DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

Similar documents
DATA SHEET. Advanced Power Meter, APM 380 & APM 305

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

for Energy and Power meters AEM and APM with Modbus interface

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

Installation and Operating Instructions

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

PQM - Power Quality Monitoring

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

COMTRAXX COM460IP. BMS-Ethernet-Gateway

BMS-Ethernet-Gateway COM460IP

Energy Management Energy Transducer Type ET112

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

MODEL: GR8-EM. Communication Adaptor GR8 Series

PLC PFC200 Controller PFC200 CS 2ETH RS

Leader in DIN rail measurement and communication instruments

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

DIRIS Digiware D and C Communication and control power interfaces

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

SH2WEB24. Central unit module. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

PHOENIX CONTACT Features

MID Energy Counters. Getting together is a beginning, staying together is a progress, working together is an achievement.

PQM - Power Quality Monitoring

Multifunction Transducer MT440

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Mains Monitoring Instruments 4

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

Measuring Devices and

SA2WEB24. Central unit module. Benefits. Description

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Siemens AG Measuring Devices and E-Counters. Configuration Manual 10/2010 SENTRON. Answers for infrastructure.

MODULAR CIRCUIT MONITORING SYSTEM

Mini Energy Web Server

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

with Backlight Graphic LCD Screen

Leader in DIN rail measurement and communication instruments

DATA SHEET Selectable AC transducer, TAS-321 DG

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

DATA SHEET Selectable AC transducer, TAS-331DG

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

E-STOP relays, safety gate monitors

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

Digital Multifunction Meters. Digital Multifunction Meters

CONTA-ELECTRONICS. Interface modules

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Web interface BACnet/IP

EngyVolt RV12 and RV15

IntesisBox Modbus Server KNX

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Datasheet - SRB 402EM-24V

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

IntesisBox Modbus Server Panasonic

EM270. Multi-channel power analyzer. Benefits. Description

THE NEXT TRANSDUCER GENERATION

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

MW/MVAR Transducer Specifications

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / Control / Monitoring Technique

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

USER MANUAL 2012 V1.1

Controls Division. Mounting. Mounting Terminal connections main circuit. Terminal connections control circuit. Insulation characteristics

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

RS485 MODBUS Module 6RO

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

ISOMETER isoev425 with coupling device AGH420

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

PT 3-PB-ST. Extract from the online catalog. Order No.:

Energy Management BUS Adapter Type VMU-B 01

Energy Management BUS Adapter Type VMU-B

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Transcription:

DATA SHEET For Energy and Power meters AEM and APM with Modbus interface Data logging Web Server interface Gateway - Modbus TCP/IP FTP DynDNS Up to 32 Energy and Power meters DEIF A/S Page 1 of 9 Document no.: 4921210139A

Table of contents 1. GENERAL INFORMATION... 3 APPLICATION... 3 OVERVIEW... 4 MODBUS TCP/IP AVAILABLE QUANTITIES... 4 2. TECHNICAL DATA... 6 3. OVERALL DIMENSIONS... 8 4. ORDERING INFORMATION... 9 DEIF A/S Page 2 of 9

1. General information Application The is to be connected to DEIF s energy and power meters, AEM and APM, by its Modbus interface, for the purpose of collecting the measured data from the instrument. Access them by a web browser through a TCP/IP network or by Modbus TCP/IP. For direct access to the logged data, it can be provided by the internal FTP server. It can be used in a local network (LAN) or a geographic network (WAN), which makes the product suitable for remote data collection through the Internet. The Modbus/TCP protocol provides the ability to access the energy and power meters to a remote client over the network. The also has DHCP and Dynamic DNS support. Application examples Sub-metering installations o Apartments o Campsites o Marinas Energy Management Systems Remote Monitoring Systems DEIF A/S Page 3 of 9

Overview Configuration For configuration, the offers a web-based configuration interface. All the parameters that can be modified by the user can be set simply connecting to the device through a normal web browser on a preset IP address. Such parameters are for instance the network parameters (IP address, subnet mask and gateway or DHCP), and general settings. Plug and play The is able to automatically recognise the instrument connected to Modbus interface. This is an advantage in terms of flexibility, because the same interface can be connected, for instance, to single-phase or three-phase energy and power meter. Storage of the measurements The measurements in transit from the instrument towards the TCP/IP network can be intercepted and stored inside the itself, until the saturation of the space of memory available. The saturation condition depends, of course, on sampling frequency of the measurements and on the number of measurements (related to the type of energy meter connected to the Modbus interface, for instance single-phase or three-phase). The data can be stored in the and subsequently downloaded to the user s PC, via web for a detailed examination. The data are stored in text format (CSV, Comma Separated Values). Date and time It has the capability to synchronise date and time using NTP (Network Time Protocol). Baud rate The pure speed of transmission is limited by the band capacity, which is 9600 baud on the IR interface. The is enabled to operate in 10/100 Mbps networks. FTP Server It is possible to access the logged data and real-time values by means of.csv files located in the internal storage. The FTP server provides the data, using an FTP client to retrieve them to an external location. DynDNS The use of Dynamic DNS allows the to be accessible to other nodes on the Internet while not owning a static address, such as using DHCP. An update client built into the LAN Server keeps the hostname up to date with its current IP address. SNMP Agent The has an internal SNMP protocol for device diagnostics. Support for Get and GetNext (and obviously GetResponse) messages. The set message is allowed, but only for writes with the default values (no change). Modbus TCP/IP available quantities Available quantities when connected with single-phase counters: Active energy imported, tariff 1 Active energy imported, tariff 2 Active energy exported, tariff 1 Active energy exported, tariff 2 Active Power Available quantities when connected with three-phase counters: Active energy imported, tariff 1, L1 Active energy imported, tariff 1, L2 Active energy imported, tariff 1, L3 Active energy imported, tariff 1, total Active energy imported, tariff 2, L1 DEIF A/S Page 4 of 9

Reactive energy imported, tariff 1 Reactive energy imported, tariff 2 Reactive energy exported, tariff 1 Reactive energy exported, tariff 2 Reactive Power Voltage Current Apparent Power Power Factor cos phi Frequency Tariff in use Status Active energy imported, tariff 2, L2 Active energy imported, tariff 2, L3 Active energy imported, tariff 2, total Active energy exported, tariff 1, L1 Active energy exported, tariff 1, L2 Active energy exported, tariff 1, L3 Active energy exported, tariff 1, total Active energy exported, tariff 2, L1 Active energy exported, tariff 2, L2 Active energy exported, tariff 2, L3 Active energy exported, tariff 2, total Active Power L1 Active Power L2 Active Power L3 Active Power total Reactive energy imported, tariff 1, L1 Reactive energy imported, tariff 1, L2 Reactive energy imported, tariff 1, L3 Reactive energy imported, tariff 1, total Reactive energy imported, tariff 2, L1 Reactive energy imported, tariff 2, L2 Reactive energy imported, tariff 2, L3 Reactive energy imported, tariff 2, total Reactive energy exported, tariff 1, L1 Reactive energy exported, tariff 1, L2 Reactive energy exported, tariff 1, L3 Reactive energy exported, tariff 1, total Reactive energy exported, tariff 2, L1 Reactive energy exported, tariff 2, L2 Reactive energy exported, tariff 2, L3 Reactive energy exported, tariff 2, total Reactive Power L1 Reactive Power L2 Reactive Power L3 Reactive Power total Voltage L1-N Voltage L2-N Voltage L3-N Voltage L1-L2 Voltage L2-L3 Voltage L3-L1 Current phase1 Current phase2 Current phase3 Apparent Power phase1 Apparent Power phase2 Apparent Power phase3 Apparent Power Total Power Factor cos phi phase1 Power Factor cos phi phase2 Power Factor cos phi phase3 Frequency Tariff in use Status DEIF A/S Page 5 of 9

2. Technical data Data in compliance with IEEE 802.3 AS, IEC 60950, EN 61000-6-2, EN 61000-4-2. General characteristics Housing Mounting Depth Data storage Auxiliary supply Auxiliary power rating Auxiliary voltage rating Un Auxiliary voltage range Frequency rating Frequency range Operating features System start LAN Gateway data addressing Data transfer speed User interface for setup and management Required software tool Suitable for both single-phase and three-phase meters LAN interface HW interface SW protocol Application level protocols Instruments bus interface HW interface Cable Cable length Installation type Directly connected instruments SW protocol Modbus version Safety acc. to IEC 60950 Degree pollution Overvoltage category Working voltage Material group Clearance Creepage distance Test voltage DIN 43880 EN 60715 Flash memory LAN limited Internet browser RS 485 Terminals Conductor cross section Conductor capacitance Impedance RS 485 DIN 35 mm mm years VA V(AC) V(AC) Hz Hz Mbit/s No. mm² 4 module DIN rail 70 10 10 230 (0.80 to 1.20)x Un 50 45 65 Automatic at connection of auxiliary power by means of IP address 100 Web browser yes 50 Hz 1 min pf/m Ω m No. V mm mm kv RJ 45 connector TCP/IP HTTP-Modbus/TCP- FTP-SNTP- DHCP-DNS- DynDNS-SNMP 3 (±,cable shield) STP (shielded twisted pair) 2 x 0.2 or 2 x 24 AWG 50 100 100 serial 32 Modbus RTU 2 II 300 II 4.0 4.5 4.0 DEIF A/S Page 6 of 9

Housing material flame resistance Connection terminals Cage type Terminal capacity UL 94 class V0 Screw head Z± Solid wire min.(max) Stranded wire with sleeve min.(max) POZIDRIV mm² mm² PZ1 0.75(6) 0.75(6) Environmental conditions Operating temperature Relative humidity Limit temperature of transportation and storage Vibrations(sinusoidal) Protection class Degree of protection 5 Hz to 10 Hz constant displacement Acc. to IEC 60950 Housing when mounted C % C mm 0...+55 80-20...+70 ± 0.25 II IP50 (IP20) DEIF A/S Page 7 of 9

3. Unit dimensions DEIF A/S Page 8 of 9

4. Ordering information Order details Data Logger, Gateway and Web Interface - up to 32 energy and power meters. Modbus RTU, Modbus TCP/IP, DynDNS, FTP. Aux. supply: 230V AC/50 Hz DEIF no. 1217030005 EAN no. 5703727113477 Energy Meters Order details AEM 380 Three-phase energy meter, 80 A, 2S0, 2 tariffs, MID-approved. Aux. supply: 230V AC/ 50 Hz DEIF no. 1217010002 EAN no. 5703727110063 AEM 305 Three-phase energy meter, CT../5 A, 2S0, 2 tariffs, MID-approved. Aux. supply: 230V AC/ 50 Hz DEIF no. 1217010004 EAN no. 5703727110070 AEM 180 Single-phase energy meter, 80 A, 2 tariffs, 2S0, MID-approved. Aux. supply: 230V AC/ 50 Hz DEIF no. 1217000002 EAN no. 5703727110056 Power Meters APM 380 APM 305 Interface Modbus Interface Order details Three-phase power meter, 80 A, 2S0. Aux. supply: 230V AC/50 Hz DEIF no. 1217020002 EAN no. 5703727110094 Three-phase power meter, CT../5 A, 2S0. Aux. supply: 230V AC/50 Hz DEIF no. 1217020001 EAN no. 5703727110087 Order details Modbus - RTU/ASCII for energy and power communication. Aux. supply: 230V AC/50 Hz DEIF no. 1217030001 EAN no. 5703727110100 DEIF A/S reserves the right to change any of the above. DEIF A/S Page 9 of 9