The Impact of Internet of Things (IoT) on Cable Certification

Similar documents
The Impact of Internet of Things on Cable Certification

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

Innovative system solutions flexible connection technology

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

LANmark-6 10G LANmark-6 A

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

Universal connectivity grid design guide

Standards Update. by Paul Kish NORDX/CDT

Field Term Plug Installation Guidelines

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

IoT and Intelligent Building Challenges in ICT

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

How You Can Optimize Passive Optical LAN Through Structured Cabling

Data sheet C6 A modul 1 port 180 M AP pure white

Copper Cabling Standards

Field-testing procedure. LANmark-6

[0.057] 5.8 [0.23]

Ronald Tellas, Technology and Applications Manager, Enterprise Networking

MFP8 Cat.6 A Field assembly RJ45 plug series. Simpler all over. Simpler all round. Data Voice. PoE+ 500 MHz. Cat.6 A.

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Chapter 4: Network Access. Introduction to Networks v5.1

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales

Testing and Measurement Technology. Handbook of Cable Testing. Fault Analysis Documentation and Reporting. h ps://itnetworks.softing.

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

[0.057] 5.8 [0.23]

New Standardized Cabling Options for NBASE-T Devices

Cat.8 Shielded Field Termination Plug Description

Testing Network Infrastructure

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

The High Cost of a Low-Cost Cable Certification Tester

ANSI/TIA/EIA-568-B Cabling Standard

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1

HANDBOOK OF CABLE TESTING

Series. WireXpert Key Features. Easy to use and Ruggedized design. Fast and simple for highest productivity

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.

Combining EtherCAT with Power

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

ST-POE-2P-WTP. IP67-Rated POE Extender

S1 Access Control Gateway Datasheet

Certification for 10G copper cabling

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Versatile configuration options

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Cat.8 Shielded Keystone Jack Description

HDMI and USB over IP Distribution Kit p

Standards-based Labelling: The Key to Effective Network Cabling Plan. Lin Huanyu Market Development, Regional Manager Brother International Singapore

IEEE P802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force (10SPE)

Light over PoE. Emanuele Colombo Country Manager R&M Italia October 2017

INTERNATIONAL STANDARD

Recent Changes to the Physical Layer (Chapter 8) for DeviceNet and EtherNet/IP Brad Woodman Molex

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Data sheet C6 A modul 90 jack

INTERNATIONAL STANDARD

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Data sheet C6 A modul 2 port 180 M UP pure white

CERTIFICATION PLUS SM

Distributed ConvergeIT Systems. Lee Funnell EMEA Technical Manager

2 in 1 LAN Tester and Multimeter Model:

FREQUENTLY ASKED QUESTIONS (FAQs)

E-DAT C6A. The compact connection system of course with Cat.6A

Getting to Know Your Network. Internet Speeds and Services

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Meeting updated ISO/IEC Your professional partner of structured cabling system

AMP-TWIST* 6S Series SL Jack

How new testing standards affect you Singapore, Nov 2009

ABB Three Phase String inverter

NGBASE-T Cabling Requirements

60-Watt Ultra Power over Ethernet Injector

4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT

Huddle Hub One / Huddle Hub One+ Installation Guide. Product version 1.21 Manual version 01

Cabling Infrastructure

Audio Networking. Set up a network for easier system control and monitoring.

History of Standards

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

Appendix 1 to the R&Mfreenet Warranty Program

Versatile configuration options

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

CONTENTS. Introduction Characteristics Product range. Pages

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

R&Mfreenet Advanced Cat 6A Shielded Connection Module

IpAlarm Module Set Up

Home Networks. Principles, Applications and Desirability

Telecommunications Structured Cabling Systems

SYSTIMAX imvision Controller User Guide

Switch to fast broadband today

Modular plugs, accessories and tooling

Transcription:

The Impact of Internet of Things (IoT) on Cable Certification Simon Harrison General Manager Softing Singapore Pte Ltd November 2017

Agenda Review of traditional structured cabling configurations Special cabling requirements for IoT devices Cabling architectures used with IoT devices The new link concept: End-to-End links (E2E) Testing requirements for E2E cabling New standards for testing Practical guidelines Outlook towards future applications Summary 2

Review of traditional structured cabling configurations Test Permanent Link Permanently fixed installed cabling May contain also a consolidation point Implications for Testing Tester must set reference plane so that first & last connector of link is included in measurement Test cords have special test plugs 3

Review of traditional structured cabling configurations Test Channel Permanent Link + all attached patch cords and cross connects Implications for Testing Tester must include any patch cords First and last connectors of cords are EXCLUDED from the measurement 4

Review of traditional structured cabling configurations Measurement starts before permanent link connector Measurement ends after permanent link connector Measurement starts AFTER first connector First connector is not included Measurement ends BEFORE last connector Last connector is not included 5

Special cabling requirements for IoT devices Conventional Channel or Permanent Link is often impractical Devices often need to be connected without an extra patch cord There is no structured cabling outlet at the required location Examples: Access points or cameras on walls Sensors Building automation devices Length In future, the conventional limit of 100m will not be enough 6

Special cabling requirements for IoT devices Connectors Office RJ45 often is not enough Now there is a variety of different connectors: Ruggedized RJ45 housings - dustproof, waterproof, oil proof, mechanical protection M12, D coded and X-coded M8 IX Terminal screws Future: various 1 pair connectors This is a challenge for the field tester we need to provide connectivity for all kinds of different systems! 7

Cabling architectures used with IoT devices Star Topology vs Daisy-Chain or Point-to-Multipoint 8

Cabling architectures used with IoT devices Star Topology vs Daisy-Chain or Point-to-Multipoint 9

The new link concept: End-to-End Links (E2E) New: E2E link configuration - E2E = End-to-End Up to 100m on solid wires, ~ 80m on stranded (depends on brand) Looks like a permanent link but note that an E2E has plugs at the ends, not sockets Purpose: Direct connection between equipment without using patch cables Plugs at the ends need to be included in any test because they can be terminated in the field 10

Testing requirements for E2E cabling Implications for field testers: Conventional Channel test setup CANNOT be used because Channel tests do NOT include the first and last connector Failures due to field termination other than simple wire-map errors can not be found using Channel mode! 11

Testing requirements for E2E cabling Two possible approaches to include first & last connector: A: Use dedicated adapters with an E2E reference plane B: Use dedicated adapters and test cords with sockets Advantages of B More flexible easier to reach tight locations on equipment Easier to implement new connectors 12

New standards for E2E links IEC14763-4: Measurement methods to test E2E links ISO11801-9902: Testing of E2E links ANSI/TIA 1005: Infrastructure for Industrial Premises 13

New standards for E2E links To best possible reflect the real-world requirements for IoT devices, those standards contain various E2E link configurations: from 1 to 5 segments. Note that 2 connectors close to each other may be seen as 1 or 2 connections. 1 connection if the distance between 2 connectors is less than 10cm (= a bulkhead). 2 connections if the distance is more than 10cm. A segment may also contain a socket to plug assembly. At current, standards only define E2E up to CAT6 / Class E. Another important difference to channel testing: All the different configurations have different testing limits 14

New standards for E2E links Important differences to patch cords An E2E link is NOT a patch cord A patch cord is one part, an E2E link can consist of up to 5 segments Different length, different cable types (solid, stranded, different diameters) Different testing requirements An E2E Link always has to be tested as a complete link Adding more segments requires re-testing of the complete link Sum of 3 individual segments 3 segments joint with bulkheads + + 15

Practical guidelines Make sure your tester supports E2E links check the list of available limits At present, standards only define E2E measurements up to CAT6 / Class E so maximum supported speed for Ethernet is 1000MBit/s Hybrid cords can help to access tight locations make sure the device is able to handle measurement using hybrid cords with the correct reference plane 16

Practical guidelines So how should we figure out an unknown link configuration? Use a device with time-domain features for NEXT or Return Loss, usually referred to as TD-NEXT or NEXT Locator and TD-RL or RL Locator. Run an Autotest with the Locator feature enabled. Look at the NEXT or RL Locator results. The peaks will tell you how many connections are present in that link If the E2E link consists of more than one segment, you will need to visually check at the positions shown on the Locator to see if each peak is to be treated as one connection or two. 10cm is less than the typical resolution of time domain features on certifiers. Example: 2 Segment E2E link 17

Outlook other examples of potential E2E applications Data Centre Direct connection between devices For example servers in the same row (But note: E2E is not yet standardized for CAT6A / Class E A ) Professional Entertainment Cabling on the fly for stage equipment, sound and lighting Home Networking/Entertainment Wi-Fi is of course very important, but some devices still need copper connections for example: Access points IoT gateways for proprietary wireless systems IPTV boxes 18

Outlook what comes next? E2E and 10GBit/s Next revision of ISO standards for E2E will contain limits up to CAT6A / Class E A 1 Pair various new configurations new field of applications 15m and 40m Mainly interesting for automotive applications 15m for cars, 40m for buses and trucks, minimum 1GBit/s Car sensors, cameras, actuators, controls, entertainment 1000m, 10MBit/s Very interesting for industrial automation, IoT devices Drive any sensors, building automation devices, cameras PoDL: Power over Data Lines 1 Pair cabling to provide power to IoT devices 19

Outlook what comes next? Newest ideas for 1 pair Adopt 1 pair cabling for office applications 100m, 1000MBit/s New consolidation point -like structure 4 pair to a consolidation point and Switch then 4 x 1 pair to 4 devices Reasons Many office devices do not need more than 1000MBit/s Laptops are becoming so thin that they cannot accommodate an RJ45 Provide a copper Ethernet link to tablets, monitors, terminals using the smallest possible cable and connector 20

Summary IoT opens up a wide range of new cabling and testing applications Increasing speeds and the performance requirements of these new applications make testing absolutely necessary Testing of IoT cabling requires special testing approaches and MUCH more flexibility in terms of what needs to be tested Various different connector types Various different configurations Not just Permanent Link and Channel First round of IEEE, ISO/IEC and TIA standards are released, but this is just the beginning: Further standards will follow to cover new applications 21

Questions? Thank you for your attention