S-series H1 I/O Card with Integrated Power

Similar documents
S-series Foundation Fieldbus I/O

M-series Foundation Fieldbus I/O

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

S-series DeviceNet Interface Card

DeltaV SD Plus Controller

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

S-series Profibus DP Interface Card

S-series Sequence of Events Card

S-series Horizontal Carriers

S-series Serial Interface

M-series Profibus DP Series 2 Plus Interface Card

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

S-series DeviceNet Interface Card

S-series Sequence of Events Card

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

M-series Intrinsically Safe I/O

M-series MQ Controller

S-series Horizontal Carriers

S-series Mass Connection Solutions

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

M-series DC to DC Power Supply

M-series Traditional I/O

M-series Profibus DP Series 2 Plus Interface Card

M-series MX Controller

DeltaV Bulk Power Supplies

M-series DeltaV Controller Interface for RS3 I/O

DeltaV M-series I/O Subsystem Horizontal Carriers

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

M-series DeltaV Controller Interface for PROVOX I/O

DeltaV Bulk Power Supplies

S-series Electronic Marshalling for Migrations

S-series Virtual I/O Module 2

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

M-series Virtual I/O Module 2

M-series Virtual I/O Module 2

M-series MQ Controller

DeltaV VerticalPlus I/O Subsystem Carriers

DeltaV SIS Conditioning Components

S-Series DeltaV Controller Interface for PROVOX I/O

M-series I/O Subsystem Horizontal Carriers

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

S-series Serial Interface

S-series Virtual I/O Module 2

M-series Serial Interface Series 2

DeltaV SIS TMConditioning Components

DeltaV Ethernet I/O Card

Plant Messenger. Introduction. DeltaV Product Data Sheet. Delivers the information you want when and where you want it

M-series Serial Interface Series 2

DeltaV M-series Traditional I/O

DeltaV M-series Traditional I/O

Operator Station Software Suite

DeltaV M-series Traditional I/O

DeltaV Electronic Marshalling for Migrations

S-series Electronic Marshalling

History View Software Suite

S-series IS Electronic Marshalling

S-series Ethernet I/O Card

DeltaV Wireless I/O Card

DeltaV Controller Firewall

Batch Historian. Batch Historian. Introduction. DeltaV Product Data Sheet. Configuration-free, batch-based data collection

DeltaV S-series Traditional I/O

DeltaV Virtual IO Module Network Gateway

Free Standing DeltaV Double Door Cabinet

Product Data Sheet DeltaV 10.3 with AMS Device Manager Simplified Chinese Jan 2010 Page 1

S-series Electronic Marshalling

Emerson & Westinghouse

DeltaV Control Network Hardware

DeltaV Connect Solution for Bailey Systems

DeltaV Simulate. DeltaV Simulate. Introduction. DeltaV Product Data Sheet. Allows DeltaV configuration on a single PC or in a multi-node system.

Operator Station Software Suite

Fast Control Response Requirement

1756 ControlLogix Chassis Specifications

Free Standing DeltaV Single Door Cabinet

DeltaV IS Electronic Marshalling

Valve and Case Expansion Monitor Specifications

Wireless Field Data Backhaul

S-series IS Electronic Marshalling

DeltaV History Analysis

S-series Electronic Marshalling

DeltaV Four-Monitor Workstation

DeltaV Controller Firewall

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

A redundant DeltaV M-seriess controller protects your critical process from unexpected

DeltaV Electronic Marshalling

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Batch Analytics. Batch Analytics. Introduction. DeltaV Product Data Sheet. Predicts end-of-batch quality

1756 ControlLogix Chassis Specifications

DeltaV Display Transition Services for Honeywell Systems

Smart Commissioning. White Paper February 2018

Configuration Software Suite

OPC Data Access Server Redundancy

Professional Station Software Suite

ROConnect Interface. ROConnect Interface. Introduction. DeltaV Product Data Sheet. Native DeltaV system integration

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Faster module execution

Professional Station Software Suite

ControlWave PAC Redundant Systems

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

How Emerson s I/O on Demand Is Changing the Automation Infrastructure

Transcription:

January 2013 Page 1 S-series H1 I/O Card with Integrated Power Use DeltaV state-of-the-art for your process control system. Increase I/O capacity while reducing wiring Maximize smart device capabilities Redundant H1 cards provide increased availability Provides synchronized control Integrated segment power and diagnostics Segment Diagnostics Introduction FOUNDATION fieldbus I/O is a modular subsystem that communicates digitally with field devices, increases your input/output capacity, and gives you access to more information about your process than conventional I/O subsystems. DeltaV FOUNDATION fieldbus I/O greatly enhances device diagnostics that affect your control strategy and alerts operators to device malfunctions. FOUNDATION fieldbus I/O modular design offers flexibility during installation. It s designed to be installed in the field, close to your devices. Foundation fieldbus is equipped with function and field-wiring protection keys to ensure that the correct I/O card is always plugged into the corresponding terminal block. Modularity, protection keys, and increased input/output capacity make Foundation fieldbus I/O a smart choice for your process control system. www.deltav.com

January 2013 Page 2 Benefits Increase I/O capacity while reducing wiring. Use FOUNDATION fieldbus I/O instead of Classic I/O to increase the I/O density and quality of information of your field devices. Take advantage of FOUNDATION fieldbus digital communications to access additional information from your smart devices. Get more information over one wire with up to 16 Ff devices per H1 segment, and 2 segments per card for up to 32 devices per H1 card. Maximize smart device capabilities. Increase your quality and throughput by taking advantage of the added diagnostics of FOUNDATION fieldbus I/O devices. Field device status is updated continuously using FOUNDATION fieldbus I/O. For multi-variable devices, all process variables are available on the single fieldbus at the cost of a single Device Signal Tag. Redundant H1 cards provide increased availability. The DeltaV system offers redundant H1 interfaces. The two H1 interfaces are connected with a redundant terminal block to provide back-up link active schedule (LAS) capability that also maintains communication with the host system. Transfer to the standby card is automatic and requires no special configuration. Ongoing diagnostics ensure the standby H1 card is available on demand. This process requires no user interaction. Provides synchronized control. The DeltaV system allows DeltaV function blocks to run in the DeltaV FOUNDATION fieldbus H1 card. The assigned function blocks are scheduled in the fieldbus macro cycle, and supplement the available function blocks of the devices to provide powerful algorithms tightly coupled with the field device function blocks. Even if communication with the DeltaV controller is interrupted, the H1 assigned function blocks continue to execute within the segment macro cycle. Integrated segment power. The integrated power eliminates external 3rd party Fieldbus power supply products saving valuable cabinet installation footprint and wiring and associated FAT activities. Each isolated segment power supply provides up to 400 ma to the segment while short circuit protection is built in. Typical 24 VDC bulk power supplies connected through the 8-wide I/O carrier provide the power for the integrated power supply. Segment power diagnostics are integrated into the DeltaV Hardware alerts. Segment Diagnostics. The DeltaV S-series H1 interface with integrated power provides individual segment power diagnostic to complement existing hardware alerts and segment communication statistics. Possible faults detected now include power conditioner faults, like under voltage conditions and short circuit faults. Individual device and segment communication statistics provide additional diagnostic tools to isolate most installation issues. More advanced diagnostics of a segment can be performed as needed using an external tool connected to the segment via the terminal block. Product Description The FOUNDATION fieldbus S-series H1 I/O card with integrated power supports two Ff H1 segments, each supporting up to 16 Ff devices. Each segment runs an independent scheduler that controls the order of execution of each function block configured on the segment. DeltaV control modules provide a function block structure that defines the order of execution of each block on the segment, making it easy for each loop to be sequenced for efficient loop execution. Each field device commissioned on the segment consumes a single DST license and provides access to all its I/O data, including diagnostic parameters. This greatly increases the value of multi variable transmitters as well as their facilitating access to their diagnostic features. Signals referenced for each connected Foundation Fieldbus device will count at most 1 DST. The DST type counted will be the most valuable type used to reference a signal for each device. For example, a device with 1 AI signal reference and 1 AO signal reference will count as 1 AO DST The FOUNDATION fieldbus H1 interface is packaged in a medium form factor enclosure and installs on any I/O slot of the S-series horizontal carriers. The interface uses a separate terminal block to which the segment wires are connected. A single interface is used with the 1 wide terminal block in a simplex installation. Two H1 interfaces can be mounted in adjacent slots using the 2-wide redundant terminal block. The DeltaV controller recognizes the presence of redundancy and presents both cards as a single pair within the system. There is no additional user configuration required to set up the redundant H1 hosts. Segment power supplies are integrated into this H1 card, greatly simplifying installation design, reducing footprint and improving segment diagnostics.the terminal block includes a fixed segment terminator, eliminating external wiring to fieldbus power supplies and their terminators. Redundant H1 cards provide redundant power to the segments for increased availability. The S-series H1 with integrated power provides local LED indicators to assist in trouble shooting: 2 Yellow LED s: One per port Indicating the port is enabled and communicating with devices 2 Red LED s: One per port indicating to health of power suppliy as well as monitoring voltage or short circuit faults on the physical layer. Fault LED: Indicates internal fault with the H1 card

January 2013 Page 3 Power LED: Indicates available LocalBus power The Fieldbus I/O Card meets ISA G3 corrosion specifications by using superior electronic components and conformal coating. One of the most powerful features of FOUNDATION fieldbus devices is their diagnostic data. Using AMS Device Manager, you can access all of the necessary information to configure, commission, monitor, and troubleshoot all your FOUNDATION fieldbus smart devices. Improved device diagnostics can lead to increased product quality and minimize unplanned downtime. Improve the productivity and profitability of your process control system with FOUNDATION fieldbus. Fieldbus devices not manufactured by Emerson Process Management divisions are categorized as third-party devices. The DeltaV system provides third-party device support for devices that have successfully passed rigorous testing by Emerson Process Management and are registered by the Fieldbus Foundation. This allows you to benefit from the open fieldbus architecture when selecting field devices. Listed Fieldbus Devices on the DeltaV System. For current fieldbus device information, including device downloads and a list of 3rd-party devices that have been tested for interoperability with the DeltaV system, please refer to www.emersonprocess.com/deltav and click on Fieldbus Device Downloads. Redundant S-series H1 interface with integrated power. Hardware Specifications Operating temperature Storage temperature Relative humidity Environmental Specifications -40 to 70 C (-40 to 158 F) -40 to 85 C (-40 to 185 F) 5 to 95%, non-condensing Protection rating IP 20, NEMA 12 Airborne contaminants Shock Vibration ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

January 2013 Page 4 S-series H1 interface with integrated power dimensions S-series H1 with Integrated power Terminal Blocks

January 2013 Page 5 Hardware specifications Specifications for S-series H1 with integrated power, FOUNDATION Fieldbus Number of segments (ports) 2 Number of field devices: Number of Ff function blocks Voltage provided per segment 16 per port (dependent on device power consumption) 96 per card (64 fieldbus and 32 standard DeltaV) 28-30 VDC (short circuit protected) Current provided per segment 400 ma (short circuit protected) Isolation Each port is isolated from the system and from each other and factory tested to 1500 VDC. Nominal signal range (span) Fieldbus Foundation IEC 61158-2 LocalBus current per card (12 VDC nominal) 200 ma typical, 300 ma maximum 24 VDC bulk power 1.6 A Heat Dissipation Standards Airborne contaminants 7.2 W IEC 61158 data link layer ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating

January 2013 Page 6 Certifications The S-series H1 card with integrated power is available with the following Certifications: CE: - EMC- EN 61326-1:2006 - LVD- EN 61010-1:2001 ATEX CENELEC Zone 2 Hazardous Atmosphere Certificate Number: PF10CERRT1699 X 94/9/EG (ATEX) EN 60079-15:2005 EN 60079-0: 2009 The following certifications are in progress and not yet available FM Approval CSA 1010.1 Ordinary Locations Class 1 Division 2 Hazardous Locations Certificate Number: TBD Marine Certifications: ABS Certificate of Design Assessment Bureau Veritas Certificate DNV Marine Certificate Lloyds Register Other country specific certifications may also be available. Verify with your local Emerson sales office to confirm any certification requirements not listed here.

January 2013 Page 7 Ordering Information Description S-series H1 I/O Card with Integrated power and Terminal Block (includes 1 Interface Card and a simplex Terminal Block) Redundant S-series H1 I/O Card with Integrated power and Terminal Block (includes 2 Interface Cards and a redundant Terminal Block) SE4017P1 SE4037P1 Model Number Prerequisites Each fieldbus segment must be terminated at both ends. The H1 with integrated power terminal block includes a segment terminator for each segment. Additional terminators are purchased separately. Contact your local sales office for more information on complementary Fieldbus components. To locate a sales office near you, visit our website at: www.emersonprocess.com/deltav Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774 For large power, water, and wastewater applications contact Power and Water Solutions at: www.emersonprocess-powerwater.com Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East, Africa: 48.22.630.2443 North America, Latin America: +1 412.963.4000 2013 Emerson Process Management. All rights reserved. For Emerson Process Management trademarks and service marks, go to: http://www.emersonprocess.com/home/news/resources/marks.pdf. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice. www.deltav.com