Compact circuit breakers, with diagnosis included. Small, fl exible, effi cient.

Similar documents
Air circuit breakers with Power Xpert Releases PXR are ready to interact with operators via USB port.

IZMX Series Air Circuit Breakers. Small, flexible, efficient

IZMX series Air Circuit Breakers with Power Xpert Releases PXR

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Safe, seamless, smart

Metering module NZM-XMC

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

60103 Circuit Breaker

Product Guide. UL 1077 DIN Rail Supplementary Protectors

SENTRON 3VL Molded Case Circuit Breakers

Product Guide. UL 489 DIN rail miniature circuit breakers

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Eaton convincing in terms of safety, performance and operational availability. xenergy Switchboard. Switching to perfect

CP30F Series Circuit Protector for Improving Safety and Wiring Workability

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

UL 489 DIN Rail Miniature Circuit Breakers

High Safety low voltage switchgears For maximum requirements far beyond all standards.

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

UL 489 DIN Rail Miniature Circuit Breakers

MP-4000 motor protection. Protection, control and diagnostics

SACE Emax 2 Specification guide

Applying branch circuit breakers and supplementary protectors in North America

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry.

CENTERLINE 2500 Motor Control Centers

4. CIRCUIT BREAKERS. Functional Emergency Switching

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

UL 489 DIN rail branch circuit breakers

Applying branch circuit breakers and supplementary protectors in North America

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Miniature Circuit Breakers and Supplementary Protectors. Contents

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

VisoVac padmount fault interrupter

SVX9000 Adjustable Frequency Drives. Modular, Configurable, Compact

Power Xpert CX - Power distribution switchgear IEC Low Voltage Power Distribution Center and Motor Control Center. Power Xpert CX

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Air Circuit Breakers. 1/2 Introduction

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Section 4 Ground-Fault Protection Devices

WMS SUPPLEMENTARY PROTECTORS

Operating comfort redefined Frequency Inverters M-MAX

EntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability.

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Reliable Switchgear from One Proven Supplier

3VA molded case circuit breaker up to 1600A. Frei verwendbar Siemens AG 2018

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

920 Remote Control (RC) Switches

1492-SP Supplementary Protectors

Lean Line for the Machine

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

ASCO 920 Remote Control (RC) Switches

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

SENTRON Switching and Protection Devices Air Circuit Breakers

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

The 3VA molded case circuit breaker.

Protection relays.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

INCOM communications adapter module

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

SECTION SWITCHBOARDS

RB60 RANGE. Miniature circuit breakers

NW08 to NW63 fixed circuit breakers Circuit breakers

Application Techniques CENTERLINE 2100 Motor Control Centers

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Miniature Circuit-Breaker IEC Series 8562

Innovation for MV distribution

PM Series Power Meter

Air-insulated medium-voltage secondary distribution switchgear

HIGHLIGHTS Innovations for your success

SECTION DISCONNECT SWITCHES

HIGHLIGHTS Innovations for your success

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Jtec 10kA Miniature Circuit Breaker

Spectra RMS Circuit Breakers with microentelliguard Trip Units

Motor control and protection Universal Motor Controller UMC100-FBP

Transcription:

Compact circuit breakers, with diagnosis included. Small, fl exible, effi cient.

Versatile circuit breakers up to 4000 A for cost-effective, optimized solutions. The IZMX16 of the NRX series is the smallest air circuit-breaker (ACB) worldwide: With a volume of only 24 dm 3 and a front surface of only 0.092 m 2 it is just slightly bigger than the size of a DIN A4 sheet of paper! And all this without any loss in terms of performance. The innovative concept allows the user to install two circuit breakers side by side in withdrawable design, in a 600 mm wide section. This fact provides for a more cost-effective setup of the section and, in addition, it helps to save operating space. And where remote switching is required, this volume can even accommodate a motor for pre-tightening the stored-energy spring mechanism and some magnetic coils for the on/off command. More performance in less space is simply impossible. The IZMX40 of the NRX series is a circuit breaker for up to 4000 A in a volume of a 3200 A circuit breaker, without the need to install any additional copper mines in the connection area. Tests to integrate it into Eaton switchgear systems, such as Modan, xenergy, PowerXpert, Capitol 20 and Capitol 40 confirm its outstanding technical data and optimal compatibility thanks to the flexible connection system. The modular structure, integrated detail solutions as well as a complete range of accessories and additional functions make it easy to adapt the circuit breaker to any of the required applications. Optionally it can be adapted right at the factory without any extra cost for additional installation work at the circuit breaker. 2

Performance list. Circuit breakers of the NRX series offer different rated currents for a wide range of applications: From 630 A to 4000 A and a breaking capacity from 42 ka to 105 ka. In addition, it is also possible to optimally adjust the protective parameters in the electronic tripping system to the application or the operating material to be protected. So the NRX circuit breaker series can be used for many different purposes. Main areas of application are: System protection Motor protection Transformer protection Generator protection In order to increase the functionality of the circuit breaker in the application (e.g. for signalling, automation or communication purposes) we provide a wide range of real-workingworld oriented accessories. Even if you wish to temporarily oversize a system due to several development stages, a 1600 A circuit breaker can be precisely adjusted to an operating material of only 100 A just by replacing a rated current module. Sizes Versions IEC60947 Maximum breaking capacity at: U e 415/690 V: I cu (ka) I cs (ka) I cw (ka) IZMX16 630 A, 800 A, 1000 A, 1250 A, 1600 A 65/42 50/42 42 IZMX40 800 A, 1000 A, 1250 A, 1600 A, 2000 A, 2500 A, 3200 A, 4000 A 105/85 105/85 85 Section width for xenergy and MODAN switchgear systems Fixed design Width 3-pole (mm) 400 1000 Width 4-pole (mm) 600 1000 Withdrawable design Width 3-pole (mm) 400 1000 Width 4-pole (mm) 600 1000 Rated current I n, (A) 630-1600 800-4000 I cu at U e = 440/690 V AC I cu : Rated ultimate short-circuit breaking capacity at rated operational voltage U e I cs : Rated service short-circuit breaking capacity at rated operational voltage U e Basic switching capacity (B) Normal switching capacity (N) High switching capacity (H) 440 V AC, I cu, ka 42 / 42 66 / 66 690 V AC, I cu, ka 42 / 42 66 / 66 440 V AC, I cu, ka 50 / 50 85 / 85 690 V AC, I cu, ka 42 / 42 75 / 75 440 V AC, I cu, ka 65 / 50 105 / 105 690 V AC, I cu, ka 42 / 42 85 / 85 I cw t = 1 s, I cw = Rated short-time withstand current Basic switching capacity (B) 42 66 Normal switching capacity (N) t = 1 s, I cw, ka 42 85 High switching capacity (H) 42 85 I cm at U e = 440/690 V AC I cm : Rated short-circuit making capacity (maximum prospective peak value) at rated operational voltage U e Basic switching capacity (B) 88 144 Normal switching capacity (N) 440/690 V AC, I cm, ka - 166 High switching capacity (H) - 231 3

Profibus-DP Modbus Ethernet IZMX16 Increased operating safety and fl exibility based on communication. Thanks to its ability to communicate, the NRX circuit breaker series taps new opportunities for power distribution. It provides all the information that is relevant for operation and forwards it. This way the transparency of the system can be increased and response times to statuses such as overcurrent, phase imbalance and overvoltage can be reduced. By quickly intervening in a process, system standstills can be prevented or preventive maintenance actions can be planned. Consequently, the availability of the system can be increased as well. 4

Profibus-DP Modbus Ethernet IZMX40 Interface modules for Profibus, Modbus and Ethernet can now easily be plugged onto the circuit breaker, between the control line connections. With the respective communication module PCAM, MCAM or ECAM (Profibus-DP / Modbus / Ethernet Communications Adapter Module) every circuit breaker of the NRX series is equipped for modern communication and is fit for the future. The databus not only allows to transmit information, but also to receive commands/settings. 5

IZMX System Overview. IZMX16 IZMX40 10 3 11 8 2 13 14 22 22 8 8 12 15 22 16 17 1 18 19 20 4 21 23 7 6 24 25 26 5 9 7 27 6

IZMX16, INX16, IZMX40, INX40 1 IZMX Circuit-breaker IZMX16: 630-1600 A IZMX40: 2000-4000 A 14 Closing releases Closes the breaker by an electrical signal. 0 1 6 2 3 3 4 3 9 2 Cassette for withdrawable units Shutters 3- and 4-pole With and without control circuit terminals 3 Main terminal kits Universal terminals, 3- and 4-pole horizontal/vertical 4 Shutter Shutter for 3- and 4-pole 5 Motor operator Automatic charging of the spring force storage for remote or local operations 6 Current sensor for neutral conductor Current sensor for sensing the neutral-conductor-current. 7 Levering tool Convenient collapsible lev-in tool for lev-in and out operation of the Breaker in and out of the Cassette. The lev-in tool is stored inside the breaker. 9 Position cell switches Cell switch signals the position of the breaker inside of the cassette. Connect, Test and Disconnect Position. 9 Door escutcheon Closes the gap between Breaker and Switchgear-door. IP41. An IP55 protective cover is available as well 15 Key locking Locking of the breaker by a keylock. 16 Shunt releases Opens the breaker by an electrical signal. 17 Undervoltage releases Opens the breaker by a voltage-drop in the controlcircuit. 18 Red-pop trip indicator Red-pop trip indicator signals a trip by the trip unit. 19 Trip indicator switches Overcurrent trip switch (OTS) signals a trip by the trip unit for remove signalisation. 20 Switching operations counters Counts the number of operations. 21 Auxiliary contacts Signalling switch ON-OFF 22 Locking facilities Plastic or metal 23 Trip unit Digitrip 520; A-type 24 Trip unit Digitrip 520LSI; V-type 25 Trip unit Digitrip 520M; U-type 26 Trip unit Digitrip 1150i; P-type 5 10 Communication modules Profibus DP, Modbus, Ethernet 11 Control circuit terminal units Either 8, 20 or 30 units 12 Latch check switch For external application usage. 13 Latch check switch For use with closing release. 27 Rating plug Reduces the Rated Current of the breaker. 7

Individual solutions combined with IZMX. Adding individual solutions to IZMX circuit breakers provides both more protection for systems and more safety for personnel in case there is a failure. And it also reduces the risk of unintended interruptions of operation. These solutions include: ARMS TM ARCON Zone selectivity Remote switching Profi protection through Digitrip 1150 SAFETY ARMS TM (Arcflash Reduction Maintanance System) This system guarantees even more safety for maintenance staff. Overcurrent or dangerous arc flashes will lead to accelerated breaking of the contact and therefore reduce the energy that is set free (radiation, pressure, temperature). An accelerated switch-off happens even faster than the switch-off of a non-delayed short-circuit trip. This function can be activated either directly on the circuit breaker through an external switch, automatically, or via the communication bus. SAFETY ARCON IZMX breakers, combined with ARCON, help users to avoid damage and to protect people against arc faults as they can effectively be brought under control within 2 ms. They also protect against arc flashes that due to their impedance - would not even cause a protective device to react. SAFETY 8

Zone selectivity ZSI Circuit breakers are directly connected to a signal line, without any additional modules. So, in case of a malfunction, they ensure that only the circuit breaker immediately upstream the point of failure will break a short-circuit without delay. For additional safety of maintenance staff we recommend a combination with ARMS to reduce the released amount of energy even further. The advantage of the zone selectivity feature compared to ordinary time selectivity - is the significantly reduced time until switch-off and the reduced amount of energy released in case of a short-circuit. Remote switching Remote switching requires two magnetic coils (make-contact and operating-current trip). These coils will activate the mechanism of the ON and OFF buttons. After two switching actions have been carried out, a stored-energy spring mechanism needs to be retightened manually. With an additional motor drive, the retightening action can be automated. Safety: If the second switching action was an ON action, a third action for switch-off or tripping through the energy of the spring will be ensured. Safety: OFF commands will always be given priority. A permanent command for the operating-current trip enables the user to lock the circuit breaker in the OFF position. Thanks to the powerful storedenergy spring, the circuit breaker will carry out the switch command sent to the magnetic coil in less than 35 ms. So the NRX series circuit breakers are suitable for synchronized tasks. Profi protection with Digitrip 1150i With the high end type P trip technology (Digitrip 1150i) you can display functions such as parameterization, protection, measuring, network analyses, diagnosis and event memory on an integrated, high-resolution colour display, transmit them to any remote place via a communication module, display them on a homepage or send them to any place in the world by e-mail. Handling is intuitionbased. The keys allow you to scroll icons on the display for basic tasks/settings. The keys allow you to easily select the required function. 9

Convenience for planning, selection and documentation Eaton Configurator for Circuit Breakers The intuition-based software tool makes it easy to select and configure circuit breakers and load disconnectors with their respective accessories from a database of several thousand articles. It does not require any special knowledge of the system. With just a few clicks you can select any switchgear configuration and transfer it to the parts or ordering list. All combination possibilities are saved in the software logic, which ensures correct ordering. In a logical step-by-step order, the software will guide you through the switchgear offer and the suitable accessories. The selection process starts with choosing the appropriate standard, i.e. IEC or UL/CSA, the rated operating voltage and the rated frequency. In the following steps you will need to: Determine the number of poles Choose a circuit breaker or load disconnector Choose the protection task (e.g. motor protection, cable/ line protection) Decide on either fixed or withdrawable design Download from: www.moeller.net/de/products_solutions/index.jsp CurveSelect CurveSelect allows the user to simultaneously display setup-specific tripping curves of several protective devices both in terms of time and electric current values. This tool makes it easy for the user to analyze the interaction of NZM and IZM circuit breakers, PKZ motor-protectors, motor-protective relays, MCBs and h.b.c. fuses. Freely defined curves (Free- StyleCurves = FSC) enable the user to directly compare the selected motor protector and motor starter characteristics, incoming supply switches and up-stream medium-voltage protection intended expansions and existing protective equipment Download from: www.moeller.net/de/products_solutions/index.jsp BreakerVisu BreakerVisu allows the user to monitor several ACBs and MCCBs and helps him to quickly detect and clearly visualize the status of circuit breakers, such as currents, switching statuses or load warnings, and to dynamically visualize them on an http page. In addition, all events will automatically be recorded in a log file. This information is necessary to correctly evaluate warnings and malfunctions and to take the appropriate steps. Keeping a log file will also enable you to carry out an additional error analysis. BreakerVisu is composed of ready-made hard and software components. So no special software needs to be installed on the PC. All you need is an Internet browser and Microsoft Excel! Download from: www.moeller.net/de/products_solutions/index.jsp 10

Availability and delivery. In order to ensure short delivery times, technical feasibility of the combinations will automatically be checked at the time the order is entered into the SAP program. So any possible errors can be eliminated right away. Then the final assembly of the switchgear will be done at the nearest final assembly center, in line with the order. Once all accessories have been added, an automatic final test will be carried out. Test data will then be transmitted online, via the Internet, monitored and saved. Each circuit breaker carries an ID number that the data will be assigned to. This makes it easier to communicate with the end-user at any later point in time. Delivery is carried out from our state-ofthe-art logistic center, where the circuit breakers will be united with any other products that may have to be delivered to the same address. They will then be shipped at the same time. Technical support. Eaton s technical support is both competent and reliable. New customers are offered optional training on how to build a design-verified switchgear assembly. The advantage of realizing the first switchgear assembly directly with the panel builder is an opportunity to communicate the optimal workflow. 11

Eaton s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton s full-scale engineering services, these products provide customer-driven PowerChain solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, commercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Published by: Eaton Industries (Austria) GmbH Scheydgasse 42 A-1215 Vienna 2011 by Eaton GmbH, Austria Subject to technical modifi cations. No responsibility is taken for misprints or errata. Printed in Austria (10/11) Graphic design: THEREDBOX www.theredbox.at Printing: Rabl, Schrems BR01305001Z-EN Article No.: 166677 The products presented are part of the comprehensive Eaton offer. For more information, please contact your Eaton consultant. www.eaton.com