HD2107.1, HD2107.2, HD2127.1, HD2127.2

Similar documents
HD TP472I.0 1/3 DIN Thin Film. TP473P.0 1/3 DIN Thin Film. TP474C.0 1/3 DIN Thin Film. TP475A.0 1/3 DIN Thin Film. TP49A.0 Class A Thin Film

HD Common features. Common features. TP49AP: Penetration probe, Pt100sensor. Stem Ø 2.7mm, length 150mm. Cable 2 meters long.

HD32.7 HD HD [ GB ] 8-input Data Logger for Pt100 probes with SICRAM module

Hand-held thermometer Model CTH7000

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Phone: Fax: For calls outside the US please call:

English. Operating manual. Thermocouple thermometers HD HD HD HD Keep for future reference.

Supplied with. Calibration certificate. HD 200 Hygrometer

Hand-held thermometer Model CTH7000

Precision digital measuring device PHYSICS 51

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Hand-Held Thermometer Model CTH 6200

Multi-functional precision thermometer CTR3000

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool

Thermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

PHYSICS Digital Measuring Devices

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Specification for temperature sensor calibration setup

Hand-held thermometer Model CTH6200

Supplied with. Calibration certificate. TM 200 Thermometer

1523/1524 Reference Thermometers

English. Operating manual. Manometers / thermometers HD HD HD HD HD HD HD2114B.0 HD2114B.2.

C.A 1821 / C.A 1822 / C.A 1823

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

HD HD ENGLISH

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

HD 9609 INSTRUCTIONS MANUAL

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

HD33[L]MT.GSM HD33[L]MT.3G GSM/3G data loggers for weather stations

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Portable Multi-Function Calibrator Model CEP6000

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

C.A 1821 / C.A 1822 / C.A 1823

Field Metrology Wells

UNIVERSAL TEMPERATURE TRANSMITTER

DPL4000 Portable Low Range Dew Point Analyzer

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Precision thermometer Model CTR5000

HD32.7 RTD DATALOGGER ENGLISH

1450 First Ave. Page 1 of 11 Chippewa Falls, WI (800) or (715) Fax: (715)

PI 500 Hand-held instrument for industry

Supplied with. Calibration certificate. TM 200 Thermometer

Thermocouple temperature probes with sensitive element as per IEC 584-1, 2 and 3 standard

Hand-held thermometer Model CTH6200

USB-5100 Series Multi-Channel Data Loggers

HD B. [ GB ] Precision Barometer

DC resistance thermometry bridge Model CTR6000

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

DICKSON FH320/325 & FT300/325 DICKSON. Temperature/Humidity Recorder. Specifications. Applications & Product. Product. Contents: Getting Started

Field Metrology Wells

HD 9817T1R HD 9817T2R HD 9817T3R HD 9817TVS

DMT345 and DMT346 Dewpoint Transmitters

MMT330 Series Moisture and Temperature Transmitters for Oil

HD THERMOCOUPLE THERMOMETER ENGLISH

HD 2013 HD 2013-D AA-26 AA-27

English. Operating manual. Hygrometers / thermometers HD HD Keep for future reference. Companies / Brands of GHM

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

1. Presentation. 1.1 Instrument description. 1.2 Keys description

Precision humidity/temperature control/sensing

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

HygroLog HL20 and HL21 Data Logger. User Guide

Measurement data monitoring system

1. Presentation. 1.1 Instrument description. 1.2 Keys description

Precision Hand-held Thermometer

HI HI N HI HI

WiFi data logger system

English. Operating manual. Multiparameter portable instrument HD Keep for future reference. Companies / Brands of GHM

Ultra-Accurate Measurement for Temperature and Voltage

Precision thermometer Model CTR2000

L200 User Manual. Operating Instructions for L200-TC & L200-PT Temperature Monitor. RoHS compliant

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

of the dew point curve/ the switching behavior of the dryer over a longer period of time.

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

Advanced Signal Calibrator ASC-400. User friendly and innovative

Battery operated recorders. Built-in battery operated GSM modem Text message alerts Data collecting to Comet database software and Comet cloud

Precision Thermometry Bridges

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Class 220 KISTOCK. KT 220, KH 220 and KTT 220

PCD DIGITAL Differential pressure probe

HMT330 Series Humidity and Temperature Transmitters

HygroClip DIGITAL Humidity and temperature probe

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

Measurement data monitoring system

TR-7 Series. Network / USB Data Loggers TR-7wf/nw Series Infrared / USB Data Loggers. TR-7Ui Series

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

HygroLog HL20 and HL21 Data Logger. User Guide

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

1450 First Ave. Page 1 of 8 Chippewa Falls, WI (800) or (715) Fax: (715)

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Transcription:

HD2107.1 HD2107.2 HD2127.1 HD2127.2 HD2107.1, HD2107.2, HD2127.1, HD2127.2 TC input: 1 1 2 2 Storage capacity PC interface ---- 76000 samples ---- RS232C RS232C + USB2.0 RS232C 38000 couples of temperatures RS232C + USB2.0 Data logger NO YES NO YES A-B function NO NO YES YES HD2107.1- HD2107.2 - HD2127.1 - HD2127.2 Pt100 AND Pt1000 SENSORS THERMOMETERS HD2107.1 and HD2107.2 are portable instruments equipped with large LCD display fitted with one input. HD2127.1 and HD2127.2 are instruments fitted with two inputs. They measure temperature by means of immersion, penetration, contact or air probes. Their sensor can be Pt100 with 3 or 4 wires, Pt1000 with 2 wires. They have centesimal resolution in the range ± 199.99 C, decimal in the rest of the range. Probes are equipped with an automatic recognition module: factory calibration data are stored inside. The instruments HD2107.2 and HD2127.2 are data logger; they store up to 80.000 samples which can be transferred into a PC connected to the serial ports RS232C and USB 2.0 or into portable printer. It is possible to configure the storage interval, the printing and the baud rate by the menu. Functions Max, Min and Avg calculate maximum, minimum and average values. Further functions are: REL relative measure, HOLD and automatic switching-off system (excludable). Instruments have IP66 protection degree. 8 Technical specifications Measurement of temperature Pt100 measurement range -200 +650 C Pt1000 measurement range -200 +650 C Resolution 0.01 C in the range ±199.99 C 0.1 C in the remaining range Instrument Accuracy ±0.01 C Drift after 1 year 0.1 C/year Unit of measurement C - F - K Measured values storage model HD2107.2 Type Quantity Storage interval can be selected among 2000 pages containing 40 samples each Total of 80000 samples 1,5,10,15,30 s 1,2,5,10,15,20,30 min.; 1 hour Measured values storage model HD2127.2 Type 2000 pages containing 16 pairs of samples each Quantity Total of 32000 samples (channel A + channel B) Storage interval can be selected among Security of stored data Power Supply Batteries Autonomy Current consumption with instrument off Main 1,5,10,15,30 s, 1,2,5,10,15,20,30 min.; 1 hour Unlimited, independent of battery charge conditions 4 Batteries 1.5V type AA 200 hours with 1800mAh alkaline batteries 20μA 12Vdc / 1000mA Output mains adapter Serial interface RS232C Type RS232C galvanically isolated Baud rate can be set from 1200 to 38400 baud Data bit 8 Parity None Stop bit 1 Flow Control Xon/Xoff Serial cable length Max 15m Print interval Immediate or selectable among: 1,5,10,15,30 s; 1,2,5,10,15,20,30 min.; 1 hour USB interface - model HD2107.2, HD2127.2 Type 1.1-2.0 galvanically isolated Connections Input for the probes 8-pole male DIN45326 connector RS232C serial interface 8-pole MiniDin connector USB interface Type B MiniUSB connector Mains adapter 2-pole connector (positive at centre) Operating conditions Operating Temperature -5...50 C Storage temperature -25 65 C Working relative humidity 0 90%RH, no condensation

Protection degree General characteristics Dimensions (Length x Width x Height) Weight Materials Display Time Date and time Accuracy IP66 185x90x40mm 470g (complete with batteries) ABS, rubber 2 rows 4½ digits plus symbols Visible area: 52x42mm In real time 1min/month max drift PC, is necessary the USB/serial converter C.206. The converter is supplied with its own drivers which must be installed before the connection of the converter to the PC (see details in the Cd-Rom supplied with the converter). C The port with the minidin connector is a serial port type RS232C. The serial port RS232C of a PC or the printer HD40.1 can be connected by the cable HD2110CSNM. ORDERING CODES HD2107.1: The kit consists of instrument HD2107.1, 4 per 1.5V alkaline batteries, instruction manual, case and Deltalog9 software downloadable from Delta OHM website. Probes and cables have to be ordered separately. HD2107.2: The kit consists of instrument HD2107.2 data logger, 4 per 1.5V alkaline batteries, instruction manual, CP23 USB cable, case and Deltalog9 software downloadable from Delta OHM website. Probes have to be ordered separately. HD2127.1: The kit consists of instrument HD2127.1, 4 per 1.5V alkaline batteries, instruction manual, case and Deltalog9 software downloadable from Delta OHM website. Probes and cables have to be ordered separately. HD2127.2: The kit consists of instrument HD2127.2 data logger, 4 per 1.5V alkaline batteries, instruction manual, CP23 USB cable, case and Deltalog9 software downloadable from Delta OHM website. Probes have to be ordered separately. HD2110CSNM: 8-pole connection cable MiniDin - Sub D 9-pole female for RS232C. C.206: Cable for instruments of the series HD21...1 to connect to USB input of PC. SWD10: Stabilized 230Vac/12Vdc-1000mA mains adapter. HD40.1: Upon request, portable, serial input, 24 column thermal printer, 58mm paper width. Use cable HD2110CSNM (option). For all Pt100 and Pt1000 probes, see from pag.30 onwards. A The portable data loggers HD2107.2 HD2127.2 are equipped with HID (Human Interface device) type USB port with mini USB connector. For the connection to a PC with the CP23 cable it is not necessary to load any USB driver. B For the connection of the models HD21071 HD2127.1 to the USB port of a HD2107 HD2127 9

TEMPERATURE PROBES RESISTANCE THERMOMETERS Delta OHM offers a wide choice of Platinum resistance thermometers with resistance equal to 100 Ω at 0 C and temperature coefficient α as defined by the IEC 60751 standard: Pt100, R0=100 Ω, α= 3.851 10-3 C -1. For particular applications, probes with Pt1000 sensor or with a thermistor sensor are available. The response time τ 0.63 indicated for each probe is the response time of the sensor to a temperature variation, with a variation of the measured signal corresponding to the 63% of the total variation. The response times are referred: in water at 100 C for immersion probes; to the contact with a metal surface at 200 C for surface probes; to an air temperature of 100 C for air probes. The IEC 60751:2008 standard defines the tolerance classes of the resistance thermometers as summarized in the following table: Temperature Range Tolerance class WIRE WOUND sensor THIN FILM sensor Tolerance [ C] classe AA (1/3 DIN) from C to 250 C from 0 C to 150 C ±(0.1+0.0017 t ) classe A from -100 C to 450 C from -30 C to 300 C ±(0.15+0.002 t ) classe B from -196 C to 600 C from C to 500 C ±(0.3+0.005 t ) classe C from -196 C to 600 C from C to 600 C ±(0.6+0.01 t ) On request, the probes can be assembled with a compatible connector chosen from TP471 and TP47. The TP471 connector developed by Delta OHM contains an electronic module (SICRAM) that allows the probe error to be adjusted. During the Quality Control, the probes provided with this module are individually checked in our laboratories, linearizing the characteristic and allowing more stringent accuracy over the entire working range. The following graph shows the Delta OHM SICRAM module probe TP472I typical error values obtained from the calibrations performed in our ISO17025 calibration laboratory. The graph highlights the effectiveness of the linearization performed on the probes. 1,0 Comparison between the classes defined in IEC 60751 standard and the typical error of the Delta OHM TP472I SICRAM probe 0,8 0,6 0,4 Tolerance [ C] 0,2 0,0-0,2 TP472I probe typical error -0,4-0,6-0,8-1,0-200 -100 0 100 200 300 400 500 Temperature [ C] 30

Tolerance as a function of temperature. The temperature range refers to the platinum wire wound probes. Temperature [ C] Tolerance [ C] -196-100 0 100 250 300 350 450 500 600 class AA --- ± 0.27 ± 0.19 ± 0.10 ± 0.27 ± 0.53 ± 0.61 ± 0.70 --- --- --- class A --- ± 0.35 ± 0.25 ± 0.15 ± 0.35 ± 0.65 ± 0.75 ± 0.85 ± 1.05 --- --- class B ± 1.28 ± 0.80 ± 0.55 ± 0.30 ± 0.80 ± 1.55 ± 1.80 ± 2.05 ± 2.55 ± 2.80 ± 3.30 class C ± 2.56 ± 1.60 ± 1.10 ± 0.60 ± 1.60 ± 3.10 ± 3.60 ± 4.10 ± 5.10 ± 5.60 ± 6.60 accuracy TP472I ± 0.30 ± 0.30 ± 0.20 ± 0.10 ± 0.20 ± 0.20 ± 0.30 ± 0.30 ± 0.30 ± 0.30 --- By means of the calibration, the purchased instrument can be metrologically characterized, determining the systematic error of the thermometer and ensuring at the same time the traceability to international standards. Delta OHM Laboratories are able to provide this service by issuing calibration reports according to ISO 9001 or ACCREDIA LAT certificates in compliance with ISO/IEC 17025 standard, recognized internationally through ILAC MRA agreements. 31

Pt100 PROBES WITH TP471 SICRAM MODULE CODE T ( C) ACCURACY USE τ 0.63 DIMENSIONS TP472I -196 +500 300 Ø 3 TP472I.O +300 230 Ø 3 TP473P.I +400 150 Ø 4 TP473P.O +300 TP474C.O +300 230 Ø 5 TP475A.O +250 12s 230 Ø 4 TP472I.5 +400 500 Ø 6 TP472I.10 +400 1000 Ø 6 TP49A.I -70 +250 3, TP49AC.I -70 +250 ±0.3 C (t < C; t > 250 C 5, TP49AP.I -70 +250 4s TP87.O +200 70 Ø 3 32

Pt100 PROBES WITH TP471 SICRAM MODULE CODE T ( C) ACCURACY USE τ 0.63 DIMENSIONS TP878.O TP878.1.O +85 +85 Contact probe for solar panels, with SICRAM module. Cable L = 2 m Contact probe for solar panels, with SICRAM module. Cable L = 5 m TP879.O -20 +120 Penetration probe for compost, with SICRAM module. Cable L = 5 m Mignon head, cable length = 2m TP880/300.I +450 Mignon head, cable length = 2m TP880/600.I +450 TP35.5AF.5S -110 +180 Cable L = 5 m. Shield in Inox + PTFE TP875.I Globe-thermometer probe for measurement of radiant heat with 0150mm. Accuracy according to ISO 7243 ISO 7726. Pt100 sensor, 4-wire cable L=2 m. Supplied with SICRAM module. TP876.I -30 +120 15' Globe-thermometer probe for measurement of radiant heat with 0 50mm. Accuracy according to ISO 7243 ISO 7726. Pt100 sensor, 4-wire cable L=2 m. Supplied with SICRAM module. 33

Pt100/Pt1000 PROBES WITH TP47 CONNECTOR WITHOUT SICRAM MODULE CODE T ( C) CLASS USE τ 0.63 DIMENSIONS TP47.100.O TP47.1000.O (Pt1000) +250 TP87.100.O +250 TP87.1000.O (Pt1000) Pt100 PROBES ENDING WITH FREE WIRES TP875.1.I TP876.1.I -30 +120 1 Globe-thermometer probe for measurement of radiant heat with 0150mm. Accuracy according to ISO 7243 ISO 7726. Pt100 sensor, 4-wire cable L=2 m. Globe-thermometer probe for measurement of radiant heat with 050mm. Accuracy according to ISO 7243 - ISO 7726. Pt100 sensor, 4-wire cable L=2 m. TP878.1SS.O +85 Contact probe for solar panels 4-wire cable L = 5 m TP879.1.O -20 +120 Penetration probe for compost 4-wire cable L = 5 m TP32MT.1P.I +100 40s TP32MT.1P.2 +250 40s TP32MT.2.I +100 TP35.5AF.5-110 +180 Cable L = 5 m. Shield in Inox + PTFE 34

TEMPERATURE PROBES FOR INDUSTRIAL USE CODE T ( C) CLASS USE τ 0.63 DIMENSIONS HD882/EK (KTY81) +150 Not applicable HD882/ E/100 +300 HD882/GK (KTY81) +100 Not applicable Environmental HD882/G100 +100 Environmental HD882/L104 0 +250 Process Thread 7s HD882/L106 0 +250 Process Thread 1 HD882M100/600 +450 Process Thread - Miniature Head 1 HD882DM100/600 +450 Process Thread - DIN B Head 1 HD882M100/300 +100 Process Thread - Miniature Head 1 HD882DM100/300 +250 Process Thread - DIN B Head 1 CONNECTORS TP47 TP471 Connector without SICRAM module. It can be connected to 4-wire Pt100 probes (and 3-wire with some instruments) or 2-wire Pt1000 probes. Connector with SICRAM electronic module for the connection of resistance thermometers and the correction of the characteristic of the sensor. It can be connected to 3-wire or 4-wire Pt100Ω platinum temperature probes. assembling and calibration only in Delta OHM 35