Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Similar documents
Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Features: DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply

Features: Example of use

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

PSBOC PSBOC 27,6V/5,5A/OC

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

PSBEN 10A12E. PSBEN 13,8V/10A/65Ah/EN Buffer, switch mode power supply unit Grade 3.

PSBEN 3012C. PSBEN 13,8V/3A/17Ah/EN Buffer, switched mode power supply unit.

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

PSBEN 2012B v.1.1/vii PSBEN 13,8V/2A/7Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

Buffered Power Supply PS-30DR v1.0

v.1.1/iv EN54 27,6V/7A/2x40Ah power supply for fire alarm systems

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Switches & Power over Ethernet

Industrial PoE Media Converter

Buffer power supply units. compliant with EN are intended to alarm system devices

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Hardened PoE Ethernet Switch

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

PSBEN 5012D/LCD. PSBEN 13,8V/5A/40Ah/EN/LCD Buffer, switched mode power supply unit.

PSBEN 2012B/LCD. PSBEN 13,8V/2A/7Ah/EN/LCD Buffer, switched mode power supply unit.

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

imc2g Features Introduction Industrial Gigabit Ethernet to Fiber Media Converter Tel: Fax:

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Language of the manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

THOR Battery Backed DC Power Supply Reference Manual

Switched Mode Power Supply Operating manual PAP800

Model : ON-PS3016G. 16 Port 10/100/1000Mbps Gigabit + 2 Gigabit SFP Uplink Unmanaged PoE Switch

Industrial Ethernet Switch

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

High-Power Unmanaged PoE Switch with LCD Status Display. Power over Ethernet 802.3at. Innovative LCD Status Display

EN54-2A17. EN54 27,6V/2A/2x17Ah power supply for fire alarm systems

2 in 1 LAN Tester and Multimeter Model:

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Quick Start Guide. Physical Description.

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

ON-AI port 10/100Mbps + 1 GE & 1 SFP uplink (Combo port) AI POE Switch

imc2f Features Industrial IEC Ethernet to Fiber Media Converter Tel: Fax:

Quick Start Guide. Physical Description. The Port Status LEDs

PTC-101 Quick Installation Guide

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

imc2 Features Introduction Industrial 2 Port Ethernet to Fiber Converter Tel: Fax:

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Fibre Optic and Wireless Solutions

Interface RS485-WiFi

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

RТTH DUAL ROOM SWITCH

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

Save installation time and money with PoE.

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Industrial Unmanaged Ethernet Switch

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

IMC-P111FX / IMC-P111P Series

Rugged MediaConverter

EDS-G205A-4PoE Hardware Installation Guide

IMC-P111FX Series IMC-P111P Series

DIN-Rail Mounting 6-port 100M/Gigabit Layer 2 Unmanaged Industrial PoE Ethernet Switch

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

PTC-101-M12 Hardware Installation Guide

5-Port 10/100TX with 4 PoE Injector Industrial Switch

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

User Manual. cmt-svr Startup Guide

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

New products No. 1 / 2018

User Manual. cmt-svr Startup Guide

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Save installation time and money with PoE and get the most out each PoE connection with PoE passthrough!

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Industrial Slim Type Fast Ethernet Rail Switch

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Safety Standards. Model Number:

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

POWER SUPPLY SYSTEM DSO 24V FOR PAVIRO SYSTEM BY BOSCH

Transcription:

DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras Edition: 3 from 07.03.2018 Supercedes the edition: 2 from 15.11.2017 EN** Features: Uninterruptible power supply of 8 IP cameras (52VDC) Switch 10 ports 8 PoE 10/100Mb/s ports, (1 8 ports) (data and power supply) 2 ports 10/100/1000Mb/s (G1/TP, G2/TP ports) (UpLink) 2 ports 10/100/1000Mb/s SFP (G1/SFP, G2/SFP ports) Battery charge current 0,5A (batteries 2x7Ah / 2x17Ah) 30W for each PoE port, supports devices complaint with the IEEE802.3af/at (PoE+) standard Approximate backup time: 5h 30min LED indication Metal housing - color black RAL9005 - with optional possibility of DIN rail mounting (TH35) Supports auto-learning and auto-aging of MAC addresses (1K size) warranty 2 year from the production date Example of use. CONTENTS 1. Technical description. 1.1 General description 1.2 Block diagram 1.3 Description of components and connectors 1.4 Technical parameters 2. Installation. 2.1 Requirements 2.2 Installation procedure 3. Indication of the device operation 3.1 Optical indication of the switch operation 4. Operation and use. 4.1 Overload or short circuit of the PSU output (SCP on) 4.2 Disconnection of discharged battery 4.3 Maintenance 1

1. Technical description 1.1. General description. The DSFB108 switch is designed for uninterruptible power supply of 8 IP cameras (52VDC voltage) and is housed in a metal enclosure with optional possibility of DIN rail mounting (TH35). The main elements of this system include: - 10 ports PoE switch - buffer power supply unit 27,6V which can accommodate 2 x 17Ah/12V batteries - a converter (DC/DC52230) increasing the voltage to 52VDC (supply of the PoE switch) In case of power decay, a battery back-up is activated immediately. The approximate backup time is given assuming that all output ports are used (using typical devices and 17Ah batteries). The electricity consumption for own needs and the energy efficiency of the power intake track were taken into account. The exact description of how to perform the calculations can be found at: "Approximate backup time - assumptions for calculations". Automatic detection of any devices powered in the PoE/PoE+ standard is enabled at the 1 8 ports of the switch. The G1/TP, G2/TP ports is used for connection of another network device via RJ45 connector. The switch is fitted with SFP slots. (marked as G1/SFP and G2/SFP); the use of fiber optic module (GBIC) allows fiber optic transmission. The LEDs at the front panel indicate the operation status (description in the table. 8). The switch is housed in a metal enclosure (color RAL 9005) with optional possibility of DIN rail mounting (TH-35). The switch can be mounted in horizontal or vertical position. The operating position can be adjusted by changing the mounting position (see Fig. 2b). The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access point or router. 1.2 Block diagram. Fig. 1. Block diagram. 2

1.3 Description of components and connectors. Fig. 2. The view switch'a - front. Fig. 2b. The view switch'a - rear. Table 1. (See Fig. 2) Component No. (Fig. 2) Description [1] Switch PoE [2] Power supply connector of the PSU L, N PE protective connector (electric shock) [3] BAT +, BAT - battery output [4] Holder for DIN rail (80x50) Fig. 3. The view of the switch. 3

Table 2. (See Fig.3) Component No (Fig. 3) Description [1] 8 x PoE port (1 8) [2] 2 x UPLINK ports (G1/TP, G2/TP) [3] 2 x UPLINK ports (G1/SFP, G2/SFP) 1.4 Technical parameters - parameters of the switch (tab.3) - electrical parameters (tab.4) - mechanical parameters (tab.5) - operation safety (tab.6) - operating parameters (tab.7) Table 3. Parameters of the switch 8 x PoE (10/100Mb/s) (RJ-45) Ports 2 x UPLINK (10/100/1000Mb/s) (RJ-45) 2 x UPLINK (10/100/1000Mb/s) (SFP) with connection speed auto-negotiation and MDI/MDIX Auto Cross) PoE power supply IEEE802.3af/at (1 8 ports), 52V DC / 30W at each port * Protocols, Standards IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP Forwarding rate 10BASE-T: 14880pps/port 100BASE-TX: 148800pps/port Bandwidth 1,6Gbps Transmission method Store-and-Forward Switch power supply; Optical indication of Link/Act; operation PoE Status * The given value of 30W per port is the maximum value. The total power consumption should not exceed 96W when all PoE ports are being used. Table 4. Electrical parameters Mains supply Current up to Supply power Output current at the PoE ports (RJ45) Output voltage at the PoE ports (RJ45) Short-circuit protection SCP and overload protection OLP PSU current consumption Battery charge current (batteries 2x7Ah / 2x17Ah, connect batteries in series) Approximate backup time Battery circuit protection SCP and reverse polarity connection Deep discharge battery protection UVP 176 264V AC 1A@230VAC max. 110W 8 x 0,6A ΣI=2A (max.) 48VDC 105% 150% PSU power, manual restart (the fault requires disconnection of the DC output circuit) 200mA/27,6V 0,5A max. /2x17Ah (+/-5%) 5h 30min glass fuse U<19V (± 5%) disconnect of connection battery 4

Table 5. Mechanical parameters Dimensions W=275, H=110, D=210, D 1=9, D 2=24 [+/- 2mm] Mounting For DIN rail TH35 Gross/Net weight 3,8 / 3,9 kg Enclosure Steel plate, DC01 1,0mm color black RAL 9005 Power supply of the cameras: RJ45 socket Connectors battery output BAT: 6,3F-2,5 Power input: Φ 0,51-2,59 (AWG 24-10) Notes The enclosure does not touch the assembly surface so that cables can be led. Table 6. Operation safety Protection class PN-EN 609501:2007 I (first) Protection grade PN-EN 60529: 2002 (U) IP20 Electrical strength of insulation: - between input and output circuits of the PSU (I/P-O/P) 3000 V/AC min. - between input circuit and PE protection circuit (I/P-FG) 1500 V/AC min. - between output circuit and PE protection circuit (O/P-FG) 500 V/AC min. Insulation resistance: - between input circuit and output or protection circuit 100 MΩ, 500V/DC Declarations, warranty CE, 2 year from the production date Table 7. Operating parameters Operating temperature Storage temperature Relative humidity Vibrations during operation Impulse waves during operation Direct insulation Vibrations and impulse waves during transport -10ºC...+40ºC -20ºC...+60ºC 20%...90%, without condensation unacceptable unacceptable unacceptable According to PN-83/T-42106 2. Installation 2.1. Installation procedure The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC and low-voltage installations. The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity (RH=90% max. without condensation) and the temperature from -10 C to +40 C. The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the enclosure. Before installation, prepare a Switch'a load balance. The given value of 30W per port is the maximum value referring to a single output. The total power consumption should not exceed 96W when all PoE ports are being used. The increased demand for power is particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the power consumption increases rapidly, which may adversely affect the operation of the switch. As the device is designed for a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate fuse in the fuse-box). The electrical system shall follow valid standards and regulations. 2.2. Installation procedure 1. Before installation, cut off the voltage in the 230V power-supply circuit. 2. Mount the switch DSFB108 in a selected location and connect the wires. 3. Connect the power cables (~230VAC) to L-N clips of the PSU. The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire coat of the power cable shall stick to one side of the terminal - marked with symbol on the PSU enclosure. Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a device failure or an electric shock. 5

4. Connect the ground wire to the terminal marked with the symbol (power supply module connector). Connect the ground wire to the clip marked by the earth symbol PE. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. Lead the cables to the appropriate clips through the insulating bushing of the connection board. 5. Connect the power (~230V). 6. Connect the batteries in series/parallel to the + BAT- terminals: - battery output (+): BAT+ cable / red, - battery output (-): BAT cable / GND / black. 7. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network (the UPLINK connector). 8. Check the optical indication of the switch operation. 3. Indication of the device operation. 3.1 Optical indication of the switch operation (see Table 8). Table 8. Indication of the switch operation OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY GREEN LED LIGHT (Power) Indication of the switch's power supply OFF no power supply of the switch ON power supply on, normal operation OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY (1 8) DIODA LED ZIELONA (PoE) Indication of the PoE power supply at the RJ45 ports YELLOW LED LIGHT (LINK) The connection status of LAN devices, 10MB/s or 100Mb/s and data transmission OFF- no power supply at the RJ45 port (the device is not connected or not compliant with the IEEE802.3af/at standard) ON supply Blinking short-circuit or output overload OFF- no connection ON - the device is connected; 10Mb/s or 100Mb/s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT YELLOW LED LIGHT (LINK) OFF- no connection ON - the device is connected Blinking data transmission CAUTION! The operating status of the G1/TP, G1/SFP, G2/TP and G2/SFP slots is shown on the LEDs located near the RJ45 connector (see below). CAUTION! G1/TP and G1/SFP or G2/TP and G2/SFP sockets can not operate simultaneously. These are COMBO type sockets. GREEN LED LIGHT (SPEED) OFF connection 10Mb/s or 100Mb/s ON - connection 1000Mb/s CAUTION! The operating status of the G1/TP, G1/SFP, G2/TP and G2/SFP slots is shown on the LEDs located near the RJ45 connector (see below). CAUTION! G1/TP and G1/SFP or G2/TP and G2/SFP sockets can not operate simultaneously. These are COMBO type sockets. The example of mounting the DSFB108 switch on a DIN rail (TH35) (DIN rail not included) 6

4. Operation and use. 4.1 Overload or short circuit of the PSU output (SCP on). In case of overload, the output voltage is automatically shut off. The restoration of the voltage takes place immediately after the failure (overload) is over. 4.2 Disconnection of discharged battery. The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation, reducing voltage below 19V at the battery terminals will cause battery disconnection. 4.3 Maintenance. The PSU does not require performing any specific maintenance measures. 7

WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl 8