MULTICHANNEL DATA RECORDERS

Similar documents
MULTICHANNEL DATA RECORDERS

Portable Data LOGGING SYSTEMS. for Professionals

CMC-99 (RS ) multichannel CONTROLLERS data recorders


horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized measured values

multichannel CONTROLLERS data recorders

ENVIRONMENTAL MONITORING & CONTROL

multichannel CONTROLLERS data recorders

ENVIRONMENTAL MONITORING & CONTROL

MULTICHANNEL CONTROLLERS, DATA RECORDERS

User manual DATA RECORDER SRD-99

User manual DATA RECORDER SRD-N16

Wall-/Pipe Mounted Universal Process Indicator

KBL Brochure. Electronic Multi-Channel Datalogger

C160 Wall-/Pipe Mounted Universal Process Indicator

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

User manual DATA RECORDER SRD-N16

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

/8 DIN Universal Process Indicator

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

USER MANUAL for. Loggy Soft v or higher. S-Toolkit v or higher SRD-99 - X X

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

MULTICHANNEL CONTROLLERS, DATA RECORDERS

LBVR1718. Description. Features channel paperless recorder

Operating Instructions VEGAMET 381

Millenium II +: general characteristics

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

GCU401. Technical specification

Precision thermometer Model CTR5000

Neon pr. ph/ ORP measurement. Applications. Description

Process displays For current and voltage

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Specification for temperature sensor calibration setup

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

02/11/2015

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

/8 DIN Motorized Valve Controller

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

Intrinsically safe batch controller Batching Master 110i

Trident and Trident X2 Digital Process and Temperature Panel Meter

JUMO Quantum PID100/PID200/PID300

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Multi-functional precision thermometer CTR3000

AIAS. Technical description

SX90 Process Controller

Paperless Recorder VGR-B100. Series

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

world class water monitoring series 42

USER MANUAL for. data logger with 0/4 20 ma inputs Loggy Soft v or higher S-Toolkit v or higher

100mm Process Indicator Recorder

The new Expert Logger 400: Industry 4.0 ready!

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Hand-held thermometer Model CTH6200

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

User manual for controller/data recorder. MultiCon CMC-99/141

Immersion Temperature Sensors

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Multifunction Transducer MT440

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

MIC-2 Multi-instrument DATA SHEET

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

DINALOG A 144 x 36 A1400 Light-Strip Indicator

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Product Description. Contents. Fusion Series. New Information December 2003

UNIVERSAL TEMPERATURE TRANSMITTER

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

IMIO100 IMIO105. DDC controllers. Summary

The CAL range of temperature controllers

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

High Voltage DC Meter

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

MIC-2 MKII, Multi-instrument DATA SHEET

Hand-held thermometer Model CTH7000

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Circuit Breaker Analyzer & Timer CAT65

MIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS

with Backlight Graphic LCD Screen

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

APP 700 Technical Specification

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Intech Micro 2400-A16-SD

SINGLE-CHANNEL PROCESS INDICATOR series 8001

02/11/2015

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

HIGH-VOLTAGE DC METER

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION MODULES CMC-99/141

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Installation / Control / Monitoring Technique

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

Transcription:

MULTICHANNEL DATA RECORDERS

Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000 000 records quick data transfer via ports: USB Host (USB flash drive), USB PC (wire), RS-485 (Modbus RTU) display measured values in C or F 12V AC/DC (11-16V DC/10-13V AC) power supply backlight: amber or white panel or wall mount version NEW The MultiLog line instruments have been designed to display and record current values, as well as to present technological parameters in a graphical form. The devices are equipped with up to 8 measuring inputs. The panel mounted version, SRD-99, operates universal temperature or analogue inputs, which enables connecting different types of sensors to one device, while the wall mounted version, SRD-N16, operates fixed inputs. A USB flash drive enables a significant simplification of the unit application: it is no longer necessary to connect a PC and data logger via the RS-485 interface, data downloading can be completed 10 times sooner than in case of using the RS-485 port. The MultiLog is equipped with 2 relay outputs. The main function of the outputs is to signal critical situations, but thanks to the expanded menu it is possible to use it in numerous control and regulation applications. Both outputs can be driven by a single measurement channel or by a group of channels (from 1 to 8 channels) with individually adjustable thresholds for every measurement channel. Signalising output states is displayed in two fields, R1 and R2, in the left upper corner of the LCD screen. 1, 4 or 8 universal inputs RTD + TC or U + I digital input 24V DC graphic LCD 2,9 display, 128 x 64 points display backlight: amber or white 2 relay outputs USB Host port USB PC communication RS-485 IP 65 front protection up to 3 000 000 records data recording period 1 s - 60 min various methods of data presentation free configuration and recording software 2

Sample configuration RS-485 TC cold junction compensation digital input 24V DC up to 8 x RTD / TC inputs 2 x EREL panel case power supply: 12V, 24V, 85-260V AC/DC USB Host USB PC 8 x RTD / TC inputs version MultiLog line The SRD-99 is the first device in MultiLog line. It s equipped with a 2,9" monochrome graphic LCD display which makes user-friendly, easy and comfortable configuration and data presentation readable and attractive. It can integrate up to eight universal inputs: temperature (RTD + TC) or analogue (U + I), one digital input for controlling a recording process, 2 electronic relay outputs with max. load 24V AC (35V DC) 200 ma, USB PC port for direct (by cable) PC connection to share data and USB Host port (front or rear) for flash data storage and configuration transfer. Main function of outputs is a signalisation of critical situations, but thanks to expanded menu it is possible to use it in numerous control and regulation applications. 96 mm 96 mm 100 mm As a result of extending the range of functional applications of the MultiLog line, the SRD-N16 wall mounted model has been designed. The new IP 65 enclosure allows using the device in harsh environments, where safe installation of a typical controller / data recorder in a panel mounted enclosure is impossible. It s equipped with a 2,9" monochrome graphic LCD display which makes user-friendly, easy and comfortable configuration and data presentation readable and attractive. It can integrate up to eight fixed (RTD, TC, U or I) inputs, one digital input for the recording process control, 2 relays with max. load 1A/250V AC and one USB Host port (front or rear) for flash data storage and configuration transfer. Main function of outputs is a signalisation of critical situations, but thanks to expanded menu it is possible to use it in numerous control and regulation applications. 161 mm 166 mm 103 mm 3

Data presentation The individual text description of each recorded channels is possible. The multi-language menu assisted with full text descriptions makes the unit configuration process fast and easy. Amber backlight Real time measurement value 18 mm high digits Up to 8 channels displayed on one screen Chart view White backlight Main setting menu Logging set-up Device information Data recording 3 000 000 data records! The MultiLog can record all 8 measurement channels at a speed of 1 sample per second. It has 8 MB built-in flash memory, what allows continuous data recording for over 9 months (8 measuring channels recorded every 1 min), enabling for data logging up to 3 000 000 records. However when a USB flash drive is plugged in the USB Host port permanently, it can significantly extend the recording time without a need of data transfering from MultiLog to a PC. The recording process is synchronized with the internal real time clock and can be stopped by a digital input of the unit at any moment. Data download The recorded data can be downloaded from the internal memory in a way which suits you best. Use a USB flashdrive or RS-485 port which allows you to perform the task wherever you are. To download data from the data logger connect it to PC via USB/RS-485 or RS-232/ RS-485 serial converter and use Loggy Soft delivered with the device. If data logger is equipped with USB Host port, then the stored data can be downloaded from the data logger without PC connection. recording mode 1 channel 4 channels 8 channels intense (every 1 sec.) 330 h 170 h 100 h medium (every 10 sec.) 130 days 70 days 45 days economy (every 1 min.) 27 months 15 months 9 months transfer data USB / RS-485 4

Software To manage such vast amount of data we have designed the free of charge Loggy Soft software to help you. The software allows to: - visualize data in the form of graphs and tables, - group measurement results, - create reports, - export data into csv files, - archiving and printing of measurements (e.g. temperature, humidity, pressure). The S-Toolkit software enables configuration reading and writing operations, updating the device firmware and obtaining basic information on MultiLog line devices through RS-485 serial interface or flash-disk devices plugged into USB port. This application enables to quickly and easily define device parameters in one of three possible configuration models. The set of parameters can be transmitted directly to the device or stored in a file for future use. Loggy Soft and S-Toolkit software can be free downloaded from Specification SRD-99 SRD-N16 Power supply Power consumption Display Measuring inputs Digital input 12V AC/DC (11 16V DC / 10 13V AC); 24V AC/DC (19V 50V DC / 16V 35V AC) or 85 260V AC/DC, all separated 7 VA typ., 12 VA max. 1, 4 or 8 universal U/I version: 0/4-20 ma, 0/1-5 V, 0/2-10V or mixed; RTD/TC version: Pt100, Pt500, Pt1000, TC (K, S, J, T, N, R, B, E), 0-60 mv, 0-75 mv, 0-100 mv, 0-150 mv or mixed; 1 x 24V DC, optocoupled graphic LCD, 128 x 64 points, with backlight (amber or white) 12V AC/DC (11 16V DC / 10 13V AC); 24V AC/DC (19V 50V DC / 16V 35V AC) or 85 260V AC/DC, all separated 3 VA typ., 5 VA max. 1, 4 or 8 fixed I version: 0/4-20 ma; U version: 0/1-5 V, 0/2-10V; RTD version: Pt100, Pt500, Pt1000; TC version: TC (K, S, J, T, N, R, B, E), -30-80 mv, -50-120 mv; 1 x 24V DC, optocoupled Measuring range I ( 0/4-20 ma ), U (0-10V): ± 9999 + decimal point, resolution > 1mV RTD: -100.0 C +600.0 C with resolution 0,1 C; -148 F +999,9 F with resolution 0,1 F TC: -200 C +1370 C (K); -50 C +1768 C (S); -210 C +1200 C (J); -200 C +400 C (T); -200 C +1300 C (N); -50 C +1768 C (R); +250 C +1820 C (B); -200 C +1000 C (E) Outputs 2 electronic relays (ER1, ER2), max. load 24V AC (35V DC) / 200 ma 2 relays (R1, R2), I max=1a, U max=30vdc/250vac (cosø=1) Sensor supply output only U/ I version: 24 V DC ± 5%, max. 200 ma ( 24V and 85 260V AC/DC), 24 V DC ± 5%, max. 50 ma ( 12V AC/DC) Data recording period Communication 1 s / 2 s / 5 s / 10 s / 15 s / 20 s / 30 s / 1 min / 2 min / 5 min / 10 min / 15 min / 20 min / 30 min / 60 min RS-485 (Modbus RTU), galvanically isolated, 1200 115200 bit/sec, 8N1/8N2, USB PC, USB Host port (front or rear) Memory capacity 8 MB internal (up to 3 000 000 data records) Operating temperature Storage temperature 0 C +50 C (standard), -20 C +50 C (option) -10 C +70 C (standard), -20 C +70 C (depending on option) RS-485 (Modbus RTU), galvanically isolated, 1200 115200 bit/sec, 8N1/8N2, USB Host port IP rate protection IP 65 (device front side, rear USB version), optional IP 65 version including gasket for panel cut-out sealing or IP 54 transparent door with key. IP 40 (front USB version) IP 65 Certificates safety requirements: PN-EN 61010-1; EMC: PN-EN 61326-1; vibration immunity: 5-150 Hz @ 1g, EN-61131-2 safety requirements: PN-EN 61010-1; EMC: PN-EN 61326-1 Case panel mount; material: NORYL - GFN2S E1 wall mount; material: ABS (case), polycarbonate (front panel) Dimensions case (WxHxD): 96 x 96 x 100 mm; panel cut-out dimensions: 90,5 x 90,5 mm; installation depth: min. 102 mm; board thickness: standard 7 mm, other depending on used board thickness brackets 166 x 161 x 103 mm (without glands); 166 x 191 x 103 mm (with glands) Glands (depend on number of channels) no glands 1 channel: 2 x M20 (multi hole inserts 2 x 5 mm), 1 x M16 4 channels: 3 x M20 (multi hole inserts 2 x 5 mm), 1 x M16 8 channels: 2 x M25 (multi hole inserts 4 x 5 mm), 1 x M20 (multi hole inserts 2 x 5 mm), 1 x M16 5

Pin assignment and Ordering backlight colour: A : amber W : white number and type of inputs: 18 : 1 x U/I 48 : 4 x U/I 88 : 8 x U/I 1T : 1 x RTD/TC 4T : 4 x RTD/TC 8T : 8 x RTD/TC USB interface: 1 : front USB Host 2 : rear USB Host SRD-99X-XX28-5X-X-0XX options: 01 : no options 11 : IP 65 gasket (rear USB Host port only) 81 : operating temp. -20 C +50 C + PCB conformal coating P1 : IP 65 gasket + operating temp. -20 C +50 C + PCB conformal coating (rear USB Host port only) power supply: 3 : 24V AC/DC 4 : 85V - 260V AC/DC 5 : 12V AC/DC 12 11 10 9 8 7 6 5 4 3 2 1 L N n.c. DIN+ RS 485 ER2 ER1 additional terminals (internally connected) 85-260V AC/DC 7VA 24 23 22 21 20 19 18 17 16 15 14 13 PE I1 I2 I3 I4 I5 I6 I7 I8 36 35 34 33 32 31 30 29 28 27 26 25 mini USB U1 U2 U3 U4 U5 U6 U7 U8 48 47 46 45 44 43 42 41 40 39 38 37 Host USB option 12 11 10 9 8 7 6 5 4 3 2 1 n.c. L N DIN+ DATA+ DATA- -RS DATA+ DATA- -RS DIN- DIN- RS 485 ER2 ER1 85-260V AC/DC 7VA 24 23 22 21 20 19 18 17 16 15 14 13 PE input 5 input 8 input 7 input 6 mini USB 36 35 34 33 32 31 30 29 28 27 26 25 input 1 wejście 3 input 2 RTD Host USB option External temperature sensor TC - + + mv input 4 U/I version RTD/TC version backlight colour: A : amber W : white number of inputs: 1 4 8 type of inputs: 1 : I ( 0/4-20 ma) 2: U (0/1-5 V, 0/2-10V) 3 : RTD (Pt100, Pt500, Pt1000) A : TC (K, S, J, T, N, R, B, E) SRD-N16X-XX21-1-X-XX1 options: 0B : USB Host (standard) 0K : USB Host + operating temp. -20 C +50 C + PCB conformal coating power supply: 3 : 24V AC/DC 4 : 85V - 260V AC/DC 5 : 12V AC/DC 21 20 19 18 17 16 15 14 13 current inputs AIN7 AIN5 AIN3 AIN1 AIN8 AIN6 AIN4 AIN2 sensor supply output I max. =200mA 22 21 20 19 18 17 16 15 14 13 PE R1 RS-485 DIN+ B- A+ 7 6 5 4 3 AIN6 AIN3 AIN1 30 29 28 27 26 25 24 23 22 PE R1 RS-485 DIN+ B- A+ 7 6 5 4 3 32 31 30 29 28 27 26 25 24 23 12 11 10 9 8 2 1 additional terminals (internally connected) RS RS R2 power supply (depending on version) AIN7 AIN4 AIN2 39 38 37 36 35 34 33 32 31 n.c. n.c. n.c. DIN- 12 11 10 9 8 DIN- RS RS R2 2 1 power supply (depending on version) AIN8 AIN5 I version RTD version 6

Accessories Security door with lock Mounting plate 100 mm 98 mm STD-99 A transparent door with IP 54 rate and lockable with security key, for 96 x 96 mm case 90,5 mm 144 mm SMP-1414/99 to mount 96 x 96 mm size unit in place of 144 x 144 mm cut-out 90,5 mm 144 mm Board thickness brackets / adaptors SPH-07 1 7 mm board thickness brackets (2 pcs) standard included with device SPH-45 1 45 mm board thickness brackets (2 pcs) SPH-05 1 5 mm board thickness brackets (2 pcs) SRH-99 brackets for mounting devices on DIN 35/7.5 or 15 rail (2 pcs) Pendrive An unusually small and light USB flashdrive has been designed with easy storage and transport in mind, fits perfectly in the case with closed IP 54 rate door. MF-8 mini pendrive / memory stick, 8 GB + strap Converters The SRS-U4 converter is designed to connect a USB host to slave devices equipped with RS-485 interface. The PC with special software can be used as a host. The SRS-U4 unit guarantees full galvanic isolation between USB and RS-485 circuits. The converter can work with any devices equipped with RS-485 interface and contains integrated circuit which supports USB 1.1 and USB 2.0 standards. The main purpose is connection of PC host computer with industrial data acquisition and visualisation systems based on RS-485 interface. The SRS-U4 can be also manufactured with DIN mounting adaptor. Complementary accessories SCL-N16 case lock P130 portable case for MultiLog 7

SIMEX Ltd. Wielopole 11 80-556 Gdańsk Poland tel. (+48) 58 762-07-77 fax (+48) 58 762-07-70 e-mail: info@simex.pl Despite the best efforts can not guarantee that the published data do not contain deficiencies or errors that can not be the basis for claims. BRSRDEN_v1.19.021