CM-110SK Standalone Keypad Installation Instructions

Similar documents
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Waterproof. Keypad/Reader/Controller

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

W3-H Waterproof Keypad/Reader/Controller

Single Door Standalone Access Control User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

User Manual. PCKeypad Wireless Keypad

BC Digital Keypad. User Manual

DOLXFD1000B. Waterproof Access Control/Reader

Fingerprint Access Control F1. User Manual

VIDI-AC-2CS Access Controller/ Reader

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Digital Keypad Introduction

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

HSY-S209 EM Metal waterproof access control system User Manual

Stand-alone Proximity Access Control

-DTZ001- Stand-Alone Proximity Access Control. User Manual

User Manual. Split access control with intelligent secured power supply.

RBR-SB-KTZ001 LAR 2. User Manual

CV-945 Stand-Alone Biometric Reader. Installation Instructions

EL-ST100 KEYPAD CONTROLLER

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

CC Series metal access control Manual

Metal Standalone Keypad Access Control S100

VIS-3200 / VIS-3201 User Manual

Installation and User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

CM-500 SK 500 USER CODES KEYPAD

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Standalone Access Control

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

1. Product Specification

Installing Keypad and Backplate

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

2000 Series e/em Style Keypad Installation and Programming Manual

ACCESS CONTROL SYSTEM

_ Access control SISTEMAS DE SEGURIDAD

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

AS Keypad User Manual

KP2000E/EM Series Style Keypad

GV-AS Controller. Installation Guide

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

REX F-0-9 Standalone or Access Controller

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

CP150B Vandal & Weather Resistant Keypad Security Systems

Specifications: Features:

EX8. User Manual. Ver 1.0

FTK5 PROXIMITY KEYPAD

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

232iLM Keypad Installation and Programming Instructions

ACTsmart2 Product Range Operating and Installation Instructions

GV-RK1352 and GV-R1352 Card Reader

DG Series. Access Control Proximity Readers DG-160 DG-800

Connecting a Cisco Reader Module

WiFi Video Doorbell. User Manual

GV-Card Reader. User s Manual

GV-EL124S Electric Strike

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

6222 Two Door Module Technical Operations Manual

Fingerprint Identification Proximity Reader. Quick Installation Guide

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Revision Date: 02 Mar 2018

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Fast operation of IP Villa System V 1.0

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

232iLM Keypad Installation & Programming Instructions

Wireless Digital Video Doorbell

M-PROX2 Installation Instructions

WiFi Wireless Video Door Phone. User Manual

Outdoor Stand-Alone Weatherproof Keypads

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

Two Door Controller GEN-045

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Transcription:

CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm 30 mm) 0.6 x. Φ(4 mm 28 mm) 0.2 x 0.24 Φ(3 mm 6 mm) 5 5 6 " [50mm] 2 3 4 5 6 7 8 9 0 # * 3 4 " [44mm] 2. Description 3. Features The CM-0SK is a multifunctional standalone keypad with a wiegand output for interfacing to an access control system. It is suitable for mounting in either indoor or outdoor harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case. The electronics are fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000 users with a 4 digit PIN. The unit has many extra features including lock output current short circuit protection, wiegand output, and a backlit keypad. These features make the unit an ideal choice for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. 2000 users, 4 digit PIN Backlit keys Zinc Alloy Electroplated anti-vandal case Waterproof, conforms to IP68 Easy to install and program Full programming from the keypad Can be used as a stand-alone keypad Wiegand 26 input for connection to external reader Wiegand 26 output for connection to a controller Adjustable Door Output time, Alarm time, Door Open time Very low power consumption (30mA) Fast operating speed, <20ms with 2000 users Lock output current short circuit protection Built in light dependent resistor (LDR) for anti-tamper Built in buzzer Red, Yellow and Green LEDS display the working status Page of 6

4. Quick Reference Programming Guide To enter programming mode * Master Code # 999999 is the default factory master code To exit from the programming mode * Note: You must be in programming mode to program the following feature To change the master code 0 New Code # New Code The master code can be 6 to 8 digits User ID Number # PIN To add a PIN user The ID number is any number between & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 234 which is reserved. Users can be added continuously without exiting programming mode. To delete a PIN user 2 User ID Number # for a PIN user or Users can be deleted continuously without exiting programming mode. To unlock the door for a PIN user Enter the PIN then press # 5. Specifications Operating Voltage 2V DC ±0% User Capacity 2,000 Active Current < 60mA Idle Current 25±5 ma Lock Output Load Max 3A Alarm Output Load Max 20 ma Operating Temperature -49 F to 40 F (-45 C to 60 C) Operating Humidity 0% - 90% RH Waterproof Conforms to IP 68 Adjustable Door Relay time 0-99 seconds Adjustable Alarm Time 0-3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock, Exit Button, External Alarm, External Reader Dimensions 5 5/6 H x 3/4 W x D (50 mm x 44 mm x 25 mm) Page 2 of 6

6. Installation Remove the back cover from the keypad using the supplied special screw driver Drill 2 holes on the wall for the Self tapping screws and hole for the cable Put the supplied wall plugs into the two holes Fix the back cover firmly on the wall with the 2 Self tapping screws Thread the cable through the cable hole Attach the keypad to the back cover 7. Wiring Color Function Description Pink BELL_A Doorbell Pale Blue BELL_B Doorbell Green D0 Wiegand output D0 White D Wiegand output D Grey ALARM Alarm negative (alarm positive connected 2 V+) Yellow OPEN Exit button (the other end connected GND) Brown D_IN Door Contact switch (the other end connected GND) Red 2V+ 2V + DC Regulated Power Input Black GND 2V - DC Regulated Power Input Blue NO Relay Normally Open Purple COM Relay Common Orange NC Relay Normally Closed Common power supply diagram: BELL_A BELL_B D0 GREEN Bell - 2V + Power supply D WHITE ALARM GRAY OPEN YELLOW D_IN BROWN +2V RED + Alarm Exibit Button Door Contact GND NO COM NC Connect BLACK BLUE PURPLE ORANGE Fail Secure Lock Fail Safe Lock Page 3 of 6

8. Reset to Factory Default a. Disconnect power from the unit b. Press and hold # key while powering the unit back up c. On hearing two Beeps release # key, system is now back to factory settings Note: Only the installer data is restored, user data will not be affected. 9. Anti-Tamper Alarm The unit uses a LDR (light dependent resistor) as an anti-tamper alarm. If the keypad is removed from the cover, the tamper alarm will operate. 0. Sound and Light indication Operation Status Red Light Green Light Yellow Light Buzzer Power on - Bright - Beep Standby Bright - - - Press keypad - - - Beep Operation successful - Bright - Beep Operation failed - - - Beep/Beep/Beep Enter into programming mode Bright - - - In the programming mode - - Bright Beep Exit from the programming mode Bright - - Beep Open the door - Bright - Beep Alarm Bright - - Alarm. Detailed Programming Guide. User Settings To enter the programming mode * Master code # 999999 is the default factory master code To exit from the programming mode * Note that to undertake the following programming, the master user must be logged in To change the master code 0 New code # New code # The master code can be 6 to 8 digits long User ID number # PIN # To add a Pin user The ID number is any number between & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 234 which is reserved. Users can be added continuously without exiting programming mode as follows: User ID no # PIN # User ID no 2 # PIN # Page 4 of 6

To delete a PIN user To change the PIN of a PIN user (This step must be done out of programming mode) 2 User ID number # Users can be deleted continuously without exiting programming mode * ID number # Old PIN # New PIN # New PIN # To delete All users To delete ALL users. Note that this is a dangerous option so use with care 2 0000 # To unlock the door For a PIN user Enter the PIN then press #.2 Door Settings Relay Output Delay Time To set door relay strike time * Master code # 4 0~99 # * 0-99 is to set the door relay time 0-99 seconds Door Open Detection Door Propped Open Alarm. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after minute, the inside buzzer will beep automatically to remind people to close the door and continue for minute before switching off automatically. Door Forced Open Alarm. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened by force, or if the door is opened after 20 seconds of the electro-mechanical lock not being closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0~3 minutes with the default being minute. To disable door open detection. (Factory default) 6 0 # To enable door open detection 6 # Alarm output time To set the alarm output time (0~3 minutes) Factory default is minute 5 0~3 # Keypad Lockout & Alarm Output options. If there are 0 invalid cards or 0 incorrect PIN numbers in a 0 minute period either the keypad will lockout for 0 minutes, or the alarm will operate for 0 minutes, depending on the option selected below. Normal status: No keypad lockout or alarm (factory default) 7 0 # (Factory default setting) Keypad lockout enable 7 # Alarm and inside buzzer operate 7 2 # To remove the alarm To reset the Door Forced Open Alarm Master Code # To reset the Door Propped Open Alarm Close the door or Master Code # Page 5 of 6

2. The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input. BELL_A BELL_B D0 D GREEN WHITE Bell ALARM GRAY OPEN YELLOW D_IN BROWN +2V RED GND BLACK NO BLUE D0 D 2V GND Access Controller COM NC PURPLE ORANGE Connect 2. Keypad 8 bit Burst Mode Every key pressed generates an 8 bit data stream that is transmitted over the wiegand bus. Key Output Key Output 0 0000 6 0000 0000 7 0000 2 0000 8 0000 3 0000 9 0000 4 0000 * 0000 5 0000 # 0000 Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control 5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7 www.camdencontrols.com Toll Free:.877.226.3369 Page 8 of 6 File: Standalone Keypad Installation Instructions.indd R Revision: 25/0/206 Part No.: 40-82B9