HostEngine 4U Host Computer User Guide

Similar documents
HostEngine 4U Host Computer User Guide

HostEngine 3U Host Computer User Guide

HostEngine 4U Host Computer User Guide

HostEngine 5URP24 Computer User Guide

Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide

Xpander Rack Mount 8 5U Gen 3 User Guide

Xpander Rackmount Elite Gen 3.0 User Guide

Xpander Desktop Elite Gen 3 User Guide

Chapter 6 Cubix SP1 Blade Server

High Performance Computing

DESERT STORM WS-TS700

M1034W Engineering Workstation

ThinkServer RD630 Photography - 3.5" Disk Bay*

AI Solution

Features. MIC-7700Q: 3 x independent displays (third display output via optional cable) MIC-7700H: 2 x independent displays Controller

(Please refer "CPU Support List" for more information.)

fit-pc Intense 2 Overview

Features. Q170: 3 x independent displays (third display output via optional cable) H110: 2 x independent displays Controller

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

EVS Series. Intel Xeon /Core i7/i5/i3 Fanless GPU Computing System with Intel C236 & NVIDIA GeForce GT K Isolated DIO.

IVH-9000 Series. 4K Isolated DIO

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

NEC Express5800/R120h-2M System Configuration Guide

FWA-6280A User Manual 1. FWA-6280A User Manual

Chapter 2 BladeStation Enclosure

GPU-Xpander Product and Part Number Guide Q2 2016

(Please refer "CPU Support List" for more information.)

(Please refer "CPU Support List" for more information.)

NVR-CV. Network Video Recorder Hot-Swappable Tray for 3.5 HDD x 4 or 2.5 HDD x 4 Gigabit Ethernet x 2 COM x 2, USB2.0 x 6. VGA x 1, DVI-D x 1

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

NEC Express5800/R120e-1M System Configuration Guide

Features. With SSD: 3 5 ~ 500 Hz, random, 1 hr/axis With 2.5" HDD: 1 5 ~ 500 Hz, random, 1 hr/axis

QuickSpecs. HP Z600 Workstation Overview

ThinkServer RD450 Platform Specifications

NEC Express5800/R120d-2M Configuration Guide

Intel IP Network Server NSI2U

Capacity driven storage server. Capacity driven storage server

Technical Specifications

Altos T310 F3 Specifications

Acer AR320 F1 specifications

RS500-E6/PS4. Configuration Guide

AMS Series. Fanless System

User Guide. User Information for barebone actinas BB212-3 used within the storage systems actinas WIN 212 / actinas LX 212 / actinas SV 212

EUR incl. 19% VAT, plus shipping. Intel WiFi, Intel WiDi! Dual Gigabit LAN! Gigabyte Features! NVMe M.2 slot!

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Dimensions. System Information. Memory. Stand mm (19.4 inches) mm (26.1 inches) Depth mm (1.4 inches) 78.2 mm (3.

(Please refer "CPU Support List" for more information.) (Please refer "Memory Support List" for more information.)

CISCO MEDIA CONVERGENCE SERVER 7825-I1

Cisco MCS 7815-I2 Unified CallManager Appliance

iosafe SERVER 5 Quick Start Guide

RCO-6000 Rugged Fanless Embedded System with LGA 1151 socket for Intel 6th Gen. (Skylake) Desktop Processor

RCO Compact Rugged Fanless System with Intel Atom E3827/E3845 or Celeron J1900

GW2000h w/gw175h/q F1 specifications

(Please refer "CPU Support List" for more information.)

Dell PowerEdge C410x. Technical Guide

Cisco MCS 7815-I2. Serviceable SATA Disk Drives

Acer AT110 F2 Specifications

RCO Rugged Fanless System w/ Intel Broadwell-U Core i5/i3 or Celeron Processor

RS500A-E6/PS4. Configuration Guide

Cisco MCS 7835-H2 Unified Communications Manager Appliance

CISCO MEDIA CONVERGENCE SERVER 7815-I1

Features. -40 ~ 60 95% humidity (non-condensing) 40 C (non-condensing) Vibration

Features. -40 ~ 60 95% humidity (non-condensing) 40 C (non-condensing) Vibration

3960 Series. XTREME Edition. The Professional s Choice. Key Features

Introducing the Cisco 1121 Secure Access Control System Hardware

iosafe BDR515 Hardware Guide

EUR incl. 19% VAT, plus shipping. Intel WiFi, Intel WiDi! Dual Gigabit LAN! Gigabyte Features! Intel Haswell!

Alienware Area-51 R5 Setup and Specifications

Most Powerful Dual LGA2011 Serverboard in 12 x10 Compact Size

Essentials. Expected Discontinuance Q2'15 Limited 3-year Warranty Yes Extended Warranty Available

iops-18 User Manual 2013 Oct V1 IBASE Technology Inc.

Entry workstation with ultra-quiet and extreme I/O performance design. Up-to-date 22nm Processors, Latest Intel Platform Ready

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Part Number Unit Descriptions

Cisco MCS 7815-I1 Unified CallManager Appliance

Acer AR320 F2 Specifications

Cisco MCS 7825-I1 Unified CallManager Appliance

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

EMC1600 Series Media Converter and Ethernet Extender Chassis

(Please refer "CPU Support List" for more information.)

NEC EXPRESS5800/R320a-E4 Configuration Guide

MD711-SU Installation Guide

1. AMD Ryzen 2nd Generation processors 2. AMD Ryzen with Radeon Vega Graphics processors 3. AMD Ryzen 1st Generation processors

Acer AT310 F2 Specifications

USER Manual ECX th Gen Intel Xeon /Core i7/i5/i3 Fanless Embedded System Workstation-grade, 10GigE LAN, Extended Temperature

RS-200-RPS-E 2U Rackmount System with Dual Intel

0B specifications 1B

Installing the IPS 4345 and IPS 4360

Operating systems supported Windows 10 Home (64-bit) Windows 10 Professional (64-bit) Ubuntu 16.04

Cisco MCS 7845-H1 Unified CallManager Appliance

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017.

GW2000h w/gw170h/d/q F1 specifications

Data Domain DD6300, DD6800, and DD9300 Systems

ESC2000 Configuration Guide

1U Device Expansion Unit Configuration Guide

Heavy Duty Fanless Touch Panel PC GOT3217W-881-PCT.

ThinkServer RD530 Photography - 3.5" Disk Bay*

Pioneer DreamMicro. Rackmount 2U Server S87 Series

Transcription:

HostEngine 4U Host Computer User Guide HostEngine 4U computer features Intel Xeon E5-2600v3 Series (Haswell) dual-processors with the Intel C612 chipset. HostEngine 4U provides four PCI Express (PCIe) Gen 3.0 x16 expansion slots. Each slot accommodates a full-height, full-length, double-wide GPU or a halfheight, half-length controller such as the Cubix Host Interface Controller (HIC) that connects to Cubix Xpander products. Each HIC connects to multiple slots within an Xpander Rackmount 8 or other Xpander products. By connecting HostEngine to GPU-Xpander Rackmount 8, you can add eight double-wide GPUs such as NVIDIA Quadro M5000 or M6000 to the HostEngine 4U computer for running Autodesk 3ds Max or Bunkspeed Shot with NVIDIA iray running on Linux or Microsoft Windows. You can also run BlackMagic Design DaVinci Resolve for Linux on HostEngine 4U computer. Connecting to Xpander Rackmount 8 also enables you to connect to GPU Compute Engines such as NVIDIA or AMD GPUs for HPC applications, virtual desktop projects or multiple Intel Xeon Phi coprocessors for parallel processing. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 1 Sales 800.829.0550 http://www.cubix.com sales@cubix.com host-engine-4u-x10drg-q-20151215

Technical Specifications Central Processing Unit (CPU) Intel Xeon E5-2600v4 Series Number CPUs 2 x R3 with identical revision, core voltage and bus (core) speed Socket 2011-pin R3 LGA Speeds / Cores / Threads 2.9GHz and lower / up to 18 cores / up to 36 threads Intel Smart Cache Up to 45MByte 64-bit computing Yes QuickPath Interconnect Up to 9.6 GigaTransfers/second (GT/s) across 2 QPI links Chipset Intel C612 Front Side Bus Speed 2133MHz System Memory Sizes RDIMM: 32GByte, 16GByte, 8GByte or 4GByte LRDIMM: 64GByte or 32GByte Type Standard ECC Registered DIMMs (RDIMMs) Optional Load-Reduced DIMMs (LRDIMMs) Configuration DDR4-2400MHz, 1866MHz, 1600MHz, 1333MHz Maximum Size 512GBytes using 16 x ECC Registered DIMMs (RDIMMs) 1TByte using 16 x Load-Reduced DIMMs (LRDIMMs) 4x PCI-E 3.0 x16 PCI Express expansion slots 2x PCI-E 3.0 x8 (1 in x16) 1x PCI-E 2.0 x4 (in x8) System BIOS AMI Ethernet ports (standard) 2 x Intel RJ-45 ports Controller Dual Intel i350 network controllers Support 10BASE-T, 100BASE-TX, and 1000BASE-T Ethernet port (management) RJ-45 port for management only Controller Aspeed AST2400 BMC with dedicated IPMI Support 10BASE-T, 100BASE-TX, and 1000BASE-T Solid State Drive (SSD) 500GByte Serial ATA (SATA) 4 x SATA 3 connectors Drive Format 2.5-inch (63.5mm) solid-state drive (SSD) Transfer Rate 6.0GByte / second (theoretical) Number of drives / Capacity 1 standard or 2 optional Graphics Controller Aspeed AST2400 BMC Audio Controller High-Definition (HD) 7.1 with SPDIF-input digital header Serial port COM1 (DB-9) Universal Serial Bus (USB) Version 3.0 Ports 4: 2 x USB 3.0 and 2 x USB 2.0 AC Power Supply One single-phase, auto-ranging, 90-240VAC, 10-5Amps, 50/60Hz; total output power is not to exceed 1,500Watts Operating Environment 0 to 30 Celsius (32 to 86 Fahrenheit) temperature 5% to 80% non-condensing humidity Altitude Maximum Operating 10,000ft (3,050meters) Storage 50,000ft (15,240meters) Dimensions 7.00 H x 19.00 W x 25.50 D (17.78 cm H x 48.26 W x 64.77CM D) Weight 49.00 lbs. (24.50kg) Warranty / Period Parts & labor return to manufacturer / 2 year Ext. Warranty Period Optional 3 rd year Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 2

Memory Configuration DIMM Configurations for CPU1 Only # DIMMs Location Memory Scheme P1-DIMMA1 4 P1-DIMMB1 P1-DIMMC1 P1-DIMMD1 P1-DIMMA1 P1-DIMMB1 Interleaved DIMMs must be identical P1-DIMMC1 type and speed P1-DIMMD1 8 P1-DIMMA2 P1-DIMMB2 P1-DIMMC2 P1-DIMMD2 DIMM Configurations for CPU1 and CPU2 16 P1-DIMMA1 P1-DIMMB1 P1-DIMMC1 P1-DIMMD1 P1-DIMMA2 P1-DIMMB2 P1-DIMMC2 P1-DIMMD2 P2-DIMME1 P2-DIMMF1 P2-DIMMG1 P2-DIMMH1 P2-DIMME2 P2-DIMMF2 P2-DIMMG2 P1-DIMMH2 Interleaved DIMMs must be identical type and speed PCIe Gen 3 Slots When installing a HIC in HE4U, make sure you seat it in one of the PCIe Gen 3 x16 slots, which are numbered CPU1 Slot2, CPU1 Slot 4, CPU2 Slot 6 and CPU2 Slot 8. For double-wide accelerators like NVIDIA Quadro Series or AMD Firepro W Series, use these four slots as well. If you add a single-wide display controller like AMD Firepro W2100 / W4100 or NVIDIA Quadro K4200 for connecting one or more 4K / UHD displays, and the PCIe Gen 3 x16 slots are occupied, use CPU1 Slot 10. HostEngine 4U supports one to four 2.5-inch SATA 3 solid-state drives (SSDs) to boot the operating system (OS). HostEngine 4U also accommodates PCIe flash / SSDs. Install PCIe flash or SSD cards in CPU1 Slot 10 and / or CPU2 Slot 11, if available. See page 4 for details. Access Remove / Replace HostEngine HostEngine can be removed and replaced from the front once you remove power. Power down gracefully using the OS or the front-panel on / off switch. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 3

Wait for the power to shut off. Disconnect power and all other cables from HostEngine. Loosen the two retention screws on the HostEngine front panel. Gently tug the HostEngine handles toward you. Extract the HostEngine while supporting its weight. Slide the replacement HostEngine into the rack mount slide mounts. Slide HostEngine into the cabinet. Replace and tighten the retention screws. Connect power and all other cables to HostEngine. Power up HostEngine. Remove and replace PCIe devices PCIe devices can be removed and replaced from the top once you power down HostEngine and remove the cop cover. See the image below for the PCIe devices to install in each slot. Power down gracefully using the OS and wait for the power to turn off Loosen the two retention screws on the HostEngine front panel. Gently tug the HostEngine handles toward you. Remove the screws holding the top cover and set it aside. Disconnect auxiliary power cables from the PCIe devices such as accelerators, if needed. Remove / replace the PCIe devices and re-connect the drive power and data cables. Replace the top cover and its retaining screws. Slide HostEngine into the cabinet. Replace and tighten the retention screws. Power up HostEngine. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 4

Remove and replace a SATA drive SATA drives are removable from the front panel once you power down HostEngine. Power down gracefully using the OS or the power on/off button on HostEngine front panel and wait for the power LED to turn off Loosen the retention screw on the LaserBlade drive mounting bracket Gently tug the drive mounting bracket handle. Disconnect the drive power and data cables. Remove / replace the drive and re-connect the drive power and data cables. Slide in the drive mounting bracket and tighten the retention screw. Note Power down HostEngine before removing it or its hard disk drive. Connections, Controls and Indicators Connections On the rear panel, HostEngine provides four USB 2.0 ports, two Gbps Ethernet ports, a COM port and an IPMI 2.0 GbE port. The AC power receptacle is also on the rear panel. HostEngine also provides access for Cubix HICs that connect to GPU-Xpander Rackmount 8 or other Xpander enclosures using external PCIe x16 cables, if needed. With these connections, you can mount HostEngine immediately above or below GPU-Xpander Rackmount 8. You can also install PCIe cards inside HostEngine 4U. For example, install 4 x full-length, full-height, double-wide GPUs inside HostEngine 4U. Controls The front panel provides the power on/off button and the reset button. Pressing and releasing the power button during operation will provide a graceful shutdown of the operating system. Pressing and holding the power button for 4 seconds or more forces HostEngine to power off. See the image at the right. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 5

Indicators Indicators (LEDs) for power (steady green), hard drive activity (flashing green), reset (flash green once), management (steady green) and identification (steady blue if enabled) are also on the front panel. Install HostEngine in a Rack Mount Cabinet Cubix ships HostEngine with the slide mounts installed on the enclosure. Within packaging, you will find four brackets that mount within your rack mount cabinet as well as screws, nuts and G-nuts for use in mounting HostEngine. See the image at right. Mount HostEngine close enough to GPU-Xpander Rack Mount 8 so that the standard 2meter cables will reach. Mount GPU-Xpander Rack Mount 8 enclosure immediately above or immediately below HostEngine in the rack mount cabinet. For this procedure, use a Philips #2 screwdriver, a flatblade screwdriver and a 3/8 wrench or socket and drive. 1. Shut down HostEngine normally. 2. Disconnect all data and power cables. 3. Remove the two slide mounts one slide mount from each side of the HostEngine enclosure. To release each slide mount, slide it toward the rear of the enclosure until it stops. Press the catch to release and remove the slide mount as you can see in the image at the right. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 6

4. Mount the HostEngine mounting brackets and slide mounts in your cabinet. Allow vertical space for 2U or 4U as appropriate for your enclosure. 5. Mount the front and rear mounting brackets in the left side of your cabinet. Make sure all four line up so that HostEngine is level within the cabinet. See the image at the right. 6. Mount each of the two sliders into the front and rear mounting brackets (Part # S18500A) and slider assembly with the bolts and G-nuts provided in the packaging. Use the Philips #2 screwdriver and the 3/8 wrench or socket to secure snugly but not tightly each slider to the front and rear mounting brackets. Check to make sure the mounting brackets and slide rails are level from front to rear before tightening the screws and nuts. Align the front of the slider with the front of the cabinet. 7. Repeat the process for the other two front and two rear mounting brackets and slider assembly on the right side of the cabinet. 8. Check to make sure that the slide rails are level, both from front to back and from right to left. Once you re sure the slide rails are level, you re ready to tighten the mounting screws. See the image at the right. 9. Tightly secure the screws holding the sliders to the front and two rear mounting brackets on each side of the cabinet. 10. Extend the slide rails almost all the way out the front of the cabinet. 11. Lift the HostEngine, line it up carefully and slide it into place. Before lifting the HostEngine into place, ask for assistance. Warning Before you lift a HostEngine into place, ask for assistance. 12. Try sliding the HostEngine in and out slightly to make sure it moves freely. 13. Connect the AC power cords into the HostEngine rear receptacle. 14. Connect the PCIe x16 external cables to GPU-Xpander Rack Mount 8. 15. Power up HostEngine. Cubix Corporation 2800 Lockheed Way Carson City, NV 89706-0719 Page 7