DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Similar documents
RXTH DUAL ROOM SENSOR / SWITCH

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RXTP ROOM TEMPERATURE

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

InBin-P Pressure switches from 5 Pa Pa

Instruction Manual. T3110 T3110L T3110Ex

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Operating instructions. Speed monitor D / / 2014

MU110-6U. Analog output module 6 channel. User guide

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

InCos-P Pressure sensor 20 Pa Pa

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Carbon Monoxide Sensor - ModBus

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Technical data. Safety notes. Product features

Voltage Transducer UMT516 / MT516

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

PSBOC PSBOC 27,6V/5,5A/OC

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

OZONE SWITCH Model OS-6. OS-6 Features

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

IF-80x Outdoor Terminal

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Priva Blue ID Digital input module DI4/DI8/DI16

Multifunction Transducer MT440

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Priva Blue ID Relay output module DOR4/DOR8

Communicative controller for VAV systems

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

TRANSDUCER T4311, T4411

Operating instructions. Switching amplifier DN0210 DN / / 2015

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Installation, Operation and Maintenance Manual

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Priva Blue ID Analogue output module with manual override AO2m/AO4m

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

Overview of types. Technical data

Page 1 MRK-D-0011, V1.1 Aeroqual SM50 User Guide

Motor Control and Protection Unit M10x AO Module User Guide

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

CMSA-100 Manual. Cinema Media Server Automation

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

EE160 - Humidity and Temperature Transmitter for HVAC Applications

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Switched Mode Power Supply Operating manual PAP800

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Ultra Slim Relays 24

thanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet

mark150s mark150/485s DDC controllers Summary

TCNM-ACBB1 Installation Manual

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Priva Blue ID Communication module RS485 SC44

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

RTD-W Installation Instructions


MC 11 EB-2 Power supply cabinet with external bus, AC version

LC35SE-CC LOOP

LC51SE-CC LOOP

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Small distributed I/O module

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Features and Benefits. Certifications

Buffered Power Supply PS-30DR v1.0

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

IMIO100 IMIO105. DDC controllers. Summary

Conductive Level Controller

CDD4 Duct Carbon Dioxide Transmitter

Transcription:

DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions

Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND CONNECTIONS 5 MOUNTING & OPERATING INSTRUCTIONS IN STEPS 6 MODBUS REGISTER MAPS 9 VERIFICATION OF INSTALLATION INSTRUCTIONS 11 TRANSPORT AND STOCK KEEPING INFORMATION 11 WARRANTY INFORMATION AND RESTRICTIONS 11 MAINTENANCE 11 MIW--EN-000-29 / 09 / 2015 www.sentera.eu 2-11

SAFETY AND PRECAUTIONS Read all information, the datasheet, mounting instructions and wiring scheme before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications to the product are not permitted. The product must not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Chemical vapours with high concentration in combination with long exposure times can affect the product performance. Make sure the work environment is as dry as possible; check for condensation spots. All installations shall comply with the local health and safety regulations and local electrical codes. This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is life. Always disconnect the power source before connecting the power cables, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use wires with appropriate size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and disposed in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW--EN-000-29 / 09 / 2015 www.sentera.eu 3-11

PRODUCT DESCRIPTION ARTICLE CODES The series are dual duct sensors / switches which measure temperature and relative humidity. For each, there are 4 pre-defined ranges acting as measurement windows plus 1 user definable range. These units are equipped with Modbus RTU (RS485) communication and have an analogue and a relay output for each measuring unit. INTENDED AREA OF USE TECHNICAL DATA STANDARDS Code Supply Connection G 15 24 VAC ± 10 % 3 - wire 18 34 VDC F 18 34 VDC 4 - wire Monitoring and maintaining temperature and relative humidity in ducts 2 analogue outputs: 0 10 VDC / 0 20 ma 2 relay outputs: C/O (230 VAC / 2 A) Power consumption: no load: max. 40 ma full load: max. 80 ma Load resistance: 0 10 VDC mode > 500 Ω 0 20 ma mode < 500 Ω Selectable temperature ranges: 0 30 C / 10 40 C / 20 50 C / 0 50 C Free selectable temperature range via Modbus: 0 50 C Selectable rel. humidity ranges: 20 90 % rh / 0 60 % rh / 0 80 % rh / 0 100 % rh Free selectable rel. humidity range via Modbus: 0 100 % rh 2 selectable switching points: by trimmers or via Modbus Fixed temperature hysteresis: 2 C Fixed rel. humidity hysteresis: 5 % rh Enclosure and tubing: ASA, grey (RAL9002) IP54 (according to EN 60529) Fixing flange: PE, black (RAL9004) IP20 (according to EN 60529) Operating ambient conditions: temperature: 0 50 C rel. humidity: < 100 % rh (non-condensing) Storage temperature: -40 60 C Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC: EN 61326 WEEE Directive 2012/19/EU RoHs Directive 2011/65/EU MIW--EN-000-29 / 09 / 2015 www.sentera.eu 4-11

OPERATIONAL DIAGRAMS Temperature Relative humidity Analogue output 1 [VDC] 10 Analogue output 2 [VDC] 10 0 min. max. 50 T, [ºC] range range 0 min. max. 100 rh, [%] range range Relay output 1 rel on Relay output 2 rel on rel off 0 SP-hyst SP 50 T, [ C] rel off 0 SP-hyst SP 100 rh, [%] WIRING AND CONNECTIONS Vin Positive DC voltage / AC ~ GND Ground / AC ~ A Modbus RTU (RS485) signal A /B Modbus RTU (RS485) signal /B Ao1 GND Ao2 GND NO1 COM1 NC1 NO2 COM2 NC2 Connections Analogue output (0 10 VDC / 0-20 ma) Ground Analogue output (0 10 VDC / 0-20 ma) Ground Normally open contact Common contact Normally closed contact Normally open contact Common contact Normally closed contact Cable cross section: max. 1,5 mm 2 Cable gland clamping range: 5 10 mm MIW--EN-000-29 / 09 / 2015 www.sentera.eu 5-11

MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the duct sensor / switch read carefully Safety and Precautions. 1. Open the cover and insert the connecting cables through the cable gland of the unit. 2. Do the wiring according to the wiring diagram (see Fig. 1) using the legend information from section Wiring and connections. Fig. 1 Wiring and connections Analogue output 1 0 10 VDC / 0 20 ma Analogue output 2 0 10 VDC / 0 20 ma Power supply 15 24 VAC ± 10% / 18 34 VDC Modbus RTU A /B Relay output 1 Normally open Common Normally closed Relay output 2 Normally open Common Normally closed 3. Check if your unit starts or terminates the network (see Example 1 and Example 2). If it does not, remove the JP1 (NBT) jumper (see Fig. 2). Example 1 Example 2 Fig. 2 Network bus resistor jumper Slave 1 NBT NBT RX ТX NBT Master NBT RX ТX NBT Slave 2 Master Slave 1 Slave 2 Slave n Slave n If an AC power supply is used with any of the units in a Modbus network, the GND terminal should NOT BE CONNECTED to other units on the network or via the CNVT USB-RS485 converter. This may cause permanent damage to the communication semiconductors and / or the computer! MIW--EN-000-29 / 09 / 2015 www.sentera.eu 6-11

4. Adjust the standalone settings: 4.1 To select the analogue output modes, use jumper JP4 for temperature and jumper JP5 for rel. humidity. (See Fig. 3 Analogue output selection jumpers.) 4.2 To select a temperature range, use jumper JP2. To select the rel. humidity range, use jumper JP3. (See Fig. 4 and the enclosed information.) Fig. 3 Analogue output selection jumpers Fig. 4 Sensor range selection jumpers 5 4 3 2 1 0 30 C 20 90 % rh 5 4 3 2 1 10 40 C 0 60 % rh 5 4 3 2 1 20 50 C 0 80 % rh 5 4 3 2 1 JP2 JP3 0 50 C 0 100 % rh JP2 JP3 JP2 JP3 JP2 JP3 0 10 VDC 0 20 ma 4.3 To reset the Modbus settings, put and hold jumper P1 for 20 seconds. (See Fig. 5 Modbus reset jumper.) 4.4 To select the temperature setpoint for relay 1 switching, use trimmer VR1. To select the rel. humidity setpoint for relay 2 switching, use trimmer VR2 (see Fig.6). Fig. 5 Modbus reset jumper Fig. 6 Setpoint selection jumpers 5. Mount the unit outside a duct with the tube mounted inside the duct but fixed outside it. 5.1 Drill a tight-sealing hole according the correct tube section (Ø 13 mm). 5.2 Fix the flexible flange (Fig. 7) on the duct outer surface using the selfdrilling screws, delivered with the unit. Then install the tube inside the flexible flange. Mind the airflow direction. 5.3 Install the tube at the desired depth in the duct using the screw in the flexible flange. 5.4 Install and connect the cables with a drip loop. You can also fix the unit outside the duct via the mounting holes and as per the drawing shown in Fig. 8. MIW--EN-000-29 / 09 / 2015 www.sentera.eu 7-11

Fig. 7 Fixing flange Fig. 8 Mounting dimensions 2x Ø 5 70 4x Ø 4,5 66 60 Installation of the unit near high EMI-emitting devices may lead to faulty measurements. Use shielded wiring in areas with high EMI. Keep 15 cm (5,9 ) minimal distance between the sensor lines and the 230 VAC power lines. Always use two separate transformers: one for the sensor and one for the controller. 6. Close the enclosure and fix the cover. 7. Switch on the power supply. Do not exceed the maximum power supply rating! Measure before installation! Unregulated 24 VAC supply units provide higher nominal output voltage and activate the integrated fuse protection. If a G-type article is using the same AC power supply source (transformer) as F-type article, a SHORT CIRCUIT may result when the power supply and analogue signal terminals are connected to the same common ground! In this case always connect different article types to separate AC transformers or use the same article version. 8. Customise the factory settings to the desired ones, through 3SModbus software (if necessary). For the default factory setting see Table Modbus register maps. MIW--EN-000-29 / 09 / 2015 www.sentera.eu 8-11

MODBUS REGISTER MAPS INPUT REGISTERS Data type Description Data Values 1 Temperature level Actual temperature level 50 50,0 C 2 Relative humidity level un Actual relative humidity level 1.00 100,0 % rh 3 Dew point Calculated dew point 20 20,0 C 4-10 Reserved, returns 0 11 12 13 14 Temperature output value for temperature measurement Relative humidity output value for relative humidity measurement Relay 1 status, temperature setpoint Relay 2 status, relative humidity setpoint Value of the analogue output for temperature - Ao1 0 1.000 Value of the analogue output for relative humidity - Ao2 0 1.000 15 Temperature range 16 Relative humidity range 17 18 19 20 21 22 Temperature setpoint relay 1 Relative humidity setpoint relay 2 Temperature hysteresis relay 1 Relative humidity hysteresis relay 2 Temperature setpoint out of range Relative humidity setpoint out of range 23-29 Reserved, returns 0 Relay 1 status for the temperature setpoint. When it is On, the contact between COM1 and NO1 is closed. Relay 2 status for the relative humidity setpoint. When it is On, the contact between COM1 and NO1 is closed. Temperature working range selected by jumper or according to holding registers 7, 11, 13 and 14. Relative humidity working range selected by jumper or according to holding registers 7, 12, 15 and 16. 0 1 0 1 1 5 1 5 1.00 1.00 2 = 3 = 4 = 5 = Off On 0 % 100 % 0 % 100 % Off On Off On 0 30 C 10 40 C 20 50 C 0 50 C Custom 20 90 % rh 2 = 0 60 % rh 3 = 0 80 % rh 4 = 0 100 % rh 5 = Custom Temperature setpoint relay 1 selected by trimmer or holding registers 7 and 17 0 500 50 50,0 C Relative humidity setpoint relay 2 selected by trimmer or holding registers 7 and 18 0 1.000 1.00 100,0 % rh Temperature hysteresis for relay 1 switching 2 2,0 C Relative humidity hysteresis for relay 2 switching 5 5,0 % rh Flag that shows if the temperature setpoint is out of the working range 0 1 Flag that shows if the relative humidity setpoint is out of the working range 0 1 No Yes No Yes 30 Sensor communication lost un Flag that shows if the communication with the sensor module is lost 0 1 No Yes MIW--EN-000-29 / 09 / 2015 www.sentera.eu 9-11

HOLDING REGISTERS Data type Description Data Default Values 1 Device slave address un Modbus device address 1 247 1 2 Modbus baud rate un Modbus communication baud rate 1 4 2 3 Modbus parity mode un Parity check mode 0 2 1 4 Device type un Device type (Read only) X=1036 5 HW version un Hardware version of the device (Read only) XXXX 0 x 011 HW version 1.10 6 FW version un Firmware version of the device (Read only) XXXX 0x012 FW version 1.20 7 Operating mode un 8 Output overwrite un 9-10 Reserved, returns 0 11 Temperature range 12 Relative humidity range 13 14 15 16 17 18 Minimum custom temperature range Maximum custom temperature range Minimum custom relative humidity range Maximum custom relative humidity range Temperature setpoint relay 1 Relative humidity setpoint relay 2 19-20 Reserved, returns 0 21 22 Analogue output 1 overwrite value for temperature, Ao1 Analogue output 2 overwrite value for relative humidity, Ao2 23-30 Reserved, returns 0 Enables Modbus control and disables the jumpers and trimmers Enables the direct control over the outputs. Always settable. Active only if holding register 7 is set to 1. Selects the temperature working range. Always settable. Active only if holding register 7 is set to 1. Selects the relative humidity working range. Always settable. Active only if holding register 7 is set to 1. Minimum value of the custom temperature range. Always settable. Active only if holding register 7 is set to 1 and register 11 is set to 5. Maximum value of the custom temperature range. Always settable. Active only if holding register 7 is set to 1 and register 11 is set to 5. Minimum value of the custom relative humidity range. Always settable. Active only if holding register 7 is set to 1 and register 12 is set to 5. Maximum value of the custom relative humidity range. Always settable. Active only if holding register 7 is set to 1 and register 12 is set to 5. Selects the setpoint for the temperature relay switching. Always settable. Active only if holding register 7 is set to 1. Selects the setpoint for the relative humidity relay switching. Always settable. Active only if holding register 7 is set to 1. Overwrite value for the temperature analogue output. Always settable. Active only if holding registers 7 and 8 are set to 1. Overwrite value for the relative humidity analogue output. Always settable. Active only if holding registers 7 and 8 are set to 1. If you want to find out more about Modbus over serial line, please visit: http://www.modbus.org/docs/modbus_over_serial_line_v1_02.pdf 0 1 0 0 1 0 1 5 1 1 5 1 2 = 3 = 4 = 2 = 9.600 19.200 38.400 57.600 8N1 8E1 8O1 Standalone mode Modbus mode 2 = 3 = 4 = 5 = 2 = 3 = 4 = 5 = Disabled Enabled 0 30 C 10 40 C 20 50 C 0 50 C Custom 20 90 % rh 0 60 % rh 0 80 % rh 0 100 % rh Custom 0 Max 0 10 10,0 C Min 500 500 50 50,0 C 0 Max 0 20 20,0 % rh Min 1.000 1.000 1.00 100,0 % rh 0 500 250 25 25,0 C 0 1.000 500 50 50,0 % rh 0 1.000 0 0 1.000 0 1.00 1.00 0 % 100 % 0 % 100 % MIW--EN-000-29 / 09 / 2015 www.sentera.eu 10-11

VERIFICATION OF INSTALLATION INSTRUCTIONS Check if both LEDs (LEDTX and LEDRX) blink after you switch on your unit. (See Fig. 9 Communication detection indication.) If they do, your unit has detected Modbus network. If they do not, check the connections again. Fig. 9 Communication detection indication The status of both LEDs (LEDTX and LEDRX) can be checked only when the unit is energised. Take the relevant safety measures! TRANSPORT AND STOCK KEEPING INFORMATION Avoid shocks and extreme conditions; stock in original packing. WARRANTY INFORMATION AND RESTRICTIONS MAINTENANCE Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. In normal conditions this product is maintenance-free. If soiled, clean with a dry or dampish cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW--EN-000-29 / 09 / 2015 www.sentera.eu 11-11