard Features for Base Model Includes: ❶ 1 HP 200 HP Ra ngs in Stock ❷ NEMA 3R, 4, 4X or 12 Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (NEMA 3R) ❹ Combina on Circuit Breaker Disconnect: Through Door or Flanged ❺ Easy to Use Drive for Basic Applica ons Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering ❻ Surge Suppressor ❼ Start Pushbu on ❽ Hand / Off / Auto (HOA) Selector Switch ❾ Poten ometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Cer fied ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w/ Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓮ Other Op ons Available SIEMENS V20 and G120 ECONOMY PACKAGE VARIABLE OR CONSTANT TORQUE NON COMBO, CIRCUIT BREAKER OR FUSED 240V: 1/2 HP 60 HP 480V: 1 HP 200 HP NEMA 3R, 4, 4X OR 12 5

VFD General Purpose Panel Package Pre Engineered / Pre Packaged Drive Solu ons Combina on Circuit Breaker or Fused Disconnect NEMA 3R, 4, 4X or 12 Enclosure Standard Features for Base Model Includes: ❶ 1/2 HP 700 HP Ra ngs in Stock ❷ NEMA 3R, 4, 4X or 12 Enclosure ❸ Door Mounted Keypad with Lockable Metal / Windowed or Solid Protec ve Cover ❹ Advanced Tunnel Design for Maximum Cooling (NEMA 3R) ❺ Combina on Circuit Breaker or Fused Disconnect: Through Door or Flanged ❻ Pre Packaged Drive Solu ons for General Applica on Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering ❼ Surge Suppressor ❽ Start Pushbu on ❾ Hand / Off / Auto (HOA) Selector Switch ❿ Poten ometer (Speed Pot) ⓫ Run Light ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Cer fied ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w/ Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓰ Other Op ons Available SIEMENS V20/G120/G130 STANDARD PACKAGE VARIABLE OR CONSTANT TORQUE 240V: 1/2 HP 60 HP 480V: 1/2 HP 700 HP CIRCUIT BREAKER OR FUSED NEMA 3R, 4, 4X or 12 VFD Special Purpose Panel Package Agricultural / Irriga on Pump Design Pre Engineered / Pre Packaged Drive Solu ons Combina on Circuit Breaker or Fused Disconnect NEMA 3R Enclosure Standard Features for Base Model Includes: ❶ 1 HP 700 HP Ra ngs in Stock ❷ Fully Gasketed / NEMA 3R / Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal / Windowed or Solid Protec ve Cover ❹ Advanced Tunnel Design for Maximum Cooling (40 C) (60 HP 700 HP) ❺ Combina on Circuit Breaker or Fused Disconnect: Through Door or Flanged ❻ Pre Packaged Drive Solu ons for Special Applica on PID Loop Control Capable with Analog Input Line Side Harmonic Filtering ❼ Lightning & Surge Protec on Covering Momentary Anomaly Events Line Side Ligh ng, Surge and Severe Overvoltage Load Side Single Phasing, Phase Reversal and Voltage Unbalance ❽ 0 10 Minute Restart (Backspin) Timer ❾ 24/7 Programmable Timer ❿ Start Pushbu on Red = Fault ⓫ Hand / Off / Auto (HOA) Selector Switch Blue = Backspin Mode ⓬ Poten ometer (Speed Pot) ⓭ High Visibility Status Light Green = Running ⓮ Heavy Duty Li ing Ears (20 HP 700 HP) ⓯ Leg Stands Included (60 HP 700 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Cer fied ⓳ Three (3) Year Warranty with Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓴ Other Op ons Available INCLUDES NAE s NO HASSLE CHASSIS EXCHANGE PROGRAM SIEMENS V20/G120/G130 IRRIGATION PACKAGE VARIABLE TORQUE 240V: 3/4 HP 60 HP 480V: 1 HP 700 HP CIRCUIT BREAKER OR FUSED NEMA 3R 6

VFD Stainless Panel Package Pre Engineered / Pre Packaged Drive Solu ons Combina on Circuit Breaker or Fused Disconnect NEMA 4X Enclosure Standard Features for Base Model Includes: ❶ 1 HP 200 HP Ra ngs in Stock ❷ NEMA 4X Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combina on Circuit Breaker or Fused Disconnect ❺ Pre Packaged Drive Solu ons for Wash down Applica on Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering ❻ Surge Suppressor ❼ Start Pushbu on ❽ Hand / Off / Auto (HOA) Selector Switch ❾ Poten ometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Cer fied ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w/ Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓮ Other Op ons Available SIEMENS V20 and G120 WASHDOWN DUTY PACKAGE VARIABLE OR CONSTANT TORQUE 240V: 1/2 HP 60 HP 480V: 1 HP 200 HP CIRCUIT BREAKER OR FUSED NEMA 4X VFD Special Purpose Panel Package Submersible Pump Design Pre Engineered / Pre Packaged Drive Solu ons Combina on Circuit Breaker Disconnect NEMA 3R Enclosure Standard Features for Base Model Includes: ❶ 1/2 HP 200 HP Ra ngs in Stock ❷ Fully Gasketed / NEMA 3R / Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal / Windowed or Solid Protec ve Cover ❹ Advanced Tunnel Design for Maximum Cooling (40 C) (60 HP 200 HP) ❺ Combina on Fused Disconnect: Through Door or Flanged ❻ Pre Packaged Drive Solu ons for Special Applica on PID Loop Control Capable with Analog Input Line Side Harmonic Filtering ❼ Lightning & Surge Protec on Covering Momentary Anomaly Events Line Side Ligh ng, Surge and Severe Overvoltage Load Side Single Phasing, Phase Reversal and Voltage Unbalance ❽ 0 10 Minute Restart (Backspin) Timer ❾ 24/7 Programmable Timer ❿ Start Pushbu on Red = Fault ⓫ Hand / Off / Auto (HOA) Selector Switch ⓬ Poten ometer (Speed Pot) Blue = Backspin Mode ⓭ High Visibility Status Light Green = Running ⓮ Heavy Duty Li ing Ears (20 HP 200 HP) ⓯ Leg Stands Included (60 HP 200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Cer fied ⓳ Three (3) Year Warranty with Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓴ Other Op ons Available INCLUDES NAE s NO HASSLE CHASSIS EXCHANGE PROGRAM SIEMENS V20 and G120 SUBMERSIBLE PACKAGE VARIABLE TORQUE 240V: 1/2 HP 30 HP 480V : 1/2 HP 200 HP CIRCUIT BREAKER NEMA 3R 7

VFD Special Purpose Panel Package Posi ve Displacement Pump Pre Engineered / Pre Packaged Drive Solu ons Combina on Circuit Breaker Disconnect NEMA 3R Enclosure Standard Features for Base Model Includes: ❶ 3 HP 600 HP Ra ngs in Stock ❷ Fully Gasketed / NEMA 3R / Heavy Duty Enclosure ❸ Door Mounted Keypad or Touchscreen with Lockable Metal / Solid Protec ve Cover ❹ Advanced Tunnel Design for Maximum Cooling (50 C) (50 HP 0 HP) ❺ Combina on Circuit Breaker Disconnect: Through Door or Flanged ❻ Pre Packaged Drive Solu ons for Special Applica on Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering ❼ Lightning & Surge Protec on Covering Momentary Anomaly Events Line Side Ligh ng, Surge and Severe Overvoltage Load Side Single Phasing, Phase Reversal and Voltage Unbalance ❽ Start Pushbu on ❾ Hand / Off / Auto (HOA) Selector Switch ❿ Poten ometer (Speed Pot) ⓫ High Visibility Status Light (Red/Yellow/Green) ⓬ Op onal: Murphy Switch Interface or HMI Packages ⓭ Heavy Duty Li ing Ears ⓮ Leg Stands Included (40 HP 600 HP) ⓯ Padlockable Door and Disconnect ⓰ Service Entry Rated ⓱ UL 508A Cer fied ⓲ Three (3) Year Warranty with Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓳ Other Op ons Available SIEMENS V20/G120/G130 POSITIVE DISPLACEMENT PUMP PANEL PACKAGE CONSTANT TORQUE OPTIONAL: MURPHY SWITCH INTERFACE OR HMI PACKAGES 480V: 3 HP 600 HP CIRCUIT BREAKER STD, ADV OR DLX PKG NEMA 3R INCLUDES NAE s NO HASSLE CHASSIS EXCHANGE PROGRAM Standard (STD) Package Designed for applica ons where addi onal fault monitoring and enhanced programming capability is not required. Advanced (ADV) Package Murphy Switch Interface Designed for applica ons where addi onal fault monitoring may be required. Deluxe (DLX) Package HMI Designed for applica ons where addi onal fault monitoring and enhanced programming capability is required. 8

VFD Special Purpose Panel Package Oil Field / Pump Jack / Beam Pump Economy or Standard Pre Engineered / Pre Packaged Drive Solu ons Combina on Circuit Breaker Disconnect NEMA 3R Enclosure Standard Features for Base Model Includes: ❶ 1 HP 300 HP Ra ngs in Stock ❷ Fully Gasketed / NEMA 3R / Heavy Duty Enclosure ❸ Standard Package Includes: Door Mounted Keypad with Lockable Metal / Solid Protec ve Cover ❹ Advanced Tunnel Design for Maximum Cooling (50 C) (50 HP 150 HP) ❺ Combina on Circuit Breaker Disconnect: Through Door Disconnect (1 HP 40 HP) Flanged Disconnect (50 HP 300 HP) ❻ Pre Packaged Drive Solu ons for Special Applica on: Regenera ve (ReGen) Avoidance Programmed in Firmware Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering ❼ Lightning & Surge Protec on Covering Momentary Anomaly Events Line Side Lightning, Surge and Severe Overvoltage Load Side Single Phasing, Phase Reversal and Voltage Unbalance ❽ 24/7 Programmable Timer ❾ Start Pushbu on ❿ Hand / Off / Auto (HOA) Selector Switch ⓫ Poten ometer (Speed Pot) APPLICATION: Beam Pump Package ⓬ Heavy Duty Li ing Ears (10 HP 300 HP) designed specifically for use on beam pumps where ⓭ Leg Stands Included (50 HP 150 HP) regenera ve avoidance is required. ⓮ Padlockable Door and Disconnect ⓯ Service Entry Rated ⓰ UL 508A Cer fied ⓱ Three (3) Year Warranty with Lightning & Surge Protec on INCLUDING NAE s No Hassle Chassis Exchange Program ⓲ Other Op ons Available INCLUDES NAE s NO HASSLE CHASSIS EXCHANGE PROGRAM SIEMENS G120 BEAM PUMP PACKAGE w/ REGEN AVOIDANCE CONSTANT TORQUE 480V: 1 HP to 300 HP CIRCUIT BREAKER ECONOMY OR STANDARD DESIGN NEMA 3R Op on Shown: Mobile HMI Panel Economy (ECN) Design Standard (STD) Design 9

Panel Packages Control Op ons CONTROL OPTIONS Examples: Green (Run) Blue (Bypass) Red (Fault) Pilot Lights Mul Motor Panels Main Line Only (MLO) Box (Side Install) Three Contactor Bypass Meters Optional Push Buttons, Selector Switches, Filters and More Available. Just Ask. 10

Panel Packages Build Op ons CUSTOM PANELS Motor Controls Panel Customization Made Easy NAE Motor Controls offers customers the ability to custom order their own control panel to meet their specific needs and have it shipped quickly. We offer control panels from across the line panels to variable frequency drives and everything in between. NAE Motor Controls can package the most common controls to the most complex control systems. All NAE packaged panels are backed by our two (2) year warranty and eligible for up to (6) years of protec on with our No Hassle Chassis Exchange Program. CUSTOM PANELS 11

VFD Special Feature NEMA 3R Enclosure 53 AND UP ADVANCED TUNNEL DESIGN SPECIAL FEATURE 40 C VT; 50 C CT NEMA 3R ONLY Advanced Tunnel Design for Maximum Cooling 53" Height and Up Enclosures 40 C VT; 50 C CT Significantly Reduces Contaminants 12

2000 SERIES SIEMENS VARIABLE FREQUENCY DRIVE (VFD) CONTROL PANEL OPTIONS M50¹ MODEL LIST DESCRIPTION PRICE NUMBER (w/ Installation) PUSH BUTTONS 004 Start Pushbutton $138 005 Stop Pushbutton $138 043 Start / Stop Pushbutton $189 007 Jog Pushbutton $138 009 Raised Pushbutton Specify Color and Function $138 010 Flush Pushbutton Specify Color and Function $152 011 Mushroom Type Pushbutton Specify Color and Function $212 012 Illuminated Pushbutton Specify Color and Function $278 008 Soft Start or VFD Chassis Reset Pushbutton $138 PILOT LIGHTS 006 Run Light $159 013 Stop Light $159 023 Power On Light $159 014 Fault Light $159 015 Ready Light $159 016 Bypass Light $159 017 Red Light Specify Function $159 018 Green Light Specify Function $159 019 Amber Light Specify Function $159 020 White Light Specify Function $159 021 Blue Light Specify Function $159 022 Push to Test Contact Assembly $159 065 High Visibility Status Light (PLC may required for complete functionality) $249 SELECTOR SWITCHES 024 Hand Off Auto / HOA Selector Switch $200 025 Local Off Remote Selector Switch $200 026 Key Operated Hand Off Auto Selector Switch $330 002 Two Position Selector Switch Specify Function $162 003 Three Position Selector Switch Specify Function $197 027 Other Selector Switch Specify Function and Type POTENTIOMETERS 032 1 Turn Potentiometer (NEMA 3R, NEMA 4 and NEMA 12) $146 033 10 Turn Potentiometer (NEMA 3R, NEMA 4 and NEMA 12) $146 METERS 028 Ammeter $319 029 Voltmeter $319 030 Elapsed Time Meter $236 031 Other Power Metering Specify Function TIMERS 037 24/7 Programmable Timer $120 116 0 10 Minute Restart (Back Spin) Timer $150 OTHER DOOR MOUNTED OPTIONS 044 Door Mounted Keypad $255 045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $530 055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $530 066 Plastic Protective Cover (NEMA 4X/IP66) for Door Mounted Keypad $540 ADVANCED FAULT / STATUS MONITORING OPTIONS 110 Stack / Tower Light 360 Visibility (Red / Yellow / Green) w/ 6' Cable $720 040 Murphy Switch Interface W/ Fault Recall Function $1,593 067 Siemens SIMATIC HMI TP 700, Touch Operation, 7" Widescreen TFT Display 3 (PLC Required) $2,520 052 Two Way Cellular Communication & Functionality $749 200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel 3 (PLC Required) $4,990 201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $378 202 6AV21815AG800AX0 Wall holder, Type 13 for KTP700 mobile without attachment parts, incl. cable tray $268 203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile, Length 2 m (6.56 ft) $326 204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile, length 5 m (16.40 ft) $406 205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile, Length 8 m (26.24 ft) $496 206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile, length 10 m (32.80 ft) $544 207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile, Length 15 m (49.21 ft) $653 208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile, Length 20 m (65.61 ft) $762 209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile, Length 25 m (82.02 ft) $822 061 Cloud Based Remote Monitoring ¹ Mul plier Symbol 2 Warranty Details on pp. 15 18 Please email sales@naemotors.com, or contact us at 800 884 0404 for assistance 13

2000 SERIES SIEMENS VARIABLE FREQUENCY DRIVE (VFD) CONTROL PANEL OPTIONS M50¹ MODEL LIST DESCRIPTION PRICE NUMBER SIEMENS DRIVE CHASSIS OPTIONS ¹ Mul plier Symbol 2 Warranty Details on pp. 15 18 Please email sales@naemotors.com, or contact us at 800 884 0404 for assistance (w/ Installation) 073 V20 Smart Access $182 074 V20 BOP Basic Operator Panel for V20 Drive $52 075 BOP Interface Connection between the V20 BOP and the V20 Drive $31 077 IOP Intelligent Operator Panel for G120 Drive $360 080 AOP30 Advanced Operator Panel for G130 Drive 3 $1,817 PROGRAMMABLE RELAY OPTIONS 150 PLC 6ES72121HE400XB0 SIMATIC S7 1200, CPU 1212C (Includes Power Supply Module) $305 151 PROG RELAY LRE08RA240 Expansion Module, Programmable Relay $165 PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS 152 PLC 6ES72121HE400XB0 SIMATIC S7 1200, CPU 1212C (Includes Power Supply Module) $521 153 PLC 6ES72141HE400XB0 SIMATIC S7 1200, CPU 1214C (Includes Power Supply Module) $713 154 PLC 6ES72231PH320XB0 S7 1200 Expansion Module, Digital Input $274 155 PLC 6ES72314HA300XB0 SIMATIC S7 1200, CPU Analog Input $131 SENSOR OPTIONS 100 4 Wire Micro DC Cord Set, Straight Connector, Coupling Nut, Black PUR Jacket, 5 Meter $40 101 4 Wire Micro DC Cord Set, Straight Connector, Coupling Nut, Gray PUR Jacket, 10 Meter $40 102 Pressure Transducer, 0 100 PSI, 4 Pin Micro DC Connector $500 103 Pressure Transducer, 0 200 PSI, 4 Pin Micro DC Connector $500 104 Pressure Transducer, 0 250 PSI, 4 Pin Micro DC Connector $500 105 Pressure Transducer, 0 500 PSI, 4 Pin Micro DC Connector $500 106 Level Transducer $1,500 FUSES We Stock Fuses for Convenience. Please Call for Pricing. SPACE HEATERS 034 Space Heater with Thermostat $426 MISCELLANEOUS 054 Transformer $149 PROTECTION MECHANISMS 041 Surge Suppressor $307 115 SymCom MotorSaver Model 460 $204 064 dv / dt Filters 062 IEEE 519 Passive Harmonic Filter 063 "Lightning and Surge" Protection 2 All panels will include line side lightning, surge and severe overvoltage protection, which comprises $949 one (1) additional year of warranty coverage on the entire panel. In addition, all soft starter & VFD panels will include load side single phasing, phase reversal and voltage unbalance protection, and are eligible for NAE's "No Hassle" Chassis Exchange Program MAIN LINE ONLY BOXES 070 Main Line Only Box: 20" Tall, 16" Wide, 12" Depth $1,799 071 Main Line Only Box: 20" Tall, 20" Wide, 12" Depth $2,399 072 Main Line Only Box: 20" Tall, 24" Wide, 12" Depth $5,599 FLOOR STANDS SPFSK 1212 W 2 Legs; 12" Tall, 12" Depth $223 SPFSK 1214 W 2 Legs; 12" Tall, 14" Depth $250 SPFSK 1216 W 2 Legs; 12" Tall, 16" Depth $250 SPFSK 1220 W 2 Legs; 12" Tall, 20" Depth $276 SPFSK 1224 W 2 Legs; 12" Tall, 24" Depth $300 SPFSK 624 W 2 Legs; 6" Tall, 24" Depth $300 SPFSK 1212 N4X 2 Legs; 12" Tall, 12" Depth, NEMA 4X 304 Stainless Steel $846 SPFSK 1218 N4X 2 Legs; 12" Tall, 18" Depth, NEMA 4X 304 Stainless Steel $1,014 SPFSK 1224 N4X 2 Legs; 12" Tall, 24" Depth, NEMA 4X 304 Stainless Steel $1,069 14

ELECTRIC MOTOR CONTROLS WARRANTY POLICY & PROCEDURES North American Electric, Inc. (aka NAE) warrants all products will conform to final specifica ons and/or drawings and will be free from defects in materials and workmanship. Special build panels will require the final specifica ons and drawings to be approved in wri ng by the Buyer before being released for produc on. This warranty shall remain in effect for a period specified for each product line (24, 36 or 60 months) from the date of the invoice. See warranty period for each product line below: CHASSIS So Start Chassis: Siemens So Starter Chassis..24 months from date of invoice 3RW30 Series, 3RW40 Series, 3RW44 Series Variable Frequency Drive Chassis: Siemens VFD Chassis...24 months from date of invoice V20 Series, V120 Series, V130 Series ENCLOSED PANEL PACKAGES Reduced Voltage So Starter Panels: General Purpose So Starters..24 months from date of invoice Normal Duty, Heavy Duty and Ultra Heavy Duty Variable Frequency Drive Panels: General Purpose Economy Panel Packages...24 months from date of invoice Variable Torque and Constant Torque General Purpose Standard Panel Packages. 24 months from date of invoice Variable Torque and Constant Torque Special Purpose Irriga on Pump Panel Packages...36 months from date of invoice with Lightning & Surge Protec on INCLUDING No Hassle Chassis Exchange Program Special Purpose Submersible Pump Panel Packages. 36 months from date of invoice with Lightning & Surge Protec on INCLUDING No Hassle Chassis Exchange Program Special Purpose Posi ve Displacement Pump Panel Packages....36 months from date of invoice Standard, Advanced and Deluxe Panel Packages with Lightning & Surge Protec on INCLUDING No Hassle Chassis Exchange Program Special Purpose Beam Pump Panel Package..36 months from date of invoice with Lightning & Surge Protec on INCLUDING No Hassle Chassis Exchange Program Special Purpose Custom / Build To Order Panel Package. 24 months from date of invoice (Customer must review, approve and sign drawings prior to panel being released for produc on) Parts replaced or repaired in the warranty period shall carry the full warranty; the balance of the equipment will carry the unexpired por on of the original warranty. The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defec ve or do not conform to such specifica ons and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered. The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Seller s facility for repair or replacement. If the Seller has determined warranty part or parts are to be repaired at the job site, a purchase order must be issued for traveling and living expenses. All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary informa on required by the Seller. Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyer s expense. The above condi ons must be met if warranty is to be valid. Seller will not be liable for any damage done by unauthorized repair work, unauthorized replacement parts, from any misapplica on of the product, or for damage due to accident, abuse, or act of God. 15

Seller makes no warran es, express or implied including any warranty as to merchantability or fitness for a par cular use. Seller is not liable for and Purchaser waives any right of ac on it has or may have against seller for any consequen al or special damages arising out of any breach of warranty, and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use, opera on or maintenance of the product. Seller will not be liable for any labor subcontracted or performed by Purchaser for prepara on of warranted item for return to Seller s facility or for prepara on work for field repair or replacement. Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller. North American Electric s liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defec ve material and workmanship, and in no event shall North American Electric, Inc. be liable for consequen al or indirect damages, including freight. LIGHTNING & SURGE PROTECTION NAE s Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include Lightning & Surge Protec on as a standard feature, but it may also be purchased separately (LIST Price: $949.00). All panel packages which receive this protec on will include line side lightning, surge and severe overvoltage protec on, which will comprise of one (1) addi onal year of warranty coverage on the en re panel. In addi on, all So Starter & VFD panel packages which receive this protec on will include load side single phasing, phase reversal and voltage unbalance protec on, and are eligible for NAE s No Hassle Chassis Exchange Program. NOTE: This protec on is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel. The panel must be properly grounded. ELECTRIC MOTOR CONTROLS WARRANTY CLAIM PROCEDURE Step 1. Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials and/or workmanship. If the problem is a result of defects in materials and/or workmanship North American Electric, Inc. will pay a reasonable inspec on fee for the inspec on that will included a wri en warranty report that describes the cause of failure along with photographs that show, in detail, what is described in the warranty report. Step 2. Contact our warranty department and be prepared to provide the following informa on and documenta on: 1) Serial Number 2) Model Number 3) Inspec on / Failure Report 4) Photographs showing the cause of failure 5) Es mated cost of repair Visit our website at www.naemotors.com for detailed informa on and instruc ons on the following: 1) Freight Damage and Claims Policy and Procedure 2) Return Material Authoriza on (RMA) Policy and Procedure Step 3. Our warranty department will determine whether to replace or repair the defec ve product. DO NOT repair any product without prior wri en purchase order from North American Electric, Inc. Always be sure to take clear photographs before beginning any repair work. 16

Start Up and Installa on Requirements The So Starter and VFD panel must be installed by a NAE Authorized or Cer fied Installer. A NAE Chassis Exchange Program Installa on Form must be filled out and submi ed to North American Electric, Inc. within 17 NO HASSLE CHASSIS EXCHANGE PROGRAM WARRANTY WITH LIGHTNING & SURGE PROTECTION Terms & Condi ons of Sale NO HASSLE CHASSIS EXCHANGE PROGRAM North American Electric s (aka NAE) No Hassle Chassis Exchange Program is a revolu onary motor control panel warranty designed to keep you up and running. Our No Hassle Chassis Exchange Program makes it easy to exchange your So Starter or VFD chassis without needlessly having to purchase a chassis while at the same me minimizing unplanned down me. Should your So Starter or VFD panel s chassis fail, NAE will promptly ship a new or refurbished chassis for the dura on of your selected warranty. Your en re panel is further protected with our three (3) year Bumper to Bumper coverage, even protec ng against line side anomalies such as lightning, surges and severe overvoltage events, and load side anomalies such as single phasing, phase reversal and voltage unbalance. Your panel must be installed by an NAE Authorized or Cer fied Installer to qualify. NO HASSLE CHASSIS EXCHANGE PROGRAM WARRANTY with LIGHTNING & SURGE PROTECTION So Starter and VFD panel packages must include Lightning & Surge Protec on to be eligible for our No Hassle Chassis Exchange Program Warranty. As an op on, you can purchase Lightning & Surge Protec on (LIST Price = $949) which will automa cally include our No Hassle Chassis Exchange Program Warranty on any So Starter or VFD panel packages. Lightning & Surge Protec on Lightning & Surge Protec on covering momentary anomalies such as: Line side events: lightning, surges and severe overvoltage Load side events: single phasing, phase reversal, and voltage unbalance NOTE: This protec on is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct ligh ng strikes to the motor control panel. The panel must be properly grounded. The No Hassle Chassis Exchange Program Warranty must be ac vated (See Obliga ons of the Customer ). If the panel is installed by a North American Electric Authorized Installer, then the warranty period shall be three (3) years from the date of delivery. If the panel is installed by a North American Electric Cer fied Installer, then the warranty period shall be three (3) years from the date of installa on. Our Chassis Exchange Program Warranty benefits include: Bumper to Bumper coverage of the en re panel package from 0 36 months from date of delivery Repair, replacement or credit of a panel package that is found to be defec ve due to faulty manufacture, design and/or defec ve materials Factory installed op ons sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work Lightning & Surge Protec on covering momentary anomaly events: Line Side: Lightning, Surge and Severe Overvoltage Load Side: Single Phasing, Phase Reversal and Voltage Unbalance No Hassle Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air, Second Day Air and Hot Shot Service are available for an addi onal charge) OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panel s aforemen oned No Hassle Chassis Exchange Program warranty to provide addi onal protec on for up to six (6) years by selec ng one of the following: Extended Warranty for the Chassis Only An Extended Warranty for the Chassis Only may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3% of the total purchase price of the panel per year for years four (4), five (5) and six (6). Extended Bumper to Bumper Warranty for the En re Panel An Extended Bumper to Bumper Warranty for the en re panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5% of the total purchase price of the panel per year for years four (4), five (5) and six (6). OBLIGATIONS OF THE CUSTOMER NAE s revolu onary No Hassle Chassis Exchange Program with Lightning & Surge Protec on is intended for So Starter and VFD panels which can be shipped to and repaired u lizing our authorized chassis repair facility (See No Hassle Chassis Exchange Program Claim Procedures). The customer is required to have an Authorized or Cer fied Installer ac vate this warranty by following our Start Up and Installa on Requirements.

fi een (15) days from the date the panel is installed and prior to any claim or the No Hassle Chassis Exchange Program Warranty with Lightning & Surge Protec on is considered void. Cer fied Installer classes are offered in Hernando, Mississippi. You can find updated informa on on the following topics at the link listed below: How to become a NAE Authorized Installer How to become a NAE Cer fied Installer NAE Chassis Exchange Program Installa on Form NAE University Class Schedule www.naemotors.com/chassisexchangeprogram No Hassle Chassis Exchange Program Claims Procedures: What You Must Do 1) Contact North American Electric, Inc. and open a claim for your failed So Starter or VFD chassis. Refer to our Electric Motor Controls Warranty Claim Procedure 2) Issue a purchase order for a replacement So Starter or VFD chassis 3) Return the defec ve chassis to North American Electric, Inc. for warranty inspec on 4) If the failure is due to defec ve materials and/or workmanship then NAE will credit you for the replacement chassis 5) If the failure is not due to defec ve materials and/or workmanship then you will be responsible for payment of the replacement invoice WARRANTY EXCLUSIONS 1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defec ve product 3) Any costs and expenses resul ng from onsite repair 4) Travel costs and expenses resul ng from onsite repair 5) Dismantling, installa on or commissioning of the product 6) Defects caused by normal wear and tear or external factors, such as: a. Incorrect grounding of the panel b. Incorrect installa on c. Incorrect opera on and maintenance d. Improper connec on to peripheral or third party products e. Use of unauthorized spare parts f. Modifica on or repair performed by a person not authorized by North American Electric, Inc. g. Natural disaster h. Connec on to irregular voltage sources i. Opera on outside the usage of parameters stated in the user s manual j. Lightning & Surge Protec on that is disabled 7) Peripheral items and op ons not purchased with the drive 8) Cost of freight to ship product from installa on to North American Electric, Inc. repair facility and back 9) Customs du es and taxes This No Hassle Chassis Exchange Warranty Protec on is being offered by North American Electric, Inc. The manufacturer of the chassis is not liable for any claims made under this warranty. All claims should be made directly with North American Electric, Inc. 18

CONTINUING EDUCATION North American Electric s continuing education courses were created with you in mind to provide information, tools, technical support, and training to sell, install, and support low volt CONTINUING EDUCATION NAE University offers professional, comprehensive, and educational programs including: Sales/Product Training Electric Motors Electric Motor Controls Motor Start Up / Basic Programming of Low Voltage AC Drives Maintenance and Troubleshooting Training Electric Motors Electric Motor Controls We provide in depth, hands on training at our headquarters in Hernando, Mississippi. We also provide on site training at your location as well as internet courses and webinars. For more information, please visit our website at www.naemotors.com, or contact us at 800 884 0404.

508A Cer fied General Purpose Motors & More 800.884.0404 sales@naemotors.com naemotors.com P.O. Box 130 350 Vaiden Drive Hernando, MS 38632