Protected VARAN Digital Mixed Module PVDM 086

Similar documents
VARAN Digital Combined Module VDM 086

VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network

DIAS Interface Module VARAN DIV 511

VARAN Splitter PROFINET VSP 044

VARAN Splitter Module VSV 041

VARAN Splitter Module VSV 043

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

VARAN Client Board VEB 011/012 Versatile Automation Random Access Network

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))

VARAN Splitter PROFINET VSP 042

VARAN-INTERFACE VAC 012

C-IPC Expansion VM 052 (C-IPC VARAN Manager 052) Versatile Automation Random Access Network

VI 021 S-DIAS VARAN Control Module

Expansion Module HZS 541-1S

C-DIAS Digital Input Module CDI 161 with 16 inputs

DM 161 S-DIAS Digital Mixed Module

TO 161 S-DIAS Digital Output Module

C-DIAS EtherNet/IP Slave CIP 022

C-DIAS Temperature sensing module CAI x temp. inputs C 8 x digital outputs +24V

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

GFK-2415A March Type of sensor connection

C-DIAS Serial Interface CSI 021

Internal Buffer/Boiler Module HZS 534

AO 081 S-DIAS Analog Output Module

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

ISE 021 S-DIAS Interface Module RS232 / RS485

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

HZS Internal Controller Expansion

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

VersaMax IP I/O Module

VersaMax IP Input Module

to 12a Added Standard and Electrical requirements for UL table 1.1

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

RO 051 S-DIAS Relay Output Module

C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Ha-VIS mcon 3000 Next Generation Introduction and features

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

TSY 041 Training System Extension Motion

AS-i 3.0 Motor modules

TN-5308 Quick Installation Guide

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

TCNM-ACBB1 Installation Manual

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

EMC-Compatible Installation of the Electric Cabinet

GS202 Encoder Switch

AI 046 S-DIAS Analog Input Module

Digital Modules AS-i in IP20, 22,5 mm

TM241CE40R controller M IO relay Ethernet

SI 021 S-DIAS SSI Interface Module

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

JUMO mtron T Measuring, Control, and Automation System

Operating instructions. Switching amplifier DN0210 DN / / 2015

C-DIAS Analog Module CAO 086 For eight ±10 V Outputs

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

SK TU4-IOE-M12-C Part Number

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

HEC. General Operating, Maintenance and Installation Manual

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

Micropulse Transducers

Keyboard Unit Sigmatek

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CE40R controller M IO relay Ethernet

DX561 Digital Input/Output Module

AS-Interface I/O Module

Industrial Ethernet Switch

BNI PNT Z015. IP67 Modules 16 Input User s Guide

TM221CE24R controller M IO relay Ethernet

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

DC562, digital input/output module,

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

Fork sensors and optical windows

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

TM221CE40R controller M IO relay Ethernet

DI561 Digital Input Module

AS-i 3.0 motor module

AO561 Analog Output Module

PC 521 Data Recording PC

B&R X67_IO_System_V3.14_E. X67 - System

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

Analog Modules AS-i, IP67, M12

PTC-101 Quick Installation Guide

DC561, digital input/output module,

TM3AI4 module TM3-4 analog inputs

IMC-21 Quick Installation Guide

PTC-101-M12 Hardware Installation Guide

170 ADI VDC - 16 Pt. Discrete Input Module Base

LVX Control Unit. Features:

AI561 Analog Input Module

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

ICA 012 S-DIAS Interface Module CAN

Transcription:

PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that are back readable and therefore can also be used as inputs. The outputs are short circuit protected. There are also diverse diagnostic functions available in this module: The status of the outputs is back readable. Each I/O socket is monitored for current surges in the sensor supply. The status is shown with red LEDs and can be read back. Input filters are provided to suppress noise in the signal lines. Through the VARAN-Out port, the VARAN bus can be configured in a linear structure. 27.05.2014 Page 1

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 Technical data Interfaces Interfaces 1x VARAN-In (M12) 1x VARAN-Out (M12) (maximum length: 100 m) Digital Outputs Number of outputs 8 Short circuit protected Back readable Maximum allowed continuous current / channel Maximum total current per group of 4 (I/O 1 4 or 5 8) Maximum total current (all 8 channels) Voltage drop over supply (output active) Residual current of output (inactive) Switch-on delay Switch-off delay Status display yes yes 2 A 2 A 4 A (100 % switch-on duration) 1 V 1 ma <200 s <200 s LEDs yellow Page 2 27.05.2014

Digital Inputs (back readable output) PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Number of inputs 8 Input voltage typically +24 V maximum +30 V Sensor supply current limit maximum 100 ma per IO socket Signal level low: <4.5 V high: >+14 V Switch threshold Input voltage Input delay Status display typically +11 V typically 5 ma at +24 V typically 5 ms LEDs yellow Electrical requirements Supply voltage bus I/O supply 18-30 V DC 18-30 V DC Current consumption of bus supply typically 85 ma maximum 100 ma Current consumption of I/O supply depends on the load of the digital outputs and the current capacity on the sensor supply: maximum 4 A 27.05.2014 Page 3

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 Not more than 20 modules should be connected in series! The supply for the entire electronics is integrated into the VARAN bus. Outputs X3 X6 are powered over the X7 supply. When using I/Os X3 X6 as inputs for encoders or sensors that do not draw power from the electronics must be supplied through X7, due to the internal wiring. Otherwise it could lead to back supply and therewith damage to the electronics. Miscellaneous Article number 14-108-086 Software macro PVDM0850_IM Hardware version 1.x Page 4 27.05.2014

Environmental conditions PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Storage temperature -20 +85 C Operating temperature 0 +60 C EMV stability according to EN 61131-2 Shock resistance EN 60068-2-27 150 m/s² Protective system EN60529 IP67 Important notice If an M12 connector is not used, then protective covers are recommended to protect against contamination. Srew Erni (Art.No: 374343): Nut Erni (Art.No: 374342): 27.05.2014 Page 5

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 Mechanical Dimensions Page 6 27.05.2014

Connector layout PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 X1 VARAN IN X2 VARAN OUT X3 I/O X4 I/O X5 I/O X6 I/O X7 Supply 27.05.2014 Page 7

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 X1 VARAN-In (M12 plug, 8-pole type A) Pin Function 1 n c 2 TX+ 3 TX- 4 n c 5 RX+ 6 GND 7 +24 V bus supply 8 RX- X2 VARAN-Out (M12 plug socket, 8-pole type A) Pin Function 1 n c 2 TX+ 3 TX- 4 n c 5 RX+ 6 GND 7 +24 V bus supply 8 RX- X3 X6 I/O (M12 plug socket, 5-pole type A) Pin Function 1 +24 V sensor supply 2 Signal B 3 GND 4 Signal A 5 Earth (Cable shielding) X7 Supply (M12 plug, 5-pole type A) Pin Function 1 GND 2 GND 3 I/O supply 4 +24 V bus supply 5 Earth (Cable shielding) Page 8 27.05.2014

PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Status LEDs LED No. Color Function 1 green VARAN IN Link yellow VARAN IN ACTIVE 2 green VARAN OUT Link yellow VARAN OUT ACTIVE 3 green Total Diagnosis STATUS OK red Total Diagnosis STATUS ERROR 4 red Short circuit in the supply of I/Os 7+8 5 yellow I/O 8 active 6 yellow I/O 7 active 7 red Short circuit in the supply of 5+6 8 yellow I/O 6 active 9 yellow I/O 5 active 10 red Short circuit in the supply of 3+4 11 yellow I/O 4 active 12 yellow I/O 3 active 13 red Short circuit in the supply of 1+2 14 yellow I/O 2 active 15 yellow I/O 1 active 16 green +24 V DC 17 green +24 V DC I/O supply 27.05.2014 Page 9

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 General Information on the Digital Outputs All 8 outputs are supplied from a common +24 V connection. The cross sectional area of the +24 V and the 0 V supply must be designed for the maximum output current of a group. Caution! If inductive loads are not provided with predective circuits, a high spike current flows over the 0 V line since the internal predection circuit dissipates spike voltages against 0 V. With an incorrect length or too thin a 0 V line can lead to undesired responses from outputs of the affected modules. Turning off the +24 V supply turns off the outputs. In this case, the output LEDs show the actual status of the outputs and not the status given by the CPU. A voltage cannot be applied to an output whose supply voltage exceeds 0.7 V. All outputs are predected internally against +24 V. The disconnection of inductive loads is limited to 24 V as shown in the graph below, however, an additional predective circuit (freewheeling diode) connected directly to an inductive load is recommended to avoid system disruptions through voltage spikes (cross talk over analog lines). This, however, results in the internal voltage limit being effective to only 0.6 V. Disconnection of inductive loads: Page 10 27.05.2014

PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Addressing The input module is processed by the operating system automatically (process image). Address Access Function 16#00 READ BYTE Back readable inputs 1..8 16#01 READ/WRITE BYTE Reserved 16#02 WRITE BYTE Output 1..8 16#03 READ/WRITE BYTE Reserved 16#04 READ/WRITE BYTE Bit 0 Output error status 1+2 Bit 1 Output error status 3+4 Bit 2 Output error status 5+6 Bit 3 Output error status 7+8 Bit 4 7 Reserved Control Address Mapping Address (hex) Size (Byte) Description 0000 264 SPI Master 0140 64 Reserved 0180 64 VARAN Configuration registers 27.05.2014 a Page 11

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 VARAN Recommended Shielding The VARAN real-time Ethernet bus system offers robust performance in harsh industrial environments. Through the use of IEEE 802.3 standard Ethernet physics, the potential between an Ethernet line and sending/receiving components is kept separate. The VARAN Manager resends messages to a bus participant immediately when an error occurs. It is principally recommended that the shielding guidelines below be followed. For applications in which the bus line is run outside the control cabinet, correct shielding is required. This is especially important, if due to physical requirements, the bus lines must be placed next to sources of strong electromagnetic noise. It is recommended that whenever possible, to avoid wiring VARAN-Bus lines parallel to power cables. SIGMATEK recommends the use of CAT5e industrial Ethernet bus lines. For the shielding variants, an S-FTP bus line is recommended, which is a symmetric, multi-wire cable with unshielded pairs. For the total shielding, a combination of foil and braiding is used; it is recommended that an unvarnished variant be used. Page 12 27.05.2014

PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 1. Wiring from the Control Cabinet to an External VARAN Component If the Ethernet lines are connected from a VARAN component to a VARAN node outside the control cabinet, the shielding should be placed at the entry point to the control cabinet housing. All noise can then be deflected from the electronic components before reaching the module. 27.05.2014 Page 13

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 2. Wiring Outside of the Control Cabinet If a VARAN bus cable must be placed outside of the control cabinet only, no additional shield connection is required. This requires that only IP67 modules and connectors be used. These components are very robust and noise resistant. The shielding for all sockets in IP67 modules are internally connected to common bus or electrically connected to the housing, whereby the deflection of voltage spikes does not flow through the electronics. Attention! The earth bus for the PVDM 086 has to be connected to both metal sleeves for the mounting screws (upper right and lower left) in the plastic housing. A conductive path must be provided. Page 14 27.05.2014

PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 3. Shielding for Wiring Within the Control Cabinet Sources of strong electromagnetic noise located within the control cabinet (drives, Transformers, etc.) can induce interference in a VARAN bus line. Spike voltages are deflected over the metallic housing of a RJ45 connector. Noise is conducted through the control cabinet housing without further action from the electronic components To eliminate sources of noise during data transfer, it is recommended that the shielding from all electronic components be connected within the control cabinet. 27.05.2014 Page 15

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 4. Connecting Noise-Generating Components With the connection of power components that generate strong electromagnetic noise, it is also critical to ensure correct shielding. The shielding should be placed before a power component (or a group thereof). Page 16 27.05.2014

PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 5. Shielding Between Two Control Cabinets If two control cabinets must be connected over a VARAN bus, it is recommended that the shielding be located at the entry points to both cabinets. Noise can thereby be kept from reaching the electronics within the control cabinet. 27.05.2014 Page 17

PROTECTED VARAN DIGITAL MIXED MODULE PVDM 086 Page 18 27.05.2014