DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB. 10/100 BASE-TX LINK DC1 X1 X1 DC2

Similar documents
User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage.

Viper 20A Series. 20 port Ethernet M12 switches. User Guide REV. C. Westermo Teleindustri AB. X9 X15 X16 X17 X10 X11

Viper-12A. 12 port Ethernet M12 switch. User Guide Westermo Teleindustri AB. ON USB X2 X3 RSTP FRNT CON V ON USB

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender.

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB. X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch.

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller.

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card.

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch.

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

User Guide. Westermo Teleindustri AB BRD-355. Industrial ADSL/VDSL Router.

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

MCW-211-F1G-T1G. Industrial Ethernet Media Converter.

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

Wolverine DDW DDW Industrial Ethernet Extender WeOS

User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch.

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

ODW-621 Fibre Optic Modem

ODW-622 Fibre Optic Modem

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

TN-5308 Quick Installation Guide

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Output Voltage* (nom.)(adjustable)

TU531, TU532 Terminal Unit

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

Industrial Routing Switch

AO523 Analog Input Module

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender.

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

TF501, TF521 Terminal Bases

MC 11 EB-2 Power supply cabinet with external bus, AC version

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

LNX-0702G-SFP Series

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

Safety Standards. Model Number:

RedFox Industrial Series

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

PSC600-series DC/DC W

PTC-101-M12 Hardware Installation Guide

Output Voltage* (nom.)(adjustable)

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Ethernet Extender with serial support DDW-226

Documentation on all Paxton products can be found on our web site -

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

AX521 Analog Input/Output Module

AI561 Analog Input Module

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

5 B&W Rear View System Camera

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

FL MC 2000E (SM40) LC

Industrial Routing Switch

LNX-1002C-SFP Series

IEEE BASE-T IEEE 802.3u 100BASE-TX. ITU-T -G.993.1(VDSL) -G compatible

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

RTU500 series Data Sheet Power Supply CP-E 24/2.5

AX522 Analog Input/Output Module

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

Industrial 3-Port Fast Ethernet Media Converter Switches

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

CM597 Ethernet Communication Module

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

MRD-405. Industrial M2M/4G Gateway/Router GSM / GPRS / EDGE / HSDPA / HSUPA / HSPA/ 4G LTE. User Guide Westermo Teleindustri AB

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Quick Install Guide. Compex 8 Port Dual Speed Fast Ethernet Switch PS2208B. Version 1.1C

Transcription:

User Guide 6641-2280 DDW-002-B1 Westermo Teleindustri AB 10/100 BASE-TX LINK DC1 X1 X1 DC2 LINK STATUS ACTIVITY LINK MASTER ON POWER M12 Torque 0,6±0,1Nm / 0,45±0,1 lbft EN 50155 Ethernet Broadband Bridge www.westermo.com

Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address: http://www.westermo.com 2 6641-2280

Safety! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from all power supply. Ensure compliance to national installation regulations. This unit relies on convection heating. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. Also check chapter EN 45545-2 mounting notes. Before mounting, using or removing this unit: Prevent access to hazardous voltage by disconnecting the unit from all power supply.! WARNING Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². Note that this unit can be connected to two different power sources. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. 6641-2280 3

Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations: Do not attempt to dissassemble the unit. There are not any user serviceable parts inside. Do not drop, knock or shake the unit. Rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not expose the unit to any kind of liquid (water, beverages, paint etc), unless all connectors are connected or fitted with protective caps (delivered with the unit), tightened to the specified torque. Connected cables must have the appropriate ingress protection code. Do not use or store the unit in dusty or dirty areas, unless all connectors and the ventilation membrane are sufficiently protected. Do not cover or bring mechanical force to the ventilation membrane on the back of the unit. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. 4 6641-2280

Agency approvals and standards compliance Type EMC Safety Environmental Approval / Compliance EN 61000-6-1, Immunity residential environments EN 61000-6-2, Immunity industrial environments EN 61000-6-3, Emission residential environments EN 61000-6-4, Emission industrial environments EN 50121-3-2, Railway applications Rolling stock apparatus EN 50121-4/IEC 62236-4, Railway signaling and telecommunications apparatus IEEE 16 - IEEE Standard for Electrical and Electronic Apparatus on Rail Vehicles Tested and verified for FCC part 15, class A EN/IEC 60950-1 IT equipment EN 50124-1 Railway applications Insulation coordination EN 50155 Railway applications Electronic equipment used on rolling stock EN 61373 Railway applications Rolling stock equipment. Shock and vibration tests IEC 60068-2-27 Shock IEC 60068-2-64 Vibration, broadband random and guidance IEEE 1478 Environmental conditions for transit rail car electronic equipment EN 45545-2 Fire protection FCC Part 15.105 Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter ference to radio communications. However, there is no guarantee that interference will not occur in a partic ular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/tv technician for help. 6641-2280 5

Declaration of Conformity Westermo Teleindustri AB Declaration of Conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no Ethernet Broadband Bridge DDW-002-B1 3641-0900 is in conformity with the following EU directive(s). No Short name 2014/30/EU Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 2014/35/EU Low Voltage Directive (LVD) References of standards applied for this EU declaration of conformity. No Title Issue EN 50121-3-2 Railway applications Electromagnetic compatibility Rolling stock - 2015 Apparatus EN 50121-4 Railway applications Electromagnetic compatibility Emission and immunity 2015 of the signaling and telecommunications apparatus EN 61000-6-1 Electromagnetic compatibility - Generic standards - Immunity for residential, 2007 commercial and light-industrial environments EN 61000-6-2 Electromagnetic compatibility - Generic standards - Immunity for industrial 2005 environments EN 61000-6-3 Electromagnetic compatibility Emission for residential environments 2007 + A1:2011 EN 61000-6-4 Electromagnetic compatibility - Generic standards - Emission standard for industrial environments 2007 +A1:2011 EN 60950-1 Information technology equipment - Safety - Part 1: General requirements 2006 +A11: 2009 +A1: 2010 +A12: 2011 +A2: 2013 EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances 2012 The last two digits of the year in which the CE marking was affixed: 16 Pierre Öberg Technical Manager 2 nd December 2016 Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 6 6641-2280

Type tests and environmental conditions Environmental phenomena Basic standard Description Test levels ESD EN 61000-4-2 Enclosure Contact: ±6 kv Air: ±8 kv Fast transients EN 61000-4-4 Power port ±2 kv Signal ports ±2 kv Earth port ±1 kv Surge EN 61000-4-5 Power port L-E: ±2 kv, 12Ω, 9 μf, 1.2/50 μs L-L: ±1 kv, 2Ω, 18 μf, 1.2/50 μs L-E: ±2 kv, 42Ω, 0.5 μf, 1.2/50 μs L-L: ±2 kv, 42Ω, 0.5 μf, 1.2/50 μs Ethernet ports L-E: ±2 kv, 2 Ω Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 50, 60 Hz Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 MHz 2.7 GHz) 1 khz sine, 80% AM 10 V/m @ (2.7 6 GHz) 1 khz sine, 80% AM Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 khz; (0.15 80) MHz Ethernet ports 10 V, 80% AM, 1 khz; (0.15 80) MHz Earth port 10 V, 80% AM, 1 khz; (0.15 80) MHz Radiated RF emission CISPR 16-2-3 Enclosure Class B (30 2000 MHz) ANSI C63,4 Class B (30 2000 MHz) (FCC Part 15) Conducted RF emission CISPR 16-2-1 Power port Class B Ethernet ports Class B Dielectric strength EN 60950-1 Power port 1.5 kv ACrms, 50 Hz, 1 min to all other ports Fast Ethernet ports 1.5 kvacrms, 50 Hz, 1 min to all other ports Link to all other 1.5 kvrms, 50 Hz, 1 min ports Environmental Temperatures EN 60068-2-1 Operating 40 to +70 C ( 40 to +158 F) EN 60068-2-2 Storage and transport 50 to +85 C ( 58 to +185 F) Humidity EN 60068-2-30 Operating 5 to 95% relative humidity Storage and transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kpa Service life Operating 15 years MTBF 1,568,000 hours MIL-C217F2, GB, 25 C (+77 F) Vibration IEC 60068-2-64 Operating 2 m/s² (RMS) 5 150 Hz (random) Shock IEC 60068-2-27 Operating 10 g, 30 ms, 20 g, 11 ms Enclosure EN 60950-1 Zinc Fire enclosure Dimension W x H x D See "Dimensions" chapter for details With connectors Weight 1.4 kg Degree of protection EN 60529 Enclosure IP67 Cooling Convection 6641-2280 7

Description Made easy for extending Ethernet The Wolverine series consists of Ethernet extenders and bridges for propagating Ethernet traffic over existing cabling. The Ethernet link can be allowed to be extended over longer distances than possible with pure copper Ethernet and at data rates of up to 70 Mbit/s. The DDW-002-B1 makes it possible to reuse many types of pre-existing copper cables since it is based on power line communication (IEEE 1901). A network with the DDW- 002-B1 devices is capable of bridging high bandwidth Ethernet traffic over 2-wire cables, even when there are corroded connector.s The powerline communication standard is designed to establish a reliable communication link over both twisted pair and parallell cabling. This can lead to considerable financial savings when refurbishing a train with Ethernet communication, as existing train couplers can be reused without the need for a costly rebuild or even replacement. By simply installing a DDW-002-B1 on each side of the coupler, a bridge connecting the Ethernet networks on each side is created. The fact that no configuration is needed further contributes to the ease of use. Designed for harsh industrial environments The DDW-002-B1 has been thoroughly tested by certified labs to ensure its compliance with the standard for electronic equipment used on rolling stock, the EN 50155. For several characteristics, Westermo exceeds the requirements mandated by the standard. Furthermore, the design is based on Westermo s long experience within the rolling stock market, which brings benefits such as vi bration safe integrated connector threading, IP67 ingress protection with GORE-TEX membrane to prevent condensation water build-up and ultimately a high MTBF and long service life under the harshest conditions. Meeting the requirements for rolling stock, makes the DDW-002-B1 also very well suited for deployment in other applications with severe operating conditions and extreme environments. 8 6641-2280

Interface specifications DC, Power port Rated voltage 24 to 110 VDC Operating voltage 16.8 to 143 VDC (14.4 VDC for 100 ms, 154 VDC for 1 s) Rated current Rated frequency Inrush current, I²t Startup current* Polarity Redundant power input Isolation to Connection 350 ma @ 24 VDC and 90 ma @ 110 VDC DC 1 ma²s @ 24 V and 6 ma²s @ 110 V 535 ma @ 24 V 145 ma @ 110 V Reverse polarity protected Yes 1500 VAC rms to all other 4 pin male M12 A-coded connector, use Westermo cable 3146-1106 for 1.5 m 3146-1107 for 5 m Connector size M12, recommended cable area 0.5 mm² (minimum 0.25 mm²), cable dimensions depend on choice of M12 connector * External supply current capability for proper start-up X1 Ethernet ports Electrical specification Data rate Duplex Circuit type Transmission range Isolation to Connection Shielded cable Conductive housing Number of ports 1 IEEE std 802.3. 2005 Edition Auto-negotiation (10 Mbit/s or 100 Mbit/s) Auto-negotiation (full or half) X1: TNV-1 Up to 150 m with CAT5e cable or better 1500 VAC rms to all other ports 4-pin M12 D-code, auto MDI/MDI-X, use e g Westermo cable 3146-1100 M12-M12 1 m 3146-1101 M12-M12 5 m 3146-1103 RJ45-M12 1 m 3146-1104 RJ45-M12 5 m Not required, but recommended in severe electromagnetic environments Yes X2 Powerline interface Data rate Connection Transmission range Up to 70 Mbit/s 4-pin M12 B-code Up to 300 m (depending on cable characteristics) Electrical specification Supports communication over wires powered from 0 to 143 VDC. 6641-2280 9

Location of interface ports and LEDs Ethernet connection TX Powerline connection LED indicators 10/100 BASE/TX LINK Earth connection DC1 DC2 X1 X2 LINK STATUS ACTIVITY LINK MASTER ON POWER M12 Torque 0,6±0,1Nm / 0,45±0,1 lbft Power connection 10 6641-2280

Connector pinout Power connection Pin number Signal 2 1 No 1 +DC1 No 2 +DC2 No 3 -COM No 4 -COM 3 4 Pin number No 1 No 2 No 3 No 4 Housing Ethernet connection Signal TD+ RD+ TD RD Shield Auto MDI/MDI-X is used. The table shows signals in MDI mode. Pin number No 1 No 2 No 3 No 4 Powerline connection Signal PLC1 NC PLC2 NC 2 1 3 4 PLC1 and PLC2 are polarity free. 6641-2280 11

LED Indicators LED Status Description ON OFF Unit has no power GREEN All OK, no alarm condition DC1 OFF Unit has no power GREEN RED Power OK on DC1 Power failure on DC1 DC2 OFF Unit has no power GREEN RED X1 OFF No Link GREEN GREEN FLASH Power OK on DC2 Power failure on DC2 Link established Data traffic indication LINK STATUS OFF No PLC link established ON PLC link established ACTIVITY OFF No traffic on PLC link GREEN PLC traffic on PLC link LINK MASTER OFF Device is not link master (if PLC link established) ON Device is link master in the established PLC network 12 6641-2280

Wall mounting There are four 6 mm bore holes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M5 screws with 12 mm washer on a flat and stable surface. 10/100 BASE/TX LINK DC1 DC2 X1 X2 LINK STATUS ACTIVITY LINK MASTER ON POWER M12 Torque 0,6±0,1Nm / 0,45±0,1 lbft Connection of cables Recommended tightening torque for the M12 connectors: 0.6 Nm Note that unused connectors must be covered by a protective cap (delivered with the unit), tightened to the specified torque, in order to fulfill the specified ingress protection code. Removal Disconnect all cables and unscrew the unit from the wall. Time for replacement < 10 minutes. Cooling This unit relies on convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. EN 45545-2 mounting notes Two Viper units can be mounted together and as a single interior non-listed group in the sense of EN 45545-2 definitions. For multiple units the spacing requirements for interior non-listed groups must be met. 6641-2280 13

Getting Started This product is an unmanaged Ethernet extender designed to propagate Ethernet traffic over existing cabling. The DDW-002-B1 is easy to use and install. The units work in a pair over existing copper cabling infrastructure and automatically connect to each other when the remote device is sensed over the interconnecting lines. The installation procedure to get the application up and running is simple. Connect the cable (twisted pair or parallell cable) to X2 pin 1 and 3 (polarity independent). Connect Ethernet to the X1 port on the front of the DDW-002-B1. Connect power to the devices. The following settings are valid for the Ethernet interface: Ethernet Auto-negotiation enabled Auto MDI/MDI-X Auto-polarity enabled The DDW-002-B1 will automatically detect the possible data rate to the remote device (over the X2 - PLC interface ). The link performance can easily be measured after the powerline link is established. Different types of methods and tools can be used. One example of recommended software for throughput testing is Iperf. Please refer to Iperf user documentation for instructions of usage. Note! If the PLC link is not established or the established data rate is not suffcient for the application, the distance might be too long between the devices. The device is an unmanaged unit. If data throughput performance needs to be adjusted or if no powerline connection is established, check cabling between the devices. Configuration All necessary configurations are preconfigured from factory and no other changes in the settings can be done. 14 6641-2280

Dimensions Measurements are stated in millimeters. 56 100 6,5 36 54 65 164 174 6641-2280 15

Westermo SE-640 40 Stora Sundby, Sweden Tel +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com Sales Units Westermo Data Communications China sales.cn@westermo.com www.cn.westermo.com France infos@westermo.fr www.westermo.fr Germany info@westermo.de www.westermo.de North America info@westermo.us www.westermo.us Singapore sales@westermo.com.sg www.westermo.com Sweden info.sverige@westermo.se www.westermo.se United Kingdom sales@westermo.co.uk www.westermo.co.uk Other Offices For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code REV. B 6641-2280 2017-03 Westermo Teleindustri AB, Sweden