Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling. 360b/01

Similar documents
Lux Intelligent Emergency Light Testing System. Lx Features

MIOU. Multi Input/ Output Unit. User Manual. Issue 05 Jul Product Manuals/Man-1060 MIOU

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

AC5160 SiPass integrated controller kit

SicuroLED-G - advantages

FC726 Fire control panel

Sigma XT Ancillary Board (K588)

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

with Backlight Graphic LCD Screen

SPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM

FC2080 Fire control panel (modular)

FC724 Fire control panel

Gladiator Lift Services Ltd OPTIO MRL Controller Specification

Gas Controller System DGC-06

Data Manager Installation Guide

FC722 Fire control panel

Product Data Sheet. Hochiki 8 Way I/O Card. Features

FC726 Fire control panel

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

Installing Sentor. Hardware Installation

aerl PRODUCT DATASHEET MAXIMIZER TM RANGE PRODUCT OVERVIEW COOLMAX SR - Wall Mount Australian Energy Research Labs AER G2 v5 1 February 2016

B60 Domestic Voltage Optimisation Unit

Accessories for Vessels

VIDI System Controller

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Product Brochure PMA KS Multi-function Controller.

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved.

Performance and Efficiency

4 balanced inputs 1 relay output

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring.

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

TALON Network Manager- 2 & 6 Express

WaterCress Portfolio

Electrical Demand Specification (Reference SOP: )

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

- NLS NAVIGATION LIGHT CONTROL

SNAP, CLICK, DONE. Getting Started Guide

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Technical System Catalogue CMC III Monitoring System

Smart Monitoring System compact, secure, efficient

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

DC POWER SUPPLIES DNX 110/220 V

Plasmatronics 9/07/2009 Plasmatronics_Brief.product.summary_Ver.1.4.doc Slide 1

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

Installation Manual for D24XX Series of 24V Switched Mode Power Supplies

EnCell Battery Cell Monitor

Fle F xs le y xs s y C s on C tr on oller

Industrial Safety Systems

VIPER MANUAL TM0019. TM0019 Page 1 of 48 Issue 2.01

POWERING TECHNOLOGY. Reliably powering your business. Solving your power needs. DC POWER SYSTEMS

B60 Domestic Voltage Optimisation Unit. Installation Manual

Installation Manual for D244X Series 24-volt Power Supplies

Controller 3000, dependent on reader technology and site configuration. All I/O functionality is provided on the Controller 3000.

EXOcompact. Third generation freely programmable controllers

Built-in features Built-in simplicity Built for fans & pumps

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

System Installation guide

Control4 DIN Rail Lighting

DATA SHEET Advanced Graphical Interface, AGI 300 series

MP7. Uninterruptible Power Supply

Industrial Control SE-607

Engine & Genset Controls Z, page 1 of 12

CMM366-3G CLOUD MONITORING COMMUNICATION MODULE USER MANUAL

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

ABOUT US. There have been more than lift control systems and more than 1500 complete elevators installed worldwide since 1997.

MULTICHANNEL DATA RECORDERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

Rako RAK4-R Instruction Manual

AC5160 Controller. Fire & Security Products. SiPass integrated

Power supply Quick look-up guide

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Datasheet - AZ 15 ZVRK

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

SECTION ELECTRICAL CONTROL DEVICES

CCP CABINET PRODUCT RANGE

Chassis Power Supplies

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

DATASHEET PRELIMINARY MONITORS Fire load and smoke-optimized. DATA DISPLAY GROUP

CLA-VAL Control Panel

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

Power supply module, bus connection module

IT-467-*-BT 22" (1680 x 1050)

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Multi-channel measurement technology to measure CO, NO & Visibility in one compact sensor

Lighting control for commercial buildings

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

New Product Release. Integrated Intelligent Power Distribution.

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Neon pr. ph/ ORP measurement. Applications. Description

DATA SHEET Advanced Graphical Interface, AGI 100 series

GAMATRONIC, A SolarEdge Division.

Transcription:

Electronics Ltd Presenting Power, Intelligence... with a sense of feeling 360b/01

Plug in slots K772 16 Channel I/O Board K791 8 Way Relay Board K792 8 Way Conventional Zone Board K793 4 Way Sounder Board 24V DC Taktis Vision Configurable Fire Alarm Repeater Cloud Servers GSM IP DialUp Media Gateway IO Cards RS485 bus Taktis Virtual Resource VR Access Access data from all your systems VR Vault Secure document vault VR Service Complete service management utility with automated data transfer VR Print Eliminates need for panel mounted printers 2 8 Loop Analogue High Integrity Configurable Network 2 8 Loop Analogue The Taktis system is compatible with Apollo, Argus Vega and Hochiki protocols. Panels of any of the above protocols can be used on the same network. Up to 128 Panels/ Repeaters can be added to the network. 2 8 Loop Analogue 2 16 Loop Analogue Taktis Vision Configurable Fire Alarm Repeater 24V DC I/O I/O Loop 3 Loop 8 Loop 1 Loop 2 (if fitted) Each bank of 2 loops can be different protocols. Each loop is capable of hosting up to: 126 devices (Apollo) or 240 devices (Argus Vega) or 127 devices (Hochiki). Loop 1 Loop 2 Each loop is capable of hosting up to: 126 devices (Apollo) or 240 devices (Argus Vega) or 127 devices (Hochiki). Loop 3 Loop 8 (if fitted) Each bank of 2 loops can be different protocols. Power, Intelligence... with a sense of feeling

Overview The Taktis product range combines the very latest hardware and software to produce a control and indication system, which is powerful and sophisticated, yet simple to use and understand. The large graphical touch screen provides a clear, uncluttered and intuitive interface so the end user requires minimal training. Initially configured as a fire detection and alarm system, the flexibility of the Taktis platform is such that it can be reconfigured to realise many other control and indication applications, with direct integration into intelligent buildings. Available in 4 slot and 8 slot variants, with each slot supporting a 2 loop detection card, the Taktis fire control panel ranges from 2 to 16 detection loops. The generous quantity of sounder circuits, relays and inputs provided as standard can be further increased by the addition of one or mode Taktis I/O plug in expansion cards. Taktis Vision panels can be connected to the Taktis network to provide a fully functional repeater in a compact enclosure. Not only do the products and services offered under the Taktis brand provide solutions to the most technically challenging applications in life safety, Taktis will deliver added value through ease of use, displaying clear information ensuring that when an event occurs appropriate action is taken swiftly. The Taktis Media Gateway provides a means for the system to transmit real information back to our dedicated server network. This data is then accessed using the Taktis Virtual Resource (VR) software suite via a web browser. The remote management features offered by Virtual Resource can result in reduced fault calls, improved technical support, efficient and proven maintenance, reduction of unwanted alarms, a full audit trail and improved overall service to the end user. The Taktis Network Card allows networking of up to 128 panels and repeaters meaning that Taktis can provide reassurance to all building owners/ operators whether responsible for a small system or a large complex. Features Certified to EN542 & EN544 2 to 8 loop or 2 to 16 loop versions Multiple protocols supported on a single panel (in banks of two loops) 500 milliamp loop current 4 programmable sounder circuits each rated at 2.5 Amps 5.25 Amp or 10.25 Amp power supply options 3 programmable inputs 5 programmable relay outputs Up to 512 programmable I/O via optional plug in and serially connected expansion cards Hard wired fire and fault routing inputs and outputs 2 ancillary serial ports Modbus, LonWorks and BACnet interface options Modular electronics Over 4000 sub address points per panel NOT and TIME as well as COINCIDENCE, OR and AND operators in cause and effects Option to invert inputs and outputs Powerful, standard configuration templates Network up to 128 panels Configurable via USB port to PC or memory stick Expandable memory via standard SD card Optional Media Gateway communications card At time of printing some features may not be fully implemented.

Taktis Display Connectivity The Media Gateway card plugs into one of the panel slots and provides connectivity to our servers using IP, GSM or Dial Up connectivity The Media Gateway card is also used to meet integration application requirements. Taktis utilises a full colour, 7 800x480 touch screen graphical display to provide a clear, simple and intuitive user interface. 80 character zone location and 80 character device messages allow a clear, concise description of each detection device location to be configured. Resistive touch screen technology permits control functions to be available, even when wearing protective gloves. User Access Access to the Taktis menu and control functions is provided by a unique 6 digit pass code or by the optional enable control key switch. Up to 64 individual login accounts can be configured, with different profiles and access permissions. Powerful, Network wide Cause & Effects Taktis cause and effect capacity supports 5000 cause and effects comprising up to 40,000 inputs/outputs across the network. The introduction of Groups in Taktis allows rationalisation and simplification of the system configuration. Support for up to 5000 groups and up to 50,000 devices is provided. Taktis Display Function Buttons Up to 24 customer specific function buttons may be configured to provide control, disablement and engineering functions. The functions buttons can be configured to be either available or hidden for each log in profile. Zone Indicators Up to 144 zone indicators or 48 zone indicators plus panel printer are available. Taktis supports up to 2000 detection zones and zone indicators.

Power Supply Options Taktis is available with two power supply options, each available in 230V or 115V mains voltages 5.25A (supports up to 26Ah batteries) 10.25A (supports up to 45Ah batteries) Note: The standard depth enclosure (150mm deep) houses up to 26Ah batteries and the deep enclosure (190mm deep) houses up to 45Ah batteries. Backlight Control The built in light sensor allows the display backlight can be configured to follow the ambient light levels or automatically dim after a period of inactivity. Event Log A 10,000 entry event log records all system activity to 1 second resolution. The log is held in secure memory and is retained when power is removed from Taktis. Powerful filtering allows the log to be sorted by event type, between dates, by zone, by panel and by address. Using the Loop Explorer 2 configuration program, the event log can be downloaded and stored as a comma separated values (csv) format Printer Option A 40 character front loading thermal printer prints all events as they occur. The printer can also be used to print all/selected event log entries. Expansion Options Taktis I/O cards can be fitted in spare slots within the panel. The family includes 8 way conventional detection board 4 way sounder output board 8 way volt free relay contact board 16 channel programmable I/O board

Technical info 28 loop (4 slot) Enclosure Size Construction Cable entry Battery Capacity 420mm (W) x 590mm (H) x 153mm (D) (Standard) 420mm (W) x 590mm (H) x 203mm (D) (Deep) 1.5mm mild sheet steel 28 knockouts top, 19 knockouts back, 1 knockout each side, 2 knockouts bottom (Standard) 38 knockouts top, 19 knockouts back, 1 knockout each side, 2 knockouts bottom (Deep) Up to 26Ah Standard, Up to 45Ah Deep Size Construction Cable entry Battery Capacity Finish Colour Lid & Box Colour Controls Plate Power supply voltage Power supply rating at 24V DC Display 216 loop (8 slot) Enclosure Printer Zone LED indicators Software zones Software groups Event log Detection loops Detection loop current Sounder circuits Auxiliary 24V supply 1 Auxiliary 24V supply 2 Default relays Programmable inputs Auxiliary Serial port A Auxiliary Serial port B Ancillary I/O board serial port Fire Routing (Ifam) serial port USB host port USB device port Fire routing output Fire routing input Fault routing output Fault routing input Extinguisher output Extinguisher input Extinguisher fault input All Models 540mm (W) x 720mm (H) x 160mm (D) (Standard) 540mm (W) x 720mm (H) x 212mm (D) (Deep) 1.5mm mild sheet steel 38 knockouts top, 25 knockouts back, 2 knockouts each side, 2 knockouts bottom (Standard) 50 knockouts top, 25 knockouts back, 2 knockouts each side, 2 knockouts bottom (Deep) Up to 26Ah Standard, Up to 45Ah Deep Epoxy powder coated BS 00 A 05 fine texture RAL7016 230V AC or 115V AC 5.25A (charges up to 26Ah) or 10.25A (charges up to 45Ah) Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming 40 column, front loading thermal (optional) Up to 3 banks of 48 (144) as standard 2000 5000 10,000 events, 1 second resolution. Filterable and printable. 2 to 16 added 2 at a time (K758 dual loop cards) 500 milliamps each 4 each rated at 2.5A, 24V DC, programmable 24V DC fused at 500 milliamps 24V DC fused at 500 milliamps Fault, Fire, Alarm, Programmable 1 and Programmable 2 (all reprogrammable) 3, activated by volt free contacts RS232 programmable RS232 programmable RS485 programmable RS485 programmable USB type A USB type B Kentec Electronics Ltd Units 2527 Fawkes Avenue Questor Dartford Kent DA1 1JQ England T +44 (0)1322 222121 F +44 (0)1322 291794 E sales@kentec.co.uk W www.kentec.co.uk