/ way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated rectifier (40... 60 Hz) These solenoid valves are applicable in Ex protection class ATEX (categories II GD and II 3 GD) and other international approvals Approval depends on magnetic system, see pages to 5! Technical features Medium: For aggressive, gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operation: Direct solenoid operated poppet valves Operating pressure: 0... 50 bar Orifice:... 6 mm Port size: G /8, G /4, /4 NPT Mounting position: Optional, preferably with solenoid on top Ambient temperature: -5... +80 C (NBR) Depending on solenoid system Fluid temperature: -0...+0 C (FPM)- Water +95 C -40... +40 C (EPDM) -50... +80 C (PTFE) -0...+80 C (FFPM) Depending on seal materials Air supply must be dry enough to avoid ice formation at temperatures below + C. Materials: Housing: stainless steel.4404 (36 L) Seals: FPM, other see option selector Inner parts: stainless steel Technical data Switching function: Normally closed Symbol Port size Orifice (mm) Operating pressure (bar) min. max. kv factor (m 3 /h) *3) Weight without Solenoid (kg) No. Solenoid group *) G/8 0 50 0, 0,5 3D 9500 G/8 0 0 0, 0,5 3B 9500 G/4 4 0 0,34 0, 6D 9540 /4 NPT 4 0 0,34 0, 6D 95440 G/4 4 0 5 0,34 0, 6C 9540 /4 NPT 4 0 5 0,34 0, 6C 95440 G/4 6 0 5 0,5 0, 6D 9560 /4 NPT 6 0 5 0,5 0, 6D 95460 G/4 6 0 3 0,5 0, 6C 9560 /4 NPT 6 0 3 0,5 0, 6C 95460 *) When ordering please indicate solenoid, voltage and current type (frequency). *) Technical data and ordering information see following pages. *3) Cv (US) ~ kv x, *) Option selector 95X X... Orifice 4 4 6 6 Material seat seal EPDM FPM PTFE 3 FFPM 4 Frequency (Hz) At d.c. 00 At a.c. (40... 60 Hz) 50 Voltage 4 V d.c. 04 30 V a.c. 30 Solenoid operators See table 4/4 006-538f without notice, the specifications given in this document. 04 Norgren GmbH N/en 5.4.345.0
Solenoids group 3B, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) IP-Protection class (to EN 6059) (ATEX-Category) Temperature Ambient/Fluid 8,0 33-5... +60 9, 40-5... +60 ( C) Electrical connection DIN EN 7530-803, DIN EN 7530-803, Weight Circuit diagram (kg) Nr. Nr. 0,5 046 0,6 7 306 8,0 33 II3G 9, 40 II3G 6,9 89 IIG IID 8,7 34 IIG IID Ex td A T 0 C Ex td A T 0 C Ex mb IIC T4 Gb Ex mb IIIC T0 C Db IP 66 Ex mb IIC T4 Gb Ex mb IIIC T0 C Db IP 66-0... +60 Special connector DIN EN 7530-803, 0,6 36-0... +60 Special connector 0,6 6 38 DIN EN 7530-803, -0... +60 Cable 3 m 0,4 5 4 09-0... +60 Cable 3 m 0,4 5 7 093 3,9 6 IIG IID Ex tb IIIC T30 C Db M0 x,5 *6) 0,5 6 4 40 5,3 3 IIG IID Ex tb IIIC T30 C Db M0 x,5 *6) 0,5 6 7 4 3,9 6 IIG IID Ex tb IIIC T30 C Db /-4 NPT *6) 0,8 7 0 460 5,3 3 IIG IID Ex tb IIIC T30 C Db /-4 NPT *6) 0,8 7 46 3,9 6 IIG IID Ex tb IIIC T30 C Db M0 x,5 *6) 0,8 7 0 46 5,3 3 IIG IID Ex tb IIIC T30 C Db M0 x,5 *6) 0,8 7 463 5,5 8 XP/DIP, Div. & T3 (60 C) 5,9 6 XP/DIP, Div. & T3 (60 C) Datasheet ATEX IECEx FM 09x KEMA 0 ATEX 347 X N/en 7..505 3x, 38x EC-Declaration of Conformity N/en 7..570 37x, 38x CSA-LR 576-6 N/en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585-0... +60 Flying leads -0... +60 Flying leads 0,5 8 37 0,5 8 5 373 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *6) /cable gland not supplied, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. N/en 5.4.345.0 without notice, the specifications given in this document. 04 Norgren GmbH 006-538f 4/4
Solenoids group 3D, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) 6,9 703-5... +60 9,5 75-5... +60,4 475 IIG IID 5, 66 IIG IID,4 475 IIG IID 5, 66 IIG IID,4 475 IIG IID 5, 66 IIG IID IP-Protection class (to EN 6059) (ATEX-Category) Ex tb IIIC T30 C Db Ex tb IIIC T30 C Db Ex tb IIIC T30 C Db Ex tb IIIC T30 C Db Ex tb IIIC T30 C Db Ex tb IIIC T30 C Db 3,6 567 XP/DIP, Div. & T3 (60 C) 5,7 68 XP/DIP, Div. & T3 (60 C) Temperature Ambient/Fluid -0... +60 Flying leads -0... +60 Flying leads DIN EN 7530-803, 0,7 3 0700 0,3 4 6 3703 DIN EN 7530-803, M0 x,5 *6) 0,5 6 4 0 M0 x,5 *6) 0,5 6 7 / x 4 NPT *6) 0,8 7 0 4630 / x 4 NPT *6) 0,8 7 463 / x 4 NPT *6) 0,8 7 0 463 M0 x,5 *6) 0,8 7 4633 0,5 8 376 0,5 8 5 377 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *6) /cable gland not supplied, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. ( C) Electrical connection Weight (kg) Nr. Circuit diagram Nr. Datasheet ATEX IECEx FM 3x, 38x EC-Declaration of Conformity N/en 7..570 37x, 38x CSA-LR 576-6 N/en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585 4/4 006-538f N/en 5.4.345.03 without notice, the specifications given in this document. 04 Norgren GmbH
Solenoids group 6C, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) IP-Protection class (to EN 6059) (ATEX-Category) Temperature Ambient/Fluid 6,8 84-5...+60 DIN EN 7530-803, ( C) Electrical connection Weight Circuit diagram (kg) No. No. 0,33 087 0,6 46-5...+60 DIN EN 7530-803, 0,34 3 6 3805 0,6 46 II3G Ex td A T 0 C T4: -0... +60 Special connector DIN EN 7530-803, - 4 6 388 8,9 369 IIG IID Ex tb IIIC T30 C Db -40... +65 T4-40... +55 T5-40... +65 M0 x,5 *6) 0,500 6 4 470 0,0 IIG IID Ex tb IIIC T30 C Db -40... +65 T4-40... +55 T5-40... +65 M0 x,5 *6) 0,500 6 7 47 8,9 369 IIG IID Ex tb IIIC T30 C Db -40... +70 T4-40... +40 T6-40... +70 / - 4 NPT *6) 0,800 7 0 4670 0,0 IIG IID Ex tb IIIC T30 C Db -40... +70 T4-40... +40 T6-40... +70 / - 4 NPT *6) 0,800 7 467 8,9 369 IIG IID Ex tb IIIC T30 C Db -40... +70 T4-40... +40 T6-40... +70 M0 x,5 *6) 0,800 7 0 467 0,0 IIG IID Ex tb IIIC T30 C Db -40... +70 T4-40... +40 T6-40... +70 M0 x,5 *6) 0,800 7 4673 8,9 369 XP/DIP, Div. & T3 (60 C) 9,5 4 XP/DIP, Div. & T3 (60 C) -0... +60 Flying leads -0... +60 Flying leads 0,500 8 384 0,500 8 5 385 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *6) /cable gland not supplied, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Datasheet ATEX IECEx FM 37x, 38x CSA-LR 576-6 N/en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585 N/en 5.4.345.04 without notice, the specifications given in this document. 04 Norgren GmbH 006-538f 4/4
Solenoids group 6D, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) IP-Protection class (to EN 6059) (ATEX-Category) Temperature Ambient/Fluid 6,9 703-5... +60 9,5 75-5... +60 ( C) Electrical connection DIN EN 7530-803 DIN EN 7530-803 Weight Circuit diagram (kg) Nr. Nr. 0,6 3 0800 0,35 4 6 3803 6,9 703 II3G 9,5 75 II3G,4 475 IIG IID 5, 66 IIG IID,4 475 IIG IID Ex td A T 30 C Ex td A T 30 C Ex tb IIIC T30 C Db Ex tb IIIC T30 C Db Ex tb IIIC T30 C Db -0... +60 Special connector DIN EN 7530-803, 0,7 3 387-0... +50 Special connector 0,36 4 6 389 DIN EN 7530-803, M0 x,5 *6) 0,5 6 4 480 M0 x,5 *6) 0,5 6 7 48 / x 4 NPT *6) 0,8 7 0 4680 5, 66 IIG IID Ex tb IIIC T30 C Db / x 4 NPT *6) 0,8 7 468,4 475 IIG IID Ex tb IIIC T30 C Db M0 x,5 *6) 0,8 7 0 468 5, 66 IIG IID Ex tb IIIC T30 C Db M0 x,5 *6) 0,8 7 4683 3,6 567 XP/DIP, Div. & T3 (60 C) 5,7 68 XP/DIP, Div. & T3 (60 C) Datasheet ATEX IECEx FM 37x, 38x CSA-LR 576-6 N/en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585-0... +60 Flying leads -0... +60 Flying leads 0,5 8 386 0,5 8 5 387 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *6) /cable gland not supplied, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. 4/4 006-538f N/en 5.4.345.05 without notice, the specifications given in this document. 04 Norgren GmbH
Accessories Cable gland Protection class Ex e, Ex d (ATEX), Page 98Thread Cable Ø Material Protection class (ATEX) M 0x,5 5,0...8,0 mm Nickel plated brass IIGD Ex e 058889 057075 M 0x,5 0...4 mm Nickel plated brass IIGD Ex d 058885 /-4-NPT 7,5...,9 mm Nickel plated brass IIGD Ex d 058895 s Valves 66,5 7 8 3 7 9 7 30 3 7 9 9,5 ~ 8,5 4 3 3 4 Ports G/8 or /8 NPT M4 x 6 mm deep 3 Ports G/4 or /4 NPT N/en 5.4.345.06 without notice, the specifications given in this document. 04 Norgren GmbH 006-538f 4/4
s Solenoid operators 38 7 46 79 9,5 4,5 5,5 M6 X,5 8 9,5 7 M6 X,5 8 8 3 4 8 86,5 96,5 53,5 49 63,5 59 34 48 M6 X,5 8 7 33 4 34 7 M6 x,5 8 7 5 6 07 8,5 64,5 7 89 3 0 ± 0, 4 9,5 63,5 73 54,5 can be indexed by 4x90 Ø 6 or 3 (with spacer tube) 3 M0 x,5 or / - 4 NPT 4/4 006-538f N/en 5.4.345.07 without notice, the specifications given in this document. 04 Norgren GmbH
7 8 70,5 4,5 / - 4 NPT 0 53 3 59 56 4,5 + 84 63 33,5 9 6 4 Ø 6 or 3 (with spacer tube) 3 M0 x,5 or / - 4 NPT 4 Flying leads AWG 8 ( long) Circuit diagrams 4 5 6 7 0 T T Cable gland C B A D C B A D A B C ø D M0 x,5 9 36 5... 8 058889 M0 x,5 4 39 0... 4 4 058885 /-4 NPT 5 58 7,5...,9 4 058895 058895 only Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. N/en 5.4.345.08 without notice, the specifications given in this document. 04 Norgren GmbH 006-538f 4/4