AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)

Similar documents
NH908A Amplifier and Power Supply Installation and Use Instructions Used with the HT2006 Series Inside Handset Intercom Stations

APPLICATION PROCEDURE HOUSING INSTALLATION AND EQUIPMENT LOCATION

VM25WH Video Monitor Station (shown with HT2006/10 10-Button Handset)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Typical Wiring Diagram and programming for the FS1000 series 2-wire QwikBUS apt. intercom stations to a single entrance pushbutton door station.

2400 Series. Installation & Operations Manual. 42 Central Drive Farmingdale, NY

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Access Control for Houses 2 Wires Connection Doorline DR-200-SET Surface Mount Doorline DR-200-AV-SET Flush Mount

Tone Generator and Probe

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

LPWWS Smart Wi-Fi Wall Station

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

2000 Series e/em Style Keypad Installation and Programming Manual

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

INSTALLATION INSTRUCTIONS

STR QwikBus 2 wire Color Video Intercom System

LA600WH WIRED / WIRELESS DOOR CHIME

AT&T. ZoneMate 3 Service Manual. PagePac 20 Voice Paging System. MERLIN CS Connection And Operation

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Now with Picture Memory

MS-5000: MiniStar Reader

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

BA/BS4S Temperature Sensor Installation & Operating Instructions

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500

Model HM-535 Power Supply Installation and Service Instructions

MS-7000: SuperStar Reader

system AB-114 / AB-202 AB-404 / AB-301 AB-T2454 Multi-room audio distribution system CHANNEL VISION Limited Warranty

DP-222Q Color Video Door Phone Manual

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

User Manual CS-SA Series 'SUPER ANALOG' Time Fade Stations JOHNSON SYSTEMS INC.

TELEPHONES & CABINETS

JANUARY 2000 TS800A TS801. MicroScanner

2 WIRE video door entry system

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

Installation Instructions

DP-222Q Color Video Door Phone Manual

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

6222 Two Door Module Technical Operations Manual

INSTALLATION INSTRUCTIONS

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Digital Keypad Introduction

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions

Installation & Operation Guide

H7625A, H7635A Humidity/Temperature Sensors

INSTALLATION INSTRUCTIONS

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

All-Spec Industries Ph: Web: Wilmington, NC Fx:

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Data Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121

EP/2 Installation Instructions

Series 803 LED Product Price Display

INTERCOM SYSTEM Model ICA900

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

User s manual. Easy Scan XT3 LED

I need to protect my equipment against damaging power surges and spikes.

ICM-400 Series Intercom Stations

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

TECHNICAL MANUAL. 25H/DDA One button DDA audio intercom kit TECHNICAL MANUAL EDITION 1.1

212iL Rev. 1.1

Quick Start Installation Guide

Modem Installation and Networking Instructions

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

Installation Notes TII Model 341 Protector

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

AirTest Model CN9000 Series Sensor Controller

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Self-Adjusting Ultrasonic Wall Switch Sensor

Expandable Power Systems

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

HD View 12 Plus and HD View 6

VOICE-ACTIVATED INTERCOM SYSTEM

} Power ground. Mod ATLANTICO DOOR PHONES. ATLANTICO DOOR PHONES Mod Mod ATLANTICO DOOR PHONES TECHNICAL SPECIFICATIONS

Tek-ENTRY Telephone Entry System. Specification Sheets Submittal Package. as of 10/4/2010

V-9939C MICROPHONE ADAPTER

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

FDS / FDS-R / FDS-PS

RF-Link 2.4GHz Digital Wireless Color Security/Baby Monitor. Model: ABM-4161 User's Manual

Network Controller. Installation/Troubleshooting Instructions NK220 COM1131C

Transcription:

AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s) APPLICATION The AlphaStatus system allows one or more RSS402, RSS403, RSS404 and/or RSS405 room status stations to provide locking push-button registration (of up to 4 different colors) of the room status to the CDL104LED or CDL102LED corridor dome status light(s). When one or more optional master stations are used, the status registered by each room status station will also be displayed at each master station and other indicators based on the system configuration. A number of optional accessories are available to provide a complete signaling system. Models RSS403 and RSS405 also allows for optional audible signaling from a room location to the master location(s). PROCEDURE 1. Read installation instructions for each unit to determine equipment location and installation method. 2. Install housings and wiring. 3. Install equipment. 4. Check wiring and connect. Observe all local and national electrical and building codes. 5. Apply power and check operation, making sure to observe polarity where indicated. HOUSING INSTALLATION AND EQUIPMENT LOCATION Locate stations where needed at a convenient height, about 4.5 feet (137cm) from the finished floor. Unit can be flush mounted over a double gang electrical box or double gang plaster ring, or surface mounted using a double gang mounting box (with suitable inside clearance depth). CORRIDOR DOME STATUS LIGHTS Locate corridor dome status lights where needed, in the corridor outside of each room location. Typically, these dome lights mount right over the doorway to the room. They can be mounted on the side of the room door, but please mount them high enough to avoid anyone walking into the dome light portion that protrudes from the wall. Unit can be flush mounted over a double (or single) gang electrical box or double (or single) gang plaster ring, or surface mounted using a double gang mounting box (with suitable inside clearance depth). MASTER STATION(S) If one or more master stations are used, locate at a convenient viewing height (for wall mounting) or at a convenient viewing angle for desk or table-top mounting. PSR-24/6 POWER SUPPLY The PSR-24/6 power supply is usually located in a separate equipment location, but can be mounted near the master station (if used). The PSR-24/6 can be mounted on a small shelf, or other suitable location. It must be located away from any source of direct heat or extreme cold and in an accessible location. Keep at least 3 feet (1 meter) away from transformers, light dimmers or other electrical devices or wiring or sources of electrical interference. Plug the PSR-24/6 power supply unit(s) into a standard 117VAC electrical wall outlet. It is recommended that one PSR-24/6 power supply be used for each 18 room status stations (with full lamp lighting capability) or one for each 36 room stations (with 1/2 lamp lighting capability). WIRING When using a master station, the easiest wiring method is to home-run a #22AWG multi-conductor cable from each room status station directly to the master station location. Run a 5-conductor #22AWG cable from the room status station to its corresponding CDL104LED (4- LED) corridor dome status light, or 3-conductor #22AWG cable from the room status station to its corresponding CDL102LED (2-LED) corridor dome status light. For runs greater than 250 feet, increase the #22AWG cable to #18AWG cable. When a master station is not used, the easiest wiring method is to loop a 2-conductor #22AWG cable from the PSR-24/6 power supply from one corridor dome status light to the next, to supply power. Additional power (or common wires) may be needed as well, depending upon system options. Run a 5-conductor #22AWG cable from the room status station to its corresponding CDL104LED (4-LED) corridor dome status light, or 3-conductor #22AWG cable from the room status station to its corresponding CDL102LED (2-LED) corridor dome status light. For runs greater than 250 feet, increase the #22AWG cable to #18AWG cable. Cables may be straight or twisted pair type and may be solid or stranded conductors. Route cables away from AC power wiring, transformers, fluorescent lights, dimmers or Copyright 2005-2017, Alpha Communications, All Rights Reserved. AWD108 Rev. 7 (11/2017)

other electrical devices. Protect cables from damage. Shielded cable is not usually required, as this system has no voice or intercom capabilities, but a strong AC voltage could cause some system interference or lamp flickering. Shielded cables may be used (if desired) to prevent this type of interference. CONNECTIONS Before connecting, make certain wires are free from shorts or grounds. Make connections as shown on the specific wiring diagram for your system configuration, in this manual, and as detailed in the following instructions. 1. Connect the Common terminal 'C' on Room Status Station to the (-) from the 24VDC power. Connect the Common wire (that feeds one side of all of the LEDs) room location, in the hallway to the (+) from the 24VDC power. 2. Connect terminal 'R' on Room Status Station to the wire for the Red LED, on the corridor dome status light corresponding to that room location, and to terminal 'R' at the master station(s) for the Red LED for that room location. 3. Connect terminal 'W' on Room Status Station to the wire for the White LED, on the corridor dome status light corresponding to that room location, and to terminal 'W' at the master station(s) for the White LED for that room location. 4. (On RSS404 and/or RSS405 only) Connect terminal 'G' on Room Status Station to the wire for the Green LED, room location, and to terminal 'G' at the master station(s) for the Green LED for that room location. 5. (On RSS404 and/or RSS405 only) Connect terminal 'Y' on Room Status Station to the wire for the Yellow LED, room location, and to terminal 'Y' at the master station(s) for the Yellow LED for that room location 6. (On RSS403 and/or RSS405 only) If you wish to be able to send a tone signal to the master station(s) by depressing the momentary pushbutton at the room station, connect 1 wire from the pushbutton screw terminals to terminal 'B' on the TSM tone speaker module at the master station(s). Connect the other wire from the pushbutton screw terminals to terminal '1' on the IA543 (or PK543A) tone generator. OPTIONAL EMERGENCY PULL CORD(s) The model SF119/2A Emergency Pull Cords come from the factory with two (2) sets of two (2) pigtails wires, in different colors on the two (2) sides of the slide switch. The colors may vary, but for general wiring purposes we will refer to them now as Black and White. Each color represents a separate set of normally-open dry contacts. Both sets of contacts are closed when the pull cord is pulled (activated). When using the SF119/2A pull cords in a system you need to add the PK612A lamp flasher. NOTE: When using the optional SF119/2A Emergency Pull Cord(s) the Red color status indicators are reserved for Emergency only, and should not be used as one of the room status colors. POWER SUPPLY UNIT 1. Do not plug connect PSR-24/6 power supply primary to 117VAC until entire installation is complete and checked. 2. Observe polarity for the 24VDC output terminals. finish installation 1. Install stations on housings. Do not overtighten screws. 2. Install power supply and optional accessory devices as needed. 3. Plug PSR-24/6 power supply primary into 117VAC. 4. If IA543 (or PK543A) tone generator is used, connect the 16VAC transformer primary to 117VAC. 5. Be careful not to pinch any wires when installing stations into the wall or modules into the master station(s). 5. Observe all local and national electrical and building codes. master station labelling 1. Each AlphaStatus system has software to easily create and maintain your Master Station labelling/numbering. You can download this software free from our website at: www.alphacommunications.com, in the DOWN- LOADS section. test and checkout operating instructions ROOM STATUS STATION To SET STATUS (on): Individually depress any of the round locking switches at the Room Status Station that you wish to activate/light. The center of the switch will depress and lock in the 'down' position, and the center of the switch will turn from Black to Red color. The color associated with that switch (Red, White, Yellow or Green) will light at the corridor dome status light outside that room. If the system also has one or more Master Stations, the LED color associated with that switch (Red, White, Yellow or Green) will light at the Master Station(s). To SET STATUS (off): Individually depress any of the round locking switches at the Room Status Station that are Red color and the switch will pop back up and change to Black color. All lights and LEDs associated with that station and that switch color will turn off. To SEND TONE TO MASTER(s): On Room Status Stations so equipped (models RSS403 and/or RSS405), you can send a tone signal to the master station(s) by depressing the White rectangular pushbutton at the bottom of the station. The tone signal will sound for as long as you depress the White pushbutton. The tone volume can be set on the IA543 (or PK543A) unit. TROUBLESHOOTING If the system fails to operate as required, review operating instructions again. If the equipment fails to operate as indicated in the instructions, check the following points: 1. Entire System Dead: Check for 24VDC output at PSR-24/6 power supply unit(s) and at 16VAC transformer secondary (if used). Check connections for 117 VAC primary power at PSR-24/6 and transformer (if used). 1. At all inside Room Status Stations, make sure all of the locking switches are in the UP (out) position with the center color showing Black. All Dome lights and optional Master Station LEDs should be OFF. 2. No TONE at master station: First check for 2. Individually depress each of the locking switches at 16VAC power going to IA543 (or PK543A) terminals 'C' each Room Status Station and make sure the matching and 'K'. Depress the White tone buttons at several room Corridor Dome Status Light color and optional Master locations to see if it is a system-wide problem or just Station matching color LEDs light. Reset all locking for that room location. If it is just for that room location switches to OFF (Black) position. only, short out the 2 terminals in the back of the White 3. If the Room Status Stations are equipped with the White tone button. If the tone sounds, the pushbutton is likely momentary pushbutton, depress the button at each Room bad, so replace it with a new one. Remove wires from Status Station and verify that the tone signal sounds at TSM module terminal 'L' and 'B' and check for approx. each Master Station. 45 ohms (using an ohmmeter) across terminals 'L' and 4. If the rooms are equipped with the SF119 series Emergency 'B'. if the speaker shows 'open' replace the TSM tone Pull stations, pull the cord at each room and verify speaker module. If speaker shows approx. 45 ohms of that the Red LED flashes on the corridor dome status continuity, replace IA543 (or PK543A) tone generator. light, and the corresponding Red LED flashes at each Master Station. Verify that the tone signal sounds (and 3. NO LIGHT AT CORRIDOR DOME STATUS pulsates) at each of the Master Stations (if so equipped). LIGHT: If a particular color light does not activate 2 on the corridor dome status light, check that LED for 3 damage, or swap with a different color's LED to see if the problem is the LED or the power going to the LED, or wiring. You can also try swapping the wiring going to this LED and another LED to see if the wiring is the problem. The problem could also be the individual locking switch for that color at the Room Status Station. Swap out the wiring for that switch (terminal 'R', 'W', 'Y', or 'G') with a different switch, or momentarily jump the common terminal 'C' to the color terminal ('R', 'W', 'Y', or 'G'). If the light activates, replace the switch or the Room Status Station. 4. NO LED LIGHT AT MASTER STATION: If a particular color LED does not activate on the Master Station, swap with a different color's LED terminal to see if the problem is the LED or the power going to the LED, or wiring. If the LED is bad you can replace it individually or replace the entire RSM404 LED module with a new one. 5. LIGHT FLICKER: Check system wiring installed too close to power wiring or electrical devices or transformers; check transformer(s) installed too close to control equipment (should be at least three (3) feet away). Wiring is being run next to wiring for other systems and/or devices. Check to make sure you haven't exceeded the station capacity on the PSR-24/6 power supply unit(s). If these checkpoints fail to indicate the problem, there may be an equipment fault. Contact the factory or qualified service representative. NOTE: The Alpha Communications warranty is void if this system is installed or used in any manner other than described in this manual. PLEASE SEE NOTE ON PAGE 8 CONCERNING THE MOMENTARY SWITCHES FOR THESE SIGNALING PUSHBUTTONS ON THE RSM404 MASTER LED MOD- ULES, WHEN A MASTER STATION IS USED. RSM404 Master LED Module

TYPICAL WIRING DIAGRAM USING THE RSS405 NOTE: On each Room Status Station you must jump the two (2) 'C' (COMMON) terminals together! TYPICAL WIRING DIAGRAM USING THE RSS404 NOTE: On each Room Status Station you must jump the two (2) 'C' (COMMON) terminals together! on the RSS405 room status station if the SF119/2A is used in that room location. on the RSS404 room status station if the SF119/2A is used in that room location. 4 5

TYPICAL WIRING DIAGRAM USING THE RSS403 TYPICAL WIRING DIAGRAM USING THE RSS402 on the RSS403 room status station if the SF119/2A is used in that room location. on the RSS402 room status station if the SF119/2A is used in that room location. 6 7

TYPICAL WIRING DIAGRAM USING THE RSS405 ROOM STATUS STATION(S) AS A STAND-ALONE CONFIGURATION WITH NO MASTER STATION(S) NOTE: When using as a stand-alone configuration, use one (1) SS106 24VAC transformer for each individual system configuration. A special note concerning the RSM404 Master LED Module; Each RSM404 module has four (4) built-in low-voltage momentary pushbutton switches, which can be activated from the front by depressing one of the BELL SYMBOLs. These switches can be connected by using terminals 'S1' common terminal 'SC'. When shipped from the factory, terminal 'SC' is connected to the +24VDC power. If you wish to isolate these buttons from Fig. 1 the +24VDC power, you need to cut the jumper wire shown on Fig. 1. This will allow you to Jumper connect these switches to another, separate low voltage power source of your own, for any special signaling requirement you may have. Terminals SC, S4, S3, S2, S1 NOTE: S1 is top switch on module and S4 is bottom switch 1. All wiring (up to 200 feet in length) can be #22AWG, unless shown otherwise. 4. When using the optional SF119/2A Emergency Pull Cord station(s) the Red color status indicators are reserved for Emergency only, and should not be used as one of the room status colors. ALPHA COMMUNICATIONS 42 Central Drive Farmingdale NY 11735-1202 TOLL-FREE TECHNICAL LINE 1-800-666-4800 Phone: 631-777-5500 Fax: 631-777-5599 WEB: www.alphacommunications.com EMAIL: info@alphacommunications.com 8