CONTATTO. Module Connection The connections for the proper operation of WEBS module are shown in the next schematic diagram.

Similar documents
Domino DFWEB. DFWEB: interface module between Domino bus and Ethernet network with Web-Server function. Module Connection. Domino

DS LBT 20494

MPR52-ENG User Manual

MPR50-IEM User Manual

Installation & User Manual

INDEX. 20

Esempio con Google Play tore Example with Google Play tore

MPR30-ENG User Manual

MW MOC SUPPORTING AND TROUBLESHOOTING WINDOWS 10

MW MOC INSTALLING AND CONFIGURING WINDOWS 10

Reti di Accesso e di Trasporto (Reti di Accesso) Stefano Salsano AA2010/11 Blocco 4 v1

Programming through Web browser:

Video Decoder Setup Guide

Silex SD-320AN-03 Serial Server

EVX is a range of controllers for the management

MOC6231 Maintaining a Microsoft SQL Server 2008 Database

Sierra Wireless AirLink LS300. Setup Steps

RMS Analog Input Module

Quick Installation Guide

How to upgrade the firmware

Gateway configuration manual DMX - KNX TP EK-BK1-TP

Automatic Creation of Define.xml for ADaM

UR51 Industrial Cellular Router

Gateway configuration manual IP - KNX EK-BE1-TP

VISTA Transfer Station Setup

MWS3-3 - MOC NETWORKING WITH WINDOWS SERVER 2016

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

ETH002-2 Relays at 16A Technical Documentation

Contatto. ModDALI. DUEMMEGI s.r.l. - Via Longhena, MILANO Tel. 02/ Fax 02/ Rel.: 2.3 June 2017 Page 1 of 8

MSCE-11 - MOC HYBRID CLOUD AND DATACENTER MONITORING WITH OPERATIONS MANAGEMENT SUITE (OMS)

UR72 & UR75 Industrial Cellular Router

Steady green On hook. Slow flashing green Off hook. Off Port not ready. Off No link. Fast flashing green Upgrading firmware.

cornice vetro trasparente frame transparent glass

ANC-100e Ethernet to Data Highway Plus Adapter

Contents. Table of Contents

Cimetrics, Inc. B6000 BACnet/IP to BACnet/MSTP Router. User Manual V.2

MOC10215 Implementing and Managing Server Virtualization

MODEL: GR8-EM. Communication Adaptor GR8 Series

Domino DFDALI64. DFDALI64: DALI gateway. Address programming. Wiring diagram

UTM Content Security Gigabit Gateway CS-950

EVF 300 series is a range of controllers with elegant design for the management of different typologies of top-class electric ovens.

google adwords guida F511591EE4389B71B65D236A6F16B219 Google Adwords Guida 1 / 6

Short Instructions CG-S / IP-Router

ICP DAS IOP760AM FAQ. FAQ Version ICP DAS Co., Ltd

How to assign an IP address and access your device

F Series Indoor Fixed IP Camera. Quick Start Guide

Unified Office Gateway UMG-1000 / UMG-1000W. Quick Installation Guide

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

LAN Interface TCW120B

FOUR CHANNEL VIDEO SERVER

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Innovative Electronics for a Changing World INDEX

Contents 1. Summary

MSQ3-8 - MOC UPDATING YOUR SQL SERVER SKILLS TO MICROSOFT SQL SERVER 2014

Installation and operation manual EPIC

Technical Manual Nova: Cabinet Security Management System (CSMS)

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

MWS3-2 - MOC INSTALLATION, STORAGE AND COMPUTE WITH WINDOWS SERVER 2016

BLUE LOG XM / XC. Quick Start Guide. Version

Istruzioni passo passo per creare qualsiasi CUSTOM AWARD con BBLogger How to create step by step any CUSTOM AWARD by BBLogger

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

ETH044-4 SSR (230VAC) and 4 Digital IO

INFORMATICA INDUSTRIALE

IoT GSC-100 GSC-100. Table of Contents. SETUP GUIDE. GSC-100 Connection Overview. Version 1.0

04MAC03/03/01/001 RIMADIMA an INTERREG III B CADSES NP, An EU-funded project managed by the European Agency for Reconstruction

Premiertek AP Mbps Wireless-N Broadband Router Quick Installation Guide

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Errore 500 su installazione Phoca Gallery e Phoca Guestbook su Joomla 2.5. Scritto da ventus85 Domenica 12 Agosto :28

Corso: Installing and Configuring Windows 10 Codice PCSNET: MW10-4 Cod. Vendor: Durata: 5

Quick Start Guide REX 100 WAN WiFi. Version. 4 en. as of FW

How to assign an IP address and access your device

User can upgrade the firmware directly using the Web or Console.

Shaw Business Hitron Modem (CGNM-2250) Configuration User Guide

AXIS T8705 Video Decoder. User Manual

Technical characteristics (MICA)

PTZ Optics IP Joystick Controller Model Number: PT-JOY

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)

Analog Telephone Adapter Setup for Q-SYS Softphone

Sound Manager 2 User Guide

SISTEMA ANTE EVO 2 DOOR SYSTEM EVO 2

7NOX User Manual for Site Device. Book after-hours air conditioning in commercial buildings with ease.

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

WF-2402 Quick Installation Guide

Atlas ATLAS INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS TECHNICAL FEATURES ATLAS: PIN IN/OUT / GENERAL VIEW

MSPJ-14 - MOC PLANNING, DEPLOYING AND MANAGING MICROSOFT PROJECT SERVER 2013

Industrial Serial Device Server

Domino DFDALI. DFDALI: DALI gateway. Address programming. Wiring diagram

Installation Procedure Red Hat 7 with Netscape 6

GV-POE2401-V2 24-Port 802.3at Web Management PoE

LogicMachine5. LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire LM will enable you to

ANC-120e Compact USB to Data Highway Plus Adapter

Power Xpert Meter 2000 Gateway Card Kit

Video Server D1. User s Manual

1. Short description. 2. Features. 3. Technical parameters

Mediatrix Sentinel Quick Start. Dgw v January 30,

STS Web card for Upsilon/Epsilon STS (66073) STS Web card User Manual

LAN IP Setup Quick Start Guide

TCPIPINT-SCMN USER MANUAL. Manufactured by R.V.R ELETTRONICA S.p.A. Italy

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

Transcription:

: interface module between MCP XT controller and Ethernet network with Web-Server function module has been developed to be used in all applications of Contatto system where it is required to control the domotic system through an Intranet or Internet connection, without difficult configuration procedures; for this kind of applications, in association with the specific program for the development of graphical maps, module is very user-friendly. NOTE: the module can be used in Domino and Contatto plants, with the same firmware, because it is able to automatically recognize if the module is connected to DFCP or MCPXT; for the Domino case, refer however to the specific technical sheet. To use module, MCPGraph upgraded to the latest available version is required; this can be freely downloaded from the website www.duemmegi.it. requires MCP XT controller with firmware 3.0 or higher (main microcontroller). module can be used in two different operating modes: in the first one it acts as a bridge between a local Ethernet network and Contatto system, while in the second operating mode it can be used as a true WEB-Server, with web pages that can be created by the user. module allows to manage any Contatto bus variables, like: inputs status status and command of real outputs status and command of virtual points registers system clock Module Connection The connections for the proper operation of module are shown in the next schematic diagram. + Supply _ module has a 2-way terminal block for the connection to power-supply in the range 9 to 24V= (terminals + and -). On the opposite side, the module features an Ethernet connector and a 10-way connector allowing the connection to MCP XT controller by means of the provided flat cable. Three LEDs on the front panel show the operating status of the module: the green LED is on when the module is supplied, while the yellow and the red LEDs report more complex information (for more details see the LEDs meaning paragraph). A little hole on the front panel allows accessing to the Reset button; for more details see the related paragraph. module is housed in a 3M DIN standard module. + _ ON SYS SD DUEMMEGI MILANO-ITALY Web Server Module Power supply 24V= ±25% / 55mA Eth DEVICE + - + - SUPPLY / ~ BUS MCP XT The development of the maps to be loaded into module is supported by the specific tool named MCP- Graph; for details about the development of maps, see the manual Graphical Maps. WARNING: the present technical sheet is applicable to module with firmware upgraded to the latest available release. As shown before, module must be connected to a dc power supply in the range 9 to 24V. After that it is necessary to connect the module to the Ethernet network and to Contatto MCP XT controller; in this way module will be full operating. WARNING: for the connection to an Ethernet HUB, a straight cable category 5 must be used, whereas for the direct connection to a PC a cross cable is needed (both these cables are not provided). Rel.: 2.2 October 2012 Page 1 of 7

Operation module has been developed to be used in association with MCP XT Contatto bus controller, which does not require any configuration procedure. As said above, module can be used in two ways, as bridge (interface between MCP XT and Ethernet) or Web- Server. : bridge mode By means of the bridge operating mode, it is possible to make each operation allowed by the programming and diagnostics Tools (MCPGraph, MCP IDE). It is possible to use these tools through the local network (LAN) or through Internet (but in this case a VPN has to be enabled, or anyway the router must be set in a proper way) after having entered the IP address assigned to in the opening communication window used for the connection; in this way it will be possible to interact with Contatto system from any location in the world (see Configuration and setting up ). It is possible to differentiate, in this way, the maps for each user and therefore the controls that each user can perform. LEDs meaning Three LEDs (green, red and yellow) on the front panel of show the operating status of module. The green LED shows the power on condition; the red LED features the function of System LED (SYS) and it offers a visual signaling and flashing with different duration depending on the module operating status; the next table lists these modes: Red LED On [sec] Off [sec] MCP XT connected 0.1 1.5 MCP XT not connected 0.9 0.1 Wrong MAC address Fisso ---------- SD-Card not present 0.5 0.5 Reset in progress 0.1 0.1 If a polling is running trough the bridge mode, the flashing of red LED is fast and irregular. In the case of firmware upgrading, the red LED flashes with dimming effect. The yellow LED (SD) shows the access to the SD-card memory and it flashes in irregular mode when a client is connected in Web-Server mode. Reset button A little hole on the front panel allows the access to the Reset button; this button must be used only in the case of effective needing and it has the following functions: Reset of the module: while the module is powered, push and hold down the button; when the Red LED starts to flash quickly (after 2 seconds about) release the button. The bridge modality is MONO-CLIENT, therefore allows the access to only one user at a time (although at the same time with Web-Server users). : Web-Server mode By means of this modality it is possible to upload into a series of customized WEB pages that have been created through the proper Tool MCPGraph upgraded to the latest available version. Through this modality, module allows the interfacing to a common Web-browser (FireFox, Internet Explorer, etc.); to navigate across the WEB pages, a password will be required (even if this is optional). The pages loaded by the browser and stored inside the memory, must be created and customized according to the plant and to the user's requirement. About the development of these pages, see the Graphical Maps manual. Web-Server modality is MULTI-CLIENT; it is possible the simultaneous access to a maximum of 4 users (plus one user in bridge mode). It is also possible to use 5 different login/passwords, each one with its own credentials; it is possible to set username and password for an Admin user and 4 different usernames and passwords for the other users. Restoring of default parameters: while the module is powered, push and hold down the button; after 2 seconds about the Red LED starts to flash quickly. The flashing continues for 3 seconds about, after that the flashing slows down; after further 10 seconds, the Red LED return to flash quickly. At this time release the button and the default parameters (IP address, password, etc.) will be restored. Rel.: 2.2 October 2012 Page 2 of 7

Configuration and setting up After having properly connected the module, several simple configuration procedures must be executed in order to make the module well operating. To access to the configuration panel of the module it is possible to use any browser (FireFox, Internet Explorer, Google Chrome, etc.). WARNING: to modify the settings and the configuration of module, it is necessary to access as administrator. Step 1: users and password configuration In the address bar of the browser enter the following: It is possible to enable or disable the Auto login of each user in the event of a LAN connection: in practice for which the user has enabled the Auto Login, when connected to the LAN, will no longer provide the login credentials. However, using a remote connection, the login credentials are always required. To enable or disable the Auto Login is necessary, following the selection of user from the previous window, select Yes to enable Auto Login, or No to disable Auto Login. If each user have selected Yes for this option, the module proceed with the following hierarchy: user 1, user 2, user 3, user 4, Administrator. Taking the example of the admin user, the configuration window of the Auto Login option will be as follows: http://192.168.1.253/webpass.htm A window asking for user name and password will be shown; the default ones for the administrator access are: username: admin password: admin It is a good practice, first of all, to change the administrator and users login/password before to use the module. User names and passwords, as the other parameters, can be modified in any moments according to the requirements. The configuration page for passwords configuration is the following: For each saving the following page will be shown: To proceed with users configuration, select Passwords, otherwise select Reset to make operating the new settings. Otherwise select IP Configuration to proceed with the web parameters configuration described in the following. It is necessary to choose the wanted voice to modify and then, for each one, save the new settings. Step 2: IP configuration and web parameters After the configuration of the passwords it is possible to access to the configuration page. In the address bar of the browser enter the following: http://192.168.1.253/webconfig.htm Rel.: 2.2 October 2012 Page 3 of 7

The configuration page looks like the following: The upload page looks like the following: It is possible, in this configuration page, to set the wanted parameters for IP address, Gateway, Subnet Mask, and the Bridge Port. The shown values in the previous picture are the default ones. Change these parameters as required and then press the Save button; in this way will appear the following page: To upload the user's Web pages, push the button Browse and select the.bin file previously created on your computer (see Graphical Maps manual); at this time push the Upload button. If an error occurs during the upload, the following message will be shown: Select Reset to make operating the new settings; will appear the next message: A new login request will appear after 5 seconds. Step 3: uploading of html pages For the uploading of html pages (the user Web site), as mentioned in the Graphical Maps manual, it is necessary to enter in the address bar of the browser the following (assuming to have assigned the IP address 192.168.1.253 to module): http://192.168.1.253/webupload.htm Information Pages Entering the following address (the IP address 192.168.1.253 is supposed): http://192.168.1.253/webinfo.htm it is possible to show any parameters of module, as shown in the following picture: WARNING: the access to information page of module is granted only to Administrator. Rel.: 2.2 October 2012 Page 4 of 7

Diagnostics In the address bar of the browser enter the following: http://192.168.1.253/webdiag.htm in this way it is possible to show the SD-CARD status and the connected unit. The related screen-shot is the following: This page shows all settings previously assigned, and the Firmware version of (FW v2.0 for the example in the previous picture); from this page it is not possible to modify any parameters. By clicking on IP Configuration it is possible to go back to the configuration page of module (.../webconfig.htm). Connected users info It is possible to monitor the connected users in Web-Server and Bridge modality: in the address bar of the browser enter the following: http://192.168.1.253/webconn.htm WARNING: the access to diagnostic page is granted only to the Administrator. Logout To close the connection with module, however optional operation, it is necessary to execute the logout from the module entering in the browser bar the following address: http://192.168.1.253/weblogout.htm A message confirming the logout will be then shown. Remote Reset If unexpected events occur, causing the blocking of module, it is possible to use a special command to execute the RESET of the module from a remote location (through the network); this RESET is similar to the hardware reset of module. In the browser bar enter the following address: http://192.168.1.253/webreset.htm As shown in the previous screen-shot, the first 4 lines report the IP address of the connected users in Web-Server modality, and the fifth-line reports the connected user in Bridge modality. WARNING: the reset of module is granted only to the Administrator. Each time that a change has been made to the configuration parameters, it is necessary, to be operative, to RESET the module. WARNING: the access to the connected users page is granted only to the Administrator. Rel.: 2.2 October 2012 Page 5 of 7

Firmware Updating To execute the Firmware Update of module, the program Boot upgraded to the latest available version. It also requires that the PC is connected to the RS232 serial port of MCP-XT (or, in alternative, RS485 by a specific converter). MCP-XT must be connected to the module to be updated through the specific flat cable. MCP-XT must have main firmware upgrade. Select Communication and the Program ; in this way the following window will be shown. Start the Boot program, the following will be shown: The ID & Ver button allows to visualize the current version of the firmware uploaded in the module. Click on the button Activate Boot ; the red LED on module will start to flash with dimming effect, shown that the module is ready to receive the new firmware. Then press the button Program and wait for the end of the operation. At the end of upgrading, to make operating the module, click on button Reset PIC, then select Close to quit the program. From the menu select Communication ; the window shown in the following picture will be opened. Press the button Automatic Detection to enable the communication with MCP XT, then press the button Close. Technical characteristics Power Supply 9 24V SELV MAX current consumption 105mA @ 9V 55mA @ 24V MCP XT Interface Proprietary SPI interface Ethernet interface 10/100BaseT Ethernet Housing DIN standard 3M per guida DIN Operating temperature -5 +50 C Storage temperature -20 +70 C Protection degree IP20 Outline dimensions + _ ON SYS SD An Ethernet connection can be used by the specify of the IP address of connected converter to the serial port of MCP-XT; this converter can NOT be the same in bridge modality. From the program menu select File and then Open ; it is possible, in this way, to load the.hex file to be downloaded into module. DUEMMEGI MILANO-ITALY Web Server Module Power supply 24V= ±25% / 55mA Eth 53mm DEVICE 90mm 58mm Rel.: 2.2 October 2012 Page 6 of 7

Smaltimento Il simbolo del cassonetto barrato riportato sull apparecchiatura o sulla sua confezione indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente dagli altri rifiuti. L utente dovrà, pertanto, conferire l apparecchiatura giunta a fine vita agli idonei centri di raccolta differenziata dei rifiuti elettronici ed elettrotecnici, oppure riconsegnarla al rivenditore al momento dell acquisto di una nuova apparecchiatura di tipo equivalente, in ragione di uno a uno. L adeguata raccolta differenziata per l avvio successivo dell apparecchiatura dismessa al riciclaggio, al trattamento e allo smaltimento ambientalmente compatibile contribuisce ad evitare possibili effetti negativi sull ambiente e sulla salute e favorisce il reimpiego e/o riciclo dei materiali di cui è composta l apparecchiatura. Lo smaltimento abusivo del prodotto da parte dell utente comporta l applicazione delle sanzioni amministrative previste dalla normativa vigente. Prescrizioni di installazione e limitazioni d'uso Norme e disposizioni La progettazione e la messa in servizio di impianti elettrici deve avvenire attenendosi alle norme, direttive, prescrizioni e disposizioni in vigore nella rispettiva nazione. L installazione, la configurazione e la programmazione dei componenti deve essere eseguita esclusivamente da personale qualificato. L installazione ed il collegamento della linea bus e dei dispositivi correlati deve essere eseguita in conformità alle indicazioni del costruttore ed alle norme vigenti. Tutte le norme di sicurezza vigenti, come per esempio norme antinfortunistiche o leggi su mezzi o strumenti di lavoro, devono essere rispettate. Indicazioni di sicurezza Proteggere l apparecchio, sia durante il trasporto, l immagazzinaggio e durante il funzionamento, da umidità, sporcizia e danneggiamenti vari. Non utilizzare l apparecchio in modo non conforme ai dati tecnici specifici. Non aprire mai il contenitore. Se non diversamente specificato, installare in contenitore chiuso (es. quadro elettrico). Se previsto, collegare il terminale di terra. Non ostacolare il raffreddamento dell apparecchio. Tenere lontano dalla portata dei bambini. Messa in servizio L assegnazione dell indirizzo fisico e la configurazione di eventuali parametri si realizza con gli specifici programmi forniti o con l'apposito programmatore. Per la prima messa in funzione del dispositivo procedere nel modo seguente: Accertarsi che l impianto non sia in tensione Indirizzare il dispositivo (se previsto) Montare e cablare il dispositivo secondo gli schemi indicati sul foglio tecnico di riferimento Solo successivamente inserire la tensione d esercizio 230Vca per l alimentatore del bus e gli altri circuiti correlati. Conformità normativa Questo dispositivo è conforme ai requisiti essenziali delle direttive: 2004/108/CE (EMC) 2006/95/CE (Low Voltage) 2002/95/CE (RoHS) Nota Le caratteristiche dichiarate ed il presente foglio tecnico possono essere soggetti a modifiche senza preavviso. Rel.: 2.2 October 2012 Page 7 of 7