Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Similar documents
Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Application Description

Product and functional description

Product and functional description

Product and functional description

Product and Applications Description

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description

Product and functional description

Product and functional description

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Push button UP 287, 4 - fold

584 5WG AB_1 DELTA

Push Button Interface UP 220D31

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

DELTA profil wall switch, single UP 241/2 5WG AB_2

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

DELTA i-system wall switch single UP 221/2 5WG AB_2

Operating and mounting instructions

Operating voltage Maximum

252F 5WG FB_1 DELTA

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Weather station AP 257/51

Weather station GPS AP 257/61 Weather station AP 257/51

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

Product and Function Description

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Product and Application Description

Operating Instructions VEGAMET 381

Operating instructions. Standstill monitor A / / 2011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX BCI/S Boiler/Chiller Interface

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Digital input modules

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Selection and Application Guide compelling FLEXIBLE. LCP3000EZ Lighting Control. Global network of innovation

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

TXM1.8RB. TX-I/O Blinds module

Operating instructions only for authorized, skilled electricians with EIB training

SITOP in the SIMATIC Design

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Extension module for lighting control

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Power supply module, bus connection module

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

Super universal modules

Resistance measuring module

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Module 18plus. Description. 18plus

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RM84 miniature relays

Operating instructions Evaluation system for flow sensors VS / / 2013

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

UNIVERSAL DIMMER DIM02SA/500U

Overview of types. Technical data

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Operating instructions. Switching amplifier DN0210 DN / / 2015

Miniature Circuit Breakers for Railway Applications

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

SIPLUS S7-200 PS 203. Overview

Installation Instructions

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Compact universal controllers

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Operating instructions. Speed monitor D / / 2014

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

TRIO-DIODE/12-24DC/2X10/1X20

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Line Coupler, MDRC LK/S 3.1, GH Q R0001

Immersion Temperature Sensors

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

Thermal-Magnetic Circuit Breaker 2216-S

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Transcription:

Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval. The universal I/O module is a N-system DIN-rail mounted device. Besides the contacting system for the data-rail it provides an EIB connection block for the connection to the bus. The module requires a 24 V direct or alternating current external voltage supply (e.g. 6EP1 332-1SH41 LOGO! power). Two Universal in-/outputs are available, allowing to use each terminal as binary or analog in- or output, thus causing the existence of 4 operating modes for each universal input/output fundamentally different from each other: binary input binary output analog input analog output Example of Operation universal I/O modul N 670 bus coupling unit relay input B input A B A I/O B I/O A 24V L 14 13 L 12 11 10 9 8 + M + M P N load circuit AC 230V L1 N 7 6 5 4 3 2 1 orange dark grey T T electric load e.g. fluorescent lamp sensor sensor relay passive loads supply voltage AC/DC 24V 2 inputs for two-wire operated sensors are available for temperature measuring. Furthermore 2 performance relays with the appropriate switching- and force guidance objects are available. Application Programs 20 CO Uni I/O Unit 2IO 2Rel 2Pt 900501 binary inputs for switching on/off/toggle binary outputs each providing one positive drive analog inputs for voltage range 0 10 V analog outputs for voltage range 0 10 V two sensor inputs available two bistable power relays for operations supporting only switching tasks allows switching on bus voltage failure allows switching on bus voltage recurrence Installation Instructions The device may be used for permanent interior installations in dry locations within distribution boards or small casings with DIN rail EN 60715-TH35-7,5. The device must be mounted and commissioned by an authorised electrician. A safety disconnection of the device must be possible. Especially if the device is connected to different phases. Free DIN rail areas must be covered with covers, order no. 5WG1 192-8AA01. The prevailing safety rules must be heeded. The device must not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Electrical Installation Technology Siemens AG 2003 Update: http://www.siemens.de/gamma 2.6.1.1/1

Technical Specifications Power supply bus voltage: via bus line external module supply 24 V AC/DC ± 10%, max. 100 ma (depending on the load) DC reverse voltage protection available The bus voltage mustn't be used for the 24 V supply of the module. The external 24 V module supply must be equipped with a basic insulation for 250 V. The connection block "N" of the external module supply is connected with the mass connection blocks "M" of the Universal terminals. If a number of modules are fed by alternating current from a single transformer take care that the phases of the connection blocks 1 and 2 are equally connected if in-/outputs or sensors of different modules are galvanically connected. Control elements 1 learning button: for switching between normal operating mode and addressing mode Display elements 1 red LED: for monitoring bus voltage and displaying mode, selected with the learning button In-/ Outputs universal in-/outputs - number: 2 binary respectively analog input - min. input voltage: 0V - max. input voltage: 10 V - input resistance: 25 k Take care that the terminals are polarised correctly. The input voltage range must not be exceeded! binary respectively analog output - for passive loads and relays - min. output voltage 0 V - max. output voltage: 10V - accuracy: ±50mV - resolution approx. 20 mv - permanent output current: max. 10 ma - limited short-circuit strength inputs - number: 2 - temperature range: -25...45 - accuracy: ±0,5 K - resolution: 0,1 K Relay outputs number: 2 outputs (volt-free contacts) rated voltage: AC 230 V, 47...63 Hz rated current: 10 A resistive load switching current at AC 230 V: 0.01...10 A resistive load switching current at DC 24 V: - 10 A resistive load - 4 A inductive load (L/R = 7 ms) Switching power at AC 230 V at incandescent lamp load: max. 1000 W at fluorescent lamp (FL) load: - uncorrected FL, cos 0,5: max. 500 VA - parallel corrected FL, cos 1 (at C tot <= 14 µf): 2 x 58 W or 3 x 36 W or 6 x 18 W - twin-lamp circuit, cos i 1: max. 1000 W - OSRAM ECG for 58 W FL: max. 10 units - OSRAM ECG for 36 W FL : max. 15 units - OSRAM ECG for 18 W FL : max. 20 units If 230 V-loads are connected the terminal blocks 12 and 14 have to be connected to the same phase. Connections load circuit and external power supply (connection block 1 and 2, 11-14), physical: - 0,5... 2,5 mm² single core or flexible conductor, 8 mm ultrasonically compacted - 0,5... 2,5 mm² flexible conductor with terminal pin, Universal in-/output and PT1000-inputs (connection blocks 3 10) - 0,5... 1,5 mm² single core - 0,5... 1,5 mm² flexible conductor with terminal pin, Technical Manual N 670, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2003 Electrical Installation Technology 2.6.1.1/2

load circuit, electrical: - plain flexible conductor, min. 1 mm²: current carrying capacity max. 6 A - all other conductors, min. 1,5 mm²: current carrying capacity max. 10 A - The load circuits must be protected with a 10 A miniature circuit breaker A or B characteristic When looping through the L-conductor (connection blocks 12 and 14), take care that the maximum connection current of 10 A (as governed by the maximum permissible printed conductor load) is not exceeded! Bus line - pressure contacts on data rail - screwless bus connection block Ø 0,6... 0,8 mm single core remove approx. 5mm of isolation Physical specifications housing: plastic N-system DIN-rail mounted device, width 4 SUs (1 SU = 18 mm) weight: approx. 160 g fire load: approx. 3100 kj installation: rapid mounting on DIN rail EN 60715-TH35-7,5 Electrical safety Degree of pollution (according to IEC 60664-1): 2 protection (according to EN 60529): IP 20 overvoltage class (according to IEC 60664-1): III bus: safety extra low voltage SELV DC 24 V the device complies with EN 50090-2-2 and EN 60669-2-1 Reliability rate of failure: 961 fit at 40 C Electromagnetic compatibility complies with EN 50081-1, EN 50082-2 and EN 50090-2-2 Environmental specifications climatic conditions: EN 50090-2-2 ambient temperature operating: - 5... + 45 C ambient temperature non-op.: - 25... + 70 C relative humidity (non-condensing): 5 % to 93 % Certification EIB certificate CE norm complies with the EMC regulations (residential and functional buildings), and low voltage regulations Location and Function of the Display and Operator Elements A1 A2 A3 Figure 1: Location of the display and operator elements A1 bus connection block screwless A2 LED for indicating normal operating mode (LED off) and addressing mode (LED on); upon receiving the physical address the device automatically returns to normal operating mode A3 Learning button for switching between normal operating mode and addressing mode for receiving the physical address A4 Type plate A5 Screwless plug-in terminals for connecting load circuits A6 Test sockets for observing the voltage Mounting and Wiring General description The N-system DIN-rail device can be installed to N-system distribution boards, surface or flush mounted, or to any available DIN rail EN 60715-TH35-7,5. The connection to the bus line is established by bus connection blocks or by clicking the device onto the DIN-rail (with a data rail installed). Take care that the type plates of all devices on a DIN-rail can be read in the same direction, guaranteeing the devices are polarised correctly. If the connection is established via bus connection blocks (data-rail not installed) the contacting system towards the data-rail has to be covered by removing the guide top e.g. with a screw-driver and afterwards A4 A5 A6 Electrical Installation Technology Siemens AG 2003 Update: http://www.siemens.de/gamma 2.6.1.1/3

snapping on the insulation top to ensure a sufficient insulation towards the DIN-rail. For mounting the I/O modules ( and all other DIN rail devices) the usually employed adapter is not necessary. The bus voltage is forwarded from the bus connection block to the data rail. Mounting DIN-rail devices (Figure 2) - Slide the device (B1) onto the DIN-rail (B2) and - swivel back the device until the slide clicks into place audibly. Dismounting DIN-rail devices (Figure 2) - Remove all connected wires, - press down the slide (C3) with a screw-driver and - swivel the device (C1) from the DIN-rail (C2). B1 B2 C1 C2 Figure 2: Mounting and dismounting a DIN-rail device Removing the guide top (figure 3) - The guide top (D3) encloses the contacting system (D2) on the back side of the universal module N 670 (D1) - Insert the screw-driver between the DIN-rail mounted device (D1) and the guide top (D3) and pull out the guide top. C3 Slipping off bus connection blocks (Figure 4) - The bus connection block is situated on the top of the Universal I/O module N 670(E2). - The bus connection block () consists of two components (.1 and.2) with four terminal contacts each. Take care not to damage the two test sockets (.3) by accidentally connecting them to the bus cable or with the screw-driver (e.g. when attempting to unplug the bus connection block). - Carefully put the screw-driver to the wire-inserting slit of the bus connection block's grey component (.1) and pull the bus connection block from the Universal I/O module (E2). Note Don't try to remove the bus connection block from the bottom side! There is a risk of shorting-out the device! Slipping on bus connection blocks (Figure 4) - Slip the bus connection block onto the guide slot and - press the bus connection block () down to the stop. Connecting bus cables (Figure 4) - The bus connection block () can be used with single core conductors Ø 0,6... 0,8 mm. - Remove approx. 5 mm of insulation from the conductor (.4) and plug it into the bus connection block () (red = +, black = -). Disconnecting bus cables (Figure 4) Unplug the bus connection block () and remove the bus cable conductor (.4) while simultaneously wiggling it. Snapping on the insulation top (figure 3) - Stick the insulation top (D4) onto the contacting system and snap it on by pressing. D3 D1 D2 D2 D4 D1 E2.3.1.2.4 5 mm.4 Figure 4: Connecting and disconnecting bus cables Figure 3: covering the contacting system Technical Manual N 670, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2003 Electrical Installation Technology 2.6.1.1/4

Connecting control and load circuits (Figure 5) - The load circuits are connected via screwless plug-in terminals (F1). - Remove approx. 9 to 10 mm of insulation from the wire (F1.1) and plug it into the terminal (F1). Conductor cross sections: load circuit and external power supply (connection block 1 and 2, 11-14), physical: - 0,5... 2,5 mm² single core or flexible conductor, 8 mm ultrasonically compacted - 0,5... 2,5 mm² flexible conductor with terminal pin, Universal in- / output and PT1000-inputs (connection blocks 3 10) - 0,5... 1,5 mm² single core - 0,5... 1,5 mm² flexible conductor with terminal pin, load circuit, electrical: - plain flexible conductor, min. 1 mm²: current carrying capacity max. 6 A - all other conductors, min. 1,5 mm²: current carrying capacity max. 10 A Disconnect control and load circuits (Figure 5) - Press the terminal lock (F1.2) with a screw-driver and - remove the wire (F1.1) from the terminal (F1). Dimension Diagram Dimensions in mm b b = 4 SU 90 1 Spacer unit (SU) = 18 mm General Notes 44 55 45 Any faulty devices should be returned to the local Siemens office. If you have further questions about the product, please contact our Technical Support: +49 (0) 180 50 50-222 +49 (0) 180 50 50-223 adsupport@siemens.com F1.1 F1.2 F1.1 F1 9... 10 mm F1 Figure 5: Connecting and disconnecting control and load circuits Electrical Installation Technology Siemens AG 2003 Update: http://www.siemens.de/gamma 2.6.1.1/5