Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

Similar documents
Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert PDX from 15 to 120 kw

Liebert PCW. Cool the Cloud

Liebert PDX from 15 to 120 kw

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert. EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Liebert. DCL up to 35 kw. Modular Rack Cooling

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Liebert. DCL up to 35 kw. Modular Rack Cooling

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

SUPERSAVER. Energy Efficiency Optimization Software for Freecooling Systems

Liebert HPM from 4 kw to 100 kw

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

VERTIV SERVICE CAPABILITY

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Precision Cooling. Precision Cooling Advantages

CRITICAL INFRASTRUCTURE ASSESSMENTS

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert DCW CATALOGUE

Liebert HPC Freecooling Chiller

Liebert HPC. Data Center Freecooling Chiller with 100% Compressor Back Up

VERTIV LIFE SERVICES. Remote Diagnostic and Preventive Monitoring

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Total Modular Data Centre Solutions

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Data Center Optimized Controls

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

Close-coupled cooling

MSYS 4480 AC Systems Winter 2015

Liebert. PDX and PCW Compact Perimeter Cooling Solutions

We Invented Precision Cooling

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert : The Right Cooling For IT Environments

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Thermal management. Thermal management

Liebert exm TM. 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Ecotel Free Cool 5-15kW

Liebert NXC from 10 to 200 kva

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Building Management Solutions. for Data Centers and Mission Critical Facilities

Emerson Network Power Technology and Solutions for a World in Action

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Industry leading low energy evaporative fresh air cooling.

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Five Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

2017 EMEA Data Centre Cooling Solution Product Leadership Award

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Switch to Perfection

SmoothAir Modular Precision Cooling

Precision Cooling Mission Critical Air Handling Units

IT Air Conditioning Units

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Rack cooling solutions for high density racks management, from 10 to 75 kw

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

GP SERIES Packaged Chillers

18 th National Award for Excellence in Energy Management. July 27, 2017

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER

Welcome Association of Energy Engineers to the Microsoft Technology Center

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

Transcription:

Liebert PCW from 25 to 220 kw Chilled Water Units Optimizing Data Center Efficiency

LIEBERT PCW from 25 to 220 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communication networks, and commercial and industrial environments. We support today's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented by our global service network. Bringing together global reach and local knowledge, and our decades-long heritage including brands like Chloride, Liebert and NetSure, our team of experts is ready to take on your most complex challenges, creating solutions that keep your systems running and your business moving. Together, we re building the future of a world where critical technologies always work. YOUR VISION, OUR PASSION. VertivCo.com Liebert PCW: For Improved Energy Efficiency, Performance and Reduced Operating Costs Liebert PCW is the ideal unit for those data centers using chilled water as cooling fluid and that typically range from 200 kw up to 4-6 MW. The overall solution encompasses the cooling unit as well as direct freecooling, freecooling chillers and/or adiabatic freecooling chillers delivering top-tier system efficiency to ensure data center reliability and availability. Liebert PCW, coupled with our Liebert AFC adiabatic freecooling chillers, optimizes system control even further and guarantees ultimate system efficiency all year round as a result of its optimized floating water set point. All components and control strategies have been enhanced to provide an extremely efficient solution for both conventional computer rooms and for infrastructures facing the challenges of modern IT applications. 2

Liebert PCW designed for the lowest air resistance 3

LIEBERT PCW from 25 to 220 kw Liebert PCW Sets New Standards in Energy Efficiency Amongst Chilled Water Data Center Applications High Efficiency As a result of the optimized aerodynamic design (minimum internal pressure drops), the new Liebert EC Fan 2.0 and the new automotive high efficiency filters, Liebert PCW can perfectly match the server heat load with minimum power consumption. Liebert PCW also minimizes the running costs of the cooling system. Cooling and Power Energy Meters Measurement is key to control. The accurate metering provided by Liebert PCW gives users the advantage of controlling cooling capacity, power input and all the parameters that simplify the management of the data center, thus ensuring continued infrastructure cooling even in the unlikely event of a unit failure. Adiabatic Freecooling Chillers & Supersaver Adiabatic freecooling chillers take advantage of low external temperatures to cool down water. The Supersaver functioning mode maximizes freecooling operation. Whenever possible the system will automatically raise water temperatures as thermal loads fall, aligning cooling capacity with demand, thus increasing system efficiency and freecooling operation. Liebert EC Fan 2.0 The new generation of fans are the core of the Liebert PCW, dramatically reducing the noise level and increasing unit efficiency. Ultrasonic Humidifier Liebert PCW cutting-edge technology allows each of its components to save energy while delivering the cooling performance that data centers need. The infrared and the electrode boiler humidifier are two efficient options made available. Eurovent Certified Eurovent certification guarantees that Liebert PCW undergoes independent testing, thus delivering rating accuracy and enhancing the unit's reliability. Check ongoing validity of certificate: www.eurovent-certification.com Aeraulic Design Liebert PCW- patent granted, presents a unique inner aerodynamic architecture - from the coil angle to the electrical panel - achieving an outstanding competitive advantage and state-of-the-art efficiency. Vertv ICOM Control Smart mode is a control algorithm developed for SmartAisle applications (cold aisle containment) meeting the cooling and airflow needs of the servers without wasting a single Watt on unnecessary cooling or air movement. Dual Power Supply To deliver maximum redundancy thus guaranteeing full flexibility. Fast Start Ramp A software solution ensuring unit restoration 10 seconds after a power outage. 4

Liebert PCW: Simplifies Installation for Real Operational Efficiency Adjustable Legs Liebert PCW legs can be easily adjusted to suit the installation positioning requirements, enabling modification in relation to the height of the on-site raised floor level. Any future maintenance action will be timely and simple. User Friendly Electrical Connections Kit Liebert PCW extended solution offers power cables with fast coupling to allow easy connection between the fan and coil modules, reducing installation time. Easy Handling And Easy Alignment Fast Electrical Connection Kit Water Connections on Demand Liebert PCW presents three options for water connection: from the bottom, from the top and from the left of the unit, for a flexible on-site configuration. Floor Tile Support & Maintenance Kit Liebert PCW has specific kits to sustain floor tiles in proximity to the unit. Furthermore, to simplify access to the fans during installation and replacement, the Liebert PCW maintenance kit facilitates servicing, reducing repair time and possible downtime. The kit has also been specifically designed and tested to provide support for the fans during replacement. Adjustable Legs On-Demand Water Connection 5

LIEBERT PCW from 25 to 220 kw Vertiv ICOM Control to Ensure Top Reliability Under Any Conditions SUPERSAVER: Continuous Dynamic Optimization of Chilled Water Systems The floor-mount units and adiabatic freecooling chillers communicate with each other through the Supersaver functioning mode which enables complete coordination between the two systems, thus delivering top-tier performances. Unit to Unit Communication The ICOM TM Control directly connects with the facility network (Ethernet) and enables communication between multiple Liebert PCW units for synchronized operation, guaranteeing higher reliability and precision cooling room control. Flexibility in Adapting to Different Sites Liebert PCW offers different control strategies to best suit legacy design applications as well as those with separation between the cold and hot aisle. Solutions Optimizing the Applications Liebert PCW can offer solutions to reduce the starting time to ensure the best cooling continuity. 6

Liebert PCW units with graphic display may be centrally monitored and controlled with the optional wall mounted display. The display allows access to the unit via the Network, making coordination between the Liebert PCW units within the same room possible as a result of the integrated Ethernet connection. The self monitoring of redundant units alternates standby positions and gives priority to possible hot spots. The high-level supervision of multiple units allows them to work together as a single system to optimize room temperature and humidity. This is of particular importance when the EC Fan is considered. EC fan power consumption is exponential. Having five units running at 80% instead of four at 100%, means that the energy used by the additional unit is cut by 50% and the total energy used by the entire group by 36%. ICOM manages the reduction of fan speed whenever operation at full capacity is not required. 7

LIEBERT PCW from 25 to 220 kw Liebert PCW: Remote Diagnostic and Preventive Monitoring Services Vertiv LIFE Services: Remote Diagnostic and Preventive Monitoring It is essential that your critical cooling system is maintained in an optimum state of readiness at all times. Our services monitor and prevent possible alarm conditions. Allows effective proactive maintenance and fast incident response, giving customers complete security and peace of mind. Service center engineers are permanently on hand to provide immediate fault analysis and appropriate corrective action. The customer will be informed about the status of the installation through detailed reporting providing valuable information on unit functioning and trends over any selected period of time. Basic Web Access SiteScan Web Control, Data Capture, Energy Management and Planning Advanced Access With Intellislot Card Monitoring and Alarm Notification through Vertiv Nform 8

Basic Web Access Basic operational information can be made available through the monitoring feature offered by the ICOM Control over Ethernet. A web browser is the only requirement needed for the unit to communicate directly with the local or remote web interface. Monitoring and Control Through Existing Network Via your Web Browser Liebert IntelliSlot Unity-DP Card The Liebert IntelliSlot Unity Card (IS-UNITY-DP) provides ground fault isolated RS-485 Modbus, BACnet IP and Modbus IP network connectivity to Building Management Systems for unit monitoring and management. Also, it provides ground fault isolated 10/100 base-t Ethernet connectivity for unit monitoring and management. The supported management interfaces include: SNMP for Network Management Systems, HTTP for Web page viewing, SMTP for e-mail and SMS for mobile messaging. The card supports IP and 485 protocols simultaneously. Monitoring Integration with Existing Building Management System If required, Liebert PCW may be integrated with an existing Building Management System, while the IntelliSlot Unity Card provide Modbus RTU and Modbus TCP compatibility. SCADA support is completed through the Bacnet over IP card. Nform Software Centralized Management As business grows, critical equipment infrastructure expands, thus the need for centralized management of any equipment is key to business success. Connecting to equipment in the distributed critical space is only part of the monitoring challenge. Nform leverages the network connectivity capabilities of Liebert PCW to provide centralized monitoring of the distributed equipment. Utilizing the SNMP and Web technologies integrated in each IntelliSlot communication card, Nform centrally manages alarm notifications and provides an intuitive interface to access critical status information. Nform TM allows critical system information to be readily available to support personnel wherever they are, increasing responsiveness to alarm-event conditions, thus allowing IT organizations to maximize their system availability. SITESCAN WEB CONTROL, DATA CAPTURE, ENERGY MANAGEMENT AND PLANNING For customers who require extensive management of critical system equipment spanning multiple locations in an ever-moving global enterprise, SiteScan Web will centrally manage critical equipment and give the power to move beyond the event responsive service paradigm. SiteScan Web does it all Real-Time Monitoring and Control Event Management and Reporting Data Analysis and Trending Building Management Integration SiteScan Web is a comprehensive critical system management solution dedicated to ensuring reliability through graphics, event management and data export. The standard Web interface allows users easy access from anywhere, anytime. 9

LIEBERT PCW from 25 to 220 kw Liebert PCW: Chilled Water Systems Given a specific amount of heat load, there can be different ways to approach a system design. Ideally, it is best to start from the server needs in terms of airflow and temperature, while considering the separation of the cold and hot aisle and only subsequently start to design the most appropriate Liebert PCW unit. The results will be that the chilled water loop nominal water temperatures can be increased thus increasing freecooling operation. Together with with our adiabatic freecooling chillers and the dynamic optimization of the chilled water loop, chilled water system annual efficiency is maximized even further and new efficiency levels can be reached. SMART Equipment description Room Set Point Water/Glycol 18 C - 24 C Where it is most commonly applied Adiabatic freecooling chillers, room cooling units, aisle containment and dynamic optimization of chilled water system. 22 C 50% in front of the servers A) All climates B) Data center cooling separated from air conditioning ppue 1.08 1.0 2.6 Application constraints Benefits Existing Data Center - Mandatory hot and cold aisle configuration - Chillers must be dedicated due to high working temperatures - SmartAisle : Top efficiency as a result of dedicated solutions taking advantage of higher working temperatures (maximized freecooling) - Increased system efficiency as a result of Supersaver functioning mode (intelligent communication between Liebert AFC and Liebert PCW) Simple retrofit in the case of hot and cold aisle separation ECO WATER Equipment description Room Set Point 24 C 50% Water/Glycol 10 C - 15 C Where it is most commonly applied Chiller with freecooling and room cooling units A) Data center cooling separated from air conditioning B) Cold and medium climates to take advantage of Freecooling benefits ppue 1.20 1.0 2.6 Application constraints Benefits Existing Data Center - Mandatory use of glycol solutions to avoid chiller freezing Liebert PCW provides the highest net sensible capacity for under any working condition. Increased system efficiency as a result of the Supersaver Evolution functioning mode (intelligent communication between Liebert HPC and Liebert PCW) Simple retrofit 10

ECO AIR Equipment description Room Set Point Water/Glycol 10 C - 15 C Where it is most commonly applied Application constraints Benefits Chiller with freecooling, room cooling units and air channels 24 C 50% (once direct freecooling is in operation, supply set point 22 C 50%) A) Cold and medium climates to exploit freecooling benefits - No indication when the cold and warm seasons are too humid or too dry, thus reducing possibility of increased use of direct freecooling - Being in contact with both external and internal conditions, external events (fire, smoke, pollution) can compromise internal operation of data center Economizer function allows perfect control of temperature and humidity, optimizing the energy benefit of this type of system Existing Data Center Extremely complex retrofit due to air channels ppue 1.23 1.0 2.6 LEGACY Equipment description Room Set Point 22 C 50% Water/Glycol 7 C - 12 C Where it is most commonly applied Chiller without freecooling and room cooling units A) Same chilled water system is used both for cooling the data center as well as for comfort cooling B) Hot climate where the external temperatures rarely goes below 5 C ppue 1.30 1.0 2.6 Application constraints Benefits Existing Data Center - Reduced efficiency due to low water temperatures (no freecooling) - Reduced efficiency due to unnecessary dehumidification (SHR<1) Liebert PCW provides the highest net sensible capacity under any working conditions. Simple retrofit 11

LIEBERT PCW from 25 to 220 kw Enhanced Freecooling Mode with Liebert PCW High Chilled Water Delta T The Liebert PCW with high chilled water delta T has been designed to maximize freecooling operation, as well as granting a proper supply air temperature to the servers. The design considers a water regime of 20 C / 32 C, with airflow of 35 C on the return side and a supply air temperature between 24 C and 25 C. This system leverages on freecooling almost all year round with a solution granting the complete separation of the external and internal ambient, thus significantly reducing the overall system power consumption. Additionally, the increased delta T reduces the water flows, thus saving energy also on the pumping system and allowing for the sizing of any part related to the water flow. This system can be optimized even further when integrated with the Liebert AFC, our adiabatic freecooling chillers and optimized for such high water regimes. This new operating point represents a new challenge for the internal air conditioning units: water speed is greatly reduced and the heat exchange factor differs significantly with respect to past applications. Liebert PCW high chilled water delta T has been developed to provide an efficient answer to these new challenges: its ad hoc coil design best suits water and glycol operations and its top door grill exploits the entire coil surface, thus optimizing the overall heat exchange. 12

Liebert PCW with High Chilled Water Delta T 13

LIEBERT PCW from 25 to 220 kw Liebert PCW Configurations Extended Down Unit Liebert PCW Extended Down with fan modules installed in the raised floor, delivers optimum energy efficiency (70% saving compared to standard market solutions with EC Fan). The system is shipped in two parts, fans module and coil module. This enables a shorter lead time on the fans module and optimizes installation time. Adjustable legs are provided in order to tailor the installation to different raised floor heights. 25 kw-220 kw Extended Up Unit (Downflow) Liebert PCW Extended Up delivers up to 50% in energy savings compared to a traditional chilled water unit, even if fans are installed above the raised floor. Moreover, in the event of a demand for increasing density, Liebert PCW responds with a higher capacity (up to 20% more) in the same time frame, without requiring the purchase of an additional unit. 25 kw-220 kw Downflow Unit This is the most common configuration on the market, with a unique level of energy efficiency when compared to the standard market solutions with EC Fan. Liebert PCW Downflow is 2 m high, with coil and fan sections and it achieves energy savings of up to 40%. 25 kw-220 kw 14

Upflow Unit Upflow units are the ideal solution for applications with air distribution from the top of the unit, even with no ducting system. The presence of a Liebert EC Fan 2.0 means that Liebert PCW can deliver the highest External Static Pressure (ESP) whilst limiting power input. 25 kw-150 kw Extended Up Unit (frontal air delivery) In the event that the UPS room or the technical room are the only available locations for installing to the floor-mount unit, the frontal discharge configuration is the most suitable, taking the air at a higher temperature from the top of the unit, and delivering cooled air through the front. 25 kw-220 kw Extended Up Unit (back air delivery) When the site design excludes the presence of water connections inside the data center, the Liebert PCW with back air discharge is the ideal solution for managing these conditions, as the cooling unit is located outside the room, delivering the cold air through the rear of the fan module using the raised floor. 25 kw-220 kw 15

LIEBERT PCW from 25 to 220 kw Liebert PCW - Standard Height UNIT PH025 PH030 PH035 PH040 PH045 PH060 PH070 PH080 PH095 PH100 PH110 PH145 PH170 NET Sensible Capacity Single Circuit Unit [kw] 27.6 30.4 34.7 44.7 49.7 68.8 80.2 86.5 94.2 105.8 121.4 145.8 172.9 NET SENSIBLE Capacity Double Circuit Unit [kw]* - - - 30.1-50.3-60.3 - - 80.5 96.5 115.0 POWER INPUT [kw] 0.92 1.01 1.16 1.39 1.26 2.29 2.63 2.75 3.54 3.42 3.87 5.13 6.75 AIRFLOW RANGE [m 3 /h] 2500-10500 2500-10500 3400-13200 3400-12800 3900-11500 5700-24000 6700-25800 6700-25300 9400-37300 9400-36400 9400-34700 9400-37400 SPARE CAPACITY [%] 35% 35% 20% 20% 20% 25% 20% 20% 20% 25% 25% 15% 15% UNIT DIMENSIONS Width [mm] 844 844 1200 1200 1750 1750 2050 2050 2550 2550 2550 2950 3350 Depth [mm] 890 890 890 890 890 890 890 890 890 890 890 890 890 Height [mm] 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970 UNIT CONFIGURATIONS Down Flow UP - Fans Over the Raised Floor Up Flow Frontal Downflow Down - Fans in Raised Floor 11000-45800 OPERATING MODES Legacy 24 C 40-45% RH; 7 C - 12 C ECO 27 C 35-40% RH; 10 C - 15 C SMART 37 C 30-35% RH; 20 C - 25 C *with one circuit running 16

Liebert PCW - Extended Height UNIT PH046 PH066 PH081 PH091 PH111 PH136 PH161 PH201 NET SENSIBLE Capacity Single Circuit Unit [kw] 44.8 74.5 84.2 109.4 116.4 145.7 164.5 204.0 NET SENSIBLE Capacity Double Circuit Unit [kw]* 37.7 63.3-78.4-105.8 117.2 142.7 POWER INPUT [kw] 1.41 2.05 2.33 3.09 3.48 4.05 4.47 5.99 AIRFLOW RANGE [m 3 /h] 3800-14400 7100-27500 7600-28700 7600-28000 10800-41600 10800-40400 10800-41700 SPARE CAPACITY [%] 15% 25% 20% 15% 20% 20% 20% 20% UNIT DIMENSIONS Width [mm] 1200 1750 2050 2050 2550 2550 2950 3350 Depth [mm] 890 890 890 890 890 890 890 890 Height [mm] UNIT CONFIGURATIONS Down Flow UP - Fans Over the Raised Floor Up Flow Frontal Back Downflow Down - Fans in Raised Floor 1970 +600 1970 +600 1970 +600 1970 +600 1970 +600 OPERATING MODES Legacy 24 C 40-45% RH; 7 C - 12 C ECO 27 C 35-40% RH; 10 C - 15 C SMART 37 C 30-35% RH; 20 C - 25 C *with one circuit running 1970 +600 1970 +600 13100-52700 1970 +600 Liebert PCW: For High Chilled Water Delta T - Extended Height UNIT PH51W PH50W PH60W PH70W NET SENSIBLE Capacity Single Circuit Unit [kw] 113.0 135.3 152.1 173.1 NET SENSIBLE Capacity Double Circuit Unit [kw]* - 93.9 106.8 120.8 POWER INPUT [kw] 5.53 5.59 6.19 7.42 AIRFLOW RANGE [m 3 /h] 15000-47500 15000-47500 15000-50000 19000-60200 SPARE CAPACITY [%] 25% 20% 15% 20% UNIT DIMENSIONS Width [mm] 2550 2550 2950 3200 Depth [mm] 1050 1050 1050 1050 Height [mm] 2350+600 2350+600 2350+600 2350+600 UNIT CONFIGURATIONS Downflow Down - Fans in Raised Floor OPERATING MODES Enhanced Freecooling Mode 35 C 30% RH; 20 C - 32 C *with one circuit running 17

LIEBERT PCW from 25 to 220 kw Thermal Management Data Center Infrastructure for Small and Large Applications Liebert HPC Wide range of high efficiency Freecooling Chillers from 40 kw to 1600 kw Designed specifically for data center applications and to work with SmartAisle Premium energy efficiency version Unique control capabilities with the ICOM Control Liebert PDX - Liebert PCW Available from 5-220 kw Premium energy efficiency Eurovent certified performance Unique control capabilities with the ICOM Control Liebert EconoPhase available for the direct expansion system Trellis Platform Liebert EFC Indirect evaporative freecooling unit leveraging on data center know-how. Available from 100 to 350 kw Unique control capabilities optimizing water and energy costs Substantial reductions and savings in terms of electrical infrastructure Trellis platform is a real-time infrastructure optimization platform that enables the unified management of data centre IT and facilities infrastructure. The Trellis platform software can manage capacity, track inventory, plan changes, visualize configurations, analyze and calculate energy usage, and optimize cooling and power equipment. The Trellis platform monitors the data center, providing a thorough understanding of system dependencies to help IT and facilities organizations keep the data center running at peak performance. This unified and complete solution, delivers the power to see the real situation in your data center, make the right decision and take action with confidence. 18

SERVICE Liebert AFC The Adiabatic Freecooling Chiller available from 500-1450 kw Integrated adiabatic pad system High freecooling capacity 100% compressor back up Available both in multi-scroll and screw versions SmartAisle Aisle containment Provides highest energy efficiency Works with any Liebert Thermal Management unit Vertiv supports entire critical infrastructures with the largest global service organization and an extensive service offering, enhancing network availability and ensuring total peace of mind 24/7. Our approach to servicing critical infrastructure covers all aspects of availability and performance: from single power and thermal management equipment to entire mission-critical systems. The most comprehensive insurance for business protection can be obtained with a service program from Emerson Network Power which includes access to LIFE. VERTIV LIFE SERVICES Liebert CRV Row-based high efficiency cooling units available from 10-60 kw in DX and CW versions Full airflow and cooling capacity modulation to match server load and to save energy Best footprint capacity with the highest efficiency Six different control modes to ensure greater flexibility Vertiv LIFE Services provides remote diagnostics and preventive monitoring service for UPS and thermal management equipment. Vertiv LIFE Services delivers increased uptime and operational efficiency by enabling continuous monitoring of your equipment, expert data analysis and field engineering expertise. Through the data transferred from your equipment via Vertiv LIFE Services, our remote service experts gain the real-time insight and information needed to quickly identify, diagnose, and resolve any irregularities that may arise in operation, ultimately taking responsibility for your critical assets 24/7. Liebert DCL Closed loop rack cooling Two different architectures: - Closed Loop - Hybrid Loop Multiple combinations for up to 4 server racks Dual CW coil version for redundancy 19

VertivCo.com Vertiv, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827 2017 Vertiv Co. All rights reserved. Liebert PCW, Liebert HPC, Liebert AFC, Liebert EFC, Liebert PDX, Liebert EconoPhase, Liebert CRV, Liebert DCL, Liebert EC Fan 2.0, Vertiv Trellis, Vertiv ICOM, Vertiv SmartAisle, Vertiv Intellislot, Vertiv Nform, Vertiv SiteScan and Vertiv LIFE Services are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. MKA4L0UKPCW - Rev.6-06/2017