PRESSURE TRANSDUCER K611P-B

Similar documents
PRESSURE TRANSDUCER Setra 276

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

NRG 200M Wind Vane Authors:

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Trend-1 Vibration Data Logger. User Manual

Engineering Note: EN0047 Commissioning a Hydro-Probe with a Command Alkon EZCal Station

SX100A. Features. Typical Applications. Description

DATA LOGGER (Version V1.3)

SX15GD2. Features. Typical Applications. Description

SX01DN. Features. Typical Applications. Description

DaqLink Calibration Procedure

T2214. Instruction Manual

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

Altimeter / Barometer Module SMD500 ultra low power, low voltage

RST INSTRUMENTS LTD.

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

DP DP2500 DP0250

NOVALYNX CORPORATION MODEL 110-WS-25 MODULAR WEATHER STATION INSTRUCTION MANUAL

Draw wire sensors, draw wire sensors for displacement, position

Appendix A - Calibration Data Sheets for Pika T701 Test Instruments Primary Anemometer Pre-Test Calibration

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

Technical data. Your advantages

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Manual DTM Digital Pressure Transmitter

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

The SolarTrak Prospector. CR-1000 Datalogger

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

Mounting DIGITAL DISPLAY

NRG INSTRUCTIONS Using the SPN1 Pyranometer on Symphonie Loggers

Temperature sensors TTM series. Miniature transmitters

IK4A (with ONDA technology)

EDX-10 Series. Compact Recording System

HTD series digital differential pressure sensors

HygroClip DIGITAL Humidity and temperature probe

Trademark and Copyright Information Warranty Installation Guidelines (Read Before Installing) Section 1: Introduction...

Twist-lock style " or 2" Tri-Grip TM Fitting. PX429S15-015GV, shown smaller than actual size.

MELT PRESSURE TRANSMITTERS IE SERIES WITH CURRENT OUTPUT AND PLc VERSION

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Product description for ED1600 generic Sigfox Module

ZBXYAF Oxygen sensor control circuit board

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

User's Manual IDAX Support Software Version Megger Sweden AB. Released in

Distributor: Topac Inc 231 CJC Highway Cohasset MA Tel Fax

NO - NPN PSC10-30GI70-E PSC10-30GI70-E-V1 NO - PNP PSC10-30GI70-E2 PSC10-30GI70-E2-V1

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

ES1 Infrared Temperature Sensors Were Discontinued; Replace with ES1-N Series Coming September 2017

SensDev UG, based in Burgstaedt, Germany, is a Silicon Pressure Sensor supplier. Ranges are 50Pa to 4MPa, 10μL/s to 1000m³/h.

Corning Varioptic C-C-39N0-160 Auto Focus Lens Module

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

Model 305e OEM CO 2 concentration sensor

Flexible temperature transmitter and sensor

STYLITIS-10 INSTALLATION GUIDE

NOVALYNX CORPORATION MODEL 110-WS-25 MODULAR WEATHER STATION INSTRUCTION MANUAL

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

STYLITIS-100/101 INSTALLATION GUIDE

w w w. z i g s e n s e. c o m. a u

R-DAS Tiny User s Manual

EDX-10 Series. Compact Recording System

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

PRESSURE TRANSMITTER

TECHNICAL PRODUCT DATASHEET

Draw wire sensors, draw wire sensors for displacement, position

and/or b. an optional internal Iridium satellite modem.

YSI EXO Series Multi-Parameter Water Quality Sondes

Contents. 1. Installation

Microminiature and Subminiature Gauging DVRT Quick Start Guide

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

Microminiature and Subminiature DVRT Quick Start Guide

HW4 Software version 2. Probe Adjustment function Legacy devices

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

Environdata FA ma Converter Guide

TECHNICAL DATASHEET #TDAX050000K CAN

PTU200 Transmitter. Measuring Barometric Pressure, Humidity and Temperature

GLOBAL SOLUTIONS IN ENGINEERING. Power Performance Testing

RE08A Rotary Encoder Kit

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter

Signet ph/orp Transmitter * *

QFBR-S01IN001Z. Optical Phase Interrogator. Data Sheet. Description. Features. Applications

Data Sheet. QFBR-S01IN001Z Optical Phase Interrogator. Description. Features. Applications

LVX Control Unit. Features:

OPERATION MANUAL - DS-MOD-

DATA LOGGER GEOLOGGER G8 PLUS

GMM220 CO 2. Transmitter Modules. Introduction. Mounting

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

GeoLogger Linx Series

ST-565 Inline HST Fluorometer Probe Instruction Manual

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

GS828-H. GPRS Data Logger

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Easy Arc Integration into a Simatic S7-300 Process Control System

Product Specification. CO 2 Engine K33-LP T. Sensor Module and OEM Platform. Document PSP0120. Rev 4. Page 1 (13)

IST ULTRASTAB Power Supply for high precision transducers

Air data test indicator Model CPA2501

Transcription:

PRESSURE TRANSDUCER K611P-B

Certified in Brazil by: ORDER - Nº PRESSURE RANGE ELECTRICAL SUPPLY MODEL IN EOL MANAGER K611P-B 600-1100 mbar 5 VDC K611P APPLICATION The K611P-B pressure sensor is a robust compact sensor specifically designed to meet the requirements in meteorological and wind resource assessment applications. The sensor offers high performance, easy installation and since the output is in frequency it allows the use of longer cables without any signal loss. A great advantage for wind resource assessment, where pressure sensors are regularly installed at 80 m to 140 m. The K611P-B is accurate and stable with a long term stability of less than ±1.0 mbar (specified in the full operating pressure range 0 +85 ºC). Some of the main features and advantages of the K611P-B pressure sensor: Low energy consumption (1.8mA) Wide power supply range (3.3-30V) Output range 600-1100mb* Frequency output** Competitive pricing * Can therefore be installed at any altitude above sea level ** No need to increase the sensor cable cross section for installations at heights with the consequent saving in cable. TECHNICAL DATA CHARACTERISTIC DESCRIPTION / VALUE Pressure range 600 1100 mbar Low noise 0.05 mbar in standard mode Overpressure 10000 mbar Accuracy pressure ±0.12 mbar Long term stability ±1.0 mbar, 12 months (specified in the full range operating pressure range) Supply voltage 3.3 30 VDC Input current 1.8 ma Operating temperature -40 +85 ºC Storage temperature -40 +85 ºC Weight 164 g with cable 2 m long

INSTRUCTIONS Use the following input channels on the logger to connect this sensor. See highligted input channels marked here below. The wire colors used in the connection diagram below only applies in case the cable is supplied by Kintech Engineering. For additional wiring & shielding information see the chapter IMPORTANT at the end of this dataheet. BAT ANEMOMETER INPUTS OUT DIGITAL INPUT 1 1 5V 2 3 4 5V 5 6 7 5V 8 9 10 3 2 1 8 7 6 5 4 3 2 1 SIG SIG 1 2 3 4 5 2 5 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 DIR 1 DIR 2 ANALOG INPUTS EXTRA ANALOG INPUTS DIGITAL INPUT 2 BAROMETRIC PRESSURE TRANSDUCER K611P-B DATA LOGGER EOL Zenith SENSOR PIN DESCRIPTION DATA LOGGER INPUT CHANNEL KINTECH COLOR CODES Signal Anemometer Inputs 1 Green Supply (-) Anemometer Inputs (-) Black Supply (+) Anemometer Inputs 5V Red Shield BAT GND Yellow - Green

SENSOR DIMENSIONS

HOW TO CONFIGURE THIS SENSOR IN EOL MANAGER Open EOL Manager and go to the data logger you are working on. Open the inputs tab and select the following type and model: Section: Anemometers/Frequency Type: Pressure* Model: K611P *This sensor should be configured on one of the channels in the Anemometers/Frequency in EOL Manager. Calibration values: Tick the Std Cal to use this sensors standard slope and offset. If you have an independent calibration certificate for this sensor insert the slope and offset values from this certificate. SENSOR SELECTION MODEL SELECTION DATASHEET DOWNLOAD STANDARD CALIBRATION IMPORTANT After configuring the sensor in EOL Manager make sure to upload the configuration file to your EOL Zenith data logger. See the Quick User Guide how to upload configuration files to the data logger. All sensor wire shields must be connected to the data logger GND terminal. The data logger should always be connected to a separated ground rod. Not to the lightning rod of the tower. The three 5V power supply outputs on the data logger terminals are completely independent and not associated to any of the signal inputs. The three 5V outputs can therefore be distributed according to needs. Depending on the firmware version of the logger, differents types and models should be configurated on the EOL Manager. In all cases, slope=1 and offset=600 on the EOL Manager. To store data such as Std Dev, Max and Min you should tick the corresponding boxes next to each anemometer channel when setting up your site file. Otherwise these parameters will not be stored. This pressure sensor should be connected to one of the anemometer channels on the data logger. In the example diagram shown before, the Signal wire from the sensor is connected to the ANEMOME- TER INPUTS 1. It can however be distributed on all ANEMOMETER channels according to needs. Avoid connecting the Signal wire of this sensor to the power supply. Cable recommendation: Sensor Signal cable 3x0.5mm 2 FW VERSION MODEL TYPE LOGGER DISPLAY x.46 K611P 29 mbar 1.44 hertz 28 mbar-600 0.42 hertz 28 mbar-600 other Contact Kintech support Last modified: 19.05.2017

KINTECH ENGINEERING Tel. +34 976 221 789